• Title/Summary/Keyword: Distance AC/A

Search Result 185, Processing Time 0.028 seconds

THE TRANSFER OF CHLORIDE ION ACROSS ANION EXCHANGE MEMBRANE

  • Yu, Zemu;Wang, Hanming;Wang, Erkang
    • Analytical Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.597-601
    • /
    • 1995
  • The transfer of chloride ion across an anion exchange membrane (AEM) was investigated by cyclic voltammetry (CV) and electrochemical impedance spectra. In CV experiment, when the size of the hole in membrane was much smaller than the distance between membrane holes, the Cl anion transfer showed steady state voltammetric behavior. Each hole in membrane can be regarded as a microelectrode and the membrane was equivalent to a microelectrode array in this condition. When the hole in membrane was large or the distance between membrane holes was small, the CV curve of the Cl anion transfer across membrane showed peak shape, which attributed to linear diffusion. In ac impedance measurement, the impedance spectrum of the membrane system was composed of two semicircles at low de bias, corresponding to the bulk characteristics of the membrane and the kinetic process of ion transfer, respectively. The bulk membrane resistance increases with increasing dc bias and only one semicircle was observed at higher dc bias. The parameters related to kinetic and membrane properties were discussed.

  • PDF

Investigation of the Experiment for Separation Distance between Powerline Earth and Pipelines (전력선 접지와 매설배관의 이격거리 실증실험 사례 조사)

  • Lee, H.G.;Ha, T.H.;Ha, Y.C.;Bae, J.H.;Kim, D.K.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07e
    • /
    • pp.87-88
    • /
    • 2006
  • There are a number of reported instances of actual pipeline rupture during power line faults caused by melting of the pipe wall. This type of hazard was considered to be among the most serious of AC effects on pipelines in an international survey, comparable to the personnel safety hazard. Moreover, resistance coupling is not only a risk when the pipeline parallels a power line but also when they cross. One method of minimizing the effects of resistive coupling is by maintaining an appropriate separation distance between the pipeline and tower. This paper investigate the experiment for separation distance between the powerline earth and pipelines.

  • PDF

Effect of AC electric fields on Free Jet Flow in a Laminar (층류 자유제트유동에 인가된 교류전기장의 영향)

  • Kim, Gyeong Taek;Lee, Won June;Cha, Min Suk;Park, Jeong;Chung, Suk Ho;Kwon, Oh Boong;Kim, Min Kuk;Lee, Sang Min;Yun, Jin Han;Keel, Sang In
    • 한국연소학회:학술대회논문집
    • /
    • 2015.12a
    • /
    • pp.79-81
    • /
    • 2015
  • The experimental study on gasesous laminar free-jet flow was investigated by applying high voltage alternating current (AC) to the nozzle. The jet flows were affedcted significatly by AC electric fields particularly at high voltages for applied frequencies less than 80 Hz, while those were not responded to further increased frequencies. Under certain AC conditions of applied voltgae and frequency, the laminar gaseous fuel stem was broken down at an axial distance and subsequently separtaed into some parts. The velocity fields in jet flows interactiong with applied electric fields were compared with those without having electric field. Interaction of applying electric fields with laminar free jet flow was discussed in detail, and the possible mechanism was also explained.

  • PDF

A Study for Fault Location Scheme Using the 9-Conductor Modeling of Korean Electric Railway System (9도체 전기철도 모델링을 이용한 고장점 표정 방안 연구)

  • Lee, Han-Sang;Lee, Chang-Mu;Lee, Han-Min;Jang, Gil-Soo;Chang, Sang-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 2006.11a
    • /
    • pp.411-413
    • /
    • 2006
  • This paper presents a novel fault location scheme on Korean AC electric railway systems. On AC railway system, because there is a long distance, 40 km or longer, between two railway substations, a fault location technique is very important. Since the fault current flows through the catenary system, the catenary system must be modeled exactly to analyze fault current magnitude and fault location. In this paper, before suggestion for the novel scheme of fault location, a 9-conductor modeling technique that includes boost wires and impedance bonds is introduced, based on the characteristics of Korean AC electric railway. After obtaining a 9-conductor modeling, the railway system is constructed for computer simulation by using PSCAD/EMTDC. By case studies, we can verify superiority of a new fault location scheme and suggest a powerful model for fault analysis on electric railway systems.

