• Title/Summary/Keyword: Dividing flow

Search Result 152, Processing Time 0.029 seconds

Impacts of Nitrate in Base Flow Discharge on Surface Water Quality (질산성 질소 기저유출이 지표수 수질에 미치는 영향)

  • Kim, Geonha;Lee, Hosik
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.1B
    • /
    • pp.105-109
    • /
    • 2009
  • It is a well known fact that baseflow discharge of rainfall runoff impacts on water quality of surface water significantly. In this paper, impacts of nitrate discharged as base flow on stream water quality were studied by using a software, PULSE from USGS to calculate monthly ground water discharge from hydrograph. We used water quality and flow rate data for Ghapcehon2 site in Daejeon city for year 2005 as well as ground water quality data in the watershed acquired from government agencies. Agricultural and forestry land use are dominant for upstream of Ghapcheon2 in the watershed. Base flow contributes about 85~95% of stream flows during spring and fall while 25~38% of stream flow was induced by base flow during summer and winter. Monthly nitrate loading discharged as base flow for Ghapcheon2 was estimated by using averaged nitrate concentration of groundwater in the watershed. Nitrate loading induced by base flow at Ghapcheon2 was estimated as 5.4 ton of $NO_{3}{^-}-N/km^{2}$, which is about 60% of nitrate loading of surface water, 9.2 ton of $NO_{3}{^-}-N/km^{2}$. Seasonal variation of nitrate concentration of base flow was estimated by dividing monthly nitrate loading by monthly base flow discharge. Nitrate concentration of groundwater was increasing from rainy season. From this study, it can be understood that ground water quality monitoring is important for the proper manage of surface water quality.

The Experimental Analysis of Aerodynamic Sound for Fan Motor in a Vacuum Cleaner Using Laser 3-D Scanning Vibrometer and Microphone (레이저 3차원 진동측정기와 마이크로폰을 이용한 진공청소기용 팬모터의 실험적인 공력소음 분석)

  • Kwac Lee-Ku;An Jae-Sin;Kim Jae-Yeol
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.3 s.168
    • /
    • pp.46-51
    • /
    • 2005
  • The vacuum cleaner motor runs at very high speed for suction power. Specially, motor power is provided by the impeller being rotated at very high speed. The centrifugal fan consists of the impeller, the diffuser, and the circular casing. Due to the high rotating speed of the impeller and small gap distance between the impeller and the diffuser, the level of noise in the centrifugal fan is at BPF(Blade Passage Frequency) and its harmonic frequencies. In order to calculate the sound pressure of centrifugal fan, unsteady flow data are needed. The cause of noise is obtained by dividing the fluid noise by exhaust flow of fan and vibration noise by rotational vibration of vacuum cleaner fan motor. Until now, an accelerometer has been used to measure vibration. However, it can not measure vibration in some parts of brush and commutator because of motor construction and 3-D vibrating mode. This study was conducted to perform accurate analysis of vibration and aerodynamic sound for fan motor in a vacuum cleaner using a laser vibration analyzer. A silent fan motor can be designed using the data measured in this study.

A Study on the Architectural Planning in Mixed-use Tendency for Educational Facilities - The case of a plan analysis in Educational Facilities(Korea/Japan) - (학교(學校) 시설(施設) 복합화(複合化)에 관한 건축계획적(建築計劃的) 연구(硏究) - 학교(學校)(한국, 일본(韓國, 日本))의 평면(平面) 분석(分析)을 중심(中心)으로 -)

  • Rieu, Ho-Seoup;Shin, Il-Yong
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.7 no.3
    • /
    • pp.15-22
    • /
    • 2000
  • The purpose of this study is to grasp a concept for mixed-use tendency of educational facilities, its propellant circumstance in the nation and japan, to analyze a feature of a function, a flow planing of user and the complex form which appear from an instance of the mixed-use tendentious educational facilities and is to suggest a basic matter on the architectural planning for mixed-use tendency of the regional facilities and educational facilities. The results of the study can be summarized were as follow: 1) The step of mixed-use in nation is yet the early step and a extremely feeble to compared with the japan. 2) In a case of the mixed-use tendency facility, the nation is to appear for the necessity of a region but they know of a varied facility to be mixed-use tendency in japan. 3) Much to appear monolithic form in the side of complex form. 4) To appear multi-story in the side of facility-story. 5) It is much example of separating from main entrance, the flow of interior found of dividing into not to transit or transit by the function of facility. 6) To know for being tendency of common and division by the principal of user in facility instituting E V.

