• Title/Summary/Keyword: Distance measure

Search Result 1,797, Processing Time 0.026 seconds

Measurement and analysis of tractor emission during plow tillage operation

  • Jun-Ho Lee;Hyeon-Ho Jeon;Seung-Min Baek;Seung-Yun Baek;Wan-Soo Kim;Yong-Joo Kim;Ryu-Gap Lim
    • Korean Journal of Agricultural Science
    • /
    • v.50 no.3
    • /
    • pp.383-394
    • /
    • 2023
  • In Korea, the U.S. Tier-4 Final emission standards have been applied to agricultural machinery since 2015. This study was conducted to analyze the emission characteristics of agricultural tractors during plow tillage operations using PEMS (portable emissions measurement systems). The tractor working speed was set as M2 (5.95 km/h) and M3 (7.60 km/h), which was the most used gear stage during plow tillage operation. An engine idling test was conducted before the plow tillage operation was conducted because the level of emissions differed depending on the temperature of the engine (cold and hot states). The estimated level of emissions for the regular area (660 m2), which was the typical area of cultivation, was based on an implement width of 2.15 m and distance from the work area of 2.2 m. As a result, average emission of CO (carbon monoxide), THC (total hydrocarbons), NOx (nitric oxides), and PM (particulate matter) were approximately 6.17×10-2, 3.36×10-4, 2.01×10-4, and 6.85×10-6 g/s, respectively. Based on the regular area, the total emission of CO, THC, NOx, and PM was 2.62, 3.76×10-2, 1.63, and 2.59×10-4 g, respectively. The results of total emission during plow tillage were compared to Tier 4 emission regulation limits. Tier 4 emission regulation limits means maximum value of the emission per consumption power (g/kWh), calculated as ratio of the emission and consumption power. Therefore, the total emission was converted to the emission per power using the rated power of the tractor. The emission per power was found to be satisfied below Tier 4 emission regulation limits for each emission gas. It is necessary to measure data by applying various test modes in the future and utilize them to calculate emission because the emission depends on various variables such as measurement environment and test mode.

Dosimetric effects of couch attenuation and air gaps on prone breast radiation therapy (Prone Breast Phantom을 이용한 couch 산란영향 평가)

  • Kim, Min Seok;Jeon, Soo Dong;Bae, Sun Myeong;Baek, Geum Mun;Song, Heung Gwon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.2
    • /
    • pp.43-51
    • /
    • 2017
  • Purpose: The purpose of this study is to evaluate the dosimetric effects of couch attenuation and air gaps using 3D phantom for prone breast radiation therapy. Materials and method: A 3D printer(Builder Extreme 1000) and computed tomography (CT) images of a breast cancer patient were used to manufacture the customized breast phantom. Eclipse External Beam Planning 13.6 (Varian Medical Systems Palo Alto, CA, USA) was used to create the treatment plan with a dose of 200 cGy per fraction with 6 MV energy. The Optically Stimulated Luminescence Detector(OSLD) was used to measure the skin dose at four points (Med 1, Med 2, Lat 1, Lat 2) on the 3D phantom and ion-chamber (FC65-G) were used to perform the in-vivo dosimetry at the two points (Anterior, Posterior). The Skin dose and in-vivo dosimetry were measured with reference air gap (3 cm) and increased air gaps (1, 2, 3, 4, 5, 6 cm) from reference distance between the couch and 3D phantom. Results: As a result, measurement for the skin dose at lateral point showed a similar value within ${\pm}4%$ compared to the plan. While the air gap increased, skin dose at medial 1 was reduced. And it was also reduced over 7 % when the air gap was more than 3 cm compared to radiation therapy plan. At medial 2 it was reduced over 4 % as well. The changes of dose from variety of the air gap showed similar value within ${\pm}1%$ at posterior. As the air gap was increased, the dose at anterior was also increased and it was increased by 1 % from the air gap distance more than 3 cm. Conclusion: Dosimetrical measurement using 3D phantom is very useful to evaluate the dosimetric effects of couch attenuation and air gaps for prone breast radiation therapy. And it is possible to reduce the skin dose and increase the accuracy of the radiation dose delivery by appling the optimized air gap.

