• Title/Summary/Keyword: Distribution power lines

Search Result 306, Processing Time 0.023 seconds

Development of a Ubiquitous Sensor for Monitoring Insulators and Lightning Arresters (애자/피뢰기 모니터링을 위한 유비쿼터스 센서 개발)

  • Kil, Gyung-Suk;Rhyu, Keel-Soo;Song, Jae-Yong;Kim, Il-Kwon;Park, Dae-Won;Choi, Soo-Yeon
    • Journal of the Korean Society for Railway
    • /
    • v.10 no.2 s.39
    • /
    • pp.117-123
    • /
    • 2007
  • In this study, a ubiquitous sensor for condition monitoring of insulators and lightning arresters installed in power distribution lines and electric traction vehicles is presented. The sensor consists of two parts; a leakage current measurement and a lightning surge detection. Measured data are transmitted to a supervisory computer through ZigBee protocol based on IEEE 802.15.4. To detect leakage current, a window type Mn-ZCT is used and a low-noise amplifier with a gain of 60dB is designed, and this can measure leakage current in ranges of $100{\mu}A{\sim}5mA$. A sample-hold (S/H) and a Rogowski coil are injected to analyze the magnitude of surge current in ranges from 100A to 10kA with $8/20{\mu}s$-waveform.

Quench characteristics of YBCO thin films using magnetic field source for superconducting fault current limiters

  • Lee, B.W.;Park, K.B.;Kang, J.S.;Oh, I.S.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.6 no.2
    • /
    • pp.11-14
    • /
    • 2004
  • YBCO thin films have good characteristics for current limiting materials due to compact size and high current carrying capability. But the irregularities and the extreme thin thickness of YBCO films cause some difficulties in simultaneous quench and thermal shock protection. In order to solve these problems, vertical magnetic field generated from solenoid coil was applied to the YBCO element. And also to minimize the inductance caused by the serial connection of magnetic field source with superconducting elements, magnetic field source was separated from the power lines adapting protective current transformer. In this study, electric field-current (E-I) and quench characteristics of YBCO films were analyzed both by electrical measuring method and observations of bubble propagation. From the experiment results, it was revealed that the magnetic fields generated by surrounding coil could induce the uniform quench distribution for all stripes of current limiting units and finally simultaneous quenches were realized in all serial connection of YBCO elements. In addition, the separation of magnetic field source form electrical network could be good solution for simultaneous quench of YBCO films without any unnecessary effect caused by serial connection.

Study on Surge Absorption Capability for Power Arrester with MOV Micro-milling Characteristics (전력용 피뢰기의 MOV 미립화와 에너지 내량 특성 연구)

  • Han, Se-Won;Cho, Han-Goo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.05b
    • /
    • pp.120-124
    • /
    • 2004
  • The protection performance and energy absorption capability are important for both MOAs for distribution lines and MOAs for high voltage systems, therefore the manufacturing technique of ZnO varistor elements with high ability against surge impacts is great important for high voltage systems. But until now ZnO varistors for low voltage class have been developed in Korea, ZnO varistors with the rate discharge current of 5, 10kA class for high voltage systems depend on an import from advanced countries, such as Japan or U.S.A, which have developed its in the late 1980s. So in the aspect of taking independent technique the development of ZnO varistors with the rate discharge current of 5, 10kA class for high voltage systems is important. In this research project ZnO varistor elements with diameters of 35mm and 70mm for the rate discharge current of 5, 10kA class for high voltage systems are manufactured, then various chemical composition and processing variables affected the electrical and the physical characteristics of these ZnO varistors are investigated.

  • PDF

A Study of Life Prediction Assessment of T/L 36,000 Ibs Porcelain Insulators (송전용 36,000 lbs 자기애자의 수명 예측 연구)

  • Choi, In-Hyuk;Choi, Yon-Gyu;Lee, Dong-Il;Lee, Won-Kyo;Kang, Byoung-Kyu;Park, Jun-Ho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.7
    • /
    • pp.636-644
    • /
    • 2007
  • 36,000lbs porcelain insulators of D-1995, D-1997 and D-2002 investigated mechanical and electrical qualities, where is process of using in the Korea 154 kV transmission lines. It analyzes the cause of the elapse of a year aging of the transmission insulators. Weibull distribution function, product quality and uniform quality, etc. investigated for prediction to extant life of insulator. It calculate change as statistical elapse of a year through product qualities of used insulator and new insulator, uniform equality and uniformity of insulator. In case of D-1995 year used insulator, it decided to badness decline index k by 0.0237, badness quality index by 1.0 and 3.0. Result of extant confidence life Ym was calculated that remain each 4 yens and 0.7 yens that uniformity index is considered. Extant life of D-1997 and D-2002 insulators Predicted by about 40 years.

