• 제목/요약/키워드: Distribution lines

검색결과 1,027건 처리시간 0.023초

배전용 변압기를 통한 저압전원선으로의 뇌서지 전파 (Propagation of Lightning Surges on Power AC Lines through Distribution Transformers)

  • 이복희;이수봉;이동문
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 추계학술대회 논문집 Vol.15
    • /
    • pp.468-471
    • /
    • 2002
  • A strong need to improve the quality of electric power is increased because of increasing use of the sensitive and small-sized electronic devices. The surges on the low-voltage ac power lines are induced by nearby lightning return strokes, and the facilities for HA, OA, FA, ME as well as computer are easily damaged by high-voltage transients. The behaviors of lightning surge characteristics transferred from the primary winding to the secondary winding in distribution transformers using a Marx generator were experimentally investigated. The transfer characteristics of lightning surge associated with a custom service ground of secondary side were also examined.

  • PDF

섬락 단선 방지 장치에 의한 피복 절연 가공배전 선로의 유도뢰애 의한 단선 방지 (Arc Fusion Protection of Covered Conductors Using AFPD)

  • 이용한;정동학;하복남;남궁도;김명수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 D
    • /
    • pp.800-802
    • /
    • 1997
  • After flashover occurs on the overhead distribution line by lighting strokes(direct or induced), the power frequency arc current continues. If lightning flashover occurs on the overhead lines using covered conductors, the power frequency art current with fixed path overheats the conductor, and arc fusion fault can be occurred. There are two categories protecting or reducing methods of arc fusion faults caused by lightning stokes. - Reducing lightning flashover rate : G/W, LA, etc. - Protection by AFPD(Arc Fusion Protection Device) : power follow current interruption. This paper presents lightning surge phenomena on overhead distribution lines and protecting performance of arc fusion Protection devices to the lightning strokes nearby overhead line.

  • PDF

배전선로 무정전 공법의 현장 적용상의 문제점과 전망 (Application of outage-free work techniques to distribution lines)

  • 박중신;권오형;이재관
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 D
    • /
    • pp.966-968
    • /
    • 1997
  • Our country is still suffering from much work outage, nearly 80% of total outage time, in 22.9kV-Y multi-grounded distribution lines. Therefore, KEPCO which is the sole utility owned by the Korean government has developed outage-free work techniques to improve the reliability of power supply in Our country. This paper is to introduce the developing process and good effects of outage-free work techniques, and the equipment developed and applied in Our country. This paper will aid many utilities to try to reduce the work outage.

  • PDF

신경회로망을 이용한 배전선로 고저항 사고 검출 기법의 개발 (Development of a hight Impedance Fault Detection Method in Distribution Lines using Neural network)

  • 황의천;;김남호
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제13권2호
    • /
    • pp.212-212
    • /
    • 1999
  • This paper proposed a high impedance fault detection method using a neural network on distribution lines. The v-I characteristic curve was obtained by high impedance fault data tested in various soil conditions. High impedance fault was simulated using EMTP. The pattern of High Impedance Fault on high density pebbles was taken as the learning model, and the neural network was valuated on various soil conditions. The average values after analyzing fault current by FFT of evenr·odd harmonics and fundamental rms were used for the neural network input. Test results were verified the validity of the proposed method.

분압용 세라믹 적층 소자를 이용하 정밀 고전압 계측 시스템 (Precise High Voltage Measurement System Using Ceramic Stack Element for Voltage Divider)

  • 윤광희;류주현;박창엽;정영호;하복남
    • 한국전기전자재료학회논문지
    • /
    • 제13권5호
    • /
    • pp.396-401
    • /
    • 2000
  • In order to accurately measure the high voltage of 22.9[kV] power distribution lines we investigated the temperature dependence of measuring voltage on the number of stack layers in the voltage measurement system made from single and stack voltage divider capacitors (22, 44, 66 layers, respectively). Temperature coefficient of dielectric constant(TC$\varepsilon_{{\gamma}}$/)of voltage divider capacitors which were fabricated by BaTi $O_3$system ceramics showed the variations from -2.28% to +1.69% in the range of -25[$^{\circ}C$] ~50[$^{\circ}C$]) was decreased with increasing of stack number and the stack element of 66 layers showed the least error of $\pm$0.87%or of $\pm$0.87%.