  • PDF

IN VITRO EVALUATION OF THE CONSISTENCY OF TWO ELECTRONIC APEX LOCATORS (2종 전자근관장측정기의 일관성에 관한 in vitro 연구)

  • Hwang, Gyu-Young;Roh, Byoung-Duck;Kim, Eui-Sung;Lee, Seung-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.1
    • /
    • pp.20-27
    • /
    • 2008
  • The purpose of this study was to evaluate the consistency of two electronic apex locators in vitro model. Materials consisted of fifty two extracted premolars and two electronic apex locators; Root ZX (J. Morita, Osaka, Japan) and E-Magic Finder Deluxe (S-Denti. Cheonan, Korea). After access preparation, the teeth were embedded in a saline-mixed alginate model. Canal lengths of each tooth were measured at "0.5" and "Apex" mark of the apex locators, respectively so that each tooth had two measurements from 0.5 and Apex points. The file was fixed at final measurement using a glass ionomer cement. The apical 4 mm from the apex was exposed to measure the distance from the file tip to the major apical foramen of each tooth. Average distances and standard deviations were used to evaluate the consistency. Results showed that all measurements of both Root ZX and E-Magic Finder located the major foramen the range of ${\pm}0.5\;mm$ level. Both apex locators showed better consistency at Apex mark than at 0.5 mark. The average distance of file tip-major foramen was - 0.18 mm at 0.5 mark and - 0.07 mm at Apex mark in Root ZX, - 0.25 mm at 0.5 mark and - 0.02 mm at Apex mark in E-Magic Finder. Standard deviation was 0.21 at 0.5 mark and 0.12 at Apex mark in Root ZX, 0.12 at 0.5 mark and 0.09 at Apex mark in E-Magic Finder.

IMRT and IMRS Checking the Dose Distribution in the Small Field Evaluation of Measurement by Changes in SAD (IMRT 및 IMRS에서 Small Field의 선량분포 확인시 SAD 변화에 따른 측정의 유용성 평가)

  • Ko, Seung-Young;Kim, Sung-Joon;Park, Gir-Yong;Son, Mi-Suk;Lee, Nam-Ki;Kim, Jin-Soo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.1
    • /
    • pp.33-39
    • /
    • 2010
  • Purpose: It is very important to confirm conformance of dose distribution that is formed with treatment planning from IMRS or IMRT. It has been a problem dropped accuracy and conformance when the field size is getting smaller because of character of the 2D ion chamber. Verification of MatriXX Phantom dose distribution with a change in the SAD. Dose distribution measurement and analysis to improve the accuracy and should be useful to evaluate the award. Materials and Methods: A use of Novalis linear accelerator 6 MV photon beams. In general, IMRS were 25 patients with small field size. The selected patients were divided into three groups on the basis of the field size. SAD was changed from 80 to 130 cm and field size to determine the dose distribution to the change, each dose was measured using MatriXX Phantom. Analysis of measured values obtained from the program for each patient through the treatment planning system comparison and analysis of the dose distribution and gamma values were expressed. Result: SAD 80, 100, and 120 cm in size in the gamma value to the investigation of patients less than $3\;cm^2$ average 0.939, 0.969, and 0.979, respectively. Patients with more than $5\;cm^2$ 0.962, 0.983, and 0.988, respectively. $5\;cm^2$ or more patients 0.982, 0.990, and 0.992, respectively. Conclusion: The error rate of less than $3\;cm^2$ field size is increased rapidly. If the field size is increased, resolution is increased by 2D ion chambers. It has been approved that it can be credible if it is around $3\;cm^2$ when measuring dose distribution using MatriXX. Adjusting geometric field size by changing SAD is likely to be very useful when you measure dose distribution using MatriXX.

  • PDF

Comparison between Response AC/A and CA/C Ratio according to Additional Spherical Powers and Prism Powers (가입렌즈 도수와 프리즘 굴절력 변화에 따른 반응 AC/A비와 CA/C비 비교)