COMMISSIONING RESULT OF THE KSTAR HELIUM REFRIGERATION SYSTEM

  • Park, Dong-Seong;Chang, Hyun-Sik;Joo, Jae-Joon;Moon, Kyung-Mo;Cho, Kwang-Woon;Kim, Yang-Soo;Bak, Joo-Shik;Cho, Myeon-Chul;Kwon, Il-Keun;Andrieu, Frederic;Beauvisage, Jerome;Desambrois, Stephane;Fauve, Eric
    • Nuclear Engineering and Technology
    • /
    • v.40 no.6
    • /
    • pp.467-476
    • /
    • 2008
  • To keep the superconducting (SC) magnet coils of KSTAR at proper operating conditions, not only the coils but also other cold components, such as thermal shields (TS), magnet structures, SC bus-lines (BL), and current leads (CL) must be maintained at their respective cryogenic temperatures. A helium refrigeration system (RRS) with an exergetic equivalent cooling power of 9 kW at 4.5 K without liquid nitrogen ($LN_2$) pre-cooling has been manufactured and installed. The main components of the KST AR helium refrigeration system (HRS) can be classified into the warm compression system (WCS) and the cryogenic devices according to the operating temperature levels. The process helium is compressed from 1 bar to 22 bar passing through the WCS and is supplied to cryogenic devices. The main components of cryogenic devices are consist of cold box (C/B) and distribution box (D/B). The C/B cool-down and make the various cryogenic helium for the KSTAR Tokamak and the various cryogenic helium is distributed by the D/B as per the KSTAR requirement. In this proceeding, we will present the commissioning results of the KSTAR HRS. Circuits which can simulate the thermal loads and pressure drops corresponding to the cooling channels of each cold component of KSTAR have been integrated into the helium distribution system of the HRS. Using those circuits, the performance and the capability of the HRS, to fulfill the mission of establishing the appropriate operating condition for the KSTAR SC magnet coils, have been successfully demonstrated.

Development of 6.6kV Resistive Superconducting Fault Current Limiters (6.6kV급 초전도 저항형 한류기 개발에 관한 연구)

  • Lee, B.W.;Park, K.B.;Kang, J.S.;Kim, H.M.;Oh, I.S.;Hyun, O.B.
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1745-1747
    • /
    • 2004
  • In order to anticipate gradual increase of fault current in electric power systems, current limiting technology and current limiting device has been investigated for a long time. But the commercial use of current limiting device was delayed due to the lack of effective method to insert impedance to the elective power systems without loss and surplus defects. However, novel current limiting device, which use superconducting materials, was considered as a dream technology to be applied in a distribution and transmission lines. LG Industrial systems and KERPI started to investigate resistive type superconducting fault current limiters in order to develop 154kV fault current limiters and this year, we succeed to test 3 phase 6.6kV/200A fault current limiters. Based on these achievements, 24kV superconducting fault current limiters will be realized withing 3 years which could be tested in a real fields. In this paper, the developments of fault current limiting module which use YBCO thin films, cryogenic systems, the structure and construction of 3 phase fault current limiters and finally the test results of 6.6kV superconducting fault current limiters will be introduced.

  • PDF

Optimal Threshold from ROC and CAP Curves (ROC와 CAP 곡선에서의 최적 분류점)

  • Hong, Chong-Sun;Choi, Jin-Soo
    • The Korean Journal of Applied Statistics
    • /
    • v.22 no.5
    • /
    • pp.911-921
    • /
    • 2009
  • Receiver Operating Characteristic(ROC) and Cumulative Accuracy Profile(CAP) curves are two methods used to assess the discriminatory power of different credit-rating approaches. The points of optimal classification accuracy on an ROC curve and of maximal profit on a CAP curve can be found by using iso-performance tangent lines, which are based on the standard notion of accuracy. In this paper, we offer an alternative accuracy measure called the true rate. Using this rate, one can obtain alternative optimal threshold points on both ROC and CAP curves. For most real populations of borrowers, the number of the defaults is much less than that of the non-defaults, and in such cases the true rate may be more efficient than the accuracy rate in terms of cost functions. Moreover, it is shown that both alternative scores of optimal classification accuracy and maximal profit are the identical, and this single score coincides with the score corresponding to Kolmogorov-Smirnov statistic used to test the homogeneous distribution functions of the defaults and non-defaults.

