• Title/Summary/Keyword: Distal tibia

Search Result 133, Processing Time 0.029 seconds

A Comparative Study of Interlocking IM Nailing and LCP Fixation through MIPPO Technique in the Treatment of Distal Metaphyseal Tibial Fracture (경골 원위부 골절 치료에서 최소 침습적 접근법을 통한 잠금 나사 금속판 고정술과 교합성 골수강 내 금속정 고정술의 비교 연구)

  • Lee, Chang-Soo;Suh, Jin-Soo;Kim, Ji-Hoon
    • Journal of Korean Foot and Ankle Society
    • /
    • v.12 no.1
    • /
    • pp.80-85
    • /
    • 2008
  • Purpose: To evaluate and compare the outcome between interlocking IM nailing and LCP fixation in the treatment of distal metaphyseal tibial fracture. Materials and Methods: From January 2000 to December 2007, 17 patient were treated by interlocking IM nail and 13 patient were treated by LCP fixation for distal metaphyseal tibial fracture. Results: According to AO classification, there were 2 type A1 fracture (12%), 6 type A2 fracture (36%), 3 type A3 fracture (18%), 4 type B1 fracture (24%), 1 type B3 fracture (6%), 1 type C1 fracture (6%) in interlocking IM nailing group and 1 type A2 fracture (7.7%), 2 type A3 fracture (15.4%), 3 type B1 fracture (23%), 3 type B2 fracture (23%), 3 type C1 fracture (23%), 1 type C2 fracture (7.7%) in LCP fixation group. The clinical functional outcome (according to AOFAS score) is 75.6 point in IM nailing group and 81.5 point in LCP fixation group. In IM nailing group, 65% of patient showed satisfactory result and In LCP fixation group, 77% of patient showed satisfactory result. Conclusion: There is no difference on clinical results between IM nailing and MIPPO (minimal invasive percutaneous plate osteosynthesis) group in the treatment of distal tibia fracture. But MIPPO group have higher subjective satisfactory score and less complication rate. The weakness of our study is a small case number and limited follow-up and we believe a better designed prospective study will be needed.

  • PDF

Free Vascularized Fibular Transfer with Double Barrel Fashion (혈관부착 생비골 중첩 이식술)

  • Chung, Duke-Whan
    • Archives of Reconstructive Microsurgery
    • /
    • v.7 no.1
    • /
    • pp.54-61
    • /
    • 1998
  • Free vascularized fibular is the most usuful bony donor of the long bone reconstruction in reconstructive microsurgical field. It has many benifits such as very strong strut tubular bone, very reliable vascular anatomy with large vascular diameter with long pedicle, minimal donor site morbity too. In that situations of the huge long bone defects in distal femur or proximal tibia, the defective bony shape and strength of the transplanted fibular bone is not enough if only one strut of the fibula is transfered. The bony circulation of the fibula has two ways, one from nutrient artery via peroneal artery through nutrient foramen which makes endosteal arterial network inside of the fibula, another way is periosteal network through outside encircling vascular network of the bone which distributed in muscle sleeves of the fibular diaphysis. Authors modified free vascularized fibular bone graft with transverse osteotomy is made from the anterolateral aspect of the fibular shaft just distal to entry of the nutrient artery. This produces two vascularized bone struts that may be folded pararell to each other but that remain connected by the periosteum and muscle cuff surrounding the peroneal artery and veins. The proximal strut is vascularized by both a periosteal and endosteal blood supply, whereas the distal strut is vascularized by a periosteal blood supply alone. This procedure can call "doule barrel" free vascularized fibular graft. We performed 7 cases of doule barrel fashined fibular transplantation on distal femur and proximal tibial large defects. Average bone union time takes 7 months from that procedure. There were no significant bone union time differences between both proximal and distal struts. After solid union of the transfered double barrel fibular graft, there were no stress fracture in our series. We can propose double barrel free vascualized fibular graft is usuful method in that cases with very large bone defect on large long bones especially metaphyseal defects.