  • Roh, Byeong-Ho;Yu, Dong-Sik;Son, Jeong-Sik;Kwak, Ho-Weon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.3
    • /
    • pp.341-347
    • /
    • 2015
  • Purpose : This study was to examine a correlation of response AC/A ratio by additional spherical powers with PD(Pupilary distance) and relative accommodation, and was to investigate correlation of CA/C ratio by prism powers. The mean differences between a reciprocal response AC/A ratio and a CA/C ratio were compared, and were suggested to be used as data in the refractive power and prism prescriptions in the clinical. Methods: The open field autorefractometer (Nvision-K 5001, Shin nippon) and Howell target at 40 cm fixation distance to 62 persons with average $22.62{\pm}2.84$ ages were used to measure the response AC/A ratio according to additional Spherical powers. The CA/C ratios were measured using the DOG card at 40cm according to prism powers. Results: When the response accommodation according to Additional Spherical power changes and the response accommodation according to prism power changes were compared, it was larger than the response accommodation according prism power change. These were significant differences statistically. The correlation of response AC/A ratio and PD is showed as r = -0.158, the CA / C ratio is shown as r = 0.093. The correlation of response AC/A ratio and relative accommodation showed as r = -0.253, the CA/C ratio showed as r = 0.566 that is predictable correlation. The correlation of response AC/A ratio and CA/C ratio showed as r = -0.355 that is low minus correlation (p = 0.000). The difference between a reciprocal response AC/A ratio and a CA/C ratio showed $0.12{\pm}0.06D/{\Delta}$ with a significant difference statistically (p=0.000). Conclusions: The correlation of relative accommodation and CA/C ratio showed that depend on the individual, The more a relative accommodation is, the higher a response accommodation of convergence by convergence stimulus is. The reciprocal response AC/A and CA/C ratio showed significant differences statistically. This can have higher CA/C ratio in patients with low AC/A ratio in clinical as an independent variable. Thus when the abnormal binocular vision was prescribed in the clinical, it is necessary to consider the accommodative response even if the AC/A ratio is a normal range.

Analysis of Contrast Medium Dilution Rate for changes in Tube Current and SOD, which are Parameters of Lower Limb Angiography Examination (하지 혈관조영검사 시 매개변수인 관전류와 SOD에 변화에 대한 조영제 희석률 분석)

  • Kong, Chang gi;Han, Jae Bok
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.5
    • /
    • pp.603-612
    • /
    • 2020
  • This study has a purpose to look into the effect of the relationship between the Tube current (mA) and SOD(Source to Object Distance), which is a parameter of lower limb angiography examination, and the dilution rate of the contrast medium concentration (300, 320, 350) on the image. To that end, using 3 mm vessel model water phantom, a vessel model custom made in the size of peripheral vessel diameter, this study measured relationships between change of parameters, such as tube current (mA), SOD and varying concentrations (300, 320, 350) of contrast medium dilution into SNR and CNR values while analyzing the coefficients of variance(cv<10). The software used to measure SNR and CNR values was Image J 1.50i from NIH (National Institutes of Health, USA). MPV (mean pixel value) and SD (standard deviation) were used after verifying numerically the image signal for region of interest (ROI) and background on phantom from the DICOM (digital imaging and communications in medicine) 3.0 file transmitted to PACS. As to contrast medium dilution by the change of tube current, when 146 mA and 102 mA were compared, For both SNR and CNR, the coefficient of variation value was less than 10 until the section of CM: N/S dilution (100% ~ 30% : 70%) but CM: N/S dilution rate (20%: 80% ~ 10% : 90%) the coefficient of variation was 10 or more. As to contrast medium dilution by concentration for SOD change, when SOD's (32.5 cm and 22.5 cm) were compared,For both SNR and CNR, the coefficient of variation value was less than 10 until the section of CM: N/S dilution (100% ~ 30% : 70%) but CM: N/S dilution rate (20%: 80% ~ 10% : 90%) the coefficient of variation was 10 or more. As to contrast medium dilution by concentration for SOD change, when SOD's (32.5 cm and 12.5 cm) were compared,For both SNR and CNR, the coefficient of variation value was less than 10 until the section of CM: N/S dilution (100% ~ 30% : 70%) but CM: N/S dilution rate (20%: 80% ~ 10% : 90%) the coefficient of variation was 10 or more. As a result, set a low tube current value in other tests or procedures including peripheral angiography of the lower extremities in the intervention, and make the table as close as possible to the image receiver, and adjust the contrast agent concentration (300) to CM: N/S dilution (30%: 70%). ) Is suggested as the most efficient way to obtain images with an appropriate concentration while simultaneously reducing the burden on the kidney and the burden on exposure.

A Study on the Collection and Marketing Structure of Sap Water of Acer mono (고로쇠나무 수액(樹液)의 채취(採取)와 유통구조(流通構造)에 관(關)한 연구(硏究))

