• Title/Summary/Keyword: Distribution of Water Quality

Search Result 901, Processing Time 0.028 seconds

Estimation on Chemical Water Quality Suitability Index for 4 Species of the Mayfly Genus Ephemera (Ephemeroptera: Ephemeridae) Using Probability Distribution Models (확률분포모형을 이용한 하루살이속(Ephemera) 4종에 대한 화학적 수질 적합도지수 평가)

  • Bongjun Jung;Dongsoo Kong
    • Journal of Korean Society on Water Environment
    • /
    • v.39 no.6
    • /
    • pp.475-490
    • /
    • 2023
  • Chemical water quality suitability for species (Ephemera strigata, Ephemera separigata, and Ephemera orientalis-sachalinensis group) of the mayfly genus Ephemera (Order Ephemeroptera) was analyzed with probability distribution models (Exponential, Normal, Lognormal, Logistic, Weibull, Gamma, Beta, Gumbel). Data was collected from 23,957 sampling units of 6,664 sites in Korea from 2010 to 2021. E. orientalis-sachalinensis occurred at the range of BOD5 0.3~11.1 mg/L (the best-fit Lognormal model); T-P 0.007~0.769 mg/L (the Gumbel model); TSS 0.4~142.2 mg/L (the Lognormal model). E. strigata occurred at the range of BOD5 0.4~7.4 mg/L (the Gumbel model); T-P 0.007~0.254 mg/L (the Lognormal model); TSS 0.4~17.1 mg/L (the Lognormal model). E. separigata occurred at the range of BOD5 0.4~2.6 mg/L (the R-Weibull model); T-P 0.007~0.134 mg/L (the Lognormal model); TSS 0.7~10.0 mg/L (the Lognormal model). Habitat suitability range of E. orientalis-sachalinensis was estimated to be 0.4~1.9 mg/L (BOD5), 0.024~0.086 mg/L (T-P), 2.5~22.4 mg/L (TSS); that of E. strigata was 0.4~0.7 mg/L (BOD5), 0.007~0.018 mg/L (T-P), 0.0~1.7 mg/L (TSS); that of E. separigata was 0.0~0.4 mg/L (BOD5), 0.000~0.015 mg/L (T-P), 0.5~3.1 mg/L (TSS). In a relative comparision, E. orientalis-sachalinensis was estimated to be eurysaprobic, and narrowly adapted in high levels of T-P and TSS, E. strigata was estimated to be oligosaprobic and adapted in low levels of T-P and TSS, and E. separigata was estimated to be stenooligosaprobic and widely adapted in low level of T-P and TSS.

A study on Spatiotemporal Variations of distribution characteristics in Artificial Rivers of the Brackish Water Zone (기수역 인공하천에서 시공간적 수질분포 특성 연구)

  • Kim, Yoon-Jeong;Choi, Ok Youn;Han, Ihn-Sup
    • Journal of Korean Society of Water Science and Technology
    • /
    • v.26 no.6
    • /
    • pp.89-97
    • /
    • 2018
  • The purpose of this reaserch is to analyze the charateristics of water quality in space through the operation of ARA River in Artificial Rivers of the Brackish Water Zone. The spatial distribution measured water temperature and salt levels for the surface, middle and deep layers by dividing the four areas of Incheon, Sicheon, Gyeyang and Gimpo. Water temperature did not vary much by water depth and branch, and its purpose is to maintain stable water environment through correlation analysis and operation. To examine the temporal and spatial distribution patterns of the Arachon, we measured DO on the Incheon branch, Sicheon, Gyeyang and Gimpo branch twice a month, and on the surface, the temperature level, The water temperature did not vary much by depth and location, and the water temperature in January and March tended to rise from Incheon to Gimpo, with the average difference of 1.1 degrees during the same period. The salinity difference between Incheon and Gimpo sites was 3.3 psu deep and 5.4 psu deep. In particular, floodgates from July to September are found to be less than 10psu overall, which is considered to be a gas due to the effects of floods and the inflow of Gulpo Stream. D.O. is located in some areas due to summer rains. The hypoxic layer has been identified.Analysis of seasonal data shows that water temperature and DO are strongly correlated in autumn. It was found that the water temperature and salt levels in the fall showed a weak correlation.

