Thermally Stratified Hot Water Storage (태양열의 성층축열과 주택이용에 관한 연구(성층축열))

  • Pak, Ee-Tong
    • Solar Energy
    • /
    • v.10 no.3
    • /
    • pp.3-12
    • /
    • 1990
  • This paper deals with experimental research to increase thermal storage efficiency of hot water stored in an actual storage tank for solar application. The effect of increased energy input rate due to stratification has been discussed and illustrated through experimental data, which was taken by changing dynamic and geometric parameters. Ranges of the parameters were defined for flow rate, the ratio of diameter to height of the tank and inlet-exit water temperature difference. During the heat storage, when the flow was lower, the temperature difference was larger and the ratio of diameter to height of the tank was higher, the momentum exchange decreased. As for this experiment, when the flow rate was 8 liter/min, the temperature difference was $30^{\circ}C$ and the ratio of diameter to height of the tank was 3, the momentum exchange was minimized resulting in a good thermocline and a stable stratification. In the case of using inlet ports, if the modified Richardson number was less than 0.004, full mixing occured and so unstable stratification occured, which mean that this could not be recommended as storage through thermal stratification. Using a distributor was better than using inlet ports to form a sharp thermocline and to enhance the stratification. It was possible to get storage efficiency of 95% by using the distributor, which was higher than a storage efficiency of 85% obtained by using inlet ports in same operation condition. Furthermore, if the distributor was manufactured so that the mainpipe decreases in diameter toward the dead end to maintain constant static pressure, it might be predicted that further stable stratification and higher storage efficiency are obtainable(ie:more than 95%).

  • PDF

A Study on Feed Rate Characteristics of Motor-driven Cylinder Lubricator by the Electronically Controlled Quill System Equipped with an Accumulating Distributor in a Large Two-stroke Diesel Engine (대형 2행정 디젤기관에 있어서 축압분배기 부착 전자제어식 퀼 시스템 모터구동 실린더 주유기의 송출유량 특성에 관한 연구)

  • Bae, Myung-Whan;Jung, Hwa;Bae, Chang-Hwan
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.19 no.4
    • /
    • pp.91-98
    • /
    • 2011
  • Minimizing the cylinder wear and the consumption rate of cylinder oil in a large two-stroke diesel engine is of great economic importance. A motor-driven cylinder lubricator for Sulzer RT-flex large two-stroke diesel engines developed by authors is in need of mounting a quill system to lubricate cylinder parts for smoother operation. In order to apply the common-rail lubricating system to the developed cylinder lubricator as the second research stage, the quill system with a progressively quantitative distributor is improved in the electronically controlled quill system with an accumulating distributor. In this study, the effects of lubricator motor speed, plunger stroke and cylinder back pressure on oil feed rate, maximum discharge and delivery pressures are experimentally investigated by using the electronically controlled quill system with an accumulating distributor in the developed cylinder lubricator. It is found that the oil feed rate of the electronically controlled quill system with an accumulating distributor is larger than that of the quill system with a progressively quantitative distributor because of the increase of delivery speed and volume by changing the location of accumulator in the same experimental condition.

Experimental Study on the Effective Use of Thermally Stratified Hot Water Storage System (열성층 온수저장시스템의 효율적 이용에 관한 실험적 연구)

  • Pak, Ee-Tong
    • Solar Energy
    • /
    • v.13 no.2_3
    • /
    • pp.45-52
    • /
    • 1993
  • The benefits of thermal stratification in sensible heat storage were investigated for residential solar applications. The effect of increased thermal useful efficiency of hot water stored in an actual storage tank due to stratification has been discussed and illustrated through experimental data and computer simulation, which were taken by changing dynamic and geometric parameters. When the flow rate was 8 liter/min and ${\Delta}T=40^{\circ}C$ was $40^{\circ}C$, the useful efficiency(${\eta}_u$) was about 90% in case of using a distributor, but not using a distributor the useful efficiency(${\eta}_u$) was about 82%. So these kinds of distributor would be recommendable for a hot water storage system and residential solar energy application to increase useful efficiency(${\eta}_u$). In the case of the uniform circular distributor, when the flow rate was 8 liter/min partial mixing was decreased and a stable stratification was obtained. Furthermore, if the distrbutor was manufactured so that the flow is to be the same from all perforations in order to enhance stratification, it might be predicted that further stable stratification and higher useful efficiency(${\eta}_u$) are obtainable.

  • PDF

Stress and Fatigue Evaluation of Distributor for Heat Recovery Steam Generator in Combined Cycle Power Plant (복합발전플랜트 배열회수보일러 분배기의 응력 및 피로 평가)

  • Lee, Boo-Youn
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.8
    • /
    • pp.44-54
    • /
    • 2018
  • Stress and fatigue of the distributor, an equipment of the high-pressure evaporator for the HRSG, were evaluated according to ASME Boiler & Pressure Vessel Code Section VIII Division 2. First, from the results of the piping system analysis model, reaction forces of the tubes connected to the distributor were derived and used as the nozzle load applied to the detailed analysis model of the distributor afterward. Next, the detailed model to analyze the distributor was constructed, the distributor being statically analyzed for the design condition with the steam pressure and the nozzle load. As a result, the maximum stress occurred at the bore of the horizontal nozzle, and the primary membrane stress at the shell and nozzle was found to be less than the allowable. Next, for the transient operating conditions given for the distributor, thermal analysis was performed and the structural analysis was carried out with the steam pressure, nozzle load, and thermal load. Under the transient conditions, the maximum stress occurred at the vertical downcomer nozzle, and of which fatigue life was evaluated. As a result, the cumulative usage factor was less than the allowable and hence the distributor was found to be safe from fatigue failure.

