• 제목/요약/키워드: Distribution lines

검색결과 1,026건 처리시간 0.033초

22.9kV 지중계통의 뇌과전압 해석 및 뇌서지 보호방안에 관한 연구 (A Study on the Lightning Overvoltage Analysis and Lightning Surge Protection Methods in 22.9kV Underground Distribution Systems)

  • 김상국;정채균;이종범;박왈서
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제53권8호
    • /
    • pp.454-460
    • /
    • 2004
  • The effects of surge arresters for protection of transmission systems against direct lightning strokes have already been reviewed using Electromagnetic Transients Program(EMTP). Distribution lines are spanned in much larger area than transmission lines, and therefore, are more susceptible to lightning strokes. We have modelled the 22.9kV underground distribution cable systems that have arresters and grounding wires. And this paper analyzes the overvoltages on underground distribution cable systems when direct lightning strokes strike on the overhead grounding wire using EMTP. Then we investigated that (1) the effects of lightning stroke according to underground distribution cable length (2) voltages at the riser pole and at the cable terminal according to installation of arrester. This study will provide insulation coordination methods for reasonable systems design in 22.9kV underground distribution cable systems.

고압 가공배전선의 노화된 ACSR-OC 도체에 대한 열화검출시스템 설계 (Development of Deterioration Detecting System for Aged ACSR-OC Conductors in HV Overhead Distribution Lines)

  • 김성덕;이승호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.232-235
    • /
    • 2000
  • Design and experiments of a nondestructive system to inspect deterioration of ACSR-OC (ACSR Outdoor Cross-linked Polyethylene Insulated Wire usually used in HV overhead distribution lines presented in this paper. ACSR-OC conductor built to pollutants air for a long period would be easily progress to corrode so that it may lead to the reduction of the effective cross section area of conductors. A fault diagnosis system consisting of a solenoid sensor, a constant current source with RF frequency signal processing unit and a motor driver/controller designed and implemented. This instrument can dot the sensor output variation due to deterioration corrosion, continuously. As a result, it was shown such corrosion detector can readily be utilized estimating the diameter change due to deterioration overhead distribution lines and in giving an warning or inform before severe aged conductor lead to fail.

  • PDF

신경 회로망-퍼지로직을 이용한 배전선로 사고 검출 기법의 개발 (Development of Fault Detection Algorithm on distribution lines using neural network & fuzzy logic)

  • 최정환;장성일;엄재필;박준식;김광호;김남호;강용철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 C
    • /
    • pp.1440-1443
    • /
    • 1999
  • This paper proposes fault detection method using a neural network & fuzzy logic on distribution lines. Fault on distribution lines is simulated using EMTP. The pattern of high impedance fault on pebbles, ground and short-circuit fault were take as the learning model. In this paper proposed fault detection method is evaluated on various conditions. The average values after analyzing fault current by FFT of even odd harmonics and fundamental rms were used for the neural network input. Test results were verified the validity of the proposed method

  • PDF

22.9[kV] 배전선로 주변의 전장과 자장의 분포 (Profiles of Electric and Magnetic Fields around 22.9[kV] Distribution Lines)

  • 이복희;;박종순;길형준
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제13권2호
    • /
    • pp.178-178
    • /
    • 1999
  • In recent years, the electromagnetic environments are varied with the increase of power consumption and the spread of household electric appliances. Most of the interests to date have concentrated in the area of human health effects associated with exposure to power frequency electric and magnetic fields, and thus the precise measurement and analysis are required. In this paper, the measurements and analysis of the extremely low frequency(ELF) electric and magnetic fields produced by actual 22.9[kV] distribution lines were performed. The experiments have been carried out by lateral profile, and the theoretical analyses were made by use of FIELDS program for the sate of comparison with the experimental data. Electric and magnetic field intensity were strong under power distribution lines, and were inversely proportional to lateral distance. The profiles of electric and magnetic fields were M and ∩ shapes, respectively, and the measured data were good in agreement with the theoretical results. Both the electric and magnetic field intensity were increased with increasing the measurement height.

신경회로망을 이용한 배전선 사고 검출 기법의 개발 (Development of Fault Detection and Classification Method in Distribution Lines)

  • 김광호;최정환;장성일;강용철;박종근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 C
    • /
    • pp.1114-1117
    • /
    • 1998
  • Recent applications of neural networks to power system fault diagnosis have provided positive results and have shown advantages in process speed over conventional approaches. This paper describes the application of neural network to fault detection and classification in distribution lines using the fundamental component, 2-5th harmonics index, even and odd harmonics index, and zero phase current. The Electromagnetic Transients Program (EMTP) is used to obtain fault patterns for the training and testing of neural networks. The proposed fault detection and classification method in distribution lines is obtained by analysing the difference among normal, HIF, ground fault, short circuit fault condition.