Adsorption rate of Phosphate Corrosion Inhibitor in Carbon Steel pipe (탄소강관에서의 인산염 부식억제제농도 감소의 반응속도상수 평가)

  • Woo, Dalsik;Hwang, Byunggi
    • Journal of Environmental Impact Assessment
    • /
    • v.14 no.1
    • /
    • pp.17-24
    • /
    • 2005
  • This study was performed to evaluate the adsorption rate of phosphate corrosion inhibitor and reaction rate constant in drinking water distribution systems. The optimum concentration of corrosion inhibitor would vary depending on the quality of water, pipe materials, and condition of metal surfaces. The current adsorption study indicated that the residual phosphate concentration of the corrosion inhibitor decreased with the time as it adsorbed on the surface of pipe material. As time went by, the residual phosphate concentration became constant. It means that the formation of the corrosion protection film on metal surfaces is completed.

Effects of pH, Alkalinity, Chloride Ion on the Copper Pipe Corrosion (동관에서 pH, 알칼리도, 염소이온이 부식에 미치는 영향)

  • Jo, Kwan-Hyung;Kim, Sun-Il;Woo, Dal-Sik
    • Journal of Environmental Health Sciences
    • /
    • v.33 no.1 s.94
    • /
    • pp.43-48
    • /
    • 2007
  • This study investigated the effects of pH, alkalinity, and chlorine ion which are important water quality impact factors to the corrosion in the simulated distribution system where the copper pipe is affixed. The result shows that pitting index was increased as the alkalinity and chloride ion increase in the distilled water, but there was no relation to pH. Actually the uniform corrosion rate was decreased as the pH increase with the laboratory tap water. In conclusion, it is necessary to control the pH which stands above minimum 7.5 to prevent pitting corrosion in the copper pipe. Consequently, comprehensive research about the effect of lime soda($Ca(OH)_2$) which was used as a coagulation additive in the water treatment plant to pipe corrosion must be accomplished additionally.

A Study on the Simple Piped Water Supply System in a Rural Area (일부 농촌지역의 간이 상수도 운영실태와 개선 방안에 관한 조사연구)

  • 정문호
    • Journal of Environmental Health Sciences
    • /
    • v.17 no.1
    • /
    • pp.57-66
    • /
    • 1991
  • This study was carried out for 5 years between 1984 and 1986 and 1989 and 1990. This interviewers visited 292 households to evaluate the perception of the residents using .the. Simple Piped Water Supply (SPWS), and examined the pollution source surrounding 42 SPWS facilities and water quality by the chemical and microbiological method. The purpose of this study was to find out problems linked with SPWS and to investigate more efficient way of improvement in rural water supply. The results of the study are surmnarized as follows: 1) Approximately 55% of the sampled population have been served by simple piped water supply. 2) The drinking water was mostly taken from the springs in 16 sites and valley water in 26 sites. 3) Considering the type of distribution of the SPWS, there are 28 natural gravity systems and 14 pumping systems. 4) Out of the 180 SPWS in Chun Sung Area, 74% of the SPWS facilities were used more than ten years. In addition, 40% of residents expressed the need for repairs of old facilities. 5) 48% of the SPWS facilities are neighbored with pollution source. 6) 50% of the maintenance crews were not committed totheir job but instead, the facilities were operated by some residents or community leaders who were personally concerned about quality of the facilities. 7) About 85% of the residents answered that SPWS was convenient and helpful. 8) About 57% of the residents complaind that the amount of daily water supply is not adequate. 9) About 74% of the residents felt that the water quality is high for dringking water and therefore, 52% of the facilities were not properly chlorinated. But in contrast, the biochemical tests indicated that only 28% of the SPWS met the dringking water quality standards. 10) Maintenance cost per a household ranges form 500 to 2, 000Won (1 $ = 700 Won) a month. Most of the cost was to cover the power electric charge. For the effective maintenance and arrangement of the facilities, gorvermental financial support for the maintenance is strongly recommended.

