• 제목/요약/키워드: Distance between designs

검색결과 45건 처리시간 0.027초

KTX 의자 설계에 따른 객실 Speech Privacy 평가 (Evaluation of Speech Privacy on the Seat-design in High-speed Train Passenger Cars)

  • 장형석;김재현;전진용
    • 한국소음진동공학회논문집
    • /
    • 제24권2호
    • /
    • pp.146-153
    • /
    • 2014
  • This study investigates the effects of seat-design elements such as seating arrangement, shape, and height on speech privacy in high-speed trains. For the evaluation of speech privacy, acoustic simulation software was used to reproduce room acoustical conditions in passenger cars on the basis of in-situ measurement data. The influences of speech source directivity and source height on privacy distance ($r_P$) were investigated, and it was found that $r_P$ determined using an omni-directional source was relatively shorter than that determined using a directional source. It was also found that $r_P$ decreased when the source height was lower than the height of the seat-back because the seat-back blocked the propagation of speech from the sound source. The effect of seating arrangement was not significant when comparing the vis-a-vis seating and one-side seating arrangements. In addition, among the alternative seat-designs, the seats that block the space between the seats and cover the space near the ear were found to show significantly enhanced speech privacy in high-speed train passenger cars.

Elastic buckling of end-loaded, tapered, cantilevered beams with initial curvature

  • Wilson, James F.;Strong, Daniel J.
    • Structural Engineering and Mechanics
    • /
    • 제5권3호
    • /
    • pp.257-268
    • /
    • 1997
  • The elastic deflections and Euler buckling loads are investigated for a class of tapered and initially curved cantilevered beams subjected to loading at the tip. The beam's width increases linearly and its depth decreases linearly with the distance from the fixed end to the tip. Unloaded, the beam forms a circular are perpendicular to the axis of bending. The beam's deflection responses, obtained by solving the differential equations in closed form, are presented in terms of four nondimensional system parameters: taper ratio ${\kappa}$, initial shape ratio ${\Delta}_0$, end load ratio f, and load angle ${\theta}$. Laboratory measurements of the Euler buckling loads for scale models of tapered initially straight, corrugated beams compared favorably with those computed from the present analysis. The results are applicable to future designs of the end structures of highway guardrails, which can be designed to give the appropriate balance between the capacity to deflect a nearly head-on vehicle back to its right-of-way and the capacity to buckle sufficiently that penetration of the vehicle may be averted.

암 환자의 임상시험 참여 의향과 연관된 요인: 탐색형 서술적 문헌고찰 (Factors associated with willingness to participate in clinical trials for cancer patients: an exploratory narrative review)

  • 김건형;황보연;손경모
    • Journal of Acupuncture Research
    • /
    • 제33권3호
    • /
    • pp.145-152
    • /
    • 2016
  • Objectives : This study aimed to investigate both cancer patients' willingness to participate (WTP) in clinical trials and its associated factors. Methods : We searched MEDLINE (PubMed) for studies that had investigated cancer patients' WTP in clinical trials. Search terms included 'willingness to participate', 'cancer' and 'trial'. Studies published within the last five years up to July 26, 2016 were potentially eligible. Results : Of 44 initial hits, 14 studies (12 quantitative and 2 qualitative) were included. Two out of the 14 studies investigated WTP in an acupuncture trial. Study designs, such as WTP measurement methods, investigation settings, and type of cancer, varied. The proportion of participants with a WTP was widely distributed between the studies (median 48.6 %, range 11.1 % to 88.3 %). Factors associated with WTP included various socio-demographic factors, clinical factors, participants' knowledge/attitudes toward clinical trials, travel distance, information from physicians, and trust toward physicians. Conclusion : WTP and its associated factors were variable across the reviewed studies, which might be due to different research methods and contexts. Whether or not common factors associated with cancer patients' WTP in clinical trials exist remains unclear and thus warrants further research.

무선센서네크워크에서 효율적인 에너지 절약 전송 기법 (A Efficient Energy-Saving Forwarding Technique in Wireless Sensor Networks)

  • ;;손민한;추현승
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2011년도 춘계학술발표대회
    • /
    • pp.158-159
    • /
    • 2011
  • Energy efficiency in wireless sensor networks (WSNs) is one significant factor that needs to be considered when making any designs or doing any enhancements on the communication protocol stack. In WSNs using traditional geographic routing, when a sensor node receives a data packet that needs to be transmitted to the sink, it will forward the packet to the neighbor node which is closest to the sink. The traditional geographic routing assumes that the link quality is always 100%. This may cause a bad result as per which we waste too many energy for retransmissions between the two nodes. Thus, the problem here is how to select such node as forwarder at most efficiently in the aspect of both energy consumption and the distance toward the destination. The better node we choose, the more energy we can conserve for the whole network. In this paper, we propose a next-hop forwarding selection metric, called Energy Consumption for Transmission (ECT), which can resolve the above problem in the best way.

