• Title/Summary/Keyword: Distance Measuring Sensor

Search Result 169, Processing Time 0.022 seconds

Measurement of Basis Signal with HFCT for Diagnosing Partial Discharge in Middle Joint Box of 154kV Grade (154kV급 중간접속부내의 부분방전 진단을 위한 HFCT 적용 기준신호 측정연구)

  • Lee, Yong-Sung;Kim, Jung-Yoon;Lee, Kyung-Yong;Choi, Yong-Sung;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2005.11a
    • /
    • pp.217-219
    • /
    • 2005
  • To detect partial discharge of 154kV joint box, we have made experiment by using the HFCT sensor. Generally the signals which are detected in partial discharge test of underground power transmission cable are accompanied with both noises of high voltage and noises of surrounding power cable. The most noise in near to end part of joint box is corona, beside other noises flowed from surrounding area. Partial discharge test is difficulty due to these noises. First, we test reliability on both injection of calibration signal in NJB and removal of low frequency. After that, we had analyzed frequencies by measuring signals in IJB with 300[m] distance from NJB. Also we had measured S/N ratio by using the indirected injection method of calibration signal in IJB. In this experiment, two measurement methods were difference of detection acquisition, but these had the equal frequency properties.

  • PDF

Dynamic and static structural displacement measurement using backscattering DC coupled radar

  • Guan, Shanyue;Rice, Jennifer A.;Li, Changzhi;Li, Yiran;Wang, Guochao
    • Smart Structures and Systems
    • /
    • v.16 no.3
    • /
    • pp.521-535
    • /
    • 2015
  • Vibration-based monitoring is one approach used to perform structural condition assessment. By measuring structural response, such as displacement, dynamic characteristics of a structure may be estimated. Often, the primary dynamic responses in civil structures are below 5 Hz, making accurate low frequency measurement critical for successful dynamic characterization. In addition, static deflection measurements are useful for structural capacity and load rating assessments. This paper presents a DC coupled continuous wave radar to accurately detect both dynamic and static displacement. This low-cost radar sensor provides displacement measurements within a compact, wireless unit appropriate for a range of structural monitoring applications. The hardware components and operating mechanism of the radar are introduced and a series of laboratory experiments are presented to assess the performance characteristics of the radar. The laboratory and field experiments investigate the effect of factors such as target distance, motion amplitude, and motion frequency on the radar's measurement accuracy. The results demonstrate that the radar is capable of both static and dynamic displacement measurements with sub-millimeter accuracy, making it a promising technology for structural health monitoring.

Measurement of Basis Signal with HFCT for Diagnosing Partial Discharge in Middle Joint Box of 154kV Grade (154kV급 중간접속부내의 부분방전 진단을 위한 HFCT 적용 기준신호 측정)

  • Ahn, Jong-Hyun;Yun, Ju-Ho;Choi, Yong-Sung;Park, Dae-Hee;Lee, Kyung-Sup
    • Proceedings of the KIEE Conference
    • /
    • 2007.04b
    • /
    • pp.75-78
    • /
    • 2007
  • To detect partial discharge of 154kV joint box, we have made experiment by using the HFCT sensor. Generally the signals which are detected in partial discharge test of underground power transmission cable are accompanied with both noises of high voltage and noises of surrounding power cable. The most noise in near to end part of joint box is corona, beside other noises flowed from surrounding area. Partial discharge test is difficulty due to these noises. First, we test reliability on both injection of calibration signal in NJB and removal of low frequency. After that, we had analyzed frequencies by measuring signals in IJB with 300[m] distance from NJB. Also we had measured S/N ratio by using the indirected injection method of calibration signal in IJB. In this experiment, two measurement methods were difference of detection acquisition, but these had the equal frequency properties.