  • PDF

Experimental Studies on Heat Conductivity of Human Bone and Torsional Strength of Pasteurized Porcine Tibia (생체골의 열전도성 및 열처리된 골의 염전력 변화에 대한 실험적 연구)

  • Park, Il-Hyung;Kim, Sin-Gun;Shin, Dong-Kyu;Ihn, Joo-Chul
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.1 no.1
    • /
    • pp.7-16
    • /
    • 1995
  • In countries where confucianism is popular, it is extremely hard to get fresh cadaver bone for allograft. Therefore in Korea, the reimplantation of resected autoclaved autogenous bone segments has been increasingly performed for limb reconstruction of extremities with malignancies. To preserve the bone morphogenetic protein and mechanical strength of heated bone, many studies have reported that pasteurization of bone is far better than autoclaving over $100^{\circ}C$. Based on this assumption, replacement with a pasteurized autogenous bone graft after resection of a malignant bone tumor was deemed feasible for reconstruction. However, little is known about how high a temperature and how much time for pasteurization is needed to make tumors completely necrotic and to maintain the mechanical strength of bone. Consequantly, experimental studies were carried out to test heat conductivity of human bone and torsional strength of porcine tibia after pasteurization. First, two pairs of human proximal tibia and distal femur were used. We used T-type thermocoples to check core temperature of the bone and a computerized data acquisition system to record results. Without reaming of the medullary cavity, in a $60^{\circ}C$-thermostatic saline tub, it took 32 minutes and 50 seconds to raise the core temperature of human proximal tibia from $20^{\circ}C$ to $58^{\circ}C$, and 30 minutes for distal femur. In a $80^{\circ}C$ saline tub, it took 12 minutes and 50 seconds for proximal tibia, and 11 minutes and 10 seconds for distal femur. In contrast, using porcine tibia whose cortical thickness is similar to that of human tibia, after reaming of the medullary canal, it took less than 3 minutes and 30 seconds in a $60^{\circ}C$ saline tub, less than 1 minute and 45 seconds in a $70^{\circ}C$ tub, and less than 1 minute in a $80^{\circ}C$ tub to elevate core temperature from $20^{\circ}C$ to $58^{\circ}C$. Second, based on data of the heat conductivity test, we compared the torsional strength before and after pasteurization. Twenty matched pairs of porcine tibia were used, The left one was used as a non-heated control group and the right one as a pasteurized experimental group. Wighout reaming of the medullary cavity, there was no statistical difference in torsional strength between the pasteurization of the $60^{\circ}C$-35minute and of $80^{\circ}C$-15minute. With reaming, we also found no statistical difference among pasteurization of $60^{\circ}C$-15 minute, of $70^{\circ}C$-15 minute, and of $80^{\circ}C$-15 minute groups. In conclusion, reaming of the medullary canal is very helpful in saving pasteurization time. And, in a $60^{\circ}C$ saline tub, no significant weakness in torsional strength occurs with pasteurization of the bone for up to 35 minutes. Also no significant weakness in torsional strength occurs with an exposure of 15 minutes to the $80^{\circ}C$ saline tub.

  • PDF

Operative Treatment with Anatomically Preshaped Locking Compression Plate in Distal Fibular Fracture (해부학적 잠김 압박 금속판을 이용한 원위 비골 골절의 치료)

  • Chung, Hyung-Jin
    • Journal of Korean Foot and Ankle Society
    • /
    • v.17 no.2
    • /
    • pp.130-135
    • /
    • 2013
  • Purpose: Preshaped Locking compression plate(LCP) has holes with fixed angle between screw and plate and have advantage firm fixation because it has stability of angular and axial deformity. We evaluated usefulness of LCP after open reduction and internal fixation in distal fibular fracture. Materials and Methods: Between December 2011 and May 2012, 23 patients with fracture of distal fibula were followed up at least 12 months underwent open reduction and internal fixation with LCP. There were 15 males and 8 females with a mean age