• Title/Summary/Keyword: Domestic NPPs

Search Result 51, Processing Time 0.022 seconds

Wall Thinning Analyses for Secondary Side Piping of Domestic NPPs Using CHECWORKS Code (CHECWORKS 코드를 이용한 국내 원전 2차계통 배관감육 해석)

  • Hwang, K.M.;Jin, T.E.;Lee, S.H.;Kim, W.S.
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.807-812
    • /
    • 2001
  • This paper represents the wall thinning analysis results for secondary side piping of two types of domestic nuclear power plants based on the DB establishment and F AC analysis study for NPP secondary system piping. CHECWORKS code utilized in this study has been applied world widely to wall thinning analyses for secondary side piping and its reliability has also been proved. The predicted wear rates for several piping systems of a pressurized water reactor NPP are compared with those of a pressurized heavy water reactor NPP and with the measured wear rates. On the basis of comparison results of the predicted and measured wear rates, the analysis results can be effectively applied to the development of a standard thinned pipe management program targeted all domestic nuclear power plants.

  • PDF

Piping Failure Analysis In Domestic Nuclear Safety Piping System (국내 안전등급 배관에 대한 손상사례 분석)

  • Choi, Sun-Yeong;Choi, Young-Hwan
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.617-621
    • /
    • 2003
  • The purpose of this paper is to analyze piping failure trend of safety pipings In domestic nuclear power plants. First, database for the piping failure was constructed with 105 data fields. The database includes plant population data, event data, and service history data. 7 kinds of piping failures in domestic NPPs were investigated. Among the 7 cases, detailed root causes were investigated for 3 cases. The first one is pipe wall thinning in main feedwater pipings of Westinghouse 3 loop type plants. The root cause of the wall thinning was flow accelerated corrosion near welding area. The next one is leak event in chemical and volume control system(CVCS) due to vibration. Some cracks occurred in socket welding area. The events showed that the integrity or socket weld is very vulnerable to vibration. The last one is also a leak event in primary sampling line in Korean standard reactor due to thermal fatigue. Although the structural integrity was not maintained by the events, there was no effect on nuclear safety in the above 3 piping failure eases.

  • PDF

Isolation and Characterization of Humic Acids Present in the Soils at the Vicinity of Domestic Atomic Power Plants(NPPs) (국내 원자력 발전소 주변 토양 휴믹산의 추출 및 특성 규명)

  • Lee, Chang-Hoon;Shin, Hyun-Sang;Chung, Kun-Ho;Cho, Young-Hyun;Lee, Chang-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.28 no.3
    • /
    • pp.165-172
    • /
    • 2003
  • Humic acids present in the soils at the vicinity of domestic atomic power plants(NPPs), located in Yeongkwang(YK), Uljin(UJ), Kori(KR), Koseong(KS), Wolseong(WS) area were isolated, and characterized using elemental analysis and UV/Vis, IR, CPMAS $^{13}C$ NMR spectroscopic methods. The characteristics were compared with one another and with commercial humic acid (Aldrich Co.). Molecular size distributions of the humic acids were determined using a stirred cell ultrafiltration technique. The results of elemental analysis showed that soil humic acid from UJ contains higher oxygen content than humic acids from KR and KS (O/C ratios: 0.51 (UJHA) us. 0.45(KRHA), 0.43(KSHA)). The molecular size distribution revealed that the soil humic acids of UJ and YK contained a higher percentage of larger molecules of > 30,000 daltons, compared to those of KR and KS. The spectral features obtained from UV/vis., IR and CPMAS $^{13}C$ NMR showed that the aromatic character and oxygen containing functional groups in the humic acids from UJ and YK were relatively higher than those of KR and KS. These results indicate that the soil humic acids from UJ and YK were in a higher degree of humification, which may suggest higher affinity of the humic acids with radionuclides released in the soil environments.

