• Title/Summary/Keyword: Distance AC/A

Search Result 185, Processing Time 0.023 seconds

The Change in Far Distance and Near Distance of Exophoria Patients (외사위 환자의 원거리와 근거리 때의 변화)

  • Seong, Jeong-Sub;Hong, Soo-Hak
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.7 no.2
    • /
    • pp.143-147
    • /
    • 2002
  • A36 patients of a total of 60 persons show $2{\Delta}$ and less, and the rest of 24 patients show $6{\Delta}$ and less. The patient, who increase more in near distance than far distance in exophoria amount are 27 persons. The unchanging patients are 13 persons, and the patients who phoria amount decreasing are 20 persons. Like this, the patients who phoria amount unchange and decrease show more than the half. That is why convergence increases in near distance. The expected value of horizontal phoria in near distance is $3exo{\pm}3$. Only 13 patients get rid of its value, 47 satisfy its value. In AC/A value, 35 persons show under 3(1ow), 21 persons show 3~5(normal), and 4 persons show more than 5(high). By Percival's theory, 36 patients don't feel a slight asthenopia without correcting phoria. Finally, in near point of convergence 27 patients show 10cm and less, 24 patients show 11~15cm, 3 patients show 15~20cm, and 6 patients show 21~25cm. Most of them show high accommodation.

  • PDF

The Factors Influencing the Asthenopia of Emmetropia with Phoria (사위를 가진 정시안의 안정피로에 영향을 미치는 요인)

  • Kim, Jung-Hee;Lee, Dong-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.1
    • /
    • pp.71-82
    • /
    • 2005
  • The aim of this study was to provide fundamental data for the factors influencing the asthenopia of emmetropia with phoria and alleviation of asthenopia. A total of 348 subjects, aged between 19 and 30 years old, who had no strabismus, an eye trouble or whole body disease, were examined using corrected visual acuity, corrected diopter, stereopsis and suppression tests from September of 2002 to September of 2004. We excluded 21 subjects for the following reasons: if they had an amblyopia affecting binocular vision or inaccurate data. After these exclusions, 327 subjects remained. We then individually measured the refractive error correction, pupillary distance, optical center distance, phoria, convergence, accommodation and the AC/A as well as the asthenopia during binocular vision using a questionnaire. After analysis of factors affecting asthenopia, we also examined the reductive effect of a prism on the asthenopia in subjects who had asthenopia. To determine the factors affecting asthenopia during binocular vision, statistic analyses were carried out using the Chi-square test and the multivariate Logistic regression model. The results of this study were as follow. For asthenopia during near binocular vision of emmetropia with phoria, in case of the lower the accommodation and convergence, a significantly higher rate of asthenopia was observed (p<0.001). When the AC/A is lower, the higher the rate of asthenopia was observed but not significantly and there was no association between phoria and asthenopia. When the multivariate logistic regression model was used to determine factors affecting binocular vision of emmetropia with phoria, in case of the lower accommodation and convergence, a significantly higher rate of asthenopia was observed. when the phoria is esophoria or higher exophoria, or when the AC/A is lower than normal, the higher the rate of asthenopia was observed but not significantly and there was no association between phoria. AC/A and asthenopia. Therefore accommodation and convergence could be predictive factors for asthenopia during near distance binocular vision. Prism was used among' subjects who had asthenopia during near distance binocular vision, the symptom of asthenopia was eased up to 74.2% in emmetropia with phoria.

  • PDF

A Study on the Surface Characteristics of MgO Layer as the Various Deposition Methods of Electron-beam Evaporation (Electron-beam Evaporation의 증착 방법에 따른 MgO Layer의 표면 특성에 관한 연구)

  • Heo, Jeong-Eun;Lee, Don-Kyu;Cho, Sung-Yong;Lee, Hae-June;Lee, Ho-Jun;Park, Chung-Hoo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.5
    • /
    • pp.468-473
    • /
    • 2008
  • A MgO layer is used as electrode protective film in the alternating current plasma display panel (AC PDP). The properties of MgO layer are thought to be one of the most important factors that affects the panel reliability through the firing voltage variation. In this study, we investigated the relations between the surface characteristics and e-beam evaporation process parameters such as deposition rate, temperature of substrate and distance between the MgO pellet and substrate. To produce the MgO layer of (200) crystal orientation, we suggest the high temperature of the substrate, the long distance between the pellet and substrate and the high deposition rate.

Location of Auto Transformer in AC AT Feeding System (교류 AT 급전계통에서의 단권변압기 설치위치의 최적화)

  • Han, M.S.;Lee, J.M.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.1248-1250
    • /
    • 2002
  • AC AT feeding system is possible to do the long distance feeding due to compensate the voltage drop. Nowaday this is a typical and efficient type all over the world in high speed train and heavy transport capacity. Normally a Auto-transformer is installed at regular internal (5 to 10km) between Substation and Sectioning post, this study is reviewed the voltage drop according to train movement and the optimal location of auto transformer, and provided the efficient feeding configuration.

