• Title/Summary/Keyword: Distance influence

Search Result 1,304, Processing Time 0.025 seconds

The Degree of Market Orientation by Type and Size of Hospital, and Moderating Effect of Environments on Performance (병원의 특성에 따른 시장지향성 분석과 성과에 있어서 환경의 조절 역할)

  • Kim, Pyung-Wung;Yoo, Kyu-Soo;Lee, Yong-Gi
    • Korea Journal of Hospital Management
    • /
    • v.5 no.2
    • /
    • pp.1-21
    • /
    • 2000
  • This study was to examine the degree of market orientated effort by hospital type and size,. and analyzed the moderating effect of environments between market orientation and it's performance. First, there was no significant differences by hospital type, such public hospital, university hospital, and private hospital. However, the orders of market orientation implementation was university hospital. private hospital, and public hospital This finding suggest that university hospital and public hospital, should be market-oriented, or customer-oriented more now, relatively. Second, there were no significant differences in marketing as management policy by hospital types, i.e. public, university or private sector hospitals. However, as to the intensity of the implementation of the market-oriented approach, private hospitals came first, followed by the university hospitals, then the public ones. This finding suggests that university and public hospitals should be more market or customer oriented to compete in the market. Third, only the competitive environment does active moderating roll on hospital performance. The competitive environmental factor forces the organization to be more market oriented. This means the more you are positively situated in the competitive environment, the more you are looking for a market oriented approach. You become more aware of the value of customers and you become more focused on the customer satisfaction and thus become more patient oriented in every facet of decision making. And market oriented hospitals recognize the importance of utilization of high tech medical treatment skills and equipment in patient care. Fourth, according the analysis, market oriented effort gives more influence on hospital performance than the environmental factors. This means that the market oriented effort should become a culture of the hospital which seeks to out distance themselves from its competitors.

  • PDF

The study on Analysis of Influence factors on Items in Apartment House Maintenance Cost (공동주택 관리비 항목별 영향요인 분석 연구)

  • Lim, Nam-gi;Park, Chan-jeong;Jung, Sang-jin
    • Journal of the Korea Institute of Building Construction
    • /
    • v.2 no.1
    • /
    • pp.155-162
    • /
    • 2002
  • In this research, I finally came to a conclusion analyzing the connection among managing of each items in management expenses, the size of each complex and stories, and the term of using. (1) In the managing cost regarding to the management manner, although the managing cost of self-governing management is less imposed than the one of commission management, there is slight difference between those Costs. And it is more important to consider the effectiveness of management than to emphasize reduction of management cost. (2) The higher the stories, the higher the managing cost of elevator per the unit area. It Is caused by the fact that the father the distance of the elevator operating, the higher the electric charges. (3) The third of one of total management cost goes to pay the personnel expenses. So I found that the effective management of the expenses is available to reduce management cost. (4) The higher the stones, the lower the cost of personnel expenses including the cleaner cost. (5) The sum of costs assigned in repairment and management increases in proportion to the term of using. The costs assigned in special repairment and management are interacting to each other. (6) To reduce the management cost, we have to cut down the personnel in security guard that occupies one third of total management cost with application to the joint security system and operation of the self-governing guard. Through this process, it will be easy to accomplish the rationalization of contract with an outside order. Because the improvement of management service is not only the responsibility of owner but also the one of dwellers. And it Is imperative to realize the importance of cooperation and trust between the owner and dwellers. And the establishment of effective managing system which has convenience and rationality must be settled without delay.

The location of midfacial landmarks according to the method of establishing the midsagittal reference plane in three-dimensional computed tomography analysis of facial asymmetry

  • Kim, Min Sun;Lee, Eun Joo;Song, In Ja;Lee, Jae-Seo;Kang, Byung-Cheol;Yoon, Suk-Ja
    • Imaging Science in Dentistry
    • /
    • v.45 no.4
    • /
    • pp.227-232
    • /
    • 2015
  • Purpose: The purpose of this study was to evaluate the influence of methods of establishing the midsagittal reference plane (MRP) on the locations of midfacial landmarks in the three-dimensional computed tomography (CT) analysis of facial asymmetry. Materials and Methods: A total of 24 patients (12 male and 12 female; mean age, 22.5 years; age range, 18.2-29.7 years) with facial asymmetry were included in this study. The MRP was established using two different methods on each patient's CT image. The x-coordinates of four midfacial landmarks (the menton, nasion, upper incisor, and lower incisor) were obtained by measuring the distance and direction of the landmarks from the MRP, and the two methods were compared statistically. The direction of deviation and the severity of asymmetry found using each method were also compared. Results: The x-coordinates of the four anatomic landmarks all showed a statistically significant difference between the two methods of establishing the MRP. For the nasion and lower incisor, six patients (25.0%) showed a change in the direction of deviation. The severity of asymmetry also changed in 16 patients (66.7%). Conclusion: The results of this study suggest that the locations of midfacial landmarks change significantly according to the method used to establish the MRP.

