• Title/Summary/Keyword: District 1

Search Result 2,108, Processing Time 0.035 seconds

Analysis of the Economic Efficiency of the District Heating and Gas Engine Co-Generation System Compared with the Central Heating System (중앙난방방식을 지역난방과 소형열병합난방 방식으로 전환 시 경제성 비교 분석)

  • Kim, Kyu Saeng
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.10
    • /
    • pp.544-551
    • /
    • 2015
  • This study was conducted to determine the LCC of apartment complexes with district heating and a cogeneration system. For the purpose of analyzing LCC according to the size of the apartment complex, 500, 1,500, and 4,000-unit model apartments were selected. Analysis was performed on the design of the heating system and the life cycle cost including total construction cost, maintenance and operation cost for the duration of the project period (15 years). According to the calculated results, 1) The initial cost of the cogeneration system for 500, 1,500, and 4,000-unit apartments is higher than that of the district heating system by 20%, 13%, and 12%, respectively. 2) In the case of the cogeneration system, the payback period by electric generation was found to be 5.21, 4.92 and 4.47 years, and saving cost was calculated to be 29 billion won, 94 billion won and 262 billion won after the payback period for 500, 1,500, and 4,000-unit apartments, respectively. 3) The LCC values of the cogeneration system were 1.12, 1.07 and 1.06 times larger than those of the district system according to the size of the apartment complex. In this study, the district heating system was found to be more efficient than the cogeneration system in terms of LCC reduction. 4) District heating is affected by fuel bills, so energy efficiency should be improved through recovering waste heat (incineration heat, etc.). Also, district cooling should be provided according to heat use to keep the temperature high in winter and low in summer.

Report on Trends of the Fatalities related to Drug-Toxicant and Drug Abuse in Central Area of Korea in 2002

  • Baeck, Seung-Kyung;Kim, Sun-Chun;Kim, Dong-Woo;Park, Yun-Sin;Seo, Joong-Seok
    • Proceedings of the PSK Conference
    • /
    • 2003.04a
    • /
    • pp.168.1-168.1
    • /
    • 2003
  • This report surveyed the trends of the fatalities related to the drug-toxicant (DT) and the drug abuse(DA), requested to analyze to the Central District Office of National Institute of Scientific Investigation for a year, 2002. The mortality related to DT in men was more common than that in the women. The most common age group of DT intoxication was 30's. (omitted)

  • PDF

Analysis for the Economic efficiency of District Heating and Gas Engine Co-generation System comparing with Central Heating System (중앙난방방식을 지역난방.소형열병합난방방식으로 전환시의 경제성 비교 분석)

  • Kim, Kyu-Saeng;Lee, Sang-Hyeok;Hong, Kyung-Pyo;Won, Young-Jae
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.459-465
    • /
    • 2007
  • This study was conducted to calculate the LCC of a apartment complex with a type of heating system, district heating and cogeneration system. For the purpose of analyzing LCC according to size of apartment complex, 500, 1,500 and 4,000 houses of model apartment selected. This research performs design of heating system and the life cycle cost analysis including an initial cost, energy cost, maintenance and operation cost, replacement cost and renovation cost during the project period(15years). According to the calculated results, 1) Initial cost of cogeneration system with 500, 1500 and 4000 houses is higher than district heating system each of 20%, 13%, 12%. 2) In case of cogeneration system, the payback period by electric generation is 5.21, 4.92 and 4.47 years and saving cost was calculated 29 billion won, 94 billion won and 262 billion won after payback period. 3) Cogeneration system LCC was 1.12, 1.07 and 1.06 times larger than district system with the size of apartment complex. According to the case of this study district heating system is more efficient than cogeneration system in terms of the reduction of LCC. 4) Gas Engine Co-generation System is more efficient than other systems because it can collect progressive part from electric charge progressive stage system. However, the efficiency is decreasing because of raising of fuel bills(LNG) and lowering of power rate for house use. Especially the engine is foreign-made so the cost of maintenance and repair is high and the technical expert is short. 5) District heating is also affected by fuel bills so we should improve energy efficiency through recovering of waste heat(incineration heat, etc.). Also, we should supply district cooling on the pattern of heat using of let the temperature high in winter and low in summer.