  • PDF

CFD analysis of ventilation efficiency around an elevated highway using visitation frequency and purging flow rate

  • Huang, Hong;Kato, Shinsuke;Ooka, Ryozo;Jiang, Taifeng
    • Wind and Structures
    • /
    • v.9 no.4
    • /
    • pp.297-313
    • /
    • 2006
  • The concentration of air pollution along roads is higher than the surrounding area because ventilation efficiency has decreased due to the high-density use of space along roads in recent years. In this study, ventilation efficiency around a heavily traffic road covered by an elevated highway and hemmed in along its side by buildings is evaluated using Visitation Frequency (VF, the frequency for pollutant to return to the objective domain) and Purging Flow Rate (PFR, the air flow rate for defining the local domain-averaged concentration). These are analyzed using Computational Fluid Dynamics (CFD) based on the standard $k-{\varepsilon}$ model. The VF and PFR characteristics of four objective domains are analyzed in terms of the changes in wind direction and arrangements of the fencing dividing up and down direction in the road center under the elevated highway. The resulting VFs are more than 1.0 for all cases, which means that pollutants return to the objective domain restricted by the elevated highway and side buildings. The influence of the arrangement of the buildings around the objective domain and the structure in the domain on the VF is substantial. In cases where there are no obstacles under the elevated highway, the local air exchange rate in the domain tends to be improved. Using these indices, the urban ventilation efficiencies between different urban areas can be compared easily.

Usefulness of Reverse Flow Prevention Valves for Back-flow Prevention of Gadolinium Based Contrast Agent in Dynamic Examination of Magnetic Resonance Imaging (자기공명영상 동적검사 시 조영제 역류방지용 밸브의 유용성)

  • Son, Soon-Yong
    • The Journal of the Korea Contents Association
    • /
    • v.20 no.6
    • /
    • pp.439-444
    • /
    • 2020
  • The purpose of this study is to seek an alternative method to prevent the contamination of normal saline caused by the back-flow of Gadolinium Based Contrast Agent(GBCA) by the use of auto-injector for dynamic MRI. The research method is to manufacture the non-return valve as an alternative to the existing, and to examine the usefulness of the normal saline by dividing the state of normal saline into three groups. The signal intensity were compared. As a result, there was no statistically significant difference between normal saline before injection of group 1 and group 3 non-return valve (p> 0.05). It is analyzed that the self-produced non-return valve completely blocked the GBCA back to normal saline when the GBCA was injected. In conclusion, the application of the non-return valve presented in this study for dynamic MRI imaging using the auto injector can prevent normal saline contamination due to GBCA back-flow.

A study on the flow characteristics in a MILD combustion waste incinerator with the change of flue gas recirculation inlet location (MILD 연소 폐기물 소각로에서 배기가스 재순환 흡입구 위치에 따른 유동 특성 연구)

  • Ha, Ji Soo;Shim, Sung Hun;Jung, Eung Ho
    • Journal of Energy Engineering
    • /
    • v.23 no.3
    • /
    • pp.51-57
    • /
    • 2014
  • A MILD(Moderate and Intense Low oxygen Dilution) combustion, which is effective in the reduction of NOx, is considerably affected by the recirculation flow position of hot exhaust gas to the combustion furnace. A numerical analysis was accomplished to elucidate the flow characteristics in the MILD combustion incinerator for several cases with or without exhaust gas recirculation. It could be seen from the result of the present numerical study that the flow recirculation could be observed in the upper region over the vertical dividing wall for the case without exhaust gas recirculation. The optimal position of exhaust gas recirculation position was derived by the comparison of %RMS of x directional velocity for the cases with exhaust gas recirculation. The case with the exhaust gas recirculation position at the upper right of free board was the most effective with the smallest value of 57.4% RMS.