A Numerical Study on Refrigerant Distribution according to the Insertion Depth of the Distributor-Outlet Pipes in an Air-Conditioning System (공조 시스템 내의 분배기 출구관의 삽입깊이에 따른 유량분포연구)

  • Lee, Hee Won;Park, Il Seouk
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.9
    • /
    • pp.491-496
    • /
    • 2015
  • Generally, the phase of the refrigerants that circulate in air-conditioning systems is repeatedly changed from liquid to gas and from gas to liquid. In vapor-compression refrigeration, the refrigerant at the inlet of the evaporator is in a gas-liquid two-phase state; therefore, to enhance the heat-transfer performance of the evaporator, the even distribution of the refrigerant across multiple passages of the evaporator is essential. Unlike the distribution of a single-phase refrigerant, multi-phase distribution requires further considerations. It is known that the multi-phase distribution at the outlet of the distributor is affected by factors such as the operating condition, the distributor's shape, and the insertion depth of the outlet pipes; here, the insertion depth of the outlet pipes is especially significant. In this study, for a cylindrical distributor with a 90-degree bend entrance and three outlet pipes, the flow uniformity at the outlet pipes was numerically tested in relation to variations of the insertion depth of the outlet pipes.

Numerical and Experimental Studies for the Design of High Efficiency Sedimentation Bed (고효율 침전조 설계를 위한 실험 및 수치해석)

  • Kim, Hong-Min;Choi, Sang-Cheol;Kim, Kwang-Yong;Kim, Byung-Hee;Lim, Young-Taek
    • 유체기계공업학회:학술대회논문집
    • /
    • 2002.12a
    • /
    • pp.425-432
    • /
    • 2002
  • Both numerical and experimental studies on sedimentation efficiency of a sedimentation bed were carried out. Three different structures of sedimentation bed and five different combinations of blockage ratio of center feed wall and angle of distributor are implemented to find the optimal values of geometric parameters. The effect of rotation of the distributor on sedimentation efficiency is also investigated. It reveals that the effect of blockage ratio and angle of distributor on sedimentation efficiency is considerable, while rotation effect can be neglected, and that calculated efficiencies show good agreements with those of experiment, qualitatively.

  • PDF

Numerical and Experimental Studies for the Design of High Efficiency Sedimentation Bed (고효율 침전조 설계를 위한 실험 및 수치해석)

  • Kim, Hong-Min;Choi, Sang-Cheol;Kim, Kwang-Yong;Kim, Byung-Hee;Lim, Young-Taek
    • The KSFM Journal of Fluid Machinery
    • /
    • v.6 no.2 s.19
    • /
    • pp.54-61
    • /
    • 2003
  • Both numerical and experimental studies on the sedimentation efficiency of a sedimentation bed were carried out. Three different structures of sedimentation bed and five different combinations of blockage ratio of center feed wall and angle of distributor are implemented to find the optimal values of geometric parameters. The effect of rotation of the distributor on sedimentation efficiency is also investigated. It reveals that the effects of blockage ratio and angle of distributor on sedimentation efficiency are considerable, while rotation effect can be neglected, and that calculated efficiencies show good agreements with those of experiment, qualitatively.

A Method for Improving Air Distribution Performance at the Residence Ventilation System (주거 환기 시스템의 공기 분배 성능 개선 방안)

  • Park, Eun-Jun;Kim, Yong-Bong;Na, Hee-Hyoung;Lee, Sang-Ki
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.589-593
    • /
    • 2007
  • In the mechanical ventilation system, it is a fundamental condition to distribute the air equally to the each room. In this study, distribution performance of the air distributor which generally connected to a circular duct was investigated by simulation and experiment. In the first CFD analysis, maximum air flow rate deviation was an 63% in the air distributor model. After numbers of model modification and simulation, maximum flow rate deviation was reduced to 19% in the final simulation model. An air distributor which used in the experiment was produced by using data obtained from the final analysis. When experimental result was compared with analysis result, there was a deviation difference as much as 9%.

  • PDF

Effects on Refrigerant Maldistribution on the Performance of Evaporator (냉매의 불균일한 분배가 증발기의 성능에 미치는 영향)

  • 김창덕;이진호
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.3
    • /
    • pp.230-240
    • /
    • 2004
  • An experimental investigation was conducted to study two-phase flow distribution in a T-type distributor of slit fin-and-tube heat exchanger using R22. A comparison was made between the predictions by previously proposed tube-by-tube method and experimental data for the heat transfer rate of evaporator. Experiments were carried out under the conditions of saturation temperature of 5$^{\circ}C$ and mass flow rate varying from 0.6 to 1.2kg/min. The inlet air has dry bulb temperature of 27$^{\circ}C$, relative humidity of 50% and air velocity varying from 0.63 to 1.71㎧. Experiment show that air velocity increased by 85.2% is need for T-type distributor with four outlet branches than that of two outlet branches under the superheat of 5$^{\circ}C$, which resulted in air-side pressure drop increase of 130% for T-type distributor with four outlet branches as compared to two outlet branches.