  • PDF

Proper Arrangement of City Park though Analysis of Disposition Distance (유치거리 분석을 통한 도시공원의 적정배치에 관한 연구)

  • Ryu, Yeun-Soo;Ra, Jung-Hwa;Do, Hu-Jo
    • Current Research on Agriculture and Life Sciences
    • /
    • v.20
    • /
    • pp.33-38
    • /
    • 2002
  • The purpose of this study is to analysis of disposition distance of city park for the plan of suitable arrangement of city park based on the date examining Daegu Metropolitan City. The results of this study are as follows. 1) The result of analysis of population density as the case of districts, it appeared highly in city center area which Seo-Gu district and Nam-Gu district besides Jung-Gu district. However, it apperared in a low Buk-Gu district, Dong-Gu district and Salseong-Gun. 2) The result of analysis of population density as the case of regions, it appeared very highly Joukjun-Dong of Dalseo-Gu district($31,554per/km^2$), Naedang-Dong of Seo-Gu district($29,922per/km^2$). However it appeared in a low Yeuga-Maen($85per/km^2$) and Gachang-Maen($94per/km^2$) of Dalseong-Gun. The regions where the population density is high have very low green space and live a lot of low income layer. 3) The result of analysis of disposition distance, in the case of children park, it appeared an intensive distribution in Dongcheon-Dong and Guam-Dong of Buk-Gu district, Whanggm-Dong and Dusan-Dong of Suseong-Gu district, Sangin-Dong and Yeongsan-Dong and Walsung-Dong of Dalseo-Gu district. however, it appeared in a low in Jung-Gu district. The case of urban park of the neighboring area, it appeared the most in Dalseo-Gu district except 2 parks in Jung-Gu district, the case of urban park of the walking area, it appeared in equality in city. 4) In conclusion, the area have high population density and lots of low income layer, is in out of disposition distance should be considered in first for city park plan.

  • PDF

The Ivestigation and Estimate of Influence on Air Quality by the Exhaust of Air Pollutant from Facility of the District Heating Located in Small City (중소도시에 위치한 집단 열 공급시설에서 배출되는 대기오염물에 의한 주변 대기질의 영향 조사 및 예측)

  • Yeon, Ik-Jun;Kim, Kwang-Yul
    • Journal of environmental and Sanitary engineering
    • /
    • v.18 no.3 s.49
    • /
    • pp.1-10
    • /
    • 2003
  • This study was aimed to investigate the influence on the vicinity by air pollutant generated from facility of the district heating located in local small town. We selected the seven areas arround the surroundings of facility of the district heating, compared the air quality evaluated before and after operations of the facility, and estimated the diffusion of air pollutant exhausted from the facility using a ISC model. The result was that the concentration of TSP before and after operations of the facility was 89${\sim}$94${\mu}$g/m$^3$,and 72${\sim}$81${\mu}$g/m$^3$, respectively and the latter showed a decline in concentration. Also, there was no relationship between straight distance from the facility of the district heating and the concentration of TSP. This result was applicable to cases of PM-10 and SO$_2$. We also investigated the influence on the air around the neighbored area by air pollutant produced from facility of the district heating using ISCLT3 model. The adding-concentrations of TSP, SO$_2$,NO$_2$, and CO were 0.0019${\sim}$0.00183${\mu}$g/m$^3$, 0.0029${\sim}$0.5648ppb, 0.2924${\sim}$l.9837ppb,and 0.0087${\sim}$0.0590ppb, respectively. It is predicted that each concentration is added to pollutant exhausted from facility of the district heating and is about 1/100${\sim}$1/180,000 of present air quality. This has a tiny influence on general air quality. According to this analysis, the concentration of air pollutant is less effected to pollutants expected by the facility of the district heating than other pollutants emitted from mobil source or industrial complex, and etc.

Simulation of Indoor Shooting Range Fire in Busan by Using FDS (FDS를 이용한 부산 실내사격장 화재 시뮬레이션)

  • Cho, Young-Jin;Seo, Young-Il;Moon, Byung-Sun;Kim, Sung-Jin;Jeon, Woo-Jeong
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.143-146
    • /
    • 2011
  • 2009년 11월 14일 발생한 부산 실내사격장 화재와 관련하여 조사내용을 토대로 화재 시뮬레이션용 전선유체역학 모델인 FDS를 이용하여 재현하였으며, 시뮬레이션 결과와 화재당시 녹화된 CCTV 영상을 비교하였다. 2층 발사실에서 시작된 화재는 급격히 연소가 진행되어 약 3초 후에 휴게실로 확산되며, 약 7초 후에는 계단 및 1층 홀을 지나 사람들이 통행하는 인도에까지 연기가 분출되는 것으로 나타났다. 시뮬레이션 결과는 2층 발사실과 휴게실에 녹화된 CCTV 영상 및 1층 홀 옆의 귀금속가게에 녹화된 CCTV 영상과 거의 일치하였다.

  • PDF

A Study on the Design and Analysis of District Solar Heating and Cooling System with Preheating of Returning District Heating Water (지역난방수 환수 승온방식의 태양열 지역냉난방 시스템 분석)

  • Baek Nam-Choon;Shin U-Cheul;Lee Jin-Kook;Yoon Eung-Sang;Yoon Suk-Man
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.433-437
    • /
    • 2005
  • This study was carried out the design and analysis of solar thermal system with preheating of returning district heating water for the Chung-ju district heating and cooling system. Two different types of solar collectors are used for this system. TRNSYS simulation program was used for the analysis. As a results, the solar system efficiency is $35.8\%$ for the plate type and $45.1\%$ for the evacuated type solar collector in the case of $50^{\circ}C$ for the returning district heating water temperature. The returning district heating water temperature is on of the very important factors that is influence on the system efficiency. So the effect of the returning district heating water temperature on the system efficiency is analyzed in this study.

