• 제목/요약/키워드: Distribution Transformers

검색결과 202건 처리시간 0.029초

배전용 변압기 고압측으로의 뇌서지 전파 (Propagation of Lightning Surges toward primary Side of Distribution Transformer)

  • 이복희;이수봉;김병근;이승칠;이동문;정동철
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2003년도 학술대회논문집
    • /
    • pp.269-272
    • /
    • 2003
  • The importance of the improving quality of electric power is being strongly raised, owing to an increasing use of sensitive and small-sized electronic devices and system. The transient overvoltage on low-voltage AC power distribution system are induced by direct or indirect lightning return strokes, and those can cause damage and/or malfunction of the utility system for borne automation, office automation and factory automation as well as medical equipments. The behavior of lightning surge transferred to the primary side from the primary side in distribution transformers were experimentally investigated the protection effect of low voltage SPD installed at the secondary side of distribution transformers was analyzed.

  • PDF

CO와 $CO_2$ 가스를 이용한 유입식 변압기 절연지의 열화진단에 관한 연구 (Degradation Diagnosis of Insulation Paper Using CO and $CO_2$ Gases in Oil Immersed Transformers)

  • 선종호;이상화;김광화
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제53권10호
    • /
    • pp.523-529
    • /
    • 2004
  • Faults of cellulosic insulations greatly affect the life span of oil immersed transformers because their performance recovery is impossible. Therefore, the reliable diagnosis technologies are needed for detection of the faults. Dissolved gas analysis technologies using CO and $CO_2$ gases have been widely used for fault diagnosis of cellulosic insulations. In this research, we described Degradation diagnosis of insulation paper CO and $CO_2$ gases in oil immersed Transformers using. We considered the distribution characteristics of CO, $CO_2$ gases' concentrations and ratios of $CO_2$/CO not only in serviced transformers but in experiments with typical fault causes such as heat, partial discharge and moisture. As result, the reliability of diagnosis results for the cellulosic insulations can be improved when the concentrations of CO, $CO_2$ and the ratio of CO/$CO_2$ satisfy each diagnosis criterion at a tim

병렬운전 변압기 전압제어 및 저압축 모선보호방식연구 (A Study of Voltage Control for Lower Side Parallel Transformer)

  • 윤기섭;백승도;최종혁
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.233-236
    • /
    • 2001
  • Parallel operation scheme to several transformers is adopted because of the load increase, economic problem, or load shedding. For the transformer's parallel operation, loads proportional to each transformer's capacity must be allotted, and circulation currents must be limited as much as without causing any problem in a real operation. But, both transformers in parallel operation can be tripped when either faults at lower voltage side of a transformer or faults in a bus occurs. Therefore, parallel operation scheme to distribution transformers in Korea is not adopted in a normal state but only when loaded or load-shedded. These are due to the insufficiency of the construction in communication network and AVR scheme. Besides that, those are because bus bar protection scheme to lower voltage side of a transformer is not applied. In spite of enormous initial investment costs, advanced countries take so much account of power system reliability and stable supply that they adopt the parallel operation scheme in a normal state. One of the problems in parallel operation is the overheat of transformers due to the excessive circulation currents. This paper presents the scheme that controls voltages between both transformers using circulation currents that occurs in parallel operation.

  • PDF

주상변압기 최대부하 추정을 위한 수용가 사용전력량 예측 (Working Electrical Energy Forecasting for Peak Load Estimation of Distribution Transformer)

  • 박창호;조성수;김재철;김두봉;윤상윤;이동준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 C
    • /
    • pp.929-931
    • /
    • 1998
  • This paper describes the peak load forecasting technique of distribution transformers with correlation equation. While customers are demanding safe energy supply, conventional correlation equation that is used for load management of distribution transformers in domestic has some problems. To get accurate correlation equation, se-correlation equation were examined using new collected using the measuring instrument dev for this study. It was recognized that the qua equation was the most accurate for peak forecasting from working electrical energy.

  • PDF

A Study on the Effective Utilization Plan through Field Investigation and Analysis with Power Transformers in Domestic Areas

  • Shin, Heung-Sik;Lee, Jae-Cheon;Bai, Seok-Myung;Kim, Seon-Gu;Kim, Jin-Tae;Kim, Gi-Hyeon;Jeong, Jong-Wook;Bang, Seon-Bae
    • 조명전기설비학회논문지
    • /
    • 제21권4호
    • /
    • pp.88-95
    • /
    • 2007
  • Korea is highly dependent on foreign countries for energy while at the same time having a high energy-consumption industrial structure. Therefore, logical improvements in energy use efficiency and nationwide energy saving are becoming more and more important in coping with the worldwidehigh oil prices and environmental issues such as listed in the Kyoto Protocol to the United Nations Framework Convention on Climate Change. Consequently, a study was conducted on the average annual load factor in domestic areas to set a reasonable and reliable technology standard plan for high-efficiency transformers. The average annual load factor in Korea was discovered to be 18.4[%] classified by industry. This factor is expected to be used in arranging a domestic standard for a minimum efficiency system for transformers, and in reviewing and supplementing the standard transformers plan for the High Energy-Efficiency Appliance Certification. The expected effect from the establishment of the technology standards plan for highly efficient transformers is the expansion of the manufacturing and distribution of highly efficient transformers that are suitable for domestic use. These will lead to electricity cost savings for users, strengthening the related industries' market competitive powers and the effective reduction of greenhouse gases on a national level by drastically reducing loss from transformers, which accounts for a large portion of the total electric supply losses.

