• 제목/요약/키워드: District heating

검색결과 437건 처리시간 0.027초

Energy News

  • 한국지역난방협회
    • 집단에너지
    • /
    • 통권1호
    • /
    • pp.58-61
    • /
    • 2005
  • PDF

국내 난방도일의 재정립에 관한 연구 (Study on the revision of Heating Degree-days for Korea)

  • 김성수;조성환;최창용;김상호;김연홍
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.17-22
    • /
    • 2007
  • Global average temperature rise accelerates by global warming in the three decades of the 20th century. But now we use heating degree days which was established 20 years ago. Therefore new heating degree days for 15 district areas of korea was determined using long-term measured data. Five different base temperatures ranging from 24 to $16^{\circ}C$ were chosen in the calculation of heating degree days. And yearly heating degree days were given in the tabular form.

  • PDF

한계상태 설계법을 이용한 지역난방 열배관의 국부좌굴 연구 (Study on Local Buckling of District Heating Pipes Using Limit State Design)

  • 김주용;이상연;고현일;조종두
    • 대한기계학회논문집A
    • /
    • 제34권12호
    • /
    • pp.1829-1836
    • /
    • 2010
  • 지역난방은 열병합 발전소에서 생산된 열을 온수의 형태로 열배관 네트워크를 통해 넓은 지역에 일괄적으로 공급하는 난방시스템이다. 일반적으로 지역난방 열배관은 지중에 매설되며 내부를 흐르는 온수의 압력과 온도변화, 매설 토사와의 마찰 및 반력에 의한 하중을 받게 되므로 열공급 효율과 함께 기계적인 안전성에 대한 검토가 반드시 필요하다. 본 논문에서는 강관의 한계상태 설계법을 이용하여 한계판폭두께비와 한계변형률, 두 가지 관점에서 열배관의 국부좌굴 발생여부를 평가하였으며 그 결과 현재 국내에서 사용되고 있는 모든 열배관은 국부좌굴이 발생하지 않음을 확인하였다. 마지막으로 국부좌굴을 피하기 위한 최소 예열온도를 산출함으로써 예열온도에 대한 시공 기준을 제시하였다.

태양열 축열조가 없는 변유량 제어 방식의 지역난방용 태양열시스템 실증시험연구 (The Development of the Climatic Design Tool for Energy Efficient Building Design)

  • 백남춘;신우철;이진국;윤응상;윤석만
    • 한국태양에너지학회 논문집
    • /
    • 제28권5호
    • /
    • pp.21-27
    • /
    • 2008
  • In this study, the design of the solar heating system for district heating as well as it's operating characteristics and the performance analysis was carried out. This solar district heating system was composed of two different types of solar collector circuit, flat plate and vacuum tube solar collector, in a system. This system supply constant temperature of hot water without solar buffer tank. For this, the proportional(variable flow rate) control was used. The experimental facility for this study was used the Bundang district solar heating system which was installed in the end of 2006. The operating characteristics and behaviour of each collector circuits are investigated especially for the system design and control. The yearly solar thermal efficiency is 47.5% on the basis of aperture area and 39.8% on the basis of gross area of collector. As a result this solar heating system without solar buffer tank and with proportional controller was testified a very effective and simplified system for district heating. It varied especially depend on the weather condition like as solar radiation and ambient temperature.

미활용 열에너지의 집단에너지 주민 수용성에 관한 연구 (A Study on Residents' Acceptance of Unutilized Heat in District Heating)

  • 원두환;오세신
    • 자원ㆍ환경경제연구
    • /
    • 제32권3호
    • /
    • pp.191-215
    • /
    • 2023
  • 본 연구는 미활용 열에너지를 집단에너지 열원으로 활용할 경우 주민 수용성을 비교 평가하는 것에 초점을 두고 있다. 열 부문 탄소중립에 있어 중요한 수단인 미활용 열에너지는 원활한 보급을 위해 주민 수용성의 확보가 중요하기 때문이다. 난방 소비자를 대상으로 한 설문조사를 통해 미활용 열에너지에 대한 인식조사를 수행하였으며, 컨조인트 모형을 이용해 소각열과 수열, 데이터센터 폐열을 기존의 가스 열원과 지불의사액을 평가해 비교하였다. 분석결과 제시된 미활용 열에너지의 보급 활성화가 중요하다고 인식하면서도 미활용 소각열에 비해서 수열과 데이터센터 폐열에 선호도가 높음을 확인하였다.

