• 제목/요약/키워드: Distribution of Air Temperature

검색결과 1,142건 처리시간 0.028초

녹지분포에 따른 기온변화 (Air Temperature Variation by Effect of Green Space Distribution)

  • 윤용한
    • 한국환경복원기술학회지
    • /
    • 제5권2호
    • /
    • pp.47-52
    • /
    • 2002
  • In this study, in order to find out relationship of green space distribution and lower air temperature effect, observed air temperature distribution in and out green space in the cloudy. On basis of the result, we are analyzed relationship of air temperature distribution in and out green space, of green space distribution and air temperature of, lower air temperature effect and the urban in between the green space by using regression analysis. According to the result, the higher temperature zone formed around urban, and the lower temperature zone was similar to shape of green space. In case of the green space, higher temperature zone is formed around paved surface and barren ground, lower temperature zone is done forest and water area. To compare air temperature of windward and leeward around green space, the windward formed the lower temperature zone and although the wind direction is not the leeward to the green space, air temperature formed lower temperature zone to the urban in between the green space.

저온공조용 취출구의 선정 (Selection of Diffuser for Lower Temperature Air Distribution System)

  • 박성규;유호준;최명신
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.484-492
    • /
    • 2008
  • Air Discharge pattern and even temperature distribution is critical for a successful lower temperature air distribution system, which would supply lower temperature air than normal HAVC system. Selection of appropriate diffuser is the most critical element in completing lower temperature system.

  • PDF

아트리움의 수직온도 분포해석 프로그램의 개발에 관한 연구 (A study on the Development of Vertical Air Temperature Distribution Model in Atrium)

  • 김용인;조균형;김광우
    • 태양에너지
    • /
    • 제17권3호
    • /
    • pp.3-11
    • /
    • 1997
  • Recently the construction of atrium buildings has increased but along with it many problems in thermal environment have arised. since the exterior wall of glass, indoor temperature is greatly influenced by weather conditions and since the space volume is very large, the vertical air temperature is not uniform. So, in this study, a Vertical Temperature Distribution Model was developed to predict the vertical air temperature of an atrium and evaluate the effects of the design parameters on the air temperature distribution of an atrium. To consider the characteristics of the vertical air temperature distribution in an atrium, the Satosh Togari's Macroscopic Model was used basically for the calculation of the vertical air temperature distribution in large space and the solar radiation analysis model and natural ventilation analysis model in atrium. And to calculate the unsteady-state inside wall surface temperature(boundary condition), the finite difference method was used. For the verification of the developed temperature distribution program, numerical evaluation of air flow by the ${\kappa}-{\varepsilon}$ turbulence model and in-situ test was conducted in parallel. The results of this study, the developed temperature distribution program was seen to predict the thermal condition of the atrium very accurately.

  • PDF

Prediction of Air Movement and Temperature Distribution at Different Store Methods Using 3-D CFD Simulation in Forced-Air Cooling Facility

  • Yang, G.M.;Koh, H.K.
    • Agricultural and Biosystems Engineering
    • /
    • 제3권2호
    • /
    • pp.65-72
    • /
    • 2002
  • Temperature is the most influential environment parameter which affects the quality change of agricultural products in cold storage. Therefore, it is essential to keep the uniform temperature distribution in the storage room. This study was performed to analyze the air movement and temperature distribution in the forced recirculating cold storage facility and to simulate optimum storage method of green groceries using 3-D CFD(three dimensional computational fluid dynamics) computer simulation which applied the standard $textsc{k}$-$\varepsilon$ turbulence model and FVM(finite volume method). The simulation was validated by the experimental results for onion storage and the simulation model was used to simulate the temperature and velocity distribution in the storage room with reference to the change of storage method such as location of storage, no stores, bulk storage, and pallet storage. In case of no stores, internal airflow was circulated without stagnation and consequently air movement and temperature distribution were uniform. In case of bulk storage, air movement was stagnated so much and temperature distribution of onion was not uniform. Furthermore, the inner temperature of onion roses more than the initial temperature of storage. In case of pallet storage, air movement and temperature distribution of onion were so uniform that the danger of quality change was decreased.