의자의 틸트 기능이 사용자의 생체 신호 및 안락도에 미치는 영향 분석 (Analysis of the Impact of Chair Tilt Function on Users' Biometric Signals and Comfort)

  • 경슬기
    • 대한의용생체공학회:의공학회지
    • /
    • 제45권2호
    • /
    • pp.75-80
    • /
    • 2024
  • This research investigates the influence of chair tilt functionality on biometric signals and user comfort, addressing the ergonomic challenges posed by modern sedentary lifestyles. Through an experimental study involving eight male participants, the impact of chair tilt on electromyography (EMG), heart rate, metabolic rate, pressure distribution, and distance between the lumbar spine and the lumbar support part of the chair was measured across different seating postures. The study utilized chairs with both synchronous and non-synchronous tilt mechanisms to explore how adjustments in chair design affect user comfort and physiological responses during prolonged sitting. Key findings suggest that chair tilt functionality can significantly reduce muscle activity and energy expenditure, enhancing user comfort and potentially mitigating health risks associated with prolonged sedentary behavior. Notably, the study revealed a preference among participants for chairs that aligned the rotational center of the tilt with the hip joint, highlighting the importance of this ergonomic feature in enhancing user comfort. Additionally, the research proposes a novel methodology for assessing seating comfort through the analysis of both biometric and physical signals, providing valuable insights for the development of ergonomic chair designs focused on user health and comfort.

Overdenture 하에서 하악응력 및 의치의 변위에 관한 유한요소법적 분석 (FINITE ELEMENT ANALYSIS OF MANDIBULAR STRESSES AND DENTURE MOVEMENTS INDUCED BY OVERDENTURES)

  • 김정희;정재헌;조규종
    • 대한치과보철학회지
    • /
    • 제28권1호
    • /
    • pp.63-94
    • /
    • 1990
  • The purpose of this study was to analyze the displacement and the magnitude and the mode of distribution of the stresses in the lower overdenture, the mucous membrane, the abutment tooth and the mandibular supporting bone when various denture base materials, such as acrylic resin and 0.5mm metal base, and various denture base designs were subjected to different loading schemes. For this study, the two-dimensional finite element method was used. Mandibular arch models, with only canine remaining, were fabricated. In the first denture base design, a space, approximately 1mm thick, was prepared between the denture and the dome abutment. In the second denture base design, contact between the denture and the dome abutment was eliminated except the contact of the occlusal third of the abutment. In order to represent the same physiological condition as the fixed areas of the mandible under loading schemes, the eight nodes which lie at the mandibular angle region, the coronoid process and the mandibular condyle were assumed to be fixed. Each model was loaded with a magnitude of 10 kgs on the first molar region(P1) and 7 kgs on the central incisal region (P2) in a vertical direction. Then the force of 10 kgs was applied distributively from the first premolar to the second molar of each model in a vertical direction(P3). The results were as follows. : 1. When the testing vertical loads were given to the selected points of the overdenture, the overdenture showed the rotatory phenomenon, as well as sinking and the displacements of alveolar ridge, abutment and lower border of mandible under the metal base overdenture were less than those under the acrylic resin overdenture. 2. The maximum principal stresses(the maximum tensile stresses) being considered, high tensile stresses occured at the buccal shelf area, the posterior region of the ridge crest and the anterior border region of the mandibular ramus. 3. The minimum principal stresses(the maximum compressive stresses) being considered, high compressive stresses occured at the inferior and posterior border region of the mandible, the mandibular angle and the posterior border region of the mandibular ramus. 4. The vertical load on the central incisal region(P2) produced higher equivalent stress in the mandible than that on any other region(P1, P3) because of the long lever arm distance from the fixed points to the loading point. 5. Higher equivalent stresses were distributed throughout the metal base overdenture than the resin base overdenture under the same loading condition. 6. The case of occlusal third contact of the abutment to the denture produced higher equivalent stresses in the abutment, the mandibular area around the abutment and the overdenture than the case of a 1mm space between the denture and the abutment. 7. Without regard to overdenture base materials and designs, the amounts and distribution patterns of equivalent stresses under the same loading condition were similar in the mucous membrane.

