• 제목/요약/키워드: Distributed generation systems

검색결과 356건 처리시간 0.027초

자동발전제어(Automatic Generation Control) 운용 개선방안 (A Study on Improvement Plan of AGC Operation)

  • 남재현;윤용범;박시우;추진부;김성학;이진수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 C
    • /
    • pp.1070-1072
    • /
    • 1999
  • Automatic Generation Control(AGC) is a control system whose objectives are to hold system frequency close to a specified nominal value and to maintain each unit's generation at the most economic value. It has been used to control the output of a generator by the control signal of the generator, but it is not appropriate to apply to generators which adopt the distributed control system. In this paper a method for improving the AGC operation is proposed, and the different response of each generator and various types of control systems of generators are considered. The interface among Remote Terminal Detector(RTU) and control systems and the direct delivery of the data between EMS and DCS also are proposed in the paper.

  • PDF

행원풍력단지와 연계된 성산변전소 모선의 전기품질 분석 (Power Quality Analysis of Sungsan Substation Bus Connected to Hangwon Wind Farm)

  • 안재현;고성민;나경윤;김세호;김호찬;김영환;최병천
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.146-148
    • /
    • 2005
  • The number of wind generation installations are growing substantially in Jeju, Korea. Many of these installations are significant in size and directly connected to the distribution system. In these distributed applications, it is not uncommon for the turbines to be connected near the end of a long rural distribution feeder from which end-users are served. Therefore, utility grid interconnection standards for interconnecting non-utility distributed generation systems are essential to both power system company and generation company. In this paper, it is investigated the power quality of Sungsan substation bus connected to Hangwon wind power generation farm.

  • PDF

분산전원 연계 운전 시 배전계통의 고조파 영향 (The effect of harmonics when the distributed generation is interconnected to the distribution system)

  • 박용업;강문호;윤기갑
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.541-542
    • /
    • 2006
  • The dispersed generation is recently increased introduction for the energy supply rationalization and effective management of power system. But the dispersed generation causes to the various trouble that isn't occurred in the past, for example, the two way systems have an effect on the mistake action of protection equipment and the power quality. In this paper, we research the influence on the harmonic when the dispersed generation is interconnected with distribution system. To achievement, we construct the interconnecting dispersed generation and distribution system which is applied to the permission of harmonic emission. After that, we simulate about the harmonic of distribution system interconnection dispersed generation by the PSCAD/EMTDC analyzing transient state of the power system.

  • PDF

6-DOF 시뮬레이터의 real-time 시스템 제어에 관한 연구 (Real-time system control for the 6-DOF simulation)

  • 김영대;김충영;백인철;민성기
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1989년도 한국자동제어학술회의논문집; Seoul, Korea; 27-28 Oct. 1989
    • /
    • pp.17-21
    • /
    • 1989
  • 6-DOE simulator system is designed to real-time processing for motion control, data acquisition, image generation and image processing etc.. In this paper, we introduce hardware and software design technologies for distributed processing, event-trapping, system monitoring and time scheduling procedure in 6-DOF simulator system design.

  • PDF

Robust Feedback Control Design for a Three-phase Grid-connected Inverter in Distributed Generation System

  • Lai, Ngoc Bao;Kim, Kyeong-Hwa
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2016년도 전력전자학술대회 논문집
    • /
    • pp.491-492
    • /
    • 2016
  • This paper presents a robust feedback control design to mitigate the effect of grid voltage disturbances for three-phase grid-connected inverters in distributed generation systems. The proposed strategy consists of two major design steps. First, the controller is synthesized using the internal model principle to achieve a good reference tracking and disturbance rejection performance. Then, the feedback gain is systematically obtained by solving the linear matrix inequality conditions which are directly derived from the stability criteria. The main contribution of this paper is that the complexity of control structure can be substantially reduced and transient response is improved as compared with the existing robust control design methods. The simulation results are given to prove the validity of the proposed control scheme.

