• Title/Summary/Keyword: Distillation

Search Result 1,077, Processing Time 0.035 seconds

Experimental Distillation of Ethanol-Propanol Mixture Using a Horizontal Column (수평증류를 이용한 에탄올-프로판올 혼합물의 증류실험)

  • Kim, Byoung Chul;Kim, Young Han
    • Korean Chemical Engineering Research
    • /
    • v.51 no.1
    • /
    • pp.93-97
    • /
    • 2013
  • A lab-sized distillation experiment was conducted using small-size packings and a horizontal distillation column. The 6.7 mm Raschig ring type packings of stainless steel and a 40 mm glass column were used, and five independent electric heaters were installed in the axial direction to adjust the column inside temperature separately. The temperature was continuously distributed along the column length to provide equivalent equilibrium to the temperature for the separation. From the experimental results, a larger HETP of the column than the vertical distillation column was obtained, but it was found that the practical separation with proper processing capacity and separation efficiency was available.

Application of An Energy-Efficient Distillation System using Three Columns to Hexane Process (3기의 증류탑을 이용한 에너지 절약형 증류탑의 헥산공정에의 응용)

  • Kim, Young-Han;Hwang, Kyu-Suk
    • Korean Chemical Engineering Research
    • /
    • v.43 no.1
    • /
    • pp.39-46
    • /
    • 2005
  • Though a fully thermally coupled distillation column-an energy efficient distillation system-consumes less energy, it is not widely implemented in practice due to its operational difficulty. A 3-column distillation system having improved operability is proposed here, and its energy saving performance and application related issues are investigated from the implementation result to a practical hexane process. When an energy integration is employed, the proposed system requires 18% less energy than a conventional 2-column system, which is found from the HYSYS simulation. Though more control loops than the 2-column system are required, the proposed system has better controllability of product compositions and the pressure control of the system is easier.

Development of Multi Effect Distillation for Solar Thermal Seawater Desalination System (태양열 해수담수화 시스템을 위한 다중효용 담수기 개발)

  • Joo, Hong-Jin;Hwang, In-Seon;Kwak, Hee-Youl
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.1
    • /
    • pp.1-7
    • /
    • 2011
  • This study was accomplished to evaluate the performance of Multi Effect Distillation(MED) for solar thermal desalination system. It was designed Multi effect distillation with $3m^3$/day capacity and Shell&Tube type heat exchanger. Also, The effective heat transfer of Shell&Tube heat exchanger was used Cu(90%)-Ni(10%) corrugated tube. The parameters relating to the performance of Multi Effect Distillation are known as hot water flow rate. The experimental conditions for each parameters were $18^{\circ}C$ for sea water inlet temperature, $6m^3$/hour sea water inlet volume flow rate, $75^{\circ}C$ for hot water inlet temperature, 2.4, 3.6, and $4.8\;m^3$/hour for hot water inlet volume flow rate, respectively. The results are as follows, Development for Multi effect distillation was required about 40kW heat and 35kW cooling source to produce $3m^3$/day of fresh water. Based on the results of this study, It makes possible to secure economics of desalination system with solar energy which is basically needed development of high efficiency fresh water generator.

Separation Characteristics of Oxygen Isotopes with Hydrophobic PTFE Membranes (소수성 PTFE 막의 산소동위원소 분리특성)

  • 김재우;박상언;김택수;정도영;고광훈;박경배
    • Membrane Journal
    • /
    • v.13 no.3
    • /
    • pp.154-161
    • /
    • 2003
  • We measured the permeation characteristics of water with the hydrophobic PTFE membranes dependent on water temperature to confirm the separation of oxygen isotopes using Air Gap Membrane Distillation (AGMD) and Vacuum Enhanced Membrane Distillation (VEMD). Isotopic concentrations of $H_2^{16}O$ and $H_2^{18}O$ of the permeated water vapor were measured by Diode Laser Absorption Spectroscopy. Concentrations of the heavy oxygen isotopes in the permeated water vapor were decreased. Isotope separation coefficients for the hydrophobic PTFE membranes were 1.004∼1.01 depending on the experimental conditions. We observed the effects of air in membrane pores on the oxygen isotope separation. Isotope separation coefficients for the hydrophobic PTFE membranes without air in pores are higher than those for the membrane with air in pores.