Numerical simulation on gas continuous emission from face during roadway excavation

  • Chen, Liang;Wang, Enyuan;Feng, Junjun;Li, Xuelong;Kong, Xiangguo;Zhang, Zhibo
    • Geomechanics and Engineering
    • /
    • v.10 no.3
    • /
    • pp.297-314
    • /
    • 2016
  • With the mining depth continuously increasing, gas emission behaviors become more and more complex. Gas emission is an important basis for choosing the method of gas drainage, gas controlling. Thus, the accurate prediction of gas emission is of great significance for coal mine. In this work, based on the sources of gas emission from the heading faces and the fluid-solid coupling process, we established a gas continuous dynamic emission model, numerically simulated and applied it to the engineering. The result was roughly consistent with the actual situation and shows the model is correct. We proposed the measures of reducing the excavation distance and borehole gas drainage based on the model. The measures were applied and the result shows the overproof problem of gas emission disappears. The model considered the influence factors of gas emission wholly, and has a wide applicability, promotional value. The research is of great significance for the controlling of gas disaster, gas drainage and pre-warning coal and gas outbursts based on gas emission anomaly at the heading face.

Simulation of the Debris Flow Using FLO-2D According to Curve-shape Changes in Bed Slopes (FLO-2D를 활용한 경사지 형상에 따른 토석류 흐름양상에 대한 수치모의)

  • Jung, Hyo Jun;Yoo, Hyung Ju;Lee, Seung Oh
    • Journal of Korean Society of Disaster and Security
    • /
    • v.13 no.3
    • /
    • pp.45-58
    • /
    • 2020
  • Due to a high portion of mountainous terrains in Korea, debris flow and its disasters have been increased. In addition, recently localized flash-floods caused by climate change should add frequencies and potential risks. Grasping and understanding the behaviors of debris flow would allow us to prevent the consequent disasters caused by its occurrence. In this study, we developed a number of cases by changing the bottom slopes and their curvatures and investigated their effects on potential damage caused by the debris flow using FLO-2D. As simulating each bed slopes we analyzed for velocity, depth, impact, reach distance, and reach shape. As a result the lower the average slope, the greater the influence of its curvature and the numerical results were analyzed with showed a well-marked difference in impact stress and flow velocity. The result from this study could be referred for protecting from the debris flows when design countermeasure structures in mountainous regions.

Study on Curriculum Model for Media Education Expert -Basis on Online University- (미디어 교육 전문가 양성을 위한 교육과정 모델 연구 -온라인 대학을 중심으로-)

  • Lee, Sung-Kyun;Yoon, Young-Doo
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.1
    • /
    • pp.468-476
    • /
    • 2010
  • Since the Media law recently passed, the media's influence has further enhanced than before. However, in reality, systematic media education can't catch up a trend of the fast growing media culture development. The new paradigm is much needed in getting rid of utilizing previous ICT training tool but rather using a creative and critical new role model. This study, media education in schools outside the school, as well as to the proper education of the active and systematic media education system as a way to create a top integrated media that is responsible for training new teachers to offer courses to train professionals. To change fragmentary and unsystematic media education system having been implemented to more professional, systematic and concrete, it is proposed that 3 systematic courses media literacy course, media story telling course and media production course should be implemented.

Effect of KCN Treatment on Cu-Se Secondary Phase of One-step Sputter-deposited CIGS Thin Films Using Quaternary Target

  • Jung, Sung Hee;Choi, Ji Hyun;Chung, Chee Won
    • Current Photovoltaic Research
    • /
    • v.2 no.3
    • /
    • pp.88-94
    • /
    • 2014
  • The structural, optical and electrical properties of sputter-deposited CIGS films were directly influenced by the sputtering process parameters such as substrate temperature, working pressure, RF power and distance between target and substrate. CIGS thin films deposited by using a quaternary target revealed to be Se deficient due to Se low vapor pressure. This Se deficiency affected the overall stoichiometry of the films, causing the films to be Cu-rich. Current tends to pass through the Cu-Se channels which act as the shunting path increasing the film conductivity. The crystal structure of CIGS thin films depends on the substrate orientation due to the influence of surface morphology, grain size and stress of Mo substrate. The excess of Cu was removed from the CIGS films by KCN treatment, achieving a suitable Cu concentration (referred as Cu-poor) for the fabrication of solar cell. Due to high Cu concentrations on the CIGS film surface induced by Cu-Se phases after CIGS film deposition, KCN treatment proved to be necessary for the fabrication of high efficiency solar cells. Also during KCN treatment, dislocation density and lattice parameter decreased as excess Cu was removed, resulting in increase of bandgap and the decrease of conductivity of CIGS films. It was revealed that Cu-Se secondary phase could be removed by KCN wet etching of CIGS films, allowing the fabrication of high efficiency absorber layer.