  • PDF

Tightness Evaluation of Smart Sportswear Using 3D Virtual Clothing (3D 가상착의를 이용한 스마트 스포츠웨어의 밀착성 평가)

  • Soyoung Kim;Heeran Lee
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.47 no.1
    • /
    • pp.123-136
    • /
    • 2023
  • To develop smart sportswear capable of measuring biometric data, we created a close-fitting pattern using two- and three-dimensional (2D and 3D, respectively) methods. After 3D virtual fitting, the tightness of each pattern was evaluated using image processing of contact points, mesh deviation, and cross-sectional shapes. In contact-point analysis, the 3D pattern showed high rates of contact with the body (84.6% and 93.1% for shirts and pants, respectively). Compared with the 2D pattern, the 3D pattern demonstrated closer contact at the lower chest, upper arm, and thigh regions, where electrocardiography and electromyography were primarily carried out. The overall average gap was also lower in the 3D pattern (5.27 and 4.66 mm in shirts and pants, respectively). In the underbust, waist, thigh circumference, and mid-thigh circumference, the cross-section distance between clothing and body was showed a statistically significant difference and evenly distributed in the 3D pattern, exhibiting more closeness. The tightness and fit of the 3D smart sportswear sensor pattern were successfully evaluated. We believe that this study is critical, as it facilitates the comparison of different patterns through visualization and digitization through 3D virtual fitting.

The UV LED Bar Optimal Design with Human Detection and Control Function (인체 감지 제어 기능을 갖는 UV LED Bar의 최적 설계)

  • Kim, Chang-Sun;Lee, Jae-Hak;Goh, Young-Jin
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.12 no.6
    • /
    • pp.1219-1226
    • /
    • 2017
  • In this paper, it is performed the optimal design of the UV LED bar which can be used variously. The UV LED Bar emits ultraviolet rays, so it is important to emit ultraviolet rays constantly for the purpose of use. In order to emit a certain amount of ultraviolet rays as ever, the ultraviolet ray emission should be driven by a constant current source within the operable input voltage range. And also the heat dissipation is particularly important because of the long ultraviolet emission retention time due to the UV utilization characteristics. In addition, since human body protection is essential, the algorithm is configured to operate according to human body detection using distance sensor and Bluetooth. Three 365nm UV LEDs were used in series to emit ultraviolet UVA, operating at the constant current of 500mA with an efficiency of 87.5% and a power consumption of 6.006W. The ultraviolet radiation dose was measured at $5.35mW/cm^2$ at the distance of 10 cm when measured by the Lutron ultraviolet measuring instruments.

Application of Eddy Current Sensor for Measurement of TBM Disc Cutter Wear (TBM 디스크커터의 마모량 측정을 위한 와전류센서의 적용 연구)

  • Min-Sung Park;Min-Seok Ju;Jung-Joo Kim;Hoyoung Jeong
    • Tunnel and Underground Space
    • /
    • v.33 no.6
    • /
    • pp.534-546
    • /
    • 2023
  • If the disc cutter is excessively worn or damaged, it becomes incapable of rotating and efficiently cutting rockmass. Therefore, it is important to appropriately manage the replacement cycle of the disc cutter based on its degree of wear. In general, the replacement cycle is determined based on the results of manual inspection. However, the manual measurements has issues related to worker safety and may lead to inaccurate measurement results. For these reasons, some foreign countries are developing the real-time measurement system of disc cutter wear by using different sensors. The ultrasonic sensors, eddy current sensors, magnetic sensors, and others are utilized for measuring the wear amount of disc cutters. In this study, the applicability of eddy current sensors for real-time measurement of wear amount in TBM disc cutters was evaluated. The distance measurement accuracy of the eddy current sensor was assessed through laboratory tests. In particular, the accuracy of eddy-current sensor was evaluated in various environmental conditions within the cutterhead chamber. In addition, the measurement accuracy of the eddy current sensor was validated using a 17-inch disc cutter.

Development of a Low Frequency Accelerometer using the Fiber Bragg Grating Sensor (Fiber Bragg Grating 센서를 이용한 저진동 가속도계 개발)

  • Pack, In-Seok;Kang, Han-Bin;Lee, Kye-Kwang;Lee, Seok-Soon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.29 no.10
    • /
    • pp.1101-1109
    • /
    • 2012
  • Accelerometers play a key role in the structural assessment. However, the current electric type accelerometers have certain limitations to apply some structures such as heavy cabling labor, installed sea structure and sensitivity to electromagnetic fields. An optical Fiber Bragg Grating (FBG) accelerometer has many advantages over conventional electrical sensors since their immunity to electromagnetic interference and their capability to transmit signals over long distance without any additional amplifiers, and there is no corrosion from sea water. In this paper, we have developed a new FBG-based accelerometer. The accelerometer consists of two cantilevered type beams and a mass and two rollers. A bragg grating element is not directly glued to a cantilever to avoid possible non-uniform strain in the element. Instead, the bragg grating element will be attached to rotation part that rolled inducing vertical movement of the mass and support cantilever beams so that the bragg grating element is uniformly tensioned to achieve a constant strain distribution. After manufacturing, we will prove the performance and the natural frequency of the accelerometer through the experiment with a vibration shaker. The FBG-based accelerometer is developed for measuring the vibration not exceeding 50 Hz for the marine and civil structures.