  • PDF

Ditching the Party: Disaggregating Split Ticket Voting in Taiwan's 2016 Legislative Election

  • Rich, Timothy S.
    • Analyses & Alternatives
    • /
    • v.3 no.1
    • /
    • pp.63-92
    • /
    • 2019
  • What motivates split-ticket voting in mixed electoral systems, where voters choose one party in district races and another party on the party list ballot? While much of the literature assumes strategic intent, three aspects commonly are overlooked: the competitiveness of district races, the presence of a district candidate from one's preferred party, and whether voters know the electoral threshold for party list seats. Furthermore, few studies disaggregate types of split-ticket voting (e.g. not voting for one's preferred party in a district vs. party list). Taiwan provides an intriguing case study for analysis, not only as a relatively new adopter of a mixed system, but also the presence of additional conditions that would encourage at least the consideration of a split ticket. Using survey data from the Taiwan's Election and Democratization Studies (TEDS) after the Taiwan's 2016 Legislative Yuan election, this analysis finds that knowing the threshold, the winner's margin, and the placement of a district candidate from one's preferred party all influence split-ticket voting among those with a partisan preference. However, closer inspection identifies a distinction between defecting from the district versus the party list. Evidence shows that district competitiveness and candidate placement influences defection from the district candidate, while the electoral threshold influences defection from the party list. The results add to our understanding of strategic and non-strategic incentives in mixed systems.

  • PDF

An Experimental Study on the Chemical Values of the Tap Water in Seoul (서울시 수도수의 이화학적 수질조사)

  • 홍태용
    • Journal of Environmental Health Sciences
    • /
    • v.7 no.1
    • /
    • pp.21-31
    • /
    • 1981
  • This survey was carried out to investigate the temperature, pH value, nitrogen (ammonia, nitrite, nitrate), turbidity, color, chloride ion, $KMnO_4$ consumed, and hardness as chemical analysis of the tap water in Seoul city area during the period from September to Octobor, 1979, and to observe the differences among the values by the distance from the water purification plant and by the district supplied tap water from-the each water purification plant. The results obtained were as follows: 1) An average of the water temperature was $19.8\pm 0.2\circ$C. 2) An average of pH was $7.18\pm 0.02$. The difference among each district was statistically significant (p<0.01), but it was not observed among each distance. 3) An average of turbidity was $1.25\pm 0.12$ ppm. The difference among each district was highly significant (p<0.01), respectively, but not among each distance. 4) An average of color was $1.43\pm 0.16$ ppm, and there were statistically significant differences by the distance and by the district (p<0.01). 5) An average of ammonia nitrogen was $0.022\pm 0.005$ ppm. The differences among each distance, and district were statistically significant (P<0.01). 6) An average of nitrite nitrogen was $0.0050\pm 0.0013$ ppm, and the difference among each distance was highly significant (p<0.01), respectively, and each district showed statistical significance (p<0.01). 7) An average of nitrate nitrogen was $0.82\pm 0.08$ ppm. The difference among each district was significant (p<0.05), and each distance showed high significance (p<0.01). 8) An average of $KMnO_4$ consumed was $3.73\pm 0.16$ ppm, and the difference among each district was significant (p<0.05), but it was not observed among each distance. 9) An average of chloride ion was $8.56\pm 0.28$ ppm, and the difference among each district was higly significant (p<0.01), respectively, but it was not observed among each distance. 10) An average of hardness was $40.69\pm 1.17$ ppm, and there was statistically significant difference by each district (P<0.01), but not by distance. 11) The interrelation between temperature and pH of the tap water revealed the negative correlation from the coefficient of it as showed r=-0.6073 and p<0.01. 12) Except water temperature, there were negative correlationships between pH and other water qualities. 13) Correlation coefficients of $KMnO_4$ comsumed and ammonia nitrogen, nitrite nitrogen were statistically significant but that of $KMnO_4$ consumed and nitrate nitrogen showed no statistical correlationship. 14) Ammonia nitrogen seems to have high correlationship with nitrite nitrogen(r= +0.6669), but not with nitrate nitrogen. 15) Nitrate nitrogen seems to have statistically significant correlationship with nitrite nitrogen (r=+0.4959), but not with ammonia nitrogen. 16) The interrelation between chloride ion and hardness of the tap water revealed positive correlation from the coefficient of it as showed as r=+0.4888 and p<0.01.

  • PDF