• 제목/요약/키워드: Domestic Wastewater

검색결과 322건 처리시간 0.028초

강우시 합류식 하수관거의 월류수 차집용량 산정을 위한 유출특성 분석 (Analysis of Storm Water Run-off Characteristics to Evaluate the Intercepted Volume of CSOs during Wet Weather)

  • 최성현;최승철;김병욱;임재명
    • 상하수도학회지
    • /
    • 제18권3호
    • /
    • pp.320-330
    • /
    • 2004
  • Most of domestic city is served combined sewer system among various sewer system like as separate sanitary, combined sewer system and storm sewers. During the wet weather, sewer and rainfall have been overflowed because it is over capacity of the combined sewer system; that is called combined sewer overflows(CSOs) This research was carried out to investigate runoff characteristics of combined sewer and to evaluate the effective CSOs volume in Hong-Chun gun. During wet weather, SS load of first rainfall at H-1, H-2, and H-3 were 600kg/event, 370kg/event, and 289kg/event, respectively. 55 load of second rainfall were 216kg/event, 113kg/event, and 37.2kg/event. When the first rainfall, event mean concentrations(EMCs) at each site were 702mg/L, 816mgjL and 861.5mg/L. The second rainfall's event mean concentrations(EMCs) were 99.9gm/L, 161.9mg/L, 103.6mg/L. Rrst flush coefficient b at each site were 0.237,0.166, and 0.151. When the first rainfall, the flow containing 80% of pollutant mass of CSOs at each site were 0.55, 0.23, 0.48 in first rainfall, respectively. The case of second rainfall were 0.79, 0.83, 0.81. Most of all, characteristics of rainfall like as analysis of first-flush, CSOs volume, pollutant loadings is investigated to decide intercepted volume for control of CSOs.

네트워크 통합관리시스템과 보안스위치를 이용한 반송정수장 무선랜 구축사례 (The case study on wireless lan design technique for Bansong purification plant using network integrated management system and security switch)

  • 박은철;최현주
    • 상하수도학회지
    • /
    • 제32권4호
    • /
    • pp.309-315
    • /
    • 2018
  • Currently, the commercialization of the $5^{th}$ Generation (5G) service is becoming more prevalent in domestic communication network technology. This has reduced communication delay time and enabled large-capacity data transmission and video streaming services in real-time. In order to keep pace with these developments, K-water has introduced a smart process control system in water purification plants to monitor the status of the water purification process. However, since wireless networks are based on the public Long Term Evolution (LTE) network, communication delay time remains high, and high-resolution video services are limited. This is because communication networks still have a closed structure due to expense and security issues. Therefore, with 5G in its current form, it is very difficult to accommodate future services without improving the infrastructure of its communication networks. In recognition of these problems, this study implemented the authentication and management function of wireless networks on a wired network management system in the K-water Bansong water purification plant. The results confirmed that wired Local Area Network (LAN) services give a higher security performance than an expensive commercial wireless LAN system. This was achieved by using an Internet Protocol (IP) address management system of wired networks and the packet filtering function of the Layer2 (L2) switch. This study also confirmed that it is possible to create a wireless LAN service that is 3.7 times faster than the existing LTE communication network.

관 세척에 따른 색도성 물질의 제거 효과 (Removal of discoloration materials by water mains cleaning on water distribution pipes)

  • 이호민;최태호;윤현우;김동홍;배철호
    • 상하수도학회지
    • /
    • 제34권4호
    • /
    • pp.267-276
    • /
    • 2020
  • In this study, air scouring cleaning was selected and applied among 5 small blocks (S1~S5) in domestic S cities to analyze the cleaning effect of particles causing discoloration. In order to identify the cleaning effect, 10 locations were selected as water quality investigation point, such as the stagnant or water mains ends. Removal of solids, variation of particle components, weight and concentration were analyzed. And the level of the cleanness of the surface inside water mains using endoscope was investigated. As a result of analysis, the solids discharged after cleaning were mainly sand and gravel, pieces related to pipe materials, and corrosion products. As a result of analyzing the concentrated particles of the filter before and after cleaning, it was found that the change in discoloration on the filter was large. In addition, as a result of comparing the weight and the concentration of the particles, it was found that the particles causing discoloration were significantly removed after cleaning. From the results of the endoscopy, it was confirmed that most of the precipitated and accumulated dark yellow discoloration matters inside water mains were removed through cleaning. Therefore, it seems that the particles causing discoloration in water decreased after cleaning. Therefore, it is expected that, if properly cleaning was applied, matters that cause discoloration can be removed from the water mains, and customer's complaints can also be reduced through water quality improvement.

