• Title/Summary/Keyword: Distribution Control Center

Search Result 686, Processing Time 0.028 seconds

Robust Safety Circuits for DC Powered Home Appliances in Transient State

  • Ahn, Jung-Hoon;Kim, Yun-Sung;Lee, Byoung-Kuk
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.6
    • /
    • pp.1967-1977
    • /
    • 2014
  • In this paper, for the development of a safe and reliable DC home appliance suitable for DC home power supply system, we classified a number of inherent problems with help of the comparative analysis of existing AC and new DC home appliance. Several new technical problems of DC home appliances are mainly linked to the DC transient state. Among them, this paper concentrates on start-up inrush current problem, uni-polarity problem, and heavy DC load control problem. And to address these problems, we herein present an implementation of robust safety circuits for DC home appliances. Specifically, we investigate several multi-circuit countermeasures and select the best among them through comparative evaluation, based on theoretical, simulational, and experimental results.

DEVELOPMENT and THERMAL DISTRIBUTION of an RF CAPACITIVE HYPERTHERMIA SYSTEM (고주파 유전가열형 온열암치료기의 개발과 가온특성)

  • Park, Mig-Non;Lee, Sang-Bae;Park, Duk-Kyu;Chu, Sung-Sil;Jung, Mi-Hyang
    • Proceedings of the KIEE Conference
    • /
    • 1987.07b
    • /
    • pp.1309-1312
    • /
    • 1987
  • Hyperthermia for the treatment of cancer has been introduced for a long time and the biological effect for the use of hyperthermia to malignant tumors has been well established and encouraging clinical results has been observed. Unfortunately, the engineering or technical aspects of hyperthermia for the deep seated tumors has not been satisfactory. We have researched and developed the radiofrequency capacitive hyperthermia system (GHT- RF8). It was composed with 8-9 MHZ RF generator, capacitive electrode, matching system, cooling system, temperature measuring system and control computer. The thermal profile was investigated in agar phantom, animals and in human tumors, which was heated with capacitive RF device.

  • PDF

Performance Enhancement of a PEMFC by Modification of Air Inlet Flow Header Configuration (공기측 입구헤더의 형상 개선을 통한 고분자 전해질 연료전지의 성능 향상)

  • Kim, Won-Nyun;Kim, Yun-Ho;Kim, Seo-Young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.4
    • /
    • pp.339-345
    • /
    • 2007
  • In the present study, a 10-cell PEMFC stack with straight type cathode flow channels is employed to investigate the effect of inlet air flow header configuration on the overall fuel cell performance. Four different types of inlet flow headers are considered and the flow patterns according to the air inlet flow header configuration are numerically obtained. The computed result for a modified header predicts about 8.5% improvement in the air flow distribution at 10-cell cathode channel inlets. Experiments are also carried out to confirm the numerical findings by measuring actual air flow distributions and the polarization curves of the PEMFC stack.

Implementation of the Base Station Controller in IMT-2000 System (IMT-2000 시스템의 제어국 기능 구현)

  • Lee, Dong-Myeong
    • The Transactions of the Korea Information Processing Society
    • /
    • v.7 no.8S
    • /
    • pp.2748-2756
    • /
    • 2000
  • IMT-2000 시스템(International Mobile Telecommunications-2000 system)은 음성, 화상, 및 데이터 서비스등 멀티미디어 서비스 제공을 목표로 기존의 디지털 이동통신 시스템에 적용된 기본 기술에 새로운 시스템 개념과 각종 응용기술 및 망 기술이 접목된 차세대 이동통신 시스템이다. 본 논문에서는 동기방식의 IMT-2000 시스템의 핵심 시스템인 제어국(BSC : Base Station Controller)의 무선 트래픽 및 신호접속기능, 이동호 제어기능 및 운용보전기능의 설계 및 구현에 대하여 논하고자 한다. 또한, IMT-2000 시스템의 호처리 절차 및 핸드오프 처리절차를 제시한다. 주로 BSC의 서브시스템인 AIS(ATM Interconnection Subsystem), BIS(BTS Interface Subsystem), SDS(Selector Distribution Subsystem), CSS(Control & Signal Subsystem) 및 BEMS(Base station Element Management Subsystem)의 구조와 기능, 그리고 MS(Mobile Station),BTS(Base Station Transceiver Subsystem), BSC 및 MSC(Mobile Switching Center)간의 호처리 기능, 절차(핸드오프 기능 포함)를 설계, 구현하였다.

  • PDF

A New Assessment for the Total Harmonic Contributions at the Point of Common Coupling

  • Han, Jong-Hoon;Lee, Kyebyung;Song, Chong Suk;Jang, Gilsoo;Byeon, Gilsung;Park, Chang-Hyun
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.1
    • /
    • pp.6-14
    • /
    • 2014
  • A new method to determine the total harmonic contributions of several customers and the utility at the point of common coupling is presented. The proposed method can quantify the individual harmonic impact of each suspicious harmonic source at the point of common coupling. The individual harmonic impact index is then used to assess the total harmonic contribution of each harmonic source. This index can be calculated by the results processed from instantaneous harmonic voltage and current phasor values. The results demonstrate the performance of the proposed method in terms of steady-state accuracy and response to time-varying operating conditions. The proposed index can be used for billing purposes to control harmonic distortion levels in power systems.

