• Title/Summary/Keyword: Distribution Automation

Search Result 470, Processing Time 0.044 seconds

The Development Plan of the Protection Device Auto-coordination Program in the Distribution Automation System (배전자동화 적용선로 보호기기 자동정정 프로그램 개발)

  • Kang, Moon-Ho;Ha, Bok-Nam;Lim, Seong-Il;Cho, Nam-Hun;Lee, Heung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2001.05a
    • /
    • pp.129-131
    • /
    • 2001
  • In order to improve the reliability of power service and the effective management of distribution power system. DAS (Distribution Automation system) is widely used in KEPCO(Korea Electric Power Corporation) branch offices. Based on the present protective device coordination program which used in KEPCO. this study presents the new concept about both protective device coordination program maximizing the characteristics of DAS and development plan of protective device auto-coordination program with the merits of DAS.

  • PDF

Small-Scale Distribution Automation System Training Simulator Development (소규모 배전자동화 시스템 교육훈련용 시뮬레이터 개발)

  • Kim, Jae-Sung;Lee, Tae-Hyung;Kang, Suk-Kyun;Song, Wan-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2000.07d
    • /
    • pp.2889-2891
    • /
    • 2000
  • We developed the training simulator for KEPCO operators to maintain small-scale distribution automation system effectively. The training simulator has the same screen form and operating environments in comparison with using system in field. It is to be wished that the operating techniques of KEPCO operators will progress to solve the fear of system operation and to training simulations of distribution conditions again and again.

  • PDF

An Improved Service Restoration Algorithm under Consideration of Abnormal Conditions in Distribution Automation Systems

  • Cho, Namhun;Kim, Insung;Lee, Sungwoo
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.1 no.1
    • /
    • pp.47-54
    • /
    • 2015
  • The most important function in distribution automation system (DAS) is the service restoration. KEPCO's current service restoration provides a very effective restoration service. However, it has been developed without the consideration of unexpected abnormal conditions that may occur while processing the sequence of switching operations. The objective of this paper is to provide practical service restoration schemes under consideration of abnormal conditions. The proposed service restoration schemes have been integrated to a branch office (B/O) in KEPCO. The proposed method strongly supports the conventional service restoration and adds to its value.

Implementation of Fiber Optic and Wireless Complex Communication Network for Distribution Automation using IEEE 802.11a WLAN technology (IEEE 802.11a WLAN 기술의 사용에 의한 배전자동화용 광무선 복합통신망의 구현)

  • Hwang, Jin-Kwon;Choi, Tae-Il
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.10
    • /
    • pp.49-57
    • /
    • 2010
  • In order to provide electricity to users economically and safely, distribution automation systems (DASs) monitor and operate components of distribution systems remotely through communication networks. The fiber optic communication network has been mainly installed for the DAS of Korea Electric Power Corporation (KEPCO) because of its huge bandwidth and dielectric noise immunity. However, the fiber optic communication network has some shortcomings that its installation cost and communication fee are expensive. This paper proposes a complex network where WLANs are combined with conventional fiber optic communication networks in order to expand DAS easily and inexpensively. A fixed wireless bridge communication unit (FWB-CU) for the proposed complex network is implemented using IEEE 802.11a WLAN technology. The proposed complex network is built actually to verify its feasibility experimentally as a DAS communication network.

A Study of the Terminal Developement for Distribution Automation System (배전 자동화용 단말장치 기술 개발및 전원 구성에 관한 연구)

  • Kye, Moon-Ho;Kim, Jong-Soo;Jung, Je-Wook;Nam, Hyo-Sung;Park, Jong-Jin
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.902-904
    • /
    • 1993
  • This paper contains the terminal developement for the feeder remote unit in Korea Distribution Automation System. This terminal unit has serval functions in order to do feeder auotmation as following, the open/close controls and gathering status informations of switchgears, getting line currents and voltages, distribution fault. So FRU has four modules to do those functions-Logic Controller, Relay Controller, Data Acquisition, Display, Power Supply etc. The FRU should be on allays, so AC power is supplied before & behind the switchgear. Power Supply is made up with AC/DC, DC/DC, Battery and/or SOLAR CELLS & CONTROLLER. It is important for the supply to protect against some Surges, because surges are happened so many times. Surge test is fellowing the standard IEC 801-5 or IEEE 587.