Modeling of Parasitic Source/Drain Resistance in FinFET Considering 3D Current Flow (3차원적 전류 흐름을 고려한 FinFET의 기생 Source/Drain 저항 모델링)

  • An, TaeYoon;Kwon, Kee-Won;Kim, SoYoung
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.10
    • /
    • pp.67-75
    • /
    • 2013
  • In this paper, an analytical model is presented for the source/drain parasitic resistance of FinFET. The parasitic resistance is a important part of a total resistance in FinFET because of current flow through the narrow fin. The model incorporates the contribution of contact and spreading resistances considering three-dimensional current flow. The contact resistance is modeled taking into account the current flow and parallel connection of dividing parts. The spreading resistance is modeled by difference between wide and narrow and using integral. We show excellent agreement between our model and simulation which is conducted by Raphael, 3D numerical field solver. It is possible to improve the accuracy of compact model such as BSIM-CMG using the proposed model.

Hydraulic Characteristics of Branching and Merging of Channels in Regenerative Cooling Passage in Liquid Rocket Combustors (채널의 분기 및 병합이 있는 액체로켓 연소기 재생냉각 유로에서의 수력학적 특성)

  • Kim, Hong-Jip;Kim, Seong-Ku;Choi, Hwan-Seok
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.36 no.11
    • /
    • pp.1087-1093
    • /
    • 2008
  • Regenerative cooling passage to guarantee the thermal survivability in high performance rocket engine combustors could have complex configurations of the branching/merging of channels and flow turning, etc. By applying the classical hydraulic coefficients which can be found in the literature according to the flow conditions, hydraulic characteristics in regenerative cooling passages can be obtained effectively through dividing the pressure loss into friction loss and local resistance loss. Satisfactory agreement has been obtained by comparing the present results with experimental measurement of water flow test. In addition, the present results were in good agreement with CFD results when the actual coolant, kerosene was used. Therefore, the application of the present method is expected to be useful to design regeneratively cooled combustors.

Analysis of News Big Data for Deriving Social Issues in Korea (한국의 사회적 이슈 도출을 위한 뉴스 빅데이터 분석 연구)

  • Lee, Hong Joo
    • The Journal of Society for e-Business Studies
    • /
    • v.24 no.3
    • /
    • pp.163-182
    • /
    • 2019
  • Analyzing the frequency and correlation of the news keywords in the modern society that are becoming complicated according to the time flow is a very important research to discuss the response and solution to issues. This paper analyzed the relationship between the flow of social keyword and major issues through the analysis of news big data for 10 years (2009~2018). In this study, political issues, education and social culture, gender conflicts and social problems were presented as major issues. And, to study the change and flow of issues, it analyzed the change of the issue by dividing it into five years. Through this, the changes and countermeasures of social issues were studied. As a result, the keywords (economy, police) that are closely related to the people's life were analyzed as keywords that are very important in our society regardless of the flow of time. In addition, keyword such as 'safety' have decreased in increasing rate compared to frequency in recent years. Through this, it can be inferred that it is necessary to improve the awareness of safety in our society.

Numerical study of dividing open-channel flows at bifurcation channel using TELEMAC-2D (TELEMAC-2D모형을 이용한 개수로 분류흐름에 대한 수치모의 연구)

  • Jung, Dae Jin;Jang, Chang-Lae;Jung, Kwansue
    • Journal of Korea Water Resources Association
    • /
    • v.49 no.7
    • /
    • pp.635-644
    • /
    • 2016
  • This study investigates variation of flow characteristics due to variation of branch channel width and discharge ratio at bifurcation channel using 2D numerical model. The calculated result considering secondary flow is more accurate and stable than without considering one. The diversion flow rate ($Q_3/Q_1$) is reduced by flow stagnation effect according to the interaction of the secondary flow and flow separation zone in branch channel. The less upstream inflow or the lower upstream velocity, the bigger variation of diversion flow rate by changing branch channel width. At uniform downstream boundary condition, the rate of change in Froude number of downstream of main channel($Fr_2$)-diversion flow rate ($Q_3/Q_1$) relations is similar about -2.4843~-2.6675 when branch channel width ratio (b/B) is decreased. At uniform diversion flow rate ($Q_3/Q_1$) condition, the width of recirculation zone in branch channel is decreased when branch channel width ratio (b/B) is decreased. The less upstream inflow in the case of increasing branch channel width or the narrower branch channel width in the case of increasing upstream inflow, the bigger reduction ratio of recirculation zone width. At uniform inflow discharge ($Q_1$) condition, diversion flow rate, the width and length of recirculation zone in branch channel are decreased when branch channel width ratio (b/B) is decreased.