• 제목/요약/키워드: Disturbance Source

Search Result 135, Processing Time 0.027 seconds

Disturbance due to internal heat source in thermoelastic solid using dual phase lag model

  • Ailawalia, Praveen;Singla, Amit
    • Structural Engineering and Mechanics
    • /
    • v.56 no.3
    • /
    • pp.341-354
    • /
    • 2015
  • The dual-phase lag heat transfer model is employed to study the problem of isotropic generalized thermoelastic medium with internal heat source. The normal mode analysis is used to obtain the exact expressions for displacement components, force stress and temperature distribution. The variations of the considered variables through the horizontal distance are illustrated graphically. The results are discussed and depicted graphically.

Calculation of Wave-making Resistance using Neumann-Kelvin Theory (Neumann-Kelvin 이론을 사용한 조파저항 계산)

  • S.J. Kim;S.J. Lee
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.29 no.3
    • /
    • pp.71-79
    • /
    • 1992
  • In order to obtain the wave-making resistance of a ship, so-called the Neumann-Kelvin problem is solved numerically. For computing the Havelock source, which is the Green's function of the problem, we adopted the methods given by Newman(1987) for the term representing the local disturbance, and Baar and Price(1988) for the wave disturbance, respectively. In the numerical code we developed, the source strength is assumed as bilinear on each panel and continuous throughout the hull surface. The wave-making resistance is calculated using the algorithm of de Sendagorta and erases(1988), which makes use of the wave amplitude far downstream. The Wigley hull was chosen for the sample calculation, and our results showed a good agreement with other existing experimental and numerical results.

  • PDF

Noise in hospital rooms and sleep disturbance in hospitalized medical patients

  • Park, Marn Joon;Yoo, Jee Hee;Cho, Byung Wook;Kim, Ki Tae;Jeong, Woo-Chul;Ha, Mina
    • Environmental Analysis Health and Toxicology
    • /
    • v.29
    • /
    • pp.6.1-6.6
    • /
    • 2014
  • Objectives Hospitalized patients are vulnerable to sleep disturbances because of environmental stresses including noise. While most previous studies on hospital noise and sleep have been performed for medical machines in intensive care units, there is a limited data for patients hospitalized in medical wardrooms. The purpose of present study was to measure noise level of medical wardrooms, identify patient-perceived sources of noise, and to examine the association between noise levels and sleep disturbances in hospitalized patients. Methods Noise dosimeters were used to measure noise level in 29 inpatient wardrooms at a university hospital. Sleep pattern and disturbance were assessed in 103 hospitalized patients, using the Pittsburgh Sleep Quality Index (PSQI) and Leeds Sleep Evaluation Questionnaire. Results The mean equivalent continuous noise level for 24 hours was 63.5 decibel A (dBA), which was far higher than 30 dBA recommended by the World Health Organization for hospital wardrooms. Other patients sharing a room were perceived as the most common source of noise by the patients, which was usually preventable. Of the patients in the study, 86% had bad sleep as assessed by the PSQI. The sleep disturbance was significantly correlated with increasing noise levels in a dose response manner. Conclusions Systemic organizational interventions are needed to keep wardrooms private and quiet to reduce sleep disturbance.

Countermeasure on High Vibration of Branch Pipe with Pressure Pulsation Transmitted from Main Steam Header (주증기 배관 헤더의 압력맥동에 대한 분기 배관의 고진동 대책)

  • Kim, Yeon-Whan;Bae, Yong-Chae;Lee, Young-Shin
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.8 s.101
    • /
    • pp.988-995
    • /
    • 2005
  • Vibration has been severly increased at the branch pipe of main steam header since the commercial operation of nuclear power plant. Intense broad band disturbance flow at the discontinuous region such as elbow, valve, and header generates the acoustical pulsation which is propagated through the piping system. The pulsation becomes the source of low frequency vibration at piping system. If it coincide with natural frequency of the pipe system, excessive vibration is made. High level vibration due to the pressure pulsation related to high dynamic stress, and ultimately, to failure probability affects fatally the reliability and confidence of plant piping system. This paper discusses vibration effect for the branch pipe system due to acoustical pulsations by broad band disturbance flow at the large main steam header in 700 MW nuclear power plant. The exciting sources and response of the piping system are investigated by using on-site measurements and analytical approaches. It is identified that excessive vibration is caused by acoustical pulsations of 1.3 Hz, 4.4 Hz and 6.6 Hz transmitted from main steam balance header, which are coincided with fundamental natural frequencies of the piping structure. The energy absorbing restraints with additional stiffness and damping factor were installed to reduce excessive vibration.