변압기의 3차원 온도분포 해석 (3-D Analysis of Temperature Distribution in Transformers)

  • 오연호;송기동;선종호
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제52권9호
    • /
    • pp.434-441
    • /
    • 2003
  • This paper deals with the temperature characteristics according to the cooling medium and the duct size in model transformers. For the analysis and the temperature-rise tests, two 400kVA model transformers have been manufactured. One has been filled with the alpha oil as the cooling medium and constructed the duct sizes of $3\textrm{mm}$ and $5\textrm{mm}$ in the low-voltage and high-voltage windings respectively. The other has been filled the beta oil and the duct sizes were $4\textrm{mm}$ and $6\textrm{mm}$. The temperature-rise tests have been performed by the back-to-back method and the load factor has been controlled the range of 90%∼130%. The temperature values have been measured by the thermocouple and from the sixteen points in each transformer. A commercial CFD program "FLUENT" has been used for the analysis of temperature distribution. The geometry of transformer has been modeled to 3-dimensional by using the hybrid calculation mesh including the radiator. And also, the natural convection velocity has been measured at the oil top position, and compared with the calculated results.

배전 변압기의 통계적 기대 수명 평가 및 초기 고장제거 적정성 검토 (Distribution Transformer Statistical Expected Life Evaluation and Removal Adequacy Review)

  • 조종은;김상봉;이온유;김강식
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제8권2호
    • /
    • pp.79-86
    • /
    • 2022
  • Recently, the amount of maintenance is increasing due to the aging of power facilities, but the budget is constrained. Therefore, the importance of asset management that selects replacement priorities based on the failure probability and enhances investment effects is increasing. Because the number of distribution transformers is very large, the proportion of investment cost is very high. Therefore, it is important to select the investment priority by evaluating the reliable remaining life based on the failure probability. This paper evaluates the statistical expected life using the failure data of distribution transformers for the last 11 years and the current operation data. The hazard rate of distribution transformer and MV cable was compared with each other and the adequacy of early failure removal was reviewed and the statistical expected life corresponding to the cumulative failure probability B3% was calculated.

전력선 통신 기법을 활용한 변압기 식별 방법에 대한 고찰 (Study about Power Transformer Identification Method based on Power Line Communication Technology)

  • 변희정;최상준;손수국
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2015년도 추계학술대회
    • /
    • pp.1006-1009
    • /
    • 2015
  • 3상 4선식 배전계통에서 특정 수용가가 어떤 변압기로부터 공급되는지를 결정하기 위한 전력선 통신방식을 활용한 식별 방법이 제안된다. 이러한 배전계통에서 전력선 통신 신호의 전달 특성을 분석하기 위한 변압기, 3상 선로, 부하 등에 대한 수치해석 모델을 기술한다. 배전선로에 고주파 전력신호를 주입하여 분석 한 결과 고주파 신호는 배전선에서 전달 능력에 한계 능력을 갖는다. 보통 배전계통의 전력 변압기는 그러한 고주파 신호의 전달을 차폐하게 된다. 이러한 제안된 전송제한 방법을 사용하여 변압기를 식별하는데 적용한다. 새로운 형태의 전력선 변압기 식별시스템이 설계 및 구현된다. 시스템은 전력선 통신 모듈을 바탕으로 송수신기로 구성된다. 이론적 개념을 검증하기 위해서 일반 상업용 건물에서 실험이 행하여진다. 또한 MATLAB Simulink 시뮬레이터를 사용하여 개념에 대한 이해를 위한 시뮬레이션이 수행된다.

  • PDF

배전용 몰드변압기 적용을 위한 EMNC의 교류절연파괴특성 연구 (AC Insulation Breakdown Properties of the EMNC to Application of Distribution Molded Transformer)

  • 박재준
    • 전기학회논문지
    • /
    • 제62권5호
    • /
    • pp.649-656
    • /
    • 2013
  • A conventional epoxy-microsilica composite (EMC) and an epoxy-microsilica-nanosilicate composite (EMNC) were prepared in order to apply them to mold-type transformers, current transformers (CT) and potential transformers (PT). Nanosilicate was exfoliated in a epoxy resin using our electric field dispersion process and AC insulation breakdown strength at $30{\sim}150^{\circ}C$, glass transition temperature and viscoelasticity were studied. AC insulation breakdown strength of EMNC was higher than that of EMC and that value of EMNC was far higher at high temperature. Glass transition temperature and viscoelasticity property of EMNC was higher than those of EMC at high temperature. These results was due to the even dispersion of nanosilicates among the nanosilicas, which could be observed using transmission electron microscopy (TEM). That is, the nanosilicates interrupt the electron transfer and restrict the mobility of the epoxy chains.

AC 브리지 회로에 의한 주상 변압기의 감시 기법 (A Monitoring Technique of Pole Transformers using AC Bridge Circuit)

  • 윤용한;민경래;최도혁;김재철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.544-546
    • /
    • 2000
  • This paper presents a monitoring technique of pole transformers using AC bridge circuit. And to detect the capacitance in oil more effectively, this paper used AC bridge circuit. The sensor in oil which could be placed inside of the distribution transformer can measures the changes of capacitance in oil. And with the sensing of the upper part's capacitance, it is possible to determine the changes of the oil height. Establishment of the proposed system helps to build the confidence in monitoring of the pole transformers.

  • PDF