Analysis of Frequency Response Characteristics in Optical Microphone (광 마이크로폰의 주파수 응답특성 분석)

  • Yeom, Keong-Tae;Kim, Kwan-Kyu;Heh, Do-Geun;Kim, Yong-Kab
    • The Journal of the Korea Contents Association
    • /
    • v.8 no.6
    • /
    • pp.8-15
    • /
    • 2008
  • In this paper, in order to analyze property of frequency response in optical microphone, system was implemented. The capacitance microphone and fiber-optic transmission path type fiber-optic microphone (FOM) have weaknesses in directivity, size, weight, and price. However suggested optical microphone can be constituted by cheap devices, so it has many benefits like small size, light weight, high directivity, etc. Head part of optical microphone which is suggested in this paper is movable back and forth by sound pressure with the attached reflection plate. Operating point is determined by measuring the respond characteristics and choosing the point on which has maximum linearity and sensitivity while changing the distance between optical head and vibrating plate. We measured the output of the O/E transformed signal of the optical microphone while frequency of sound signal is changed using sound measurement/analysis program, Smaart Live and USBPre, which are based on PC, and compared the result from an existing capacitance microphone. The measured Optical microphone showed almost similar output characteristics as those of the compared condenser microphone, and its bandwidth performance was about 300[Hz]-3[kHz] at up to 3 [dB].

EA Study on Practical Engineering Education through the Design and Configure of Safe Running Type Drones (안전 주행형 무인기의 설계 및 제작을 통한 실천 공학 교육에 관한 연구)

  • Jo, Yeong-Myeong;Lee, Sang-Gwon;Chang, Eun-Young
    • Journal of Practical Engineering Education
    • /
    • v.9 no.1
    • /
    • pp.7-13
    • /
    • 2017
  • This study will provide a practical plan of engineering education through the study of major activities connected with the production of works to accomplish the graduation conditions by completing the comprehensive design subject and the result of the performance. The designed subject is to measure the minimum safety distance during driving using the obstacle detection function of the ultrasonic sensor and to perform the avoidance algorithm based on the measurement value of the acceleration gyro sensor. It is proposed an access surveillance system that minimizes the damage of drones, surrounding objects, and people, and improves air mobility. Experimental results show that the obstacles around the drone are detected by five ultrasonic sensors and the difference of output value is applied to each motor of the drone and obstacle avoidance is confirmed. In addition, the content and level of the data for measuring the achievement of learning achievement in the engineering education certification program were used and the results were confirmed to be consistent with the description of the engineering problem level required for the graduates of 4-year engineering college.

Reliability Assessment of Ambient Noise HVSR per Observation Condition (관측 환경에 따른 상시미동의 HVSR 결과 신뢰도 평가)

  • Yoo, Byeongho;Choi, Woojeong;Choi, Inhyeok;Kwak, Dongyoup
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.42 no.1
    • /
    • pp.23-33
    • /
    • 2022
  • The horizontal-to-vertical spectral ratio (HVSR) of ambient noise is widely used to identify the resonant frequency of a site. The frequency at the largest HVSR is regarded as the resonant frequency. The source of ambient noise is impossible to identify and control. Therefore, obtaining reliable HVSR of ambient noise requires sufficient measurement time and absence of near-field vibration. In this study, we investigated the minimum stabilization time required for a portable seismometer and the effect of the distance between the seismometer and artificial vibration on HVSR estimation. In the case of a soil site, the HVSR was stabilized after 5 minutes after sensor installation. In the case of a rock site, stabilization required more than an hour. Human-footsteps within 10 m of the seismometer strongly influenced the HVSR for the soil site. These results provide a field guideline when measuring ambient noise for HVSR.