  • PDF

Comparison of Binocular Function and Surgical Outcomes of Tenacious Proximal Fusion and High Accommodative Convergence/Accommodation Ratio Types of Intermittent Exotropia

  • Park, Jun Woo;Lee, Soo Jung
    • Korean Journal of Ophthalmology
    • /
    • v.32 no.6
    • /
    • pp.483-487
    • /
    • 2018
  • Purpose: To compare the characteristics and surgical outcomes in patients with tenacious proximal fusion (TPF) and high accommodative convergence/accommodation ratio (AC/A) types of intermittent exotropia. Methods: This study retrospectively enrolled 40 patients with intermittent exotropia, 23 with TPF and 17 with high AC/A. Binocular function was evaluated by Worth's 4-dot test. Patients underwent lateral rectus recession, and surgical outcomes were compared. Surgical success was defined as less than ${\pm}10$ prism diopters (PD) at 12 months postoperatively. Results: The proportion of diplopia at near, evaluated by Worth's 4-dot test, was significantly higher in patients with high AC/A than in those with TPF (35.3% vs. 4.3%, p = 0.029). The mean preoperative angles of deviation in TPF and high AC/A types were $28.3{\pm}4.4$ and $28.8{\pm}4.5PD$ at distances, and $14.7{\pm}4.2$ and $15.1{\pm}4.1PD$ at near. Twelve months after surgery, the mean angles of deviation in TPF and high AC/A types were $2.9{\pm}9.8$ and $1.2{\pm}9.6PD$, respectively, at distance and $1.7{\pm}7.7$ and $-1.3{\pm}11.3PD$ at near. The surgical success rates were similar in the TPF and high AC/A types (74.0% vs. 64.7%). Five (21.7%) patients with TPF and 2 (11.8%) with high AC/A type experienced recurrence, with consecutive esotropia occurring in 1 (4.3%) patient with TPF and 4 (23.5%) patients with high AC/A. Conclusions: The proportion of diplopia at near was higher in patients with high AC/A type than in those with TPF intermittent exotropia. However, the surgical success rates were not significantly different between the types.

Open Reduction of Acromioclavicular Joint for the Acromioclavicular Joint Dislocations (견봉 쇄골 관절 탈구에 대한 견봉 쇄골 관절의 관혈적 정복술)

  • Song, Hyun-Seok;Choi, Nam-Yong;Han, Suk-Ku;Nah, Ki-Ho;Nam, Won-Sik;Yang, Hyuk-Jae;Park, Sung-Jin
    • Clinics in Shoulder and Elbow
    • /
    • v.9 no.2
    • /
    • pp.189-195
    • /
    • 2006
  • Purpose: To analyze the result of the accurate open reduction of acromioclavicular (AC) joint and pin fixation, coracoclavicular (CC) screw fixation without CC ligament repair for AC joint injuries. Materials and Methods: Between January 2000 and December 2003, seventeen cases with at least one year follow-up among twenty-one cases underwent operation for AC-CC ligament injuries. A transverse incision approximately 5 cm in length was made over the clavicle, and the AC joint was reduced accurately. Under the image intensifier, a cannulated screw and washer were inserted for the CC ligament. Two Steinman pins were inserted for the AC joint and the AC ligament was repaired with nonabsorbable suture. Gentle passive range of motion was begun postoperative 2 weeks. The pins were removed at $6{\sim}8$ weeks and the screw was removed at $10{\sim}12$ weeks. The results were evaluated by a distance between AC and CC joints on plain films and ASES score at last follow-up. Results: At the last follow-up, there was no limitation of motion and average ASES score was 96($86{\sim}100$ points). There was no failure showing over 5 mm difference of distance compared to opposite side on the plain films. Seven cases had the skin damages and local infection due to pin migration and three cases showed the loosening of CC screw. Conclusion: We could have satisfactory results by accurate reduction of AC joint and simple pins and screw fixation for AC-CC ligament injuries.

Analytical and Experimental studies on Dielectric Characteristics of High Voltage Superconducting Machines in Liquid Nitrogen (액체질소를 사용하는 초전도 고전압 전력기기의 절연 특성 연구)

  • Na, J.B.;Ko, T.K.;Kang, H.;Seok, B.Y.;Kim, T.J.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.13 no.1
    • /
    • pp.46-50
    • /
    • 2011
  • The electrical insulation design of high voltage superconducting fault current limiters (SFCLs) should be confirmed to be applied for the stabilization of the power grid. This paper describes numerical analysis and AC dielectric experiments for developing high voltage SFCLs. The electric field distributions between applied high voltage part and ground were calculated by finite element method (FEM) simulation tool and AC criterion of liquid nitrogen at 200 kPa was calculated from correlation between the field utilization factor and FEM simulation results. This paper deals with ceonceptual insulation design of a 154 kV class single-phase no-inductively wound solenoid type SFCL which was focused on gap distance between the cryostat and superconducting coils. Furthermore, the shield ring effect was confirmed to reduce maximum electric field at applied high voltage part.

