Effects of the angle of secondary air inlet on the uniformity of temperature distribution inside an incinerator

2차 공기 주입각이 소각로 내부의 온도 분포 균일도에 미치는 영향

  • 김성준 (강원대학교 기계메카트로닉스공학부) ;
  • 민인홍 (강원대학교 기계메카트로닉스공학부) ;
  • 박명호 (강원대학교) ;
  • 박민주 (강원대학교 기계메카트로닉스공학부)
  • Published : 2000.12.01

Abstract

This research is aimed to find out how the inlet angle of secondary air affects the uniformity of temperature distribution inside a small incinerator. A commercial code, PHOENICS, is used to simulate the thermal-flow field of an incinerator. The computational grid system is constructed by Multi-Block technique provided by PHOENICS. Numerical experiments are done with the five different angles of secondary air inlet. The uniformity of temperature distribution is evaluated by checking the standard deviation of temperature distribution in an incinerator. The computational results show that there is the minimum value of standard deviation at the certain angle of secondary air inlet, which means that there is an optimum angle of secondary air inlet that could improve the uniformity of temperature distribution in an incinerator. The optimum angle of secondary air inlet is between 30 degree and 45 degree in this particular case.