• 제목/요약/키워드: Distribution System Modeling

검색결과 758건 처리시간 0.028초

Analysis and probabilistic modeling of wind characteristics of an arch bridge using structural health monitoring data during typhoons

  • Ye, X.W.;Xi, P.S.;Su, Y.H.;Chen, B.
    • Structural Engineering and Mechanics
    • /
    • 제63권6호
    • /
    • pp.809-824
    • /
    • 2017
  • The accurate evaluation of wind characteristics and wind-induced structural responses during a typhoon is of significant importance for bridge design and safety assessment. This paper presents an expectation maximization (EM) algorithm-based angular-linear approach for probabilistic modeling of field-measured wind characteristics. The proposed method has been applied to model the wind speed and direction data during typhoons recorded by the structural health monitoring (SHM) system instrumented on the arch Jiubao Bridge located in Hangzhou, China. In the summer of 2015, three typhoons, i.e., Typhoon Chan-hom, Typhoon Soudelor and Typhoon Goni, made landfall in the east of China and then struck the Jiubao Bridge. By analyzing the wind monitoring data such as the wind speed and direction measured by three anemometers during typhoons, the wind characteristics during typhoons are derived, including the average wind speed and direction, turbulence intensity, gust factor, turbulence integral scale, and power spectral density (PSD). An EM algorithm-based angular-linear modeling approach is proposed for modeling the joint distribution of the wind speed and direction. For the marginal distribution of the wind speed, the finite mixture of two-parameter Weibull distribution is employed, and the finite mixture of von Mises distribution is used to represent the wind direction. The parameters of each distribution model are estimated by use of the EM algorithm, and the optimal model is determined by the values of $R^2$ statistic and the Akaike's information criterion (AIC). The results indicate that the stochastic properties of the wind field around the bridge site during typhoons are effectively characterized by the proposed EM algorithm-based angular-linear modeling approach. The formulated joint distribution of the wind speed and direction can serve as a solid foundation for the purpose of accurately evaluating the typhoon-induced fatigue damage of long-span bridges.

Characteristic Impedances in Low-Voltage Distribution Systems for Power Line Communication

  • Kim, Young-Sung;Kim, Jae-Chul
    • Journal of Electrical Engineering and Technology
    • /
    • 제2권1호
    • /
    • pp.29-34
    • /
    • 2007
  • The input and output impedances in a low voltage distribution system is one of the most important matters for power line communication because from the viewpoint of communication, the attenuation characteristic of the high frequency signals is greatly caused by impedance mismatch during sending and receiving. The frequency range is from 1MHz to 30MHz. Therefore, this paper investigates the input and output impedances in order to understand the characteristic of high frequency signals in the low voltage distribution system between a pole transformer and an end user. For power line communication, the model of Korea's low voltage distribution system is proposed in a residential area and then the low voltage distribution system is set up in a laboratory. In the low voltage distribution system, S parameters are measured by using a network analyzer. Finally, input and output impedances are calculated using S parameters.

대면적 유기EL 양산 장비 개발을 위한 증착 공정 모델링 (Evaporation Process Modeling for Large OLED Mass-fabrication System)

  • 이응기
    • 반도체디스플레이기술학회지
    • /
    • 제5권4호
    • /
    • pp.29-34
    • /
    • 2006
  • In order to design an OLED(Organic Luminescent Emitting Device) evaporation system, geometric simulation of film thickness distribution profile is required. For the OLED evaporation process, thin film thickness uniformity is of great practical importance. In this paper, a geometric modeling algorithm is introduced for process simulation of the OLED evaporating process. The physical fact of the evaporating process is modeled mathematically. Based on the developed method, the thickness of the thin-film layer can be successfully controlled.

  • PDF

배전 시스템의 고조파 분석 및 모델링에 관한 연구 (Harmonics Analysis and Modelling for Distribution System)

  • 성병화;왕용필;정형환;박희철;박인표
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.267-269
    • /
    • 2004
  • Recently, due to increasing the application of power electronic equipment, harmonics generated from the non-liner load are fairy produced. Harmonics can cause a distribution problems such as the overheating of distribution transformer, the breakdown of device and communication interference. Interest about power quality decline of distribution system is very increased. In this paper, we are measured the harmonic voltage and current of distribution system to analyze harmonic characteristics, and it is analyzed Total Harmonic Distortion(HTD). Also, we are modeled distribution system using PSCAD/EMTDC. And it is analyzed harmonic voltage and current in steady-state. The study result have been indicated the utility about harmonics analysis and modeling for distribution system.