  • PDF

Study on Dual-Lenses Actuator for HD-DVD System (차세대 DVD 시스템용 Actuator 연구)

  • Kim, Seok-Jung;Lee, Yong-Hoon;Ahn, Young-Man;Chung, Chong-Sam
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.777-781
    • /
    • 2002
  • Recently, an optical disc system has been proposed using blue laser diode, high NA objective lens and groove only disc structure. A new method is needed to readout CD and DVD in this blue system. In order to readout CD and DVD in HD-DVD system, we adopted dual-lenses actuator in consideration of optical utilization efficiency, optical performance and insurance of sufficient W.D (working distance). This dual-lenses actuator has two objectives in radial direction, one is for CD/DVD and the other is for HD-DVD. We had to solve the induced problems of DC tilt increase, $2^{nd}$ resonance deterioration and AC sensitivity drop caused by disposing two lenses in an actuator. Especially, to solve AC sensitivity drop, we introduced two 2-pole magnets and separated focus and track magnetic circuits. Consequently we presented that dual-lenses actuator has been possessed good performance. And we measured eye patterns of CD, DVD and HD-DVD by using HD-DVD optical pick-up with dual-lenses actuator.

  • PDF

Development of an Urea Sensor using Electric Conductivity Method (전기전도도법을 이용한 우레아 농도 센서 개발)

  • Choi, B.C.;Kim, K.Y.;Yang, J.Y.;Kim, H.N.
    • Journal of Power System Engineering
    • /
    • v.15 no.2
    • /
    • pp.55-60
    • /
    • 2011
  • The popularity of diesel engines is derived primarily from their higher thermal efficiency resulting from higher compression ratio. NOx removal from the diesel emissions is very important to meet stringent emission regulations. NOx emission from diesel engines is removed by an urea-SCR or an LNT system. The urea-SCR system needs the urea-solution supply system with concentration and level sensor. This study was carried out to develop a sensor for the measurement of urea-solution concentration by an electric conductivity method. Considering experimental parameters were the material of electrode, two kinds of electric power(AC or DC), the distance between two electrodes, and the length of electrode. It was found that the AC electric power was more useful to measure the urea-solution concentration compared to DC, because it prevented an ionization of the urea-solution. The silver rod coated with Pt is the most useful electrode, tendency of which is similar to Pt rod, and the cost is more economic. We could also find out the optimum distance between two electrodes and the length of electrode was 10mm and 3mm, respectively.

Development of Twin-Objective Actuator with Radial Tilt Function for Blu-Ray Disc Recorder (BD Recorder용 3축 독립구동 Twin-Objective 액추에이터 개발)

  • Kim, Seok-Jung;Heor, Tae-Youn;Kim, Tae-Kyung;Ahn, Young-Man;Chung, Chong-Sam;Park, Soo-Han
    • Transactions of the Society of Information Storage Systems
    • /
    • v.1 no.2
    • /
    • pp.121-126
    • /
    • 2005
  • Recently, an optical disc system has been proposed using blue laser diode, high NA objective lens and groove only disc structure. A new method is needed to readout CD and DVD in this Blu-Ray Disc Recorder. In order to readout CD and DVD in Blu-Ray Disc Recorder, we adopted dual-lenses actuator in consideration of optical utilization efficiency, optical performance and insurance of sufficient W.D(working distance). This dual-lenses actuator has two objectives in radial direction, one is for CD/DVD and the other is for BD. We had to solve the induced problems of collision between disc and lens, DC tilt increase, AC tilt increase, 2nd resonance deterioration and AC sensitivity drop caused by disposing two lenses in an actuator. Also we developed high response twin- objective actuator with radial tilt function to apply high-speed BD Recorder or BD Player. Consequently we presented that two kinds of dual-lenses actuators for BD Recorder have been possessed good performance in 3 axis directions. And we measured eye patterns of CD, DVD and BD by using one BD optical pick-up with dual-lenses actuator.