  • PDF

배전전주에서의 까치 둥지짓기와 기피반응에 관한 연구 (Study on magpie nestling and avoiding action at electric pole)

  • 김동명;박상만;권태호;이병호;최원석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 추계학술대회 논문집 전기설비전문위원
    • /
    • pp.87-89
    • /
    • 2005
  • Most of electrical service outage in overhead distribution lines are due to the magpies. The magpies make the short circuit in building up there nests and the grounding fault in directly contacting with the energized conductors. This paper described the performance of the existing anti-magpie devices to prevent the fault due to birds in distribution lines the reaction tests for the magpies were carried out for the sensors to simulate them in there territory.

  • PDF

전기철도시스템에서 직격뇌에 대한 가공지선의 내뇌효과 (Shielding Effects of an Overhead Ground Wire in the Electric Railway Systems due to Direct Lightning Strokes)

  • 임성정;김재철;추동욱;정용철;창상훈
    • 조명전기설비학회논문지
    • /
    • 제15권3호
    • /
    • pp.91-96
    • /
    • 2001
  • 본 논문은 전기철도시스템 고압 배전선로에서 직격뇌에 의한 가공지선의 영향에 대해서 설명하였다. EMTP를 사용하여 가공지선과 보안기의 영향을 정량적으로 분석하였다. 또한 전차선로의 구조변경과 피격전류의 크기, 파미값의 변화에 대한 영향도 평가하였다. 분석결과 기존 시스템에 가공지선의 설치는 전기철도시스템 고압 배전선로에 유도되는 피격전압을 억제하는 효과가 있음을 입증하였다.

  • PDF

분압용 적층형 소자를 이용한 고전압 계측에 관한 연구 (A Study on the High Voltage Measurement using Stack element for Voltage Division)

  • 윤광희;이용우;류주현;박창엽;하복남
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 추계학술대회 논문집
    • /
    • pp.319-322
    • /
    • 1999
  • In order to accurately measure the high voltage of 22.9[kV] power distribution lines, we investigated the temperature dependence of measuring voltage for single element and stack elements(22, 44, 66 layers, respectively). When one line voltage is 13, 20O[V], the error of measuring voltage with temperature(-25[$^{\circ}C$]~50[$^{\circ}C$]) was decreased with increasing of stack number and stack element with 66 layers was the least error of ${\pm}0.87%$.

  • PDF

회귀직선에서 순서대립가설에 대한 비모수적 검정법 연구 (A study on a nonparametric test for ordered alternatives in regreesion problem)

  • 이기훈
    • 응용통계연구
    • /
    • 제6권2호
    • /
    • pp.237-245
    • /
    • 1993
  • 본 논문에서는 순서대립가설에 대하여 k개의 회귀직선의 평행선을 검정하는 비모수적 검정 법을 제안하였다. 검정통계량은 각 직선에서 얻은 기울기 추정량들에 가중치를 준죤키어 (Jonckheere)형태의 통계량이다. 제안된 통계량의 분포는 점근적으로 정규분포를 따르게 되 어, 검정법은 점근분포무관검정이 된다. 모수적 검정법과 비교한 점근상대효율은 바람직한 형태를 가지며, 기존의 비모수적 검정법과 비교하여도 더 효율적임을 보였다.

  • PDF

스위스 치즈 모델을 적용한 철도 감전사고 발생형태에 관한 연구 (A Study on the Form of Electric Shock Accident Using Swiss Cheese Model)

  • 유기성;김재문
    • 전기학회논문지
    • /
    • 제67권12호
    • /
    • pp.1711-1716
    • /
    • 2018
  • Unlike conventional transmission and distribution lines, catenary system for operating electric railway vehicles are composed of multi-conductor groups (feeder line, contact wire, messenger wire, protection wire) and are used for railway employees, public or passengers in the station yards. Electric shock hazards are exposed and electric shocks such as death or serious injury are occurring in electric railway vehicles, railway high-voltage distribution lines, and catenary system. In order to analyze the types of electric shock accidents on railway by systematic approach method, we modeled 'unsafe behavior classification' method using swiss cheese model. Based on this method, we derived the type of electric shock accidents about railway accidents during the last 5 years by analyzing the frequency of occurrence of human errors and unsafe acts, laws and regulations related to violations, and so on.