  • PDF

Control of a Single Phase Unified Power Quality Conditioner-Distributed Generation Based Input Output feedback Linearization

  • Mokhtarpour, A.;Shayanfar, H.A.;Bathaee, M.;Banaei, M.R.
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권6호
    • /
    • pp.1352-1364
    • /
    • 2013
  • This paper describes a novel structure for single phase Unified Power Quality Conditioner-Distributed Generation (UPQC-DG) with direct grid connected DC-AC converter for low DC output DG systems which can be used not only for compensation of power quality problems but also for supplying of load power partly. This converter has been composed of one full-bridge inverter, one three winding high frequency transformer with galvanic isolation and two cycloconverters. Proper control based on Input Output feedback Linearization is used to tracking the reference signals. The simulation and experimental results are presented to confirm the validity of the proposed approach.

A Study on the Effect of Distributed Generation of the Reconfiguration of Distribution Networks

  • Nguyen, Tung Linh;Trinh, Trong Chuong;Truong, Viet Anh
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권4호
    • /
    • pp.1435-1441
    • /
    • 2017
  • Distributed generation (DG) in the future will play an important role in the electricity supply systems, in wich can provide DG capacity from a few hundred kW to tens of MW. However, it is connected to the local power grid, DG will have certain influence on the power quality of the power grid. One of the most significant effects is that they will change the configuration of the local power grid as well as affecting the operation mode of the grid. This paper presents a method of finding the optimal open loop, analyzing and selecting the appropriate mode of operation to reduce power losses of power distribution networks that includes DG.

헤테로다인 기법을 이용한 밀리미터파 신호 생성 (Millimeter-wave signal Generation using Heterodyne Technique)

  • 김정태
    • 한국정보통신학회논문지
    • /
    • 제7권6호
    • /
    • pp.1334-1340
    • /
    • 2003
  • 본 논문에서는 밀리미터파 대역의 신호 발생을 위한 헤테로다인 방식을 제안하였다. 향후, 무선 이동통신, 광대역 통신망에 사용되어질 밀리미터파 신호는 전기적 요소의 한계로 광학적인 요소에 의해 신호를 생성하는 방법을 연구 중에 있다. 광학적인 요소에 의한 여러 가지의 연구들이 광검출기의 기능, 밀리미터파 대역의 발진기의 개발 등이 이루어지고 있으며, 무선 통신망에 적용하기 위한 소자기술 등이 발전되고 있다. 본 논문에서는 향후 밀리미터파 대역에서 사용되어질 LMDS(Local Multi-point Distribution Service) 등의 시스템에서 광원으로 응용 가능한 방법을 제안하였다.

가정용 분산전원시스템의 성능 모사를 위한 전력부하 프로파일 예측 (Prediction of Electrical Load Profile for Use in Simulating the Performance of Residential Distributed Generation Systems)

  • 이상봉;조우진;이관수
    • 설비공학논문집
    • /
    • 제23권4호
    • /
    • pp.265-272
    • /
    • 2011
  • The electrical load profiles of end-users must be analysed properly to introduce distributed generation system efficiently. In this study, numerical simulation for predicting a residential electrical load profile was developed to satisfy categorized electricity consumption range. We applied bottom-up approach to compose electrical load profile by using data from official reports and statistics. The electrical load profile produced from the simulation predicted peak times of public report accurately and agreed well with the standard residential electrical load profile of official reports within average error of 16.2%.

Premium Power Quality Using Combination of Microturbine Unit and DC Distribution System

  • Noroozian, Reza;Abedi, Mehrdad;Gharehpetian, Gevorg
    • Journal of Electrical Engineering and Technology
    • /
    • 제5권1호
    • /
    • pp.103-115
    • /
    • 2010
  • This paper discusses a DC distribution system which has been supplied by external AC systems as well as local microturbine distributed generation system in order to demonstrate an overall solution to power quality issue. Based on the dynamic model of the converter, a design procedure has been presented. In this paper, the power flow control in DC distribution system has been achieved by network converters. A suitable control strategy for these converters has been proposed, too. They have DC voltage droop regulator and novel instantaneous power regulation scheme. Also, a novel control system has been proposed for MT converter. Several case studies have been studied and the simulation results show that DC distribution system including microturbine unit can provide the premium power quality using proposed methods.