A New Measurement Method of the Ground Resistance Using a Low-pass Filter in Energized Substations (지역필터를 이용한 수변전실 접지저항의 새로운 측정방법)

  • Lee, Bok-Hui;Eom, Ju-Hong;Lee, Seung-Chil;Kim, Seong-Won;An, Chang-Hwan
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.8
    • /
    • pp.387-393
    • /
    • 2001
  • This paper describes an advanced measuring method and precise evaluation of the ground resistance for the grounding system of energized substations and power equipments. A grounding system of substations consists of all interconnected grounding connections of grounded conductors, neutral ground wires, underground conductors of distribution lines, cable shields, grounding terminals of equipments, and etc. It is very difficult to measure the accurate ground resistance of the grounding terminals of equipments, and etc. It is very difficult to measure the accurate ground resistance of the grounding system of high voltage energized substations because of harmonic components caused by switched power supplies or overloads. The conventional fall-of-potential method may be subject to big error if stray ground currents and potentials are present. In this work, to improve the precision in measurements of the ground resistance by eliminating the effects of harmonic components and stray currents and potentials, the investigations of the ground resistance measurement by using a low pass filter in a model energized grounding system were conducted. The accuracy of ground resistance mesurements was evaluated as a function of the ratio of the test signal to noise (S/N). The errors due to the proposed ground resistance measurement method were decreased with increasing S/N and were less than 5[%] as S/N is 10. The proposed ground resistance measurement method appears to be considerably more accurate than the conventional fall-of -potential method. It is allows cancellation of the parasitic resistance of energized grounding systems, to employ the measurement method that allows cancellation of the parasitic effects due to other circulating ground currents and ground potential rises in practical situations.

  • PDF

A study on the discriminant analysis of node deployment based on cable type Wi-Fi in indoor (케이블형 Wi-Fi 기반 실내 공간의 노드 배치 판별 분석에 관한 연구)

  • Zin, Hyeon-Cheol;Kim, Won-Yeol;Kim, Jong-Chan;Kim, Yoon-Sik;Seo, Dong-Hoan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.9
    • /
    • pp.836-841
    • /
    • 2016
  • An indoor positioning system using Wi-Fi is essential to produce a radio map that combines the indoor space of two or more dimensions, the information of node positions, and etc. in processing for constructing the radio map, the measurement of the received signal strength indicator(RSSI) and the confirmation of node placement information counsume substantial time. Especially, when the installed wireless environment is changed or a new space is created, easy installation of the node and fast indoor radio mapping are needed to provide indoor location-based services. In this paper, to reduce the time consumption, we propose an algorithm to distinguish the straight and curve lines of a corridor section by RSSI visualization and Sobel filter-based edge detection that enable accurate node deployment and space analysis using cable-type Wi-Fi node installed at a 3 m interval. Because the cable type Wi-Fi is connected by a same power line, it has an advantage that the installation order of nodes at regular intervals could be confirmed accurately. To be able to analyze specific sections in space based on this advantage, the distribution of the signal was confirmed and analyzed by Sobel filter based edge detection and total RSSI distribution(TRD) computation through a visualization process based on the measured RSSI. As a result to compare the raw data with the performance of the proposed algorithm, the signal intensity of proposed algorithm is improved by 13.73 % in the curve section. Besides, the characteristics of the straight and the curve line were enhanced as the signal intensity of the straight line decreased by an average of 34.16 %.

Performance Analysis of the Powerline Communication for Condition Monitoring System of an MW Class Offshore Wind Turbine's Nacelle (MW급 해상풍력발전기 나셀의 상태 감시를 위한 전력선 통신 성능 분석)

  • Sohn, Kyung-Rak;Kim, Kyoung-Hwa;Jeong, Seong-Uk;Nam, Seung-Yun;Kim, Hyun-Sik
    • Journal of Navigation and Port Research
    • /
    • v.40 no.3
    • /
    • pp.159-164
    • /
    • 2016
  • The goal of this study is to implement a communication system that can monitor the status of the nacelle using the power cable itself, without the dedicated communication lines such as an UTP cable and optical fiber for the offshore wind turbine. An inductive coupling powerline communication system for a MW class offshore wind turbine was proposed and its communication performance was demonstrated. The inductive couplers was designed for operation at up to 500 A using a ferrite composite materials. Field test was carried out on the wind farms of Jeju island. Using the iperf communication test program, we have obtained more than 15 Mbps data transmission rate through the 100 m power cable that was installed between the nacelle and the bottom of the power converter. In the data transmission stability test for a week, there was no failure ever. The minimum transmission rate was 15 Mbps and the average data rate was about 20 Mbps. Next, we have installed an infrared camera inside the nacelle in order to measure the temperature distribution and variation of the nacelle. The real-time thermal image taken by the camera was successfully sent to the monitoring system without error.