Blue dam을 활용한 기존 댐 시설물 상수도 원수 추가 확보 방안 (The method of securing water supply resources of existing dam by using Blue dam)

  • 추태호;윤현철;윤관선;권용빈;심수용;채수권
    • 상하수도학회지
    • /
    • 제29권2호
    • /
    • pp.243-249
    • /
    • 2015
  • To improve stability of the water resources that were seriously affected by climate change and various environmental effects and to supply the clean water always, continuous efforts are essential. Provision of measures with respect of hardware is basically essential to improve the water resources stability due to the topographic characteristic in Korea. However, building a new dam becomes gradually very difficult because of a hardship in selecting right places, opposition forces such as environment and local residents, negative publicity for large civil engineering projects, and so on. The present study, therefore, proposes the Blue dam as an alternative for securing the water resources of a new concept considering domestic conditions. To evaluate the effect of the Blue dam, the Hec-ResSim model is used and the probabilistic discharge flow rate is applied. As a result, when Dam Yeongcheon is applied as a study area, securing water resources of 14 million tons are predicted be secured and the flood control of 15.4 million tons is expected, in comparison with operation of the existing dam only. Consequently, Blue dams are supposed to carry out the function of securing water resources, controling flood, maintaining eco-environmental instream flow, generating hydroelectric power, and providing spaces for recreational activities.

SWRO-PRO 복합해수담수화 기술의 현재와 미래 (The present and future of SWRO-PRO hybrid desalination technology development)

  • 정경미;여인호;이원일;오영기;박태신;박용균
    • 상하수도학회지
    • /
    • 제30권4호
    • /
    • pp.401-408
    • /
    • 2016
  • Desalination is getting more attention as an alternative to solve a global water shortage problem in the future. Especially, a desalination technology is being expected as a new growth engine of Korea's overseas plant business besides one of the solutions of domestic water shortage problem. In the past, a thermal evaporation technology was a predominant method in desalination market, but more than 75% of the current market is hold by a membrane-based reverse osmosis technology because of its lower energy consumption rate for desalination. In the future, it is expected to have more energy efficient desalination process. Accordingly, various processes are being developed to further enhance the desalination energy efficiency. One of the promising technologies is a desalination process combined with Pressure Retarded Osmosis (PRO) process. The PRO technology is able to generate energy by using osmotic pressure of seawater or desalination brine. And the other benefits are that it has no emission of $CO_2$ and the limited impact of external environmental factors. However, it is not commercialized yet because a high-performance PRO membrane and module, and a PRO system optimization technology is not sufficiently developed. In this paper, the recent research direction and progress of the SWRO-PRO hybrid desalination was discussed regarding a PRO membrane and module, an energy recovery system, pre-treatment and system optimization technologies, and so on.

상수도관로 누수신호의 특성 분석을 위한 누수 실험시설 개발 (Development of leakage test facility for leak signal characteristic analysis in water pipeline)

  • 박상혁;곽필재;이현동;최창호
    • 상하수도학회지
    • /
    • 제31권5호
    • /
    • pp.459-469
    • /
    • 2017
  • A real scale leakage test facility was developed to study the leak signal characteristics of water supply pipelines, and then leak tests were carried out. The facility was designed to overcome the limited experimental circumstances of domestic water supply pipeline experimental facilities. The length of the pipeline, which was installed as a straight line, is 280m. Six pipes were installed on a 70m interval with different pipe material and diameters that are DCIP(D200, D150, D100, D80), PE(D75) and PVC(D75).The intensity of the leakage is adjusted by changing the size of the leak hole and the opening rate of ball valve. Various pressure conditions were simulated using a pressure reducing valve.To minimize external noise sources which, deteriorate the quality of measured leak signal, the facility was built at a quiet area, where traffic and water consumption by customers is relatively rare. In addition, the usage of electric equipment was minimized to block out noise and the facility was operated using manual mode. From the experimental results of measured leakage signal at the facility, it was found that the signal intensity weakened and the signal of high frequency band attenuated as the distance from the water leakage point increased.

수계의 비점오염원 관리 - 대청호를 중심으로 (Management of Nonpoint Sources in Watershed - with reference to Daechong Reservoir in Korea)

  • 이종호
    • 환경영향평가
    • /
    • 제9권3호
    • /
    • pp.163-176
    • /
    • 2000
  • The purpose of this study is to analyze the pollutant loads and its distribution, and to suggest the management of nonpoint sources in Daechong Reservoir. The loads from point and nonpoint sources such as population, industry, livestock and land use were calculated per stream or river with topography(1:25,000) of the watershed of Daechong Reservoir. The generating pollutant loads were obtained through multiplication of pollutant sources by generating pollutant quantity per unit pollutant source. The effluent point sources loads is defined as loads from wastewater treatment facilities such as domestic, industrial and livestock wastewater treatment facilities, which were calculated through multiplication of effluent flowrates by water quality constituents concentration. Untreated point sources loads were estimated to be 35 % of total point sources loads. The effluent nonpoint sources pollutant loads were obtained through the multiplication of generating nonpoint sources loads by effluent ratios based on previous studies. The effluent nonpoint sources loads have the ratio of 26.2% of total BOD effluent loadings, 20.1% of total T-N effluent loadings, and 10.5% of total T-P effluent loadings. For the reduction of nonpoint sources loads in Daechong Reservoir, silviculture, artificial wet land, and grassed waterways could be applied. And untreated livestock waste scattered can result in nonpoint loadings, so required the livestock wastes treatment facilities and purifying facilities together with the management of shed, pasture, livestock waste storage site and composting site. Finally, remote sensing and GIS should be applied to the identification of distribution of water quality, watershed, the location and scale of nonpoint sources, effluent process during rainfall, for more detailed analysis of nonpoint sources.