  • PDF

Multi-Agent based Distribution Protection Coordination Algorithm (Multi-Agent 기반의 배전계통 보호협조 알고리즘)

  • Lim, Il-Hyung;Choi, Myeon-Song;Lee, Seung-Jae
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.4_5
    • /
    • 2009
  • A new protection coordination algorithm in Multi-Agent based distribution automation system is proposed in this paper. Distribution network protection coordination is acted by normal state distribution operation. But, in more and more complex distribution network structure, it has a big problem that central server processed all measurement data, coordination setting and controls for operation. So, a algorithm to change coordination setting is proposed automatically in terminal devices which Recloser and OCR to include Multi-Agent concepts in distribution network.

  • PDF

Harmonic Analysis of the Effects of Inverter Nonlinearity on the Offline Inductance Identification of PMSMs Using High Frequency Signal Injection

  • Wang, Gaolin;Wang, Ying;Ding, Li;Yang, Lei;Ni, Ronggang;Xu, Dianguo
    • Journal of Power Electronics
    • /
    • v.15 no.6
    • /
    • pp.1567-1576
    • /
    • 2015
  • Offline inductance identification of a permanent magnet synchronous motor (PMSM) is essential for the design of the closed-loop controller and position observer in sensorless vector controlled drives. On the base of the offline inductance identification method combining direct current (DC) offset and high frequency (HF) voltage injection which is fulfilled at standstill, this paper investigates the inverter nonlinearity effects on the inductance identification while considering harmonics in the induced HF current. The negative effects on d-q axis inductance identifications using HF signal injection are analyzed after self-learning of the inverter nonlinearity characteristics. Then, both the voltage error and the harmonic current can be described. In addition, different cases of voltage error distribution with different injection conditions are classified. The effects of inverter nonlinearities on the offline inductance identification using HF injection are validated on a 2.2 kW interior PMSM drive.

Automation Development in Water and Wastewater Systems

  • Olsson, Gustaf
    • Environmental Engineering Research
    • /
    • v.12 no.5
    • /
    • pp.197-200
    • /
    • 2007
  • Advanced control is getting increasingly demanded in water and wastewater treatment systems. Various case studies have shown significant savings in operating costs, including energy costs, and remarkably short payback times. It has been demonstrated that instrumentation, control and automation (ICA) may increase the capacity of biological nutrient removing wastewater treatment plants by 10-30% today. With further understanding and exploitation of the mechanisms involved in biological nutrient removal the improvements due to ICA may reach another 20-50% of the total system investments within the next 10-20 years. Disturbances are the reason for control of any system. In a wastewater treatment system they are mostly related to the load variations, but many disturbances are created also within the plant. In water supply systems some of the major disturbances are related the customer demand as well as to leakages or bursts in the pipelines or the distribution networks. Hardly any system operates in steady state but is more or less in a transient state all the time. Water and energy are closely related. The role of energy in water and wastewater operations is discussed. With increasing energy costs and the threatening climate changes this issue will grow in importance.

A Study on the Substation for the Bad Measuring Devices Detection and Correction (변전소 측정기기의 검.교정 알고리즘에 관한 연구)

  • Lee, H.J.;Park, S.M.;Kim, Y.H.;Kim, J.K.
    • Proceedings of the KIEE Conference
    • /
    • 2001.05a
    • /
    • pp.313-315
    • /
    • 2001
  • The power system automation, especially the substation automation is a major issue. so it has been widely studied each country in the world. Since the substation system includes lots of measuring devices. a lot of data and system information are transmitted to operators. The measured values usually have the error that results from the communication process, and it can degrade the reliability of estimated values. So. the detection and correction of measured values at a substation are important factors for substation automation. In this paper, we study the detection and col of measured values at the domestic 154kV/2 distribution substation of double bus structure study will be useful for expected economic dispatch measuring device's inspection and corr management by SCADA system operation, substation automation.

  • PDF

Analysis and Optimization of Bidirectional Exponential SC Power Conversion Circuits

  • Ye, Yuanmao;Peng, Wei;Jiang, Bijia;Zhang, Xianyong
    • Journal of Power Electronics
    • /
    • v.18 no.3
    • /
    • pp.672-680
    • /
    • 2018
  • A bidirectional exponential-gain switched-capacitor (SC) DC-DC converter is developed in this paper. When compared with existing exponential SC converters, the number of switches is significantly reduced and its structure is simplified. The voltage transfer features, voltage ripple across capacitors, efficiency and output impedance of the proposed converter are analyzed in detail. Optimization of the output impedance is also discussed and the best type of capacitance distribution is determined. A common function of the voltage gain to the output impedance is found among the proposed converter and other popular SC voltage multipliers. Experimental evaluation is carried out with a 6-24V bidirectional prototype converter.