  • PDF

A Study on the Reliability Analysis in LVDC Distribution System Considering Layout (저압직류 배전계통의 구성 형태를 고려한 공급신뢰도 분석에 관한 연구)

  • Kim, Chung-Mo;No, Chul-Ho;Han, Joon;Oh, Yun-Sik;Kim, Hyun-Soo;Baek, In-Ho;Kim, Chul-Hwan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.2
    • /
    • pp.75-81
    • /
    • 2015
  • At the end of the 19th century, Edison's DC power system and Tesla's AC power system was debated in power market. Finally, AC system became the primary system of the power market because both step-up and step-down of voltage by using transformer and long-distance power transmission are easily possible. However, nowadays the power market takes some action for introducing DC system. Both domestic and foreign researchers are conducting the study on the DC system as well. Some researchers have conducted the studies on power quality and economic evaluation of the DC distribution system but DC distribution system is still controversial in terms of the effectiveness and reliability. In this paper, we calculate the reliability indices of the Low Voltage Direct Current(LVDC) distribution system considering arrangement of power electronics, layout of the distribution system, and distance between load points.

Change analysis with A.C of D.C electric railway (직류 전기철도의 교류화 분석)

  • Kim, Youn-Sik;Lee, Gi-Seung;Sim, Jae-Suk
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.151-156
    • /
    • 2008
  • The after 1974 capital region electric railroad is opened to traffic Koraill and Seoul metro adopt each other different power supply method and they operate and they are come. AC 25[kv] method voltage the insulation becomes larger standing distance highly, the case tunnel section which will introduce in the underground segment becomes on a large scale and the cost of construction increases to the city center and the underground segment adoption of DC method was many. To recent times with R-bar (Rigid-bar) introductions change of tunnel section the introduction of AC method came to be easy without in the underground segment. Operates sees in the electric protection where the Seoul metro and the Korail are different each other and, from the dead section segment the interior electric light to put out lights the passenger brings about inconveniently and the civil appeal which demands a power supply method unification occurs, within the company interchange electric railroad brazier safety improvement and maintenance expense curtailment etc. the flaw is original proposal, is a condition which finishes a feasibility study service about the power supply method fringe land. Interchange analysis of the DC electric railway it leads from the present paper and it compares under analyzing being it could be reflected to also the route which is in the process of actual using boil the strong point and a weak point of DC and AC method of the establishment route constructive at the time of and

  • PDF

Compensation of Instantaneous Voltage Drop at AC Railroad System with Single-Phase Distributed STATCOM (전기철도 급전시스템의 순시전압강하 보상을 위한 단상 배전 STATCOM의 적용)

  • Kim, Jun-Sang;Lee, Seung-Hyuk;Kim, Jin-O;Lee, Jun-Kyung;Jung, Hyun-Soo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.1
    • /
    • pp.42-51
    • /
    • 2007
  • An AC electrical railroad system has rapidly changing dynamic single-phase load, and at a feeding substation, three-phase electric power is transformed to the paired directional single-phase electric power. There is a great difference in electrical phenomenon between the load of AC electrical railroad system and that of general power system. Electric characteristics of AC electrical railroad's trainload are changed continuously according to the traction, operating characteristic, operating schedule, track slope, etc. Because of the long feeding distance of the dynamic trainload, power quality problems such as voltage drop, voltage imbalance and harmonic distortion my also occur to AC electrical railroad system. These problems affect not only power system stability, but also power quality deterioration in AC electrical railroad system. The dynamic simulation model of AC electrical railroad system presented by PSCAD/EMTDC is modeled in this paper, andthen, it is analyzed voltage drop for AC electrical railroad system both with single-phase distributed STATCOM(Static Synchronous Compensator) installed at SP(Sectioning Post) and without.