  • PDF

임플랜트 Overdenture의 Bar설계에 따른 하악지지조직의 광탄성학적 응력분석 (PHOTOELASTIC STRESS ANALYSIS ON THE MANDIBLE CAUSED BY IMPLANT OVERDENTURE)

  • 강정민;방몽숙
    • 대한치과보철학회지
    • /
    • 제32권2호
    • /
    • pp.327-353
    • /
    • 1994
  • This study was performed to evaluate the effects of number and alignment of implant fixture and various bar designs on the retention of denture and the stress distribution. Six kinds of photoelastic mandibular models and nine kinds of overdenture specimens were designed. A unilateral vertical load was gradually applied on the right first molar to calculate the maximal dislodgement load of each specimen. A unilateral vertical load of 17 Kgf was applied on the right first molar and a vertical load of 10 Kgf was applied on the interincisal edge region. The stress pattern which developed in each photoelastic model was analyzed by the reflection polariscope. The results obtained were as follows: 1. The maximal dislodgement load reversely increased with the distance from the loading point to the implant fixture, while it linearly increased with that from the most posterior implant fixture to the mesial clip. The maximal dislodgement load also increased with the use of a cantilever bar. 2. Under the posterior vertical load, the stress to the supporting tissue of the denture base increased with the distance from the loading point to the implant future. The stress concentration on the apical area of the implant future reversely increased with the distance from the loading point to the implant future. 3. In the overdentures supported by two implant fixtures under the posterior vertical load. the specimen implanted on lateral incisor areas with a cantilever bar exhibited more favorable stress distribution than that without a cantilever bar. The specimen implanted on the canine areas without a cantilever bar, however, exhibited more favorable stress distribution. 4. In the overdentures supported by three implant fixtures. the specimen implanted ell the midline and canine areas exhibited more favorable stress distribution than that implanted oil the midline and the first premolar areas. 5. In the overdentures supported by four implant fixtures. the specimen implanted with two adjacent implant fixtures exhibited more favorable stress distribution than that implanted at equal distance under the posterior vertical load. 6. Under the anterior vertical load, the overdentures supported by three implant fixtures exhibited stress concentration on the supporting structure of the middle implant future. In overdentures supported by two or four implant futures, no significant difference was noted in stress distribution between the types of bars. These results indicate that the greater the number of implant fixtures, the better the stress distribution is. A favorable stress distribution may be obtained in the overdentures supported by two or three implant fixtures, if the location and the design of the bar are appropriate.

  • PDF

아말감 와동의 파절에 관한 3차원 유한요소법적 연구 (A STUDY ON AMALGAM CAVITY FRACTURE WITH THREE DIMENSIONAL FINITE ELEMENT METHOD)

  • 김한욱;엄정문;이정식
    • Restorative Dentistry and Endodontics
    • /
    • 제19권2호
    • /
    • pp.345-371
    • /
    • 1994
  • Restorative procedures can lead to weakening tooth due to reduction and alteraton of tooth structure. It is essential to prevent fractures to conserve tooth. Among the several parameters in cavity designs, cavity isthmus and depth are very important. In this study, MO amalgam cavity was prepared on maxillary first premolar. Three dimensional. finite element models were made by serial photographic method and cavity depth(1.7mm, 2.4mm) and isthmus (11 4, 1/3, 1/2 of intercuspal distance) were varied. linear, eight and six-nodal, isoparametric brick elements were used for the three dimensional finite element model. The periodontal ligament and alveolar bone surrounding the tooth were excluded in these models. Three types model(B, G and R model) were developed. B model was assumed perfect bonding between the restoration and cavity wall. Both compressive and tensile forces were distributed directly to the adjacent regions. G model(Gap Distance: 0.000001mm) was assumed the possibility of play at the interface simulated the lack of real bonding between the amalgam and cavity wall (enamel and dentin). When compression occurred along the interface, the forces were transferred to the adjacent regions. However, tensile forces perpendicular to the interface were excluded. R model was assumed non-connection between the restoration and cavity wall. No force was transferred to the adjacent regions. A load of 500N was applied vertically at the first node from the lingual slope of the buccal cusp tip. This study analysed the displacement, von Mises stress, 1 and 2 direction normal stress and strain with FEM software ABAQUS Version 5.2 and hardware IRIS 4D/310 VGX Work-station. The results were as follows: 1. G model showed stress and strain patterns between Band R model. 2. B model and G model showed the bending phenomenon in the displacement. 3. R model showed the greatest amount of the displacement of the buccal cusp followed by G and B model in descending order. G model showed the greatest amount of the displacement of the lingual cusp followed by B and R model in descending order. 4. B model showed no change of the displacement as increasing depth and width of the cavity. G and R model showed greater displacement of the buccal cusp as increasing depth and width of the cavity, but no change in the displacement of the lingual cusp. 5. As increasing of the width of the cavity, stress and strain were not changed in B model. Stress and strain were increased on the distal marginal ridge and buccopulpal line angle in G and R model. The possibility of the tooth fracture was increased. 6. As increasing of the depth of the cavity, stress and strain were not changed in B and G model. Stress and strain were increased on the distal marginal ridge and buccopulpal line angle in R model. The possibility of the tooth fracture was increased.

