• Title/Summary/Keyword: Distribution generator

Search Result 547, Processing Time 0.124 seconds

Numerical Simulation of Duct Flow about Shape and Arrangement of Inlet Guide Vane to Increase the Temperature Uniformity (전치 가이드 베인 배치 및 형상에 따른 보일러 입구 온도분포의 수치해석 연구)

  • Lee, Su-Yun;Shin, Seung-Won
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.1172-1177
    • /
    • 2008
  • Diverging channel from gas burner exit to the inlet section of Heat Recovery Steam Generator (HRSG) has been re-designed for 1 MW steam supply and power generation system. Three different test geometries have been chosen for the numerical simulation. The existing design for 300 kW HRSG system (CASE B) has been improved by geometry and position changes of inlet guide vanes along with gas velocity entrance angle at the diverging channel inlet (CASE C). Both cases has been compared with the case where hot combustion gas is directly injected without any guide vanes (CASE A). Improved design shows overall uniform velocity and temperature distribution compared to existing design.

  • PDF

Micro Forming of Metallic Micro-parts and Surface Patterns by Employing Vibrational Load (진동 하중을 이용한 마이크로 부품 및 표면 패턴 성형 기술)

  • Na, Y.S.;Lee, J.H.;Lee, W.S.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2009.05a
    • /
    • pp.64-67
    • /
    • 2009
  • Vibrational micro-forming of pyramidal shape patterns was conducted for an Al superplastic alloy, Al 5083 and a Zr-based bulk metallic glass, $Zr_{62}Cu_{17}Ni_{13}Al_8$. A vibrational micro-forming system was specially designed for generating vibrational load by combining a PZT actuator with a signal generator. Single crystal Si micro dies with wet-etched pyramidal patterns were used as master dies for vibrational micro-forming. The micro-formed pattern height was increasing with increasing the frequency of the vibrational load. In particular, the vibrationally-microformed pattern height was similar or even higher than the statically-microformed pattern height when the load frequency exceeded about 125 kHz. It was also observed that the crystal grains affect the surface quality of the microformed pattern and the distribution of the pattern height in the die cavity array.

  • PDF

A Sigma-Delta Modulator With Random Switching Periods (랜덤 스위칭 주기를 갖는 시그마 델타 변조기)

  • Bae, Chang-Han;Kim, Sang-Min;Lee, Gwang-Won
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.10
    • /
    • pp.513-519
    • /
    • 2001
  • This paper proposed a random sigma-delta modulator(RSDM), which is constructed by a 1st order sigma-delta modulator(SDM) and a simple structured random binary generator(RBG). The 1st order SDM produces a switching pulse waveform which has the same low-frequency component as the reference input, while the RBG spreads the distribution of the number of sampling per switching cycle, and thus disperses the spectrum spikes in the output. The relationship between the harmonic spectra and the number of sampling per switching cycle is studied through computer simulations, and the frequency spectra of the RSDM are confirmed in an experimental setup.

  • PDF

A Study on Fuel Distribution for Generator's Efficiency and Cost Saying (발전기 효율향상 및 비용절감을 위한 연료배분에 관한 연구)

  • 박찬형
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 2002.05a
    • /
    • pp.221-224
    • /
    • 2002
  • 포항제철소에는 13개의 발전기가 있어 제철소에서 필요로 하는 전력을 자체적으로 945MWH 규모로 공급하고 있다. 발전소에서 사용되는 에너지원은 제철공정에서 부수적으로 발생하는 부생가스(BFG, COG, LDG, CFG)와 외부에서 구매하는 중유, LNG가 있다. 안정적인 전력공급과 비용절감을 위한 발전기 가동계획을 수립하기 위해서는, 조업상황에 따라 변동되는 전력소요량 및 부생가스 발생량을 예측하여 발전기별로 사용될 연료량을 배분하고, 발전기별 효율을 반영한 발전량을 결정하게 된다 이러만 발전기 가동계획 수립을 수작업에 의존하고 있어, 수시로 변화하는 상황에 신속한 대처가 곤란하고, 모든 요소를 고려하기가 어려워 에너지비용을 절감할 수 있는 기회손실의 우려가 있었다. 본 연구에서는 LP 및 NLP를 적응하여 발전기별 연료배분 및 발전량을 결정하는 과정을 자동적으로 수행하는 발전기 가동계획수립 Model을 개발하였다. Data 입·출력용으로 Excel, LP Package는 What's Best, Programming Language는 VBA(Visual Basic for Application)를 활용하였다.

  • PDF

Distributions of Local Supply and Exhaust Effectiveness according to the Room Airflow Patterns (실내 기류패턴에 따른 급기효율과 배기효율의 분포)

  • 한화택;최선호;장경진
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.9
    • /
    • pp.853-859
    • /
    • 2001
  • A pulsed tracer gas technique is applied to measure distributions of local mean age and residual life time of air in a half-scale experimental chamber. The room airflow patterns are flow-visualized by a Helium bubble generator for three different exhaust locations. A supply slot is located at the top of a right wall, and an exhaust slot is either at bottom-left(Case 1), bottom-right(Case 2), or top-left(Case 3) location. Results show that the distribution of LMA and LMR are different from each other, but both of them are closely related to the airflow pattern in the space. Results on overall room ventilation effectiveness are provided depending upon ventilation airflow rates for three different supply-exhaust configurations.

