• Title/Summary/Keyword: Domestic Noise

Search Result 307, Processing Time 0.03 seconds

A study on improving the performance of special ambulances (특수구급차 성능 개선을 위한 조사 연구)

  • Yoon, Byoung-Gil;Yang, Hyun-Mo;Kim, Gyoung-Yong
    • The Korean Journal of Emergency Medical Services
    • /
    • v.26 no.1
    • /
    • pp.87-99
    • /
    • 2022
  • Purpose: This study aimed to provide basic data for the improvement of the standards related to the performance improvement of the firefighting equipment standards for special ambulances. Methods: Among the domestic firefighting equipment standards, the special ambulance standard was compared with the NFPA 1917 standard for the United States automobile ambulance 2019 and European Union European standard EN 1789 medical vehicle and its equipment, a road ambulance. Results: Anti-skid performance based on indoor noise standards, performance standards for interior lights, seat belt warning device, child car seat fixing device, safety handle, auxiliary footrest, and flooring materials should be supplemented. Conclusion: It is necessary to strengthen the production and performance standards for improvement to a level corresponding to the national standards, such as the United States and European Union.

A study on the Application of Inorganic Reinforced Non-Flammable Molding to Building Exterior (무기계보강 CLC 불연몰딩의 건축물 외벽적용 연구)

  • Kwon, Hae-Won;Gong, Min-Ho;Lee, Chang-Woo;Choi, Byung-Cheol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.61-62
    • /
    • 2021
  • Exterior wall molding, which is widely applied as a design element of the exterior wall of domestic apartment, should be applied as a nonflammable or semi-nonflammable material grade according to the rules on standards for evacuation/fire protection structures of buildings. For this reason, stone and AL sheet are mainly used, but stone is expensive and design autonomy is low. Inorganic reinforced CLC nonflammable molding was applied to the exterior wall of the building through tests of nonflammable performance, noise reduction, and installation stability.

  • PDF

A Case Study on the Data Processing to Enhance the Resolution of Chirp SBP Data (Chirp SBP 자료 해상도 향상을 위한 전산처리연구)

  • Kim, Young-Jun;Kim, Won-Sik;Shin, Sung-Ryul;Kim, Jin-Ho
    • Geophysics and Geophysical Exploration
    • /
    • v.14 no.4
    • /
    • pp.289-297
    • /
    • 2011
  • Chirp sub-bottom profilers (SBP) data are comparatively higher-resolution data than other seismic data and it's raw signal can be used as a final section after conducting basic filtering. However, Chirp SBP signal has possibility to include various noise in high-frequency band and to provide the distorted image for the complex geological structure in time domain. This study aims at the goal to establish the workflow of Chirp SBP data processing for enhanced image and to analyze the proper parameters for the domestic continental shelf. After pre-processing, we include the dynamic S/N filtering to eliminate the high-frequency component noise, the dip scan stack to enhance the continuity of reflection events and finally the post-stack depth migration to correct the distorted structure on the time domain sections. We demonstrated our workflow on the data acquired by domestically widely used equipments and then we could obtain the improved seismic sections of depth domain. This workflow seems to provide the proper seismic section to interpretation when applied to data processing of Chirp SBP that are largely used for domestic acquisition.

The Reliability Design Method According to the Experimental Study of Components and Materials of Railway Rail Fastening System (철도용 레일체결장치 부품.소재의 실험적 연구를 통한 신뢰성 설계 방안)

  • Kim, Hyo-San;Park, Joon-Hyung;Kim, Myung-Ryule;Park, Kwang-Hwa;Lee, Dal-Jae
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.2090-2100
    • /
    • 2011
  • Railway rail fastening system is the critical device which gives big influences to not only the vehicle driving stability and the orbit's structural stability against the impulsive load, but also the noise vibration and the ride comfort. As a part of the low-carbon green growth, the importance of the railroad industry is getting highlights on its excellent energy-efficiency and eco-friendliness. However, so far the Korea's domestic rail fastening system technology is not so good and the technical reliance to abroad is very heavy. In this study, we conducted comparative analysis on the rail fastening system with new and used one of the same type. And those systems are imported by Seoul Metro and are being used by it. With this basis, we developed the components and the materials and then, established the durability assessment methods appropriate to the Korean domestic circumstances. And through the reliability qualification test on the 7 parts of the rail fastening system, we've improved the reliability and guaranteed the 15 years of service lifetime. ($B_{10}Life15$) Establishment and standardization of Reliability Standard on the parts of the rail fastening system such as anti-vibration pads, guide-plate, screw spike made it possible to perform the internationally fair assessment. And it is thought that we can satisfy the manufactures' and consumers' needs of cost-cutting and qualification security by shortening of assessment period on rail fastening system.