Computer Simulation of the Effect of Pressurized/Depressurized Distillation Process on the Reduction of Separation Energy of Ethanol from Alcohol Fermented Broth (가압/감압 증류 공정이 발효 알콜의 분리 에너지 절감 효과에 미치는 영향에 관한 전산 모사)

  • 허병기;배천순;김휘동
    • Journal of Energy Engineering
    • /
    • v.2 no.1
    • /
    • pp.123-132
    • /
    • 1993
  • This work is focussed on the reduction of ethanol separation energy from alcohol fermented broth and categorized into the development of a computer program for the design of the pressurized/depressurized distillation process which has been regarded as one of the energy-reducing models for the conventional distillation process, the optimization of operating conditions of distillation towers by means of the developed program, and the evaluation of the total annual energy cost of pressurized/depressurized distillation columns compared with that of the conventional single distillation columns. The operating pressures are, in case of pressurized/depressurized distillation, 3103/760 mmHg, 3103/450 mmHg, 3103/160 mmHg, and in case of conventional distillation, 760 mmHg. The optimum reflex rations which the sum of the annual energy cost and the annual fixed cost for each process becomes minimum are 3.7475/2.9111 for the operating pressures of 3103/760 mmHg, 3.814/2.9712 for 3103/450 mmHg, 3.0783/2.2400 for 3103/150 mmHg, and 3.8544 for the atmospheric operating pressure. And the annual energy cost of pressurized/depressurized distillation process for the above-mentioned operating pressures is distributed between 42% and 47% of that of conventional distillation process.

  • PDF

A Study on the Water-Ethanol Separation by Membrane-Aided Distillation in Bio-Ethanol Process (바이오 에탄올 생산을 위한 Membrane-Aided Distillation에 의한 물-에탄올 분리공정에 관한 연구)

  • Jung, Heon;Choi, Young-Seok;Yang, Dae-Rook;Joo, Oh-Shim;Jung, Kwang-Deog
    • Clean Technology
    • /
    • v.14 no.2
    • /
    • pp.129-135
    • /
    • 2008
  • Nylon membrane was used to separate ethanol-water by a pervaporation method. Experimental equations were derived to use the simulation of membrane-aided distillation using nylon. The increases in permeation pressure resulted in the decrease in selectivity and energy consumption. The energy cost to enrich ethanol from 94 wt% to 99.5 wt% was calculated to be 53.3 won/kg of ethanol with extractive distillation and 18.9 won/kg of ethanol with a pervaporation method. The saving energy by the pervaporation method is consumed by recycling the permeate residue into the distillation column in the membrane-aided distillation column. Therefore, membrane with the high selectivity to minimize the permeate residue recycle is required to effectively enrich ethanol in the membrane-aided distillation method.

  • PDF

Fundamental Study on a Distillation Separation of a LiCl-KCl Eutectic Salt from Rare Earth Precipitates (희토류 침전물로부터 LiCl-KCl 공융염의 증류 분리에 관한 기초연구)

  • Yang, Hee-Chul;Eun, Hee-Chul;Kim, In-Tae
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.8 no.1
    • /
    • pp.65-70
    • /
    • 2010
  • The distillation rate on LiCl-KCl eutectic salt under different vacuums from 0.5-50 mmHg was first investigated by using both a non-isothermal and a isothermal thermogravimetric (TG) analysis. Based on the non-isothermal TG data, distillation rate equations as a function of the temperature could be derived. Calculated flux by these model flux equations was in agreement with the distillation rate obtained from isothermal TG analysis. A distillation rate of $10^{-4}-10^{-5}$ mole $cm^{-2}sec^{-1}$ is obtainable at temperatures less than 1300K and vacuums of 0.5-50 mmHg. About a 99% salt distillation efficiency was obtained after an hour at a temperature above 1150 K under 50 mmHg in a small scale distillation test system. An increase in the vaporizing surface area is relatively effective for removing residual salt in the remaining particles, when compared to that for the vaporizing time. Over 99.95% of total distillation efficiency was obtained for a 1-h distillation operation by increasing the inner surface area from $4.52cm^2$ to $12.56cm^2$.