  • PDF

CFD ANALYSIS OF DISTRIBUTION OF AIR TEMPERATURE ON PLATFORMS OF A LARGE RAILWAY STATION IN SUMMER SEASON

  • Tsukamoto Kenji;Iino Akinaru;Tominaga Yoshihide
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2005년도 Proceedings of ISRS 2005
    • /
    • pp.173-177
    • /
    • 2005
  • The purpose of this study is to analyze the principal causes of increases in air temperature on platforms of railway station. We analyzed the distribution of air temperature on Shinkansen platforms at Station 'A' using Computational Fluid Dynamics (CFD). We focused on the factors that influence the temperature dynamics associated with heat generated by trains and station buildings and their effect on the ambient temperature on platforms. In the case of heat generated by trains, air temperature on Shinkansen platforms increased by 4 to 7 degrees compared to when trains generated no heat. When a 50-m high station building was located on the windward side of the platforms, air temperature on Platform X was 2 degrees higher than when the station buildings were absent. Air? temperature on platforms VII to IX increased progressively, and the maximum air temperature on platform VIII was 3 K higher than if station buildings were absent.

  • PDF

자연환기시스템을 부착한 발코니의 열적 특성에 관한 연구 (The Study on Thermal Characteristic of the Balcony with Natural Ventilation System)

  • 조성우
    • 설비공학논문집
    • /
    • 제17권4호
    • /
    • pp.347-354
    • /
    • 2005
  • This paper compared vertical temperature distribution between the existing balcony model without ventilator facilities and the improved balcony model with ventilator facilities using differential equation. As the air inside of balcony is heated by solar radiation this heated air is not exhausted in the existing balcony, remaining stagnant. The air temperature distribution was $26.7{\sim}29.3^{\circ}C$ in balcony without natural ventilator system. This heated air affected the rising air temperature of adjacent spaces such as living room and bedroom in the existing balcony. But, as the heated air inside of the improved balcony model is exhausted through natural ventilator facilities in summer, the air temperature in balcony has fallen. The air temperature distribution in improved balcony was $24.8{\sim}26.7^{\circ}C$ for the inlet air speed of 1 m/s and $24.6{\sim}26.7^{\circ}C$ for the inlet air speed of 3 m/s. The energy consumption of the improved balcony is 2.5 times less than of the existing balcony. The improved balcony with the closed damper makes a roll as the existing balcony in the aspect of the heating effect. When the heated air in the improved balcony is supplied, the air temperature is raised and the ventilation effect in adjacent spaces was improved.

가스터빈 연소기내의 고온공기 분무연소 해석 (Spray combustion with high temperature air in a Gas Turbine Combustor)

  • 조상필;김호영;박심수
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2004년도 제28회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.192-198
    • /
    • 2004
  • A numerical study was conducted to determine the effects of high temperature air, including equivalent ratio on flow field, temperature, evaporation, and overall temperature distribution in gas turbine combustor. A sector model of a typical wall jet can combustor, featuring introduction of primary air and dilution air via wall jet, was used in calculations. Flow field and temperature distribution were analyzed. Operating conditions such as inlet temperature and overall equivalent ratio were varied from 373 to 1300 K, and from 0.3 to 0.6, respectively, while any other operating conditions were fixed. The RNG ${\kappa}-{\varepsilon}$ model and eddy breakup model were used for turbulence and combustion model respectively. It was found that the increase with the inlet air temperature, velocity in the combustor is accelerated and evaporation of liquid fuel is not affected in primary zone, high temperature inlet air enhances the evaporation and improves overall temperature distribution factor.