  • PDF

Evaluation of the Possession of Measurement and Analytical Instruments among Domestic Work Environment Monitoring Service Providers (I) (국내 작업환경측정기관의 측정 및 분석장비 보유실태에 대한 고찰 (I))

  • Jang, Jae-Kil
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.23 no.3
    • /
    • pp.250-260
    • /
    • 2013
  • Objectives: The aim of this study is to analyze the current status of the possession of measurement and analytical instruments among work environment monitoring organizations that have been designated by the Ministry of Employment and Labor (MoEL) in Korea. Methods: Data for measurement and analytical instruments were gathered by inspectors who had been assigned by the Korea Occupational Safety and Health Agency (KOSHA) and MoEL during the evaluation program for designated work environment monitoring service providers in 2012. Data for 11 monitoring instruments and nine analytical instruments were collected from 108 organizations. Basic data such as the type of service provides and the size of employment were also recorded by the inspector. Results: The total number of personal air samplers including high and low flow rates operated in Korea was 5,418, with average of 50.2. Average operation number of noise dosimeters was 35.0, while 3,780 dosimeters were used in 108 work environment monitoring organizations. There were 10,488 monitoring instruments in total. All service providers possessed at least one AAS and GC in their analytical laboratory. Total number of HPLC/MS was five, followed by ICP/MS of seven, with an average of 0.07. Conclusions: Based on the data, domestic work environment monitoring service providers possessed relatively reasonable measurement and analytical instruments. Nearly all instruments had been imported from advanced countries such as USA, UK and Japan. Periodic gathering of data on these instruments may help maintain good workplace monitoring results and the health of workers at the sites.

UHF Narrow Band Type Partial Discharge Diagnosis Method for the Internal Insulation Performance Verification of the Gas Insulated Switchgear (가스절연 개폐장치의 내부절연 성능검증을 위한 UHF 협대역 부분방전 진단법)

  • Song Won-Pyo;Kim Jung-Bae;Kim Min-So;Jung Jae-Ryong;Park Seung-Jae;Ko Heui-Suk
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.9
    • /
    • pp.414-420
    • /
    • 2005
  • A method for partial discharge diagnosis based on UHF narrow band type for GIS has been developed and calibrated. In generally, PD cannot be directly measured under on-line condition, but we can indirectly measure the electromagnetic wave made by PD using the high-frequency antenna. Compared with VHF band, electromagnetic waves of UHF band have a low influence for external noise in high-voltage substation. Therefore, we can detect the real abnormality with several pC in GIS using UHF narrow-band type method. For the case of no internal VHF sensor for GIS of the domestic substation, it has applied to use the external UHF sensor attached in spacer in GIS of existing substation. In this paper, we firstly described the technique of partial discharge measurement using frequency analysis and phase analysis in UHF band. Secondly, we presented the results of sensitivity test, the relationship of dBm-pC and diagnosis result of the cause of PD source by phase analysis. And then, we report the diagnosis result of partial discharge on the real GIS in domestic substation. These results make above method applicable for measurement of quantity and cause of PD for real operation GIS in high-voltage substation.

Combustion Characteristics of a Premixed Burner in a Stirling Engine for a Domestic Cogeneration System (가정용 열병합 스털링 엔진을 위한 예혼합 버너의 연소 특성)

  • Ahn, Joon;Lee, Youn-Sik;Kim, Hyouck-Ju
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.2
    • /
    • pp.211-216
    • /
    • 2012
  • The availability of thermal energy has been widely recognized recently, and the cascade usage of thermal energy from combustion has been encouraged. Within this framework, a 1-kW-class Stirling-engine.based cogeneration system has been proposed as a unit of a distributed energy system. The capacity has been designed to be adequate for domestic usage, which requires high compactness as well as low emissions and noise. To develop a highly efficient system satisfying these requirements, a premixed slot-type short-flame burner has been proposed, and a series of experiments has been performed to understand its combustion characteristics. Flame images have been captured to observe the dependence of the flame mode on the combustion load and air/fuel ratio. The exhaust gas has been sampled and analyzed to study the emission characteristics for each flame mode.

