• Title/Summary/Keyword: Disturbance function

Search Result 581, Processing Time 0.024 seconds

H-infinity controller design for robust speed control against disturbance and model uncertainty of DC motors (외란과 모델 불확실성에 강인한 DC모터의 속도 제어용 H-infinity 제어기 설계)

  • JEONG, Tae-Young;KIM, Dong-Geun
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.58 no.3
    • /
    • pp.241-250
    • /
    • 2022
  • This paper describes the design of H-infinity controller for robust control of a DC motor system. The suggested controller can ensure robustness against disturbance and model uncertainty by minimizing H-infinity norm of the transfer function from exogenous input to performance output and applying the small gain theorem. In particular, the controller was designed to reduce the effects of disturbance and model uncertainty simultaneously by formalizing these problems as a mixed sensitivity problem. The validity of the proposed controller was demonstrated by computer simulations and real experiments. Moreover, the effectiveness of the proposed controller was confirmed by comparing its performance with PI controller, which was tested under the same experimental condition as the H-infinity controller.

Power Disturbance Detection using the Inflection Point Estimation (변곡점 추정을 이용한 전력선 신호의 이상현상 검출)

  • Iem, Byeong-Gwan
    • Journal of IKEEE
    • /
    • v.25 no.4
    • /
    • pp.710-715
    • /
    • 2021
  • Power line signal can show disturbances due to various causes. Typical anomalies are temporary sag/swell of the amplitude, flat topped signal, and harmonic distortions. The disturbances need to be detected and treated properly for the quality of the power signal. In this study, the power disturbances are detected using the inflection points (IP). The inflection points are defined as points where local maxima/minima or the slope changes occur. The power line signal has a fixed IP pattern since it is basically sinusoidal, and it may have additional inflection points if there is any disturbance. The disturbance is detected by comparing the IP patterns between the normal signal and distorted signal. In addition, by defining a cost function, the time instant where the disturbance happens can be decided. The computer simulation shows that the proposed method is useful for the detection of various disturbances. The simple sag or swell signal only shows the amplitude changes at the detected inflection points. However, the flat top signal and harmonically distorted signal produce additional inflection points and large values in the cost function. These results can be exploited for the further processing of disturbance classification.

Recognition and Classification of Power Quality Disturbances on the basis of Pattern Linguistic Values

  • Liu, XiaoSheng;Liu, Bo;Xu, DianGuo
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.2
    • /
    • pp.309-319
    • /
    • 2016
  • This paper presents a new recognition and classification method for power quality (PQ) disturbances on the basis of pattern linguistic values. This method solves the difficulty of recognizing disturbances rapidly and accurately by using fuzzy logic. This method uses classification disturbance patterns to define the linguistic values of fuzzy input variables and used the input variables of corresponding disturbance pattern to set membership functions. This method also sets the fuzzy rules by analyzing the distribution regularities of the input variable values. One characteristic of this method is that the linguistic values of fuzzy input variables and the setting of membership functions are not only related to the input variables but also to the character of classification disturbance and the classification results. Furthermore, the number of fuzzy rules is equal to the number of disturbance patterns. By using this method for disturbance classification, the membership function and design of fuzzy rules are directly related to the objective of classification, thus effectively reducing the complexity of the design process and yielding accurate classification results. The classification results of the simulation and measured data verify the feasibility and effectiveness of this method.

Robust Control for the Rewritable Optical Disk Drives with Sinusoidal Disturbance of Uncertain Frequencies (불확실한 주파수의 정현파 외란이 있는 기록형 광 디스크 드라이브의 강인 제어)

  • Lee, Moon-Noh;Jin, Kyoung-Bog;Moon, Jung-Ho
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.8 no.8
    • /
    • pp.682-690
    • /
    • 2002
  • This paper presents an output feedback controller design method for uncertain linear systems with sinusoidal disturbance of uncertain frequencies. The controller needs to compensate for the performance deterioration due to the uncertain frequencies of sinusoidal disturbance. To this end, we introduce a virtual system including the dynamics corresponding to the uncertain frequencies and design a controller which minimizes the output difference between the virtual system and the closed-loop system. In other words, the controller is designed so that the closed-loop system approximates the virtual system. The feedback controller is achieved by solving an LMI optimization problem involving a robust $H_{\infty}$ constraint. The advantages of the proposed design method are examined by comparing it with a design method that only minimizes the $H_{\infty}$ norm of the transfer function between the sinusoidal disturbance and the output. The proposed design method is applied to the track-following system of rewritable optical disk drives and is evaluated through an experiment.