  • PDF

야간사용량 측정을 통한 배급수구역 배경야간최소유량 산정 (Estimation of background minimum night flows by metering water use in water distribution areas)

  • 이두진;김주환;김도환;김경필
    • 상하수도학회지
    • /
    • 제24권5호
    • /
    • pp.495-508
    • /
    • 2010
  • The aim of this study is to develop a quantified water loss Index to evaluate and manage leakage scientifically for the reduction of non-revenue water in water distribution systems. For the purpose, unavoidable background leakage suggested from UK water industry and IWA, and allowable water leakage in accord with the concept of allowable water loss are proposed by analyzing the inflow into two study water districts and the short-term water use of each customer in the districts. The study distribution areas are selected among the metered districts with good maintenance of leakage after improvement activities in Nonsan, medium sized city in Korea. Estimation models of allowable leakage are developed by metering and analyzing the minimum night flow at residential and commercial areas in the city. In the results of the investigation, it is estimated that background night flow in residential area was larger than that of commercial area where the types of business shows small water use characteristics. Meanwhile, night flow and background water loss on internal plumbing systems show great differences for each district which is influenced much by the water use characteristics and facilities scale. Based on metering water use data in various districts, leakage management criteria can be established under the consideration of domestic conditions in Korea by analyzing separated real water use and background leakage and it is possible to apply into presentation of optimal leakage level and reasonable time for working activities for leakage reduction.

미생물 연료 전지 적용을 위한 양성자 교환막에 대한 검토 (Review on Proton Exchange Membranes for Microbial Fuel Cell Application)

  • 김지민;라즈쿠마 파텔
    • 멤브레인
    • /
    • 제30권4호
    • /
    • pp.213-227
    • /
    • 2020
  • 재생 불가능한 에너지 자원이 수년에 걸쳐 고갈됨에 따라, 재생 에너지 생산을 위한 보다 효과적인 방법에 대한 연구가 증가되었다. 연로전지 개발의 한 분야인 미생물 연료전지(MFC)는 이중 성능의 잠재력 덕분에 발전하였다. MFC는 박테리아와 같은 전극 감소 생물에서 전력을 모아서 전기 에너지를 생산한다. MFC는 폐수를 연료로 사용하여 에너지를 생산하고 폐수를 정화한다. 양성자 교환막(PEM)은 양극과 음극 챔버의 분리막으로, 양성자만 효과적으로 통과할 수 있게 하는 중요한 역할을 한다. Nafion은 MFC에 상업적으로 사용되는 PEM이지만 비용, 생산 시간, 양성자 전도성 차원에서 보완할 점들이 많다. 본 리뷰 논문에는 Nafion을 대체할 수 있는 새로 개발된 PEM 몇 가지를 논의하였다. 또한, PEM, 혼합 PEM 및 복합 PEM에 기반한 MFC를 요약하고자 한다.

Effects of Fermented Leachate of Food Waste (FLFW) and Temperature on Nutrient Removal in Sequencing Batch Reactor

  • Roh, Sung-Hee;Chun, Young-Nam;Lee, Sook-Young;Cheong, Hyeon-Sook;Lee, Jae-Wook;Kim, Sun-Il
    • Environmental Engineering Research
    • /
    • 제13권3호
    • /
    • pp.155-161
    • /
    • 2008
  • This study examined effects of the fermented leachate of food waste (FLFW) on nitrogen and phosphorous removal for domestic wastewater containing a low carbon-to-nitrogen (C/N) ratio in sequencing batch reactor (SBR). When the FLFW was not supplied in the process, release of phosphorus and excessive intake was not observed at both anaerobic and aerobic stages. On the other hand, when the FLFW was gradually added, active release of phosphorus and intake of phosphorus was noticed at an anaerobic stage and aerobic stage, respectively, resulting in improved phosphorus removal efficiency. The removal efficiency of nitrogen and phosphorus was increased from 75% and 37% (R-1, control test) to 97% and 80% (R-4, the highest substrate ratio test), respectively. In addition, although activity of the nitrogen oxidizing microorganisms was reduced when the reaction temperature was decreased to $10^{\circ}C$, the phosphorus removal efficiency was shown to increase with the addition of FLFW, indicating an independence from temperature. Overall, this study suggests that an efficient nutrients removal process can be successfully employed into a SBR when the FLFW is added to a wastewater which has a low C/N ratio.