Development of AAS and Determination of metals in airborne particles (원자흡수분광광도계의 제작 및 분진 중 금속성분 분석 비교)

  • Choi, Bae-Jin;Bang, Myung-Sik;Yeo, In-Hyeong
    • Analytical Science and Technology
    • /
    • v.16 no.3
    • /
    • pp.226-231
    • /
    • 2003
  • We analyzed the concentrations of heavy metals associated airbone particles by using AAS made by both a domestic manufacturer and one of the foreign manufacturer. One model developed by a domestic manufacture showed excellent results in the selected wavelength with an excellent performance of a monochromator. It abandons a big drop except a fine drop to improve reproduction in atomizer, so that no remains should leave. Using the low pass filter we were able to reduce a noise of detection signal. The performance of our equipment was found to be highly compatible with that of a foreign company as we achieved the detection limit of about $0.015{\mu}g/L$ using a standard solution of Au. The PM samples had been collected from by main observation points in 7 areas of Seoul city from 2001 to the spring in 2002. with these PM sample we analyzed the concentrations of Pb, Cu, Mn, Cd, Ni, Fe, Cr, Co, Mg and Al.

A Study about Recycling from Municipal Solid Waste Incineration Bottom Ash (생활폐기물(生活廢棄物) 소각(燒却)바닥재의 재활용(再活用)을 위한 연구(硏究))

  • Ahn, Ji-Whan;Oh, Myung-Hwan;Han, Choon
    • Resources Recycling
    • /
    • v.17 no.1
    • /
    • pp.3-11
    • /
    • 2008
  • The treatment of domestic municipal solid waste has inclined to incineration process instead of disposal in landfills. So, the amount of ash generated by incineration of municipal solid waste is gradually increased. The incineration ash divides into bottom ash and fly ash. The bottom ash which accounts for about 90% of the incineration ash consists of ceramics, glasses and metals. And it can be used as the recycling product by the stabilization process. For example, the bottom ash is used as secondary building material or for other similar purposes such as road sub-bases and noise barrier in USA, Europe and Japan. But, the stabilization-treatment technique of bottom ash sti11leaves much to be desired in Korea. Thus, the domestic study of recycling about bottom ash must be improved through investigation about the chemical property and technique of stabilization.

Consideration of Dyslipidemia Examination Cycle Change in Korea National Health Checkup Program (일반건강검진의 이상지질혈증 검진주기 변경에 대한 문제점 고찰)

  • Lee, June-Hee;Lee, Kyung-Jae
    • Health Policy and Management
    • /
    • v.31 no.3
    • /
    • pp.255-260
    • /
    • 2021
  • Background: Korea National Health Checkup Programs are aimed at the prevention and early detection of cardiovascular disease in adults. To establish a countermeasure for this tendency, The current Korea National Health Checkup Programs have been providing Health Risk Appraisal (HRA) since 2009, thereby focusing on individual lifestyle correction. However, from 2018, the dyslipidemia screening exam cycle has been changed from 2 to 4 years. Methods: In this study, we try to investigate whether policy decisions are valid based on domestic reports that have influenced policy decisions. First, considering the epidemiology of the domestic cardiovascular disease, dyslipidemia, and metabolic syndrome, the change of the 4-year cycle is appropriate or not. Second, whether the research method that applies came to make policy decisions appropriate or not. Third, our study also investigates whether the direction of policy decision was suitable for the second comprehensive national examination plan. Results: The data that are used in the previous study were that of 10 years ago and there also was a problem in selecting the data, especially the use of one of the research methods to calculate the signal to noise ratio that was aimed at improving health had some problems. This is a research method that does not match with the aim itself. Conclusion: Changing the screening cycle for dyslipidemia does not match the recent trend of general screening to effectively prevent cardiovascular disease in improving individual lifestyles in the national health checkup plan. Studying the relationship with metabolic syndrome, which can be an intermediate stage of cardiovascular disease, could be a policy direction that is more suitable for the national health examination comprehensive plan.