  • An, Jong Man;Kang, Hag Mo;Kim, Jun Sun
    • Journal of Korean Society of Forest Science
    • /
    • v.87 no.3
    • /
    • pp.391-403
    • /
    • 1998
  • The study was carried out to devise a proper measure to increase the income of mountain villagers by producing sap water of Acer mono, and to make the most of sap water as local specialty to contribute to the local economy of mountain villages. All the processes from collecting to marketing of sap water of Acer mono was investigated. The survey was done from mid-January to mid-February in the 3 major sap water collecting regions, Toji-myon Kurey-gun(Piagol area of Mt. Chiri), Okryong-myon Kwangyang city(Mt. Baekun), and Jookhack-ri Sunchon(Mt. Chokey). A total of 90 householders who collect sap water, to say again, 30 householders in each region, were interviewed personally to make up questionnaires. The habitual or general practices about collecting sap water, the selling price, the sales process, labor power to collect and carry down, carrying distance and facilities, sales income and side income, and family income were investigated and examined. Spots of collecting sap water were not concentrated but scattered all over the collecting area. Collecting method, collecting amount, sales process, and selling price varied with the village and region. Sap water was collected by tapping or boring method, the latter of which was widely used in lots of regions except in Sunchon. Although the amount of sap production per family varied with region, the average amount was about 1,350 liters. Of all the sap water collected, 44% was consumed by drinking of on-the-spot visitors and 36% was sold by order, etc. Sap water was sold at the price varying from 10,000 won to 60,000 won per 18 liters. The average selling price was 41,000 won, but selling prices of 43,000 won and 45,000 wan amounted to 38% and 25%, respectively.

  • PDF

A Study on the RFID's Application Environment and Application Measure for Security (RFID의 보안업무 적용환경과 적용방안에 관한 연구)

  • Chung, Tae-Hwang
    • Korean Security Journal
    • /
    • no.21
    • /
    • pp.155-175
    • /
    • 2009
  • RFID that provide automatic identification by reading a tag attached to material through radio frequency without direct touch has some specification, such as rapid identification, long distance identification and penetration, so it is being used for distribution, transportation and safety by using the frequency of 125KHz, 134KHz, 13.56MHz, 433.92MHz, 900MHz, and 2.45GHz. Also it is one of main part of Ubiquitous that means connecting to net-work any time and any place they want. RFID is expected to be new growth industry worldwide, so Korean government think it as prospective field and promote research project and exhibition business program to linked with industry effectively. RFID could be used for access control of person and vehicle according to section and for personal certify with password. RFID can provide more confident security than magnetic card, so it could be used to prevent forgery of register card, passport and the others. Active RFID could be used for protecting operation service using it's long distance date transmission by application with positioning system. And RFID's identification and tracking function can provide effective visitor management through visitor's register, personal identification, position check and can control visitor's movement in the secure area without their approval. Also RFID can make possible of the efficient management and prevention of loss of carrying equipments and others. RFID could be applied to copying machine to manager and control it's user, copying quantity and It could provide some function such as observation of copy content, access control of user. RFID tag adhered to small storage device prevent carrying out of item using the position tracking function and control carrying-in and carrying-out of material efficiently. magnetic card and smart card have been doing good job in identification and control of person, but RFID can do above functions. RFID is very useful device but we should consider the prevention of privacy during its application.

  • PDF

Evaluating the Visual Contrast Rating of the Landscape Impact Factors - A case study for the Buildings in Natural Landscape - (경관영향 요소별 경관 대비성 평가 - 자연경관에 도입되는 건축물을 중심으로 -)

  • Choi, Won-Bin;Shin, Ji-Hoon
    • Journal of Korean Society of Rural Planning
    • /
    • v.24 no.3
    • /
    • pp.87-96
    • /
    • 2018
  • While cities became bigger and bigger since 1990s, many indiscretely high buildings started to be built in the mountain areas inside a city and in the rural areas in the suburb of each city. To regulate such indiscrete developments, the government prepared for some relevant legal and institutional criteria by having enacted the "Landscape Act" and established a strong management means in the legal and institutional aspects by having introduced the natural landscape deliberation system and the landscape deliberation one into the "Natural Environment Conservation Act." However, since some uniform levels of absolute height and no. of stories are suggested legally and institutionally, it is hard to consider the effects of a real building structure onto the relevant landscape. Accordingly, this thesis is intended to grasp the contrast of the landscape elements in the allowable height section, which is presented through landscape sensitivity. As the results from the visual contrast rating on a small apartment complex located in Dangjin and a large scale of apartment complex in Seosan as the apartment complexes surrounded with natural landscapes that were selected as the subjects of this study, the following conclusion can be finalized. First, there were deducted some factors, that is, forms, lines, colors, textures and sizes as the ones with which can measure and evaluate the contrasting properties when a structure gets into a natural landscape. Second, in case of a small scale of apartment complex (in the foreground) compared to a large one (in the foreground), it was found that the contrasting properties were bigger. In addition, it was also found that the contrasting property of the landscape factor of the foreground compared to that of the middle one becomes bigger depending on a distance. Third, as the results from an evaluation on the contrasting properties of the landscape factor depending on the changes of each floor of a structure, it was found that the factors, that is, forms, lines, colors, textures and sizes are very significant. Among those factors, the factors, forms and lines in a small scale of apartment complex (in the foreground) showed each log regression. But in all of the other cases, they showed each line regression. Fourth, as the results from examining the regression coefficients of the landscape factor, the coefficients of the shapes and lines have similar coefficients and the colors and the textures have similar ones, too. In case of the sizes of apartment complexes, the colors and the textures of a large apartment complex (in the foreground) have similar coefficients, in case of that in the middle ground, the shapes and lines have similar coefficients. Fifth, as the results from estimating the contrasting properties of the landscape factor on the floors within the allowed scope of the landscape sensitivity, it was found that the contrasting property was 3.5 to 4.9 in case of a small scale of apartment complex (in the foreground), but 2.5to 3.7 in case of a small scale of one. In case of a large scale of apartment complex, the value was 3.5 to 5.3, but in case of a large one in the middle ground was 2.9 to 4.9. Sixth, it was comprehended that the contrasting properties of the landscape factor become different depending on each size of apartment complex and the distance of a view point. In this study, it is intended to find the meaning from the aspect that the results can be used as the baseline data for comprehending a proper range of heights of structures objectively during a natural landscape deliberation or a landscape deliberation.