Process Design to Prevent Internal & External Defects of Cold Extruded Products with Double Ribs (이중 리브를 가진 냉간 압출품의 내.외부 결함 방지를 위한 공정 설계)

  • 김동진;김병민
    • Transactions of Materials Processing
    • /
    • v.8 no.6
    • /
    • pp.612-619
    • /
    • 1999
  • Internal and external defects of an inner pulley for automobile air conditioner are investigated in this study. Inner pulley is a part of compressor clutch assembly of automobile air conditioner. In cold forging of inner pulley, the design requirement are to keep the same height of the inner rib and outer one and to make uniform distribution of hardness in the forged product. At the end of the forging of inner pulley, the piping defect as an external defect begins to form at the back center of the billet. The internal crack as an internal defect also occur at the adiabatic shear band which usually has maximum ductile fracture value. It is important to predict when the internal and external defects occur during the deformation process, in order to minimize the amount of discard that is generated. The finite element simulations are applied to analyze the defects. The validity of the computational results are examined by experiments. These computational results are in good agreement with the experimental ones.

  • PDF

Alcohol Consumption Behaviors and Ethnicity in Hawaii

  • Kim, Jeoung-Hee
    • Korean Journal of Health Education and Promotion
    • /
    • v.2 no.1
    • /
    • pp.115-132
    • /
    • 2000
  • The purpose of this study is to provide baseline information on the risk-taking health behavior of alcohol consumption in four ethnic groups, Caucasian, Chinese, Japanese, and Korean, residing in the State of Hawaii. Secondary data from the State-based Health Behavioral Risk Factor Surveillance System, designed by the Center for Disease Control, were used. The total sample analyzed for this study contained 6,068 persons. Univariate and logistic regression analysis were performed in order to determine sociodemographic profiles and the predictor variables to produce the findings of this study. The percentage distribution of six sociodemographic factors by race was very similar in all alcohol consumption factors, acute drinking, chronic drinking, and drinking and driving. In this study there were significant ethnic differences in alcohol consumption factors except drinking and driving.

  • PDF

Comparing calculation methods of storey stiffness to control provision of soft storey in seismic codes

  • Tabeshpour, Mohammad Reza;Noorifard, Azadeh
    • Earthquakes and Structures
    • /
    • v.11 no.1
    • /
    • pp.1-23
    • /
    • 2016
  • Numerous buildings have been damaged or destroyed in previous earthquakes by developing soft storey. Almost all the seismic codes have provisions to prevent soft storey in structures, most of them have recommended the ratio of stiffness between adjacent storeys, but none of them has proposed the method to calculate the storey stiffness. On the other hand a great number of previous researches on stiffness have been focused on approximate methods and accurate methods by using analytical softwares have been almost neglected. In this study, six accurate methods for calculating the storey stiffness have been studied on 246 two-bay reinforced concrete frames. It is shown with the results of the statistical study and structural analysis that method 3 in which there is no modification of the original model and the forces with triangular distribution similar to seismic forces are applied to the center of mass of all storeys has acceptable accuracy and desirable efficiency for designing and controlling structures.

Input-Constrained Current Controller for DC/DC Boost Converter

  • Choi, Woo Jin;Kim, Seok-Kyoon;Kim, Juyong;Lee, Kyo-Beum
    • Journal of Power Electronics
    • /
    • v.16 no.6
    • /
    • pp.2016-2023
    • /
    • 2016
  • This paper presents a simple input-constrained current controller for a DC/DC boost converter with stability analysis that considers the nonlinearity of the converter model. The proposed controller is designed to satisfy the inherent input constraints of the converter under a physically reasonable assumption, which is the first contribution of this paper. The second contribution is providing a rigorous proof of the proposed control law, which keeps the closed-loop system along with the internal dynamics stable. The performance of the proposed controller is demonstrated through an experiment employing a 20-kW DC/DC boost converter.

Grid Connected PV System with a Function to Suppress Disturbances caused by Solar-cell Array Instantaneous Output Power Fluctuation (태양전지어레이 순시 출력변동에 의한 외란의 억제기능을 갖는 계통연계형 태양광발전 시스템)

  • Kim, Hong-Sung;Choe, Gyu-Ha;Yu, Gwon-Jong
    • Solar Energy
    • /
    • v.19 no.4
    • /
    • pp.63-69
    • /
    • 1999
  • The conventional grid connected PV(Photovoltaic) system has a unstable output pattern due to its dependence on the weather condition, although solar-cell array averagely has a regular output characteristics to have a peak output nearly at noon. Therefore assuming the high density grid connection in the future, this unstable output pattern can be one of the main reasons to generate power disturbance such as voltage variation, frequency variation and harmonic voltage generation in low voltage distribution line. However general grid connected solar-cell system do not have functions to cope with these disturbances. Therefore this study proposed a advanced type grid connected PV system with functions to suppress output power fluctuation due to solar-cell array output variation and showed the levelling effect of fluctuation due to instantaneous array output variation.

  • PDF