Preliminary Study on the Internal Dosimetry Program for Carbon-14 at Korean CANDU Reactors (중수로원전에서 발생하는 $^{14}C$에 대한 내부피폭 선량평가 프로그램에 관한 예비 조사)

  • Kong T.Y.;Kim H.C.;Park G.;Hang D.W.;Lee G.J.;Lee S.K.;Park S.C.
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2005.11a
    • /
    • pp.317-320
    • /
    • 2005
  • More strict radioactive regulations are applied to Korean nuclear power plants (NPPs) since ICRP-60 recommendation for radiation protection and has been enforced since 2003. In particular. carbon-14 and tritium concentrations are significantly higher at CANDU reactors compared to PWR reactors and this increases the risk of internal radiation exposure to workers at CANDU NPPs. Thus, it is necessary to estimate the exact amount of internal radiation exposure to workers fur radiological protection at CANDU reactors. In this paper, the current dosimetry method for carbon-14 is analyzed for the establishment of internal dosimetry for carbon-14 at domestic NPPs.

  • PDF

Development of Safety Review Guide for Periodic Safety Review of Reactor Vessel Internals (원자로내부구조물 주기적 안전성평가 심사지침 개발 배경)

  • Lee, Ki Hyoung;Park, Jeong Soon;Ko, Han Ok;Jhung, Myung Jo
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.9 no.1
    • /
    • pp.20-24
    • /
    • 2013
  • Reactor Vessel Internals(RVIs), which are installed within the reactor pressure vessel and support the fuel assembly, take responsibility for safety of reactor core. In operating Nuclear Power Plants(NPPs), the RVIs have been exposed to severe conditions such as neutron irradiation, high temperature, high pressure, and high velocity of coolant flow and have degraded by materials aging with long-term operation. Therefore, the effective aging management plan and the appropriate regulatory requirements are necessary to maintain the integrity of RVIs. The purpose of this paper is to provide a review guide for Periodic Safety Review(PSR) of RVIs in presurized water reactor. The review guide is developed based on the revised review guides and reports established from IAEA and USNRC, and the analysis results of design characteristics, aging mechanisms, and operating experiences of RVIs in domestic and international NPPs. Consequently, the developed review guide for PSR of RVIs is expected to contribute an overall strategy and standard for the PSR of RVIs.

Effects of Outside Repair Welding on the Crack Growth in the Surge Nozzle Weld on the Hot Leg Side in a Nuclear Power Plant (외면 보수 용접이 원전 고온관 밀림노즐에서의 결함성장에 미치는 영향)

  • Na, Kyung-Hwan;Yun, Eun-Sub;Park, Young-Sheop
    • Journal of Welding and Joining
    • /
    • v.29 no.2
    • /
    • pp.34-39
    • /
    • 2011
  • Nickel-based austenitic alloys such as Alloy 82 and 182 had been employed as the weld metals in nuclear power plants (NPPs) due to their high corrosion resistance as well as good mechanical properties. However, since the 2000s, the occurrence of primary water stress corrosion cracking has been reported in conjunction with these alloys in domestic and oversea NPPs. In the present work, we assumed an imaginary crack at the inner surface of a surge nozzle weld that had previously experienced the outside repair welding, and constructed its finite element model. Finite element analysis was performed with respect to the heat transfer, and then to the residual stress for obtaining the total applied stress distributions. These stress distributions were finally converted to the stress intensity factors for estimating crack growth rate. From the comparison of crack growth rate curves for the cases of no repair welding and outside repair welding, it was found that the outside repair welding did not exhibit negative effect on the crack growth for the surge nozzle under consideration in this work; in both cases, the cracks stopped growing before they became the through-wall cracks.

Feasibility Study on Cross-tie Systems in Nuclear Power Plants Using Multi-unit PSA (다수기 PSA를 활용한 원전 안전자원 공유 활용성 평가)

  • Jong Woo Park;Ho-Gon Lim;Jae Young Yoon
    • Journal of the Korean Society of Safety
    • /
    • v.38 no.3
    • /
    • pp.102-109
    • /
    • 2023
  • Following the accident at Fukushima, the true impact of multi-unit accidents came to light. Accordingly, research related to multi-unit accident effect analysis, risk evaluation, and accident prevention/prevention technology has been conducted. Specific examples are mobile/fixed equipment such as multi-barrier accident coping strategy (MACST) and diverse and flexible coping strategies (FLEX), which have been introduced and installed in multi-units for preventing and mitigating multi-unit accidents. These strategies are useful for enhancing the safety of nuclear power plants (NPPs); however, a more efficient strategy is required in terms of the costs of physical and human resources. To effectively and efficiently mitigate an increase in multi-unit accidents, it is necessary to not only to utilize mobile/fixed equipment but to also use crosstie options with resources that already exist at NPPs. Therefore, we analyzed the current international and domestic status of crosstie systems technology and propose a method to evaluate feasibility alongside risk based on a multi-unit probabilistic safety assessment (PSA). To analyze the international and domestic status of crosstie systems technology, actual cases and related research were studied, and a list of potential crosstie safety resources was derived. Additionally, a case study was performed on crosstie cases of two systems within the assumed six units on-site under a multi-unit accident, and a multi-unit PSA-based risk evaluation method is proposed.