Vibration Effect for Branch Pipe System due to Main Steam Header Pulsation (주증기 배관 헤더의 맥동이 분기 배관에 미치는 영향)

  • Kim, Yeon-Whan;Bae, Yong-Chae;Lee, Hyun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.780-785
    • /
    • 2005
  • Vibration has been severly increased at the branch pipe of main steam header since the commercial operation of a nuclear power plant. Intense broad band disturbance flow at the discontinuous region such as elbow, valve or heather generates the acoustical pulsation which is propagated through the piping system. The pulsation becomes the source of low frequency vibration at piping system. If it coincide with natural frequency of the pipe system, excessive vibration is made. High level vibration due to the pressure pulsation related to high dynamic stress, and ultimately, to failure probability affects fatally the reliability and confidence of plant piping system. This paper discusses vibration effect for the branch pipe system due to acoustical pulsations by broad band disturbance flow at the large main steam header in 7nn nuclear power plant. The exciting sources and response or the piping system are investigated by using on site measurements and analytical approaches. It is identified that excessive vibration is caused by acoustical pulsations of 1.3Hz, 4.4Hz and 6.6Hz transferred from main steam header, which are coincided with fundamental natural frequencies of the piping structure. The energy absorbing restraints with additional stiffness were installed to reduce excessive vibration.

  • PDF

An Experimental Study on Micro-vibration Measurement Methods of a Reaction Wheel (반작용휠의 미소진동 측정법에 관한 실험적 연구)

  • Kim, Dae-Kwan;Oh, Shi-Hwan;Lee, Seon-Ho;Yong, Ki-Lyuk
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.9
    • /
    • pp.828-833
    • /
    • 2011
  • A reaction wheel assembly(RWA) is the largest disturbance source that can induce high frequency micro-vibration on an optical payload of satellites. To ensure a tight pointing-stability budget of satellites, the RWA disturbance effect on spacecraft should be accurately analyzed and evaluated for whole design phases. For this purpose, the micro-vibration disturbance of RWA should be precisely measured. In the present study, two measurement methods on RWA micro-vibration disturbances are compared and investigated. One is a free run-down speed test and the other is a constant speed test. The micro-vibration data measured by the two methods are analyzed in terms of spectrum characteristics, static and dynamic imbalance values, and root sum square(RSS) values. The analysis results show that both methods can measure very similar results in time and frequency domains and that the free run-down speed method is more adequate in respects to wheel friction modeling, noise rejection of imbalance and RSS peak evaluation.

A Voltage Control Technique of Line-Interactive DVR Using 7-Level H-Bridge Inverter (7-레벨 H-Bridge 인버터를 이용한 Line-Interactive DVR의 전압제어)

  • Kang, Dae-Wook;Hyun, Dong-Seok;Lee, Woo-Cheol
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.4
    • /
    • pp.705-715
    • /
    • 2007
  • Recently, the interest on power quality has been hot issue because the equipments cause voltage disturbance and have become more sensitive to the voltage disturbance. Additionally, the reseach on power electronic equipments applying to the high power has been increased. This paper deals with Line-Interactive Dynamic Voltage Restorer(LIDVR) system using 7-Level H-Bridge inverter, which is one of the solutions to compensate the voltage disturbance and to increase the power of equipments. The LIDVR has the following advantages comparing to the DVR with the series injection transformer. It has the power factor near to unity under the condition of normal source voltage, can compensate the harmonic current of the load and the instant interruption, and has the fast response. First, the construction, the operation mode and algebraic modeling of LIDVR are reviewed. And then the voltage control algorithm is proposed to get the sinusoidal load voltage with constant amplitude. Finally, simulation and experiment results verify the proposed LIDVR system.

Dehydrogenase Activity and Physico-chemical Characteristics of Park Soils in Seoul (서울 공원 토양의 탈수소효소 활성과 물리화학적 특성)

  • Kim, Ok Kyung
    • The Korean Journal of Ecology
    • /
    • v.16 no.2
    • /
    • pp.191-198
    • /
    • 1993
  • The relationships between microbial activity and disturbance level of soil were investigated from 15 parks in Seoul and undisturbed area. The physico-chemical characteristics of soil and dehydrogenase activity(DHA) as an index of soil microbial activity were analysed. There were ranges of 3.84~7.37 in pH, 9.63~40.33% in moisture content, 3.41~21.49% in organic matter, 0.36~0.79g/g in water holding capacity and 0.03~0.53% in total nitrogen investigated sites. DHA values of soil were 8.64~$146.76{\mu}g/g$ in park soil and 545.14~$1, 198.80{\mu}g/g$ in undisurbed area. DHA of park soil with high traffic density and contamination source from human activities was much lower than that of undisturbed area. DHA was positively correlated with moisture content, organic matter, water holding capacity and total nitrogen.

  • PDF

An Experimental Study of the Swing Check Valve Disc Stability

  • Kim, Yang-Seok;Song, Seok-Yoon;Kim, Dae-Woong;Park, Sung-Keun;Hong, Sung-Yull
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 2004.10a
    • /
    • pp.157-158
    • /
    • 2004
  • To investigate the effects of the upstream flow conditions on the opening performance of the swing check valve, the tests were performed at various conditions of the disturbance type and distance from the tested check valves. The results show that the upstream flow disturbances due to elbow and globe valve at $2{\sim}10$ diameters upstream of the check valve produced minor effects on the check valve performance compared to the uniform flow condition. However, more detail analysis and additional testing with the other disturbance source, such as orifice with a large number of holes, are needed to refine and confirm the present results.

  • PDF