Design of control system with two degrees of freedom based on the disturbance observer (외란관측기 기반한 2 자유도 제어계의 설계)

  • Ha, Hong-Gon
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.11 no.1
    • /
    • pp.74-79
    • /
    • 2010
  • Many control techniques have been purposed in order to improve the control performances of the control system. The freedom on control in the control system is decided by the number of the closed-loop transfer function which can adjust independently. The design method of the controller with two degrees of freedom(TDOF) is used extensively for following the desired value and rejecting the disturbance. In this paper, the control system with the disturbance observer(DOB) for rejecting the disturbance is transformed by the control system with TDOF and the rejection of a transient response is easy at the starting time and load variation. The design method of the DOB is proposed in the frequency-domain and the control system with TDOF is constructed by using the DOB which is designed with this method. Through the simulation results, the usefulness of the proposed algorithm is proved.

State space disturbance observer based controller design for self servo writing (셀프 서보 라이팅을 위한 상태공간 외란 관측기 기반의 제어기 설계)

  • Jung, Youn-Sung;Kang, Hyun-Jae;Lee, Choong-Woo;Chung, Chung-Choo;Cho, Kyu-Nam;Suh, Sang-Min;Oh, Dong-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2007.10a
    • /
    • pp.129-130
    • /
    • 2007
  • Self servo track writing(SSTW)은 servo track writer(STW)를 이용하지 않고 hard disk drive의 내부 VCM을 이용하여 servo track을 기록하는 방식이다. SSTW는 이전 servo track을 상대적인 reference로 하여 기록하게 되므로 초기에 발생된 error와 외부의 disturbance의 영향으로 error는 급속하게 증가된다. 이것을 radial error propagation 이라 한다. 본 논문에서는 radial error propagation을 억제하기 위한 correction signal을 설계하고 servo writing 과정에서 발생하는 disturbance의 영향을 제거하기 위하여 disturbance observer(DOB)를 add-on type으로 구성하여 tracking 제어기를 설계하였다. 또한 DOB를 적용한 경우와 유사한 gain margin, phase margin과 sensitivity function을 갖는 제어기를 설계하여 그 성능을 비교하였다. 제안된 방식은 radial error propagation을 억제 하였을 뿐만 아니라 disturbance의 최소화하여 쓰여진 track의 DC track spacing과 AC track Squeeze가 개선된 것을 모의실험을 통하여 검증하였다.

  • PDF

A Study on Physical, Cognitive, and Social Functioning Levels in Institutionalized elderly (요양원 노인의 신체적, 인지적, 사회적 기능상태에 관한 연구)

  • Kim, Jung-Soon;Kwon, Ja-Youn
    • Research in Community and Public Health Nursing
    • /
    • v.7 no.2
    • /
    • pp.216-228
    • /
    • 1996
  • The purposes of this study were to investigate levels of physical, cognitive, and social functioning in institutionalized elderly. The subjects were 78 residents of a nursing home for the elderly in Pusan. The data were collected from June 24th to July 8th, 1996 using interview and observational method. The structured questionnaires developed by Kim, by Kwon & Park, and by researcher were adopted to measure physical, cognitive, and social function, respectively. The data were analyzed using percentages, means, t test, ANOVA, Pearson correlation coefficient, Cronbach's alpha with the SPSS PC programs. The results were summarized as follows: 1. 34.2% of the subjects had a paralysis, strokes 26.3%, hearing impairment 15.9%, vision impairment 11.8%, mental disturbance 11.8%, cognitive disturbance 10.5%. 2. The mean score on the physical function for the subjects was 73.14, and the items with low functioning levels were 'ascending the stairs', 'bathing' in that order. There was no significant difference in physical function according to the following demographic characteristics: sex, age, and education level. 3. 50.0% of subjects was categorized 'definite dementia', 'questionable dementia' 11.5%, 'definite non-dementia' 38.5%. There was a significant difference in cognitive function according to sex, but were no significant differences according to following demographic characteristics: age and education level. 4. The mean score on the social function for the subjects was 17.60. The items with comparatively high score were in simple activities such as 'enjoying talking with his friends', 'watching TV or listening to the radio', and the items with low score were in complex activities such as 'enjoying a hobby',. 'enjoying a game', 'reading the newspaper or book'. There were no significant differences in social function according to sex and age, but was a significant difference according to education level. 5. Social function was positively correlated with both physical function and cognitive function.