  • PDF

Simulation of a two-stage absorption heat pump cycle using treated sewage (하수처리수 이용 흡수식 열펌프 사이클의 시뮬레이션)

  • 이용화;신현준;최국광
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.3
    • /
    • pp.422-430
    • /
    • 1999
  • This paper concerns the study of a two-stage absorption heat pump cycle to utilize treated sewage. This two-stage cycle consists of coupling double-effect with parallel or series flow type and single effect cycle so that the first stage absorber and condenser produces hot water to evaporate refrigerant in the evaporator of the second stage. The effects of operating variables such as absorber temperature on the coefficient of performance have been studied for two-stage absorption heat pump cycle. The working fluid is lithium bromide and water solution. The efficiency of the two-stage absorption heat pump cycle has been studied and simulation results show that higher coefficient of performance could be obtained for the first stage with parallel flow type. The optimum ratio of solution distribution can be shown by considering the COP, the crystallization of solution and the generator temperature.

  • PDF

Grid Generation and flow Analysis around a Twin-skeg Container Ship (Twin-skeg형 컨테이너선 주위의 격자계 생성과 유동 해석)

  • 박일룡;김우전;반석호
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.41 no.1
    • /
    • pp.15-22
    • /
    • 2004
  • Twin-skeg type stern shapes are recently adopted for very large commercial ships. However it is difficult to apply a CFD system to a hull form having twin-skeg, since grid topology around a twin-skeg type stern is more complicated than that of a conventional single-screw ship, or of an open-shaft type twin-screw ship with center-skeg. In the present study a surface mesh generator and a multi-block field grid generation program have been developed for twin-skeg type stern. Furthermore, multi-block flow solvers are utilized for potential and viscous flow analysis around a twin-skeg type stern The present computational system is applied to a 15,000TEU container ship with twin-skeg to prove the applicability. Wave profiles and wake distribution are calculated using the developed flow analysis tools and the results are compared with towing tank measurements.

The effect of gas density on the drop trajectory and drop size distribution in high speed gas stream (고속기류에 분사된 액적궤적 및 입경분포에 미치는 주위 기체밀도의 영향)

  • Lee, C.H.
    • Journal of ILASS-Korea
    • /
    • v.5 no.3
    • /
    • pp.37-44
    • /
    • 2000
  • High velocity, gas-assisted liquid drop trajectories were investigated under well-controlled experimental conditions at elevated gas densities and room temperature. A monodisperse stream of drops which are generated by a vibrating-orifice drop generator were injected into a transverse high velocity gas stream. The gas density and air jet velocity were adjusted independently to keep the Weber numbers constant. The Weber numbers studied were 72, 148, 270, 532. The range of experimental conditions included studied the three drop breakup regimes previously referred as bag, stretching/thinning and catastrophic breakup regimes. High-magnification photography and conventional spray field photographs were taken to study the microscopic breakup mechanisms and the drop trajectories in high velocity gas flow fields, respectively. The parent drop trajectories were affected by the gas density and the gas jet velocities and do not show similarity with respect to the either Weber or the Reynolds number, as expected.

  • PDF

A Lecture Note on PU Method thru Calculation of a Simple DC Circuit and Voltage/Fault Analysis of Industrial Power Systems using Actual Data (PU법에 의한 DC 회로계산 및 실계통 데이터를 이용한 전압강하/고장계산 방법)

  • Lee, Sang-Joong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.12
    • /
    • pp.45-54
    • /
    • 2014
  • This paper presents a lecture note of pu method for power system analysis. The author tries to help students in class better understand the fundamental of pu calculation using a very simple DC circuit. And a voltage drop calculation by pu method for a distribution system is given to help understand the importance of the vector reference in AC circuit analysis. A short current calculation by pu method for a power system with a generator, transformer and transmission line is also presented to show how pu calculation can be applied to real power systems, in which all the data are the ones currently being used by KEPCO and other industrial sites.

Analysis on Voltage Compensating Effect of DVR using PSCAD/EMTDC (PSCAD/EMTDC를 이용한 DVR의 전압보상 효과분석)

  • Park, Sang-Ho;Choy, Young-Do;Park, Young-Shin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.9
    • /
    • pp.165-171
    • /
    • 2010
  • There are many researches on Power Quality Device to protect the critical load and power system as the nonlinear load and precision load are adopted into the power system recently. To analyze the voltage compensation of voltage sag and voltage swell by DVR, which is connected to the important load in series, this paper shows PSCAD/EMTDC simulation and its verification by comparing with the actual DVR output of 2MVA. DVR control scheme in this paper is applicable to compensate single-phase, 2-phases or 3-phases voltage sag as well as DVR for distribution system.