Video Scene Detection using Shot Clustering based on Visual Features (시각적 특징을 기반한 샷 클러스터링을 통한 비디오 씬 탐지 기법)

  • Shin, Dong-Wook;Kim, Tae-Hwan;Choi, Joong-Min
    • Journal of Intelligence and Information Systems
    • /
    • v.18 no.2
    • /
    • pp.47-60
    • /
    • 2012
  • Video data comes in the form of the unstructured and the complex structure. As the importance of efficient management and retrieval for video data increases, studies on the video parsing based on the visual features contained in the video contents are researched to reconstruct video data as the meaningful structure. The early studies on video parsing are focused on splitting video data into shots, but detecting the shot boundary defined with the physical boundary does not cosider the semantic association of video data. Recently, studies on structuralizing video shots having the semantic association to the video scene defined with the semantic boundary by utilizing clustering methods are actively progressed. Previous studies on detecting the video scene try to detect video scenes by utilizing clustering algorithms based on the similarity measure between video shots mainly depended on color features. However, the correct identification of a video shot or scene and the detection of the gradual transitions such as dissolve, fade and wipe are difficult because color features of video data contain a noise and are abruptly changed due to the intervention of an unexpected object. In this paper, to solve these problems, we propose the Scene Detector by using Color histogram, corner Edge and Object color histogram (SDCEO) that clusters similar shots organizing same event based on visual features including the color histogram, the corner edge and the object color histogram to detect video scenes. The SDCEO is worthy of notice in a sense that it uses the edge feature with the color feature, and as a result, it effectively detects the gradual transitions as well as the abrupt transitions. The SDCEO consists of the Shot Bound Identifier and the Video Scene Detector. The Shot Bound Identifier is comprised of the Color Histogram Analysis step and the Corner Edge Analysis step. In the Color Histogram Analysis step, SDCEO uses the color histogram feature to organizing shot boundaries. The color histogram, recording the percentage of each quantized color among all pixels in a frame, are chosen for their good performance, as also reported in other work of content-based image and video analysis. To organize shot boundaries, SDCEO joins associated sequential frames into shot boundaries by measuring the similarity of the color histogram between frames. In the Corner Edge Analysis step, SDCEO identifies the final shot boundaries by using the corner edge feature. SDCEO detect associated shot boundaries comparing the corner edge feature between the last frame of previous shot boundary and the first frame of next shot boundary. In the Key-frame Extraction step, SDCEO compares each frame with all frames and measures the similarity by using histogram euclidean distance, and then select the frame the most similar with all frames contained in same shot boundary as the key-frame. Video Scene Detector clusters associated shots organizing same event by utilizing the hierarchical agglomerative clustering method based on the visual features including the color histogram and the object color histogram. After detecting video scenes, SDCEO organizes final video scene by repetitive clustering until the simiarity distance between shot boundaries less than the threshold h. In this paper, we construct the prototype of SDCEO and experiments are carried out with the baseline data that are manually constructed, and the experimental results that the precision of shot boundary detection is 93.3% and the precision of video scene detection is 83.3% are satisfactory.