  • PDF

Combined Optimal Design of Flexible Beam with Sliding Mode Control System

  • Park, Jung-Hyen;Kim, Soon-Ho
    • Journal of Ocean Engineering and Technology
    • /
    • v.17 no.4
    • /
    • pp.59-65
    • /
    • 2003
  • In order to achieve the desired lightweight and robust design of a structure, it is preferable to design a structure and its control system, simultaneously, which is termed the combined optimal design. A constant-cross-sectional area cantilever beam was chosen as the optimum design method, An initial load and a time-varying disturbance were applied at the free end of the beam. Sliding mode control was selected, due to its insensitivity to the disturbance, compared with other modes. It is known that the sliding mode control is robust to the disturbance and is uncertain, only if a matching condition is met, after giving a switching hyper plane. In this study, the optimum method was used for the design of the switching hyper plane, and the objective function of the optimum switching hyper plane was assumed to be the objective of the control system. The total weight of the structure was treated as a constraint, and the cross sectional areas of the beam were considered as design variables, the result being a nonlinear programming problem. To solve it, the sequential linear programming method was applied. As a result of the optimum design, the effect of attenuating vibrations has been substantially improved. Moreover, the lightweight design of the structure became possible as a result of the relationship of the weight of the structure to the control objective function.

Combined Optimal Design of Structure-Control Systems by Sliding Mode Control (슬라이딩모드 제어 기법을 이용한 구조-제어 시스템의 통합 최적 설계)

  • Park, Jung-Hyeon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.10
    • /
    • pp.45-51
    • /
    • 2002
  • To achieve the lightweight and robust design of a structure, it is requested to design a structure and its control system simultaneously, which is called as the combined optimal design. A constant-cross-sectional area cantilever beam was chosen as an example for the applying the optimum design method. An initial load and a time varying disturbance were applied at the free end of the beam. Sliding mode control was selected due to its insensitiveness to the disturbance compared with other modes. It is known that the sliding mode control is robust to the disturbance and the uncertainty only if a matching condition is met, after giving a switching hyper plane. In this study, the optimum method was used for the design of the switching hyper plane and the objective function of the optimum switching hyper plane was assumed to be the objective one of the control system. The total weight of the structure was treated as a constraint and the cross sectional areas of the beam were considered as design variables, which means a nonlinear programming problem. The sequential linear programming method was applied to solve it. As a result of the optimum design, the effect of attenuating vibrations has been improved obviously. Moreover, lightweight design of the structure became possible from the relationship of the weight of the structure and the control objective function.

Genetic algorithm-based design of a nonlinear PID controller for the temperature control of load-following coolant systems (부하추종 냉각수 시스템의 온도 제어를 위한 유전알고리즘 기반 비선형 PID 제어기 설계)

  • Yu-Soo, LEE;Soon-Kyu, HWANG;Jong-Kap, AHN
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.58 no.4
    • /
    • pp.359-366
    • /
    • 2022
  • In this study, the load fluctuation of the main engine is considered to be a disturbance for the jacket coolant temperature control system of the low-speed two-stroke main diesel engine on the ships. A nonlinear PID temperature control system with satisfactory disturbance rejection performance was designed by rapidly transmitting the load change value to the controller for following the reference set value. The feed-forwarded load fluctuation is considered the set points of the dual loop control system to be changed. Real-coded genetic algorithms were used as an optimization tool to tune the gains for the nonlinear PID controller. ITAE was used as an evaluation function for optimization. For the evaluation function, the engine jacket coolant outlet temperature was considered. As a result of simulating the proposed cascade nonlinear PID control system, it was confirmed that the disturbance caused by the load fluctuation was eliminated with satisfactory performance and that the changed set value was followed.