Morphotypes of the apical constriction of maxillary molars: a micro-computed tomographic evaluation

  • Jeffrey Wen-Wei Chang;Kuzhanchinathan Manigandan;Lakshman Samaranayake;Chellapandian NandhaKumar;Pazhamalai AdhityaVasun;Johny Diji;Angambakkam Rajasekharan PradeepKumar
    • Restorative Dentistry and Endodontics
    • /
    • v.47 no.2
    • /
    • pp.19.1-19.15
    • /
    • 2022
  • Objectives: The aim of this study was to evaluate and compare the apical constriction (AC) and apical canal morphology of maxillary first and second molars, using micro-computed tomography (micro-CT). Materials and Methods: The anatomical features of 313 root canals from 41 maxillary first molars and 57 maxillary second molars of patients with known age and sex were evaluated using micro-CT, with a resolution of 26.7 ㎛. The factors evaluated were the presence or absence of AC, the morphotypes, bucco-lingual dimension, mesio-distal dimension, and the profile (shape) of AC and the apical root canal. The apical root canal dimensions, location of the apical foramen (AF), AC to AF distance, and presence of accessory canals in the apical 5 mm were also assessed. Descriptive and analytical statistics were used for data evaluation. Results: AC was present in all 313 root canals. Patients' age and sex did not significantly impact either AC or the apical canal dimensions. The most common AC morphotype detected was the traditional (single) constriction (52%), followed by the parallel (29%) morphotype. The mean AC dimensions in maxillary first molars were not significantly different from those in maxillary second molars. Sixty percent of AF were located within 0.5 mm from the anatomic apex. Conclusions: The most common morphotype of AC detected was the traditional constriction. Neither patients' age nor sex had a significant impact on the dimensions of the AC or the apical root canal. The majority of AF (60%) were located within 0.5 mm from the anatomic apex.

Shift of the Brain during Functional Neurosurgery

  • Kim, Suk-Min;Hwang, Hyung-Sik;Salles, Antonio De
    • Journal of Korean Neurosurgical Society
    • /
    • v.38 no.5
    • /
    • pp.359-365
    • /
    • 2005
  • Objective : The study investigates the extent of brain shift and its effect on the accuracy of the stereotaxic procedure. Methods : Thirty-five patients underwent 40stereotactic procedures between June 2002 and March 2004. There were 26 males, mean age 59years old. There were 34procedures for Parkinson's disease, 2 for essential tremor, 3 for cerebral palsy, 1 for dystonia. Patients were divided in four groups based on postoperative pneumocephalus : under 5cc [9 procedures], between $5{\sim}10cc$ [13procedures], between $10{\sim}15cc$ [11 procedures] and more than 15cc [7procedures]. The coordinates of the anterior commissure[AC], posterior commissure[PC], and target were defined in pre-and intraoperative magnetic resonance image scans and the amount of air volume was measured with @Target (BrainLab, Heimstetten, Germany]. Results : The mean AC-PC was 26.5mm for patients with less than 5cc, 26.9mm for $5{\sim}10cc$, 25.8mm for $10{\sim}15cc$ and 26.2mm for more than 15cc. The length of AC-PC line and coordinates of AC, PC was also not statistically different, Euclidean distance as well as ${\Delta}x$, ${\Delta}y$, ${\Delta}z$ of AC, PC, and target were also not statistically different among the groups [p>,1]. There was a variance in target of $0.7{\sim}7.6mm$, Euclidean distance of 2.5mm, related to electrophysiology but not to brain-shift. Conclusion : The amount of air accumulated in the intracranial space and compressing the cortical surface has no effect on the localization of subcortical stereotactic target and landmarks.

Changes in Visual Acuity and Values of Objective Refraction with Breath Alcohol Concentration (호흡 알코올 농도에 따른 시력과 타각적 굴절검사 값의 변화)

  • Jung, Su A;Nam, Soo-Kyung;Kim, Hyun Jung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.2
    • /
    • pp.187-193
    • /
    • 2015
  • Purpose: This study was aimed to investigate effects of increased breath alcohol concentration (BrAC) which is the standard measurement of alcohol consumption in sobriety test under current laws on visual acuity and values of objective refraction. Methods: For twenty three males in 20s (average age $21.17{\pm}2.19$ years, body mass index (BMI) $22.09{\pm}2.16$) were selected. Distance and near visual test was performed at BrAC of 0%, 0.05% and 0.08%, and objective refraction with open-field auto-refractometer was also performed at different BrAC. Results: As breath alcohol concentration is increased, distance visual acuity was decreased, which was statistically significant, but near visual acuity was not changed. Also, values of objective refraction tended to be increased towards minus as breath alcohol concentration is increased. Conclusions: As breath alcohol concentration is increased, corrected visual acuity is decreased and refractive power is towards minus, it is necessary that visual acuity test and refraction measurement should be conducted under sober condition.