  • PDF

Analysis of Non-Point Pollutants Outflow Pattern in Jinhae-Masan Basin (진해-마산만 유역에서 비점오염물의 유출양상 분석)

  • Lee, Beum-Hee
    • The Journal of Engineering Research
    • /
    • v.8 no.1
    • /
    • pp.107-118
    • /
    • 2006
  • The difficulties to build a 3-dimensional water quality model for the coastal water quality improvement and the environmental recovery estimation are the lack of periodic observed data and the many problems to observe continuously. I observed the rainfall and non-point pollutants outflow patterns in Jinhae-Masan basin as mid-step researches for the water quality simulation and management method development in a coastal area. I applied Landsat image system and Geographic Information System to analyze the runoff and non-point pollutants outflow patterns. A water quality simulation model (SWMM) applied to Jinhae-Masan basin with results of the land use distribution, non-point pollution loads, and watershed informations from GIS(IDRISI used). I proposed some improved survey and GIS application methods reflect upon the pollutant characteristics from the observed non-point pollutant outflow patterns.

  • PDF

Optimal Rechlorination for the Regulation of Chlorine Residuals in Water Distribution Systems (배수관망의 잔류염소 평활화를 위한 최적 재염소 처리)

  • Yoon, Jae-Heung;Oh, Jung-Woo;Choi, Young-Song
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.12 no.2
    • /
    • pp.90-98
    • /
    • 1998
  • The optimal rechlorination in water distribution systems was investigated by incorporating optimization techniques into a numerical water quality model. For a hypothetical system that consists of 10 junctions including a storage tank and 12 links, the bulk ($k_b$) and pipe-wall ($k_w$) decay-rate constants of chlorine residual are assumed to be 2.0 1/day and 1.5 m/day, respectively. It was also assumed that the lower and upper limits of chlorine residual in the network are 0.2 mg/L and 0.6 mg/L. When the chlorine source is only the storage tank (without rechlorination), the high levels of chlorine residual appear near the storage tank to maintain the chlorine residuals above the lower limit over the junctions. On the other hand, the chlorine residuals in the network are distribute within the desirable range (0.2 - 0.6 mg/L) after the optimal rechlorination through five injection sites including the storage tank. In case of a real water distribution system that comprises 28 junctions including a clear well and 27 links, the bulk and pipe-wall decay-rate constants are 0.3 1/day and 0.2 m/day, respectively. Before rechlorination, the required chlorine residual at the clearwell is 5.1 mg/L to keep the chlorine residuals above the minimum level (0.6 mg/L) over the junctions. By the optimal rechlorination at five injection sites, the chlorine residuals are distributed within a desirable range of 0.6 mg/L through 2.0 mg/L, which can avoid the excess of chlorine residuals near the clear well. Consequently, total chlirine doses are decreased by 81% in the hypothetical distribution network and 69 % in the real distribution network for satisfying the minimum chlorine residuals.

  • PDF

Assessment of Trophic State for Yongdam Reservoir Using Satellite Imagery Data (인공위성 영상자료를 이용한 용담호의 영양상태 평가)