Permeate Flux Analysis of Direct Contact Membrane Distillation (DCMD) and Sweep Gas Membrane Distillation (SGMD) (직접접촉식과 동반기체식 막증류 공정의 투과수 변화에 따른 비교해석)

  • Eum, Su-Hwan;Kim, Albert S.;Lee, Yong-Taek
    • Membrane Journal
    • /
    • v.21 no.3
    • /
    • pp.236-246
    • /
    • 2011
  • In this study, we used prepared a cylindrical module consisting 100 hollow fibers of commercialized (hydrophobic) polyethylene membrane of $0.4{\mu}m$ pore size and systematically studied performance of direct contact membrane distillation (DCMD) and sweep gas membrane distillation (SGMD) in terms of variation of permeate flux and salt rejection with respect to temperature drop across the membrane, salt concentrations in feed, and flow rates of cooling water and sweep gas. SGMD was regarded as DCMD with a sweep gas layer between permeate-side membrane surface and cooling water. Sweep gas flow decreases the permeate flux from that of DCMD by providing an additional gas-layer resistance. We compared DCMD and SGMD performance by using mass balance with a fitting parameter (${\omega}$), indicating fraction of permeate flow rate.

Feasibility study on shale gas wastewater treatment using membrane distillation (막 증발법을 이용한 셰일가스 폐수 처리 가능성 평가)

  • Cho, Hyeongrak;Choi, Yongjun;Lee, Sangho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.4
    • /
    • pp.441-447
    • /
    • 2016
  • Development of shale gas has drawn increasing attention since it is one of promising alternative energy resources. However, contamination of groundwater and surface water during the extraction of shale gas is becoming a serious environmental issues, which brings the needs to treat wastewater generated from hydraulic fracking. In this study, the feasibility of membrane distillation (MD) for the treatment of shale gas wastewater was investigated using a laboratory scale experimental setup. Flat-sheet MD membranes were used to treat produced water from a shale gas well in the United States. Different configurations such as direct contact MD (DCMD) and air gap MD (AGMD) were compared in terms of flux and fouling propensity. The foulants on the surface of the membranes were examined. The results suggest that MD can treat the shale gas produced water containing more than 200,000 mg/L of total dissolved solids, which is impossible by other technologies such as reverse osmosis (RO) and forward osmosis (FO). In this study, we investigated the possibility of processing and characterization of shale gas produce wastewater using membrane distillation. Laboratory scale membrane distillation experimental device was developed. It was compared the flat-sheet direct contact membrane distillation and flat-sheet air gap membrane distillation. AGMD flux in lower than the flux of DCMD, it was expected that the contamination caused by organic matters.

Energy Conservation and Exergy Comparison of a Fully Thermally Coupled Distillation Column (열복합 증류탑의 에너지 절감과 엑서지 비교)

  • Kim, Byoung Chul;Kim, Young Han
    • Korean Chemical Engineering Research
    • /
    • v.50 no.1
    • /
    • pp.55-60
    • /
    • 2012
  • The energy conservation and exergy loss of a fully thermally coupled distillation commercialized as the divided wall column are compared with those of a conventional two-column system for ternary separation. The used example for the comparison is the benzene-toluene-m-xylene separation process widely used in a petrochemical plant. The design procedure of the fully thermally coupled distillation column is explained, and the energy requirement is compared using the HYSYS. When the same numbers of trays are utilized, the fully thermally coupled distillation column uses 28.2% less energy and 10.4% more exergy loss. The increase of the exergy loss is due to the additional mixing from the bidirectional inter-linking and the temperature elevation in the reboiler from the increased pressure at the bottom of the main column.