  • PDF

CAD/CAM 세라믹 인레이로 수복한 치아의 응력분포에 관한 유한요소법적 연구 (FINITE ELEMENT STRESS ANALYSIS OF A TOOTH RESTORED WITH CAD/CAM CERAMIC INLAY)

  • 송보경;엄정문
    • Restorative Dentistry and Endodontics
    • /
    • 제26권6호
    • /
    • pp.464-484
    • /
    • 2001
  • When restoring a tooth, the dentist tries to choose the ideal material for existing situation. One criterion that is considered is its suitability for restoring coronal strength. As more tooth structure is removed, the cusps are weakened and susceptible to fracture. Further, this increased deformation may cause the formation of intermittent gaps at the margin between the hard tissue and the restoration, facilitating marginal leakage. The improvements in ceramic materials now make it possible for alternatives to amalgams, composites, and cast metal to be of offered for posterior teeth. Of the materials used, ceramics most closely approximates the properties of enamel. The introduction of computer-aided design/computer-aided manufacture(CAD/CAM) systems to restorative dentistry represents a major technological breakthrough. It is possible to design and fabricate ceramic restorations at a single appointment. Additionally, CAD/CAM systems eliminate certain errors and inaccuracies that are inherent to the indirect method and provide an esthetic restoration. The aim of this investigation was to study the loading characteristics of CAD/CAM ceramic inlay and to compare the stress distribution and displacement associated with different designs of cavity(the isthmus width and cavity depth). A human maxillary left first premolar was prepared with standard mesio-occlusal cavity preparation, as recommended by the manufacturer Ceramic inlay was fabricated with CEREC 2 CAD/CIM equipment and cemented into the prepared cavity. Three dimensional model was made by the serial photographic method. The cavity width was varied $\frac{1}{3}$, $\frac{1}{2}$ and $\frac{2}{3}$ of intercuspal distance between buccal and lingual cusp tip. The cavity depth was varied 1.5mm and 2.3mm. So six models were constructed to simulate six conditions. A point load of 500N was applied vertically onto the first node of the lingual slope from the buccal cusp tip. The stress distribution and displacement were solved using ANSYS finite element program(Swanson Analysis System). (omitted)

  • PDF

Utilizing Usability Metrics to Evaluate a Subway Map Design

  • Jung, Kwang Tae
    • 대한인간공학회지
    • /
    • 제36권4호
    • /
    • pp.343-353
    • /
    • 2017
  • Objective: This study aims to evaluate the efficiency of two representative subway map design types, namely a diagram type and a geographical type using physiological metrics, performance metrics, and self-reported metrics, which are representative usability metrics. Background: Subway maps need to be designed in order for users to quickly search and recognize subway line information. Although most cities' subway maps currently use the diagram type designed by Henry Beck, New York City's subway map has recently been changed to the subway map type combined with the geographical type designed by Michael Hertz. However, not many studies on its efficiency are found, and the studies that are available mainly depend on questionnaire surveys or take on a subjective behavioral study type based on experts' experiences. In this regard, evaluation through a more objective method is needed. Method: This study employed usability metrics as a method to evaluate the efficiency of information search targeting the diagram type and geographical type subway maps used mostly as subway maps. To this end, physiological metrics obtained through eye tracking, task completion time, representative metric of task performance, and subjective evaluation metrics were used for the suitability evaluation of subway map designs. Results: In the result of gaze movement distance analysis, no significant difference was shown in the two design types in terms of a process finding a departure station from the starting point and a process finding a transfer station between the departure station and arrival station (destination). However, the gaze movement distance in the process finding the arrival station at the departure station was significantly shorter in the geographical type, rather than in the diagram type. The analysis of task completion time showed a result similar to the gaze movement distance analysis result. Task completion time was significantly shorter in the geographical type, rather than in the diagram type, which is in the process finding the arrival station at the departure station. In other information search processes, no significant difference was shown. As a result of subjective evaluation metrics analysis, no significant difference was revealed in the two design types. Conclusion: An analysis on the two representative subway map design types was carried out via the adoption of usability metrics. As a result, although no significant difference was shown in some information search processes, it was revealed that information search was easier in the geographical type overall. Also, it was found that usability metrics can be effectively used to evaluate the design types of subway maps. Application: The study results can be used to set design direction to offer ease in information search on subway lines. The study also can be used as a method to evaluate a subway map's design type.