춘천시 주거지구내 수목피도의 차이가 난냉방에너지 이용 및 비용에 미치는 효과 (Effects of Difference in Tree Cover on Use and Cost of Heating and Cooling Energy in Residential Neighborhoods of Chuncheon)

  • 조현길;안태원
    • 한국조경학회지
    • /
    • 제27권2호
    • /
    • pp.19-28
    • /
    • 1999
  • This study quantified shading, evapotranspiration and windspeed-reduction effects of trees on use and cost of heating and cooling energy in two residential neighborhoods of Chuncheon different in tree cover. Annual savings per residence of heating energy were approximately 1,210 MJ(1%) and those of cooling energy, 130 kWh(10%) in study district 1 having tree cover of about 10% . For district 2 with tree cover of about 20%, annual heating and cooling savings were 2,130 MJ(2%) and 180 kWh(19%) per residence, respectively. Trees annually saved energy costs by approximately ₩31,000 ($26, $1=₩1,200) per residence in district 1 and by ₩49,000($41) in district 2. One tree taller than 3 m resulted in annual energy savings of ₩8,000($7) in the study districts. Energy savings by trees in district 2, which had higher tree cover by 10% difference than district 1, were about 2 times greater than those in district 1. This implies that more tree plantings could enhance energy saving effects. Of the total costs saved, 58% was attributed to windspeed reduction and 47%, evapotranspiration. However, shading increased energy costs by 5% due to tree plantings at the wrong locations. Full tree plantings on the west and north of buildings and avoidance of shade-tree plantings of use of solar-friendly trees on the south are recommended to increase building energy savings efficiently.

  • PDF

공동주택 지역난방 수질기준 설정에 관한 연구 (A Development of the Guideline for the Heating Water Quality in Apartment Houses with District Heating System)

  • 김용기;이태원;우달식;오준;안창구
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.493-498
    • /
    • 2008
  • Particles or deposit formed by corrosion of the pipe material bring about bad influences on the heating systems with inconvenience, energy loss and so on. In order to obtain the non-corrosive environments, the circulation hot water should properly be treated in several ways to satisfy one or more conditions of the followings: suitable pH-level, low hardness, low oxygen content, low conductivity, low level of chlorides and sulphur compounds and low level of solid particles. This experimental study was carried out to develope the new guidelines on the optimal water quality and directions for water quality management in heating systems. As results, it was recommended that the heating water be maintained pH-level not less than 8, hardness contents as $CaCO_3$ no more than 50 mg/L, turbidity no more than 10 NTU and T-Fe contents 1 mg/L below.

  • PDF

한국형 아파트의 난방에너지 분석 2: 난방방식에 따른 차이 (Analysis of Heating Energy in a Korean-Style Apartment Building 2: The Difference according to Heating Type)

  • 이봉진;정동열;이선;홍희기
    • 설비공학논문집
    • /
    • 제16권5호
    • /
    • pp.459-466
    • /
    • 2004
  • In order to save the energy in apartment houses, it is essential that the energy amount consumed in heating per household should be surveyed and analyzed according to heating method, which can be classified into unit, central and district methods. As a basis, we selected the household with nominal area of 32 py. because it accounts for the most percentage in Korea. It is estimated that the gas amount for cooking is 90 ㎥ and the energy amount for hot water supply is 11.41 GJ for a year, which is necessary to calculate the heating energy. Through the survey of actual energy consumption in Seoul and Gyeonggi, the energy amount used in heating can be obtained according to the heating type: 26.02 GJ/year for the unit heating, 28.09 GJ/year for the central heating and 40.61 GJ/year for the district heating.