Determination of Availability of Domestic Developed Bobbin Probe for Steam Generator Tube Inspection (증기발생기 전열관 와전류검사용 국내 개발 보빈탐촉자 적용성 분석)

  • Kim, In-Chul;Joo, Kyung-Mun;Moon, Yong-Sig
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.7 no.4
    • /
    • pp.19-25
    • /
    • 2011
  • Steam Generator(SG) tube is an important component of Nuclear Power Plant(NPP), which is the pressure boundary between the primary and secondary systems. The integrity of SG tube has been confirmed by the eddy current test every outage. The eddy current technique adopting bobbin probe is currently the primary technique for the steam generator tubing integrity assesment. The bobbin probe is one of the essential components which consist of the whole ECT examination system and provides us a decisive data for the evaluation of tube integrity. Until now, all of the ECT bobbin probes in Korea which is necessary to carry out inspection are imported from overseas. However, KHNP has recently developed the bobbin probe design technology and transferred it to domestic manufacturers to fabricate the probes. This study has been conducted to establish technical requirements applicable to the steam generator tube inspection using the bobbin probes fabricated by the domestic manufactures. The results have been compared with the results obtained by using foreign probe to identify the availability to the steam generator tube inspection. As a result, it is confirmed that the domestic bobbin probe is generally applicable to SG tube inspection in the NPPs.

A Study on the Application of CRUDTRAN Code in Primary Systems of Domestic Pressurized Heavy-Water Reactors for Prediction of Radiation Source Term

  • Song, Jong Soon;Cho, Hoon Jo;Jung, Min Young;Lee, Sang Heon
    • Nuclear Engineering and Technology
    • /
    • v.49 no.3
    • /
    • pp.638-644
    • /
    • 2017
  • The importance of developing a source-term assessment technology has been emphasized owing to the decommissioning of Kori nuclear power plant (NPP) Unit 1 and the increase of deteriorated NPPs. We analyzed the behavioral mechanism of corrosion products in the primary system of a pressurized heavy-water reactor-type NPP. In addition, to check the possibility of applying the CRUDTRAN code to a Canadian Deuterium Uranium Reactor (CANDU)-type NPP, the type was assessed using collected domestic onsite data. With the assessment results, it was possible to predict trends according to operating cycles. Values estimated using the code were similar to the measured values. The results of this study are expected to be used to manage the radiation exposures of operators in high-radiation areas and to predict decommissioning processes in the primary system.

Analysis of Source Terms at Domestic Nuclear Power Plant with CZT Semiconductor Detector (CZT 반도체 검출기를 이용한 국내 원전 내 선원항 분석)

  • Kang, Seo Kon;Kang, Hwayoon;Lee, Byoung-Il;Kim, Jeong-In
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.1
    • /
    • pp.14-20
    • /
    • 2014
  • A lot of radiation exposure for radiation workers who are engaged in Nuclear Power Plants, especially PWRs, have been caused during the outage by CRUD, such as $^{58}Co$, $^{60}Co$, in Reactor Coolant System. And therefore we need to know source terms to achieve optimization of protection for the radiation workers from radiation exposure at Nuclear Power Plants efficiently. This study analyzed source terms at domestic NPPs (PWRs) nearby Steam Generator with CZT semiconductor detector using by IN-VIVO method during the outage for the first time in the country. We checked difference for the detected source terms between old and new NPP. It was performed especially to see a change of source terms by water chemistry process as well. There was not any difference by water chemistry process both NPPs. The main source terms are $^{58}Co$ and $^{60}Co$ at all NPPs. $^{59}Fe$ only appears in the new NPP. $^{137}Cs$ and $^{95}Zr$ are shown in the old NPP. The fraction of $^{58}Co/^{60}Co$ in the new NPP is higher than the old NPP for increasing the specific activity of $^{60}Co$.