  • Kim, Tae Geun
    • Journal of Environmental Impact Assessment
    • /
    • v.15 no.2
    • /
    • pp.121-127
    • /
    • 2006
  • The conventional water quality measurements by point sampling provide only site specific temporal water quality information but not the synoptic geographic coverage of water quality distribution. To circumvent these limitations in temporal and spatial measurements, the use of remote sensing is increasingly involved in the water quality monitoring research. In other to assess a trophic state of Yongdam reservoir using satellite imagery data, I obtained Landsat ETM data and water quality data on 16th September and 18th October 2001. The approach involved acquisition of water quality samples from boats at 33 sites on 16th September and 30 sites on 18th October 2001, simultaneous with Landsat-7 satellite overpass. The correlation coefficients between the DN values of the imagery and the concentrations of chlorophyll-a were analyzed. The visible bands(band 1,2,3) and near infrared band(band 4) data of September image showed the correlation coefficient values higher than 0.9. The October image showed the correlation coefficient values about 0.7 due to the atmospheric effect and low variation of chlorophyll-a concentration. Regression models between the chrophyll-a concentration and DN values of the Landsat imagery data have been developed for each image. The regression model was determined based on the spectral characteristics of chlorophyll, so the green band(band 2) and near infrared band(band 4) were selected to generate a trophic state map. The coefficient of determination(R2) of the regression model for 16th September was 0.95 and that of the regression model for 18th October was 0.55. According to the trophic state map made based on Aizaki's TSI and chlorophyll-a concentration, the trophic state of Yongdam reservoir was mostly eutrophic state during this study.

Rechlorination for residual chlorine concentration equalization in distribution system (급배수시스템에서 잔류염소 농도 균등화를 위한 재염소 처리)

  • Kim, Jinkeun;Han, Ji-An
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.28 no.1
    • /
    • pp.91-101
    • /
    • 2014
  • Three water treatment plants(WTPs) in Jeju island whose source water have different characteristics from those of the mainland of Korea were investigated. Coefficients of bulk water decay($k_b$) of free chlorine at $5^{\circ}C$ for ES, GJ, NW WTPs were $-0.003hr^{-1}$, $-0.002hr^{-1}$ and $-0.001hr^{-1}$ respectively based on bottle tests. To simulate the free chlorine variations in the distribution system using EPANET, ES WTP was chosen. Free chlorine concentrations of several sites were less than the drinking water quality standards(i.e., 0.1 mg/L); E5(0.03 mg/L), E6(0.02 mg/L), W21(0.02 mg/L) and W25(0.03 mg/L). To maintain more than 0.1 mg/L of free chlorine in the distribution system, at least 1.9 mg/L of chlorine was needed at the WTP, which suggested rechlorination was needed to supply palatable tap water to customers. Two sites, one that diverged into E5 and E6 in the east-line and another located before E21 in the west-line were selected for the appropriate rechlorination locations. The recommended rechlorination dosages were 0.42 mg/L for the east and 0.27 mg/L for the west. The simulated results indicated that the free chlorine could be reduced to 0.4 mg/L at the WTP with rechlorination, and taps with excessive free chlorine could be more stabilized(i.e., 0.1~0.4 mg/L).

Study on Major Mineral Distribution Characteristics in Groundwater in South Korea (국내 지하수의 주요 미네랄 분포 특성에 관한 연구)

  • Kim, Jeonghee;Ryoo, Rina;Lee, Jongsu;Song, Daesung;Lee, Young-Joo;Jun, Hang-Bae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.10
    • /
    • pp.566-573
    • /
    • 2016
  • In order to support effective usage of groundwater as an alternative water resource in future, we investigated distribution characteristics of minerals related with human health. While recent studies tended to focus on small scale, this study broadened research area up to nationwide scale to understand groundwater hydrology and regional, geological distributions of minerals in wide area; we investigated mineral distributions of national groundwater monitoring networks, developed GIS-based mineral maps, and reviewed correlation with geological features. As a result, calcium showed the highest concentration among 5 minerals (Ca, Mg, Na, K, Si) and potassium showed the lowest. Calcium concentration in limestone and sedimentary zone was the highest, and that in pore-volcanic-rock zone was the lowest. While calcium, magnesium and sodium showed differences in concentrations in intrusive-igneous-rock and sedimentary zone, potassium was not within geological features. When we studied regional differences, there were no tendency, but Jeju and Gangwon area showed differences in concentrations of calcium and silica.