  • PDF

배전계통 이상전압 측정 시스템 구성에 관한 연구 (A Study on the Measurement Systems of Over-voltages in Distribution Systems)

  • 박상만;김준오;이흥호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부 B
    • /
    • pp.585-587
    • /
    • 1998
  • In 22.9 kV-Y distribution lines, Several kinds of over-voltages occur. These over-voltages are usually surge types except controling the bus voltages for line voltage drop. The measuring over-voltages in 22.9 kV lines is a very difficulty skill. This paper introduces the study on the measurement system of over-voltages in 22.9kV distribution lines. It has been researching in KEPCO since 1995.

  • PDF

삼선 지락사고 발생시 매트릭스형 한류기용 리액터의 전자장 분포 해석 (Electromagnetic Field Distribution of Reactors for Matrix-type SFCLs under Triple Lines-to-Ground Faults)

  • 정동철;한태희
    • 전기학회논문지
    • /
    • 제60권2호
    • /
    • pp.459-463
    • /
    • 2011
  • In this paper we reported the characteristics of 1 line, 2 lines and 3 lines-to-ground fault of matrix-type SFCLs (MFCLs) and the electromagnetic field distribution of reactors for MFCLs under the same cases of ground faults. To do this, we fabricated MFCLs with 6 reactors for 3 phases. Each reactor had the length of 270 mm and diameter of 80 mm. 6 reactors were made by Bakelite. We reported experimental results, including fault currents, fault voltages and magnetic field distribution according to phase differences between each phase. We confirmed that experimental results will be useful in next future plan for real power grid.

배전선로 원격 진단을 위한 ZigBee 무선통신 시스템 개발 (Development of ZigBee Wireless Communication System for Remote Diagnosis in Distribution Power Lines)

  • 이경섭;정동현
    • 한국전기전자재료학회논문지
    • /
    • 제28권9호
    • /
    • pp.602-606
    • /
    • 2015
  • This paper presents a ZigBee wireless communication system for remote diagnosis in overhead distribution power lines. The system is divided in three parts in the functional aspect - a host computer module, a remote controller module and a diagnostic system module. The host computer module designed as USB interface transmits control signals and receive data measured by sensor. The remote controller module operates the diagnostic system. Diagnostic system module communicates with internal main controller and host computer USB. Multiple communication channel is adopted for simultaneous operations of several diagnostic system. Dedicated protocol for each module is developed. The system is designed with a focus on low cost and small size suitable for lightweight and small diagnostic system.

On a Distribution-Free Test for Parallelism of Regression Lines Against Ordered Alternatives

  • Song, Moon Sup;Huh, Moon Yul;Kang, Hee Jeong
    • 품질경영학회지
    • /
    • 제15권2호
    • /
    • pp.50-54
    • /
    • 1987
  • A distribution-free rank test for parallelism of regression lines against ordered alternatives is considered. The proposed test statistic is based on the Kepner-Robinson's transformation. The null distribution of the proposed statistic is the same as that of the Wilcoxon signed rank statistic. But, the proposed procedure can be applied only to four or fewer regression lines. The results of a small-sample Monte Carlo study show that the proposed test is comparable with the parametric test in heavy tailed distributions.

  • PDF

딸기 전조재배 온실의 인공광 설치실태 및 조도분포 조사분석 (Current Status of Lighting System and Illumination Distribution in the Greenhouse for Light Culture of Strawberries)

  • 김태한;장익주;이경진
    • Journal of Biosystems Engineering
    • /
    • 제24권1호
    • /
    • pp.19-24
    • /
    • 1999
  • Motivated by the need for developing the more efficient lighting system for light culture of strawberries in the greenhouse, this paper aims at acquiring and suggesting more concrete and scientific foundation of illuminating position, numbers of light source by investigating the types of lighting system and illumination distribution in the greenhouse for light culture of strawberries. The results of investigation and experiment are summarized as following below: 1. The types of lighting system used in the greenhouse producing strawberries were classified as 1 line and 2 lines lighting system. 2. As for the arranging types of artificial light, 2 lines lighting system, were classified as Z-type, N-type and W-type. (Refer Fig. 3) 3. The results of illumination distribution for Z-type, N-type and W-type of 2 lines illuminating system in the greenhouse with a small size tunnel measured at the height of 1.5m from the ground with 220V, 100W lamp in 6m light gap showed that maximum illuminance are 961x, 1211x, 1251x, minimum illuminance are 4.41x, 4.71x, average illuminance are 33.71x, 43.11x, 44.51x and standard deviations are 28.31x, 35.41x, 38.31x at each types. 4. Proportion of the area below optimal illuminance to floor area at the two lines illuminating system of Z-, N-, and W-type in greenhouse were appeared as 39.4%, 26.0% and 26.3%, respectively. Also proportion of the area over optimal illuminance to floor area at the two lines illuminating system of Z-, N-, W-type in greenhouse were appeared as 16.8%, 14% and 14.7%, respectively. Thus N-type was superior to the others from the view points of optimal illumination distribution and energy saving.

  • PDF