  • PDF

Study on the Effect of Air Circulator on Temperature Distribution in an Oyster Mushroom Farm

  • Jeong, Won Geun;Lim, Hack Kyu;Kim, Tae Han
    • Journal of Biosystems Engineering
    • /
    • 제38권2호
    • /
    • pp.81-86
    • /
    • 2013
  • Purpose: Recently, domestic and abroad consumption of mushroom has been increasing. Especially, oyster mushroom has been the most consumed product, sharing one third of the mushroom market. The air temperature differences between relative positions of the mushroom farms were needs to be minimal. However, in reality, the air temperature differences ranged from 2 to $5^{\circ}C$. Because of this, the mushrooms are non-uniform growth as well as decrease in both quality and quantity. Although air circulators have been employed by oyster mushroom farms to minimize air temperature differences, no experiments have been performed to illustrate the effect of the air circulators. Methods: This experiment is designed to analyze the effect of the air circulation by constructing a prototype air circulator and measuring the air temperature when the circulator was position at different heights (50 cm, 150 cm, 200 cm) from the floor in the center. Result: The horizontal plane air temperature of the first growing bed when the air circulator was installed 50cm above the floor in the center, once not using the air circulators and the other time using the air circulators, yielded the air temperature differences of $8.6^{\circ}C$ and $1.8^{\circ}C$ and deviations of 2.82 and 0.60, respectively. The third growing bed's air temperature differences were $10.0^{\circ}C$, $1.6^{\circ}C$ and deviations 3.28, 0.64, each respectively. These outcomes proved that the use of air circulators minimized the air temperature difference and deviation. The use of air circulators helped minimize the air temperature differences and the derivations in oyster mushroom farm. Conclusion: The use of air circulators helped balance the air temperature distribution in oyster mushroom farm.

2차 공기 주입각이 소각로 내부의 온도 분포 균일도에 미치는 영향 (Effects of the angle of secondary air inlet on the uniformity of temperature distribution inside an incinerator)

  • 김성준;민인홍;박명호;박민주
    • 한국전산유체공학회지
    • /
    • 제5권3호
    • /
    • pp.8-15
    • /
    • 2000
  • This research is aimed to find out how the inlet angle of secondary air affects the uniformity of temperature distribution inside a small incinerator. A commercial code, PHOENICS, is used to simulate the thermal-flow field of an incinerator. The computational grid system is constructed by Multi-Block technique provided by PHOENICS. Numerical experiments are done with the five different angles of secondary air inlet. The uniformity of temperature distribution is evaluated by checking the standard deviation of temperature distribution in an incinerator. The computational results show that there is the minimum value of standard deviation at the certain angle of secondary air inlet, which means that there is an optimum angle of secondary air inlet that could improve the uniformity of temperature distribution in an incinerator. The optimum angle of secondary air inlet is between 30 degree and 45 degree in this particular case.

  • PDF

대향류형 보텍스 튜브의 노즐형상 변화011 따른 튜브 내부의 온도분포에 관한 실험적 연구 (An Experimental Study on the Characteristics of Temperature Distribution in Internal Space of a Tube for the Formal Change of Counterflow Type Vortex Tube)

  • 황승식
    • 한국자동차공학회논문집
    • /
    • 제10권4호
    • /
    • pp.69-76
    • /
    • 2002
  • The aim of this study is to provide fundamental informations that make it possible to use a cool stream and a hot stream simultaneously. We changed the pressure of compressed air that flows into a tube, the inner diameter of orifice that a cold stream exits, and the mass flow rate ratio. And in each case, we measured the temperature of a cold stream and a hot stream in each exit of a tube. Also we measured the axial and the radial temperature distribution in internal spare of a tube. From the study, fellowing conclusive remarks 7an be made. First, As the number of nozzles increase, separation point move into the hot exit. Second, When we use guide vane type nozzle, the axial temperature distribution constant over the 0.75 of air mass flow rate radio. Third, When we use Spiral type nozzle, axial and radial temperature distribution in the inner space is higher than another nozzle. Fourth, Axial and radial temperature distribution in the inner space vortex-tube is determined by separation point. And separation point is moved by changing of air mass flow rate ratio. At last, A heating apparatus is possible far vortex-tube to use.