  • PDF

Generalized Reliability Centered Maintenance Modeling Through Modified Semi-Markov Chain in Power System

  • Park, Geun-Pyo;Heo, Jae-Haeng;Lee, Sang-Seung;Yoon, Yong-Tae
    • Journal of Electrical Engineering and Technology
    • /
    • 제6권1호
    • /
    • pp.25-31
    • /
    • 2011
  • The purpose of power system maintenance is to prevent equipment failure. The maintenance strategy should be designed to balance costs and benefits because frequent maintenance increases cost while infrequent maintenance can also be costly due to electricity outages. This paper proposes maintenance modeling of a power distribution system using reliability centered maintenance (RCM). The proposed method includes comprehensive equipment modeling and impact analysis to evaluate the effect of equipment faults. The problem of finding the optimum maintenance strategy is formulated in terms of dynamic programming. The applied power system is based on the RBTS Bus 2 model, and the results demonstrate the potential for designing a maintenance strategy using the proposed model.

USER MOBILITY AND CHANNEL HOLDING TIME MODELING IN MICROCELLULAR SYSTEMS

  • Kim, Sehun;Lee, Ki-Dong
    • 한국경영과학회:학술대회논문집
    • /
    • 한국경영과학회 1998년도 추계학술대회 논문집
    • /
    • pp.186-189
    • /
    • 1998
  • In this paper, we provide a mathematical formulation to describe the random mobility of users in cellular radio systems. With this, we can also study tile cell sojourn time (CST) distribution as well as the channel holding time (CHT) distribution. The study on user mobility enables to improve the resource management in cellular radio systems. We provide a versatile analysis tool that improves the limit of simplified analyses.

  • PDF

박막두께 예측을 위한 증착 공정 모델링에 관한 연구 (Study on Evaporating Process Modeling for Estimation of Thin-film Thickness Distribution)

  • 이응기;이동은;김숙한
    • 한국반도체및디스플레이장비학회:학술대회논문집
    • /
    • 한국반도체및디스플레이장비학회 2006년도 춘계학술대회
    • /
    • pp.156-159
    • /
    • 2006
  • In order to design an evaporation system, geometric simulation of film thickness distribution profile is required. In this paper, a geometric modeling algorithm is introduced for process simulation of the evaporating process. The physical fact of the evaporating process is modeled mathematically. Based on the developed method, the thickness of the thin-film layer can be successfully controlled.

  • PDF

PSCAD/EMTDC를 활용한 LVDC 고장분석 (A Study on the Fault Analysis of the LVDC Using PSCAD/EMTDC)

  • 김수환;최규완;문종필;김태훈;김주용
    • 전기학회논문지P
    • /
    • 제65권3호
    • /
    • pp.219-223
    • /
    • 2016
  • DC microgrid system is attracted attention in the world, because DC distribution system is more energy efficient than AC distribution system. To analyse the contribution effects of distributed generation(DG) in LVDC distribution system through modeling the Rectifier, DC/DC converter, Energy Storage System(ESS) and Photovoltaic(PV). using PSCAD/EMTDC. This paper analyses fault response characteristics in LVDC distribution system according to the interconnection and islanding operation of DG. Based on research results on the paper, direction for development of fault current reduction method for LVDC distribution system is suggested.

EMTDC를 이용한 DSTATCON 설치 효과 분석 (Analysis of System Performance on DSTATCON Installation using EMTDC)

  • 유일도;최영준;홍순옥;이학성;전영수;이기선
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 C
    • /
    • pp.943-945
    • /
    • 1998
  • This paper presents a method of modeling of DSTATCON (Distribution-line Static Condenser) for installation in a specific plant and analyze the effectiveness of the DSTATCON from the viewpoints of voltage regulation and harmonic mitigation in a distribution line. For the reliable modeling, detailed information on distribution system and loads is performed by field measurements. The DSTATCON has been modeled according to the control algorithm of real controller. The effectiveness of the DSTATCON installation is verified by simulation using EMTDC.

  • PDF

지하수 히트펌프 시스템의 대수층 활용 사레 연구 (Study on the aquifer utilization for a ground water heat pump system)

  • 심병완;이철우
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 추계학술대회
    • /
    • pp.32-35
    • /
    • 2006
  • The validation of a groundwater source heat pump system installation site is estimated by bydrogeothermic model ing. The hydraulic characteristics of the aquifer system is evaluated from pumping and recovery tests. In addition, the temperature distribution by the pumping and the injection of groundwater, and water level fluctuations are simulated by numerical modeling. The total cooling and heating load for the building is designed as 120RT(refrigeration ton) and the ground water source heat pump system covers 50RT as a subsidiary system The scenario of heat pump operation is organized as pumping and inject ion of groundwater that is performed for 8 hours per day in cooling mode for 90 days during the summer season The heat transfer by the injected warm water is limited near the inject ion wells in the simulated temperature distribution. The reason is that the given operation time is too short to expect broad thermal diffusion in large volume of the aquifer in the simulation time The simulated groundwater level and temperature distribution can be used as important data to develope an energy effective pumping and injection well system. Also it will be very useful to evaluate the hydraulic capacity of a target groundwater reservoir.

  • PDF