Effect on Body Balance due to Occlusal Biteplane Splint (교합안정장치가 신체 균형에 미치는 영향)

  • Kim, Jeong-Uk;Park, Min-Chull;Choi, Sung-Min;Lee, Sang-Yeol;Won, Hyeon-Jin
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.4
    • /
    • pp.273-280
    • /
    • 2013
  • This study aims to examine the influences of wearing an occlusal biteplane splint on balance of the body. 10 subjects were selected who had neither impaired occlusion and masticating systems nor difficulty in walking along with no medical history in temporomandibular joint. Measurements were conducted with the Fukuda stepping test, the limits of stability test. The level of significance, ${\alpha}$ to determine the statistical significance was .05. Fukuda stepping test and the limits of stability test were put to the Wilcoxon signed test. As a result of this study, there was a significant difference in the moving distance in the Fukuda stepping test (p<.05). In addition, there were significant differences in the results of the limits of stability test (p<.05). In conclusion, the results of this study suggest that wearing the occlusal biteplane splint has an positive influence on the balance of the boby.

Analytic adherend deformation correction in the new ISO 11003-2 standard: Should it really be applied?

  • Ochsner, A.;Gegner, J.;Gracio, J.
    • Journal of Adhesion and Interface
    • /
    • v.5 no.2
    • /
    • pp.14-26
    • /
    • 2004
  • For reliable determination of mechanical characteristics of adhesively bonded joints used e.g. as input data for computer-aided design of complex components, the thick-adherend tensile-shear test according to ISO 11003-2 is the most important material testing method. Although the total displacement of the joint is measured across the polymer layer directly in the overlap zone in order to minimize the influence of the stepped adherends, the substrate deformation must be taken into account within the framework of the evaluation of the shear modulus and the maximum shear strain, at least when high-strength adhesives are applied. In the standard ISO 11003-2 version of 1993, it was prescribed to perform the substrate deformation correction by means of testing a one-piece reference specimen. The authors, however, pointed to the excessive demands on the measuring accuracy of the extensometers connected with this technique in industrial practice and alternatively proposed a numerical deformation analysis of a dummy specimen. This idea of a mathematical correction was included in the revised ISO 11003-2 version of 2001 but in the simplified form of an analytical method based on Hooke's law of elasticity for small strains. In the present work, it is shown that both calculation techniques yield considerably discordant results. As experimental assessment would require high-precision distance determination (e.g. laser extensometer), finite element analyses of the deformation behavior of the bonded joint are performed in order to estimate the accuracy of the obtained substrate deformation corrections. These simulations reveal that the numerical correction technique based on the finite element deformation modeling of the reference specimen leads to considerably more realistic results.

  • PDF

Assessment of radiopacity of restorative composite resins with various target distances and exposure times and a modified aluminum step wedge

  • Mir, Arash Poorsattar Bejeh;Mir, Morvarid Poorsattar Bejeh
    • Imaging Science in Dentistry
    • /
    • v.42 no.3
    • /
    • pp.163-167
    • /
    • 2012
  • Purpose: ANSI/ADA has established standards for adequate radiopacity. This study was aimed to assess the changes in radiopacity of composite resins according to various tube-target distances and exposure times. Materials and Methods: Five 1-mm thick samples of Filtek P60 and Clearfil composite resins were prepared and exposed with six tube-target distance/exposure time setups (i.e., 40 cm, 0.2 seconds; 30 cm, 0.2 seconds; 30 cm, 0.16 seconds, 30 cm, 0.12 seconds; 15 cm, 0.2 seconds; 15 cm, 0.12 seconds) performing at 70 kVp and 7 mA along with a 12-step aluminum stepwedge (1 mm incremental steps) using a PSP digital sensor. Thereafter, the radiopacities measured with Digora for Windows software 2.5 were converted to absorbencies (i.e., A=-log (1-G/255)), where A is the absorbency and G is the measured gray scale). Furthermore, the linear regression model of aluminum thickness and absorbency was developed and used to convert the radiopacity of dental materials to the equivalent aluminum thickness. In addition, all calculations were compared with those obtained from a modified 3-step stepwedge (i.e., using data for the 2nd, 5th, and 8th steps). Results: The radiopacities of the composite resins differed significantly with various setups (p<0.001) and between the materials (p<0.001). The best predicted model was obtained for the 30 cm 0.2 seconds setup ($R^2$=0.999). Data from the reduced modified stepwedge was remarkable and comparable with the 12-step stepwedge. Conclusion: Within the limits of the present study, our findings support that various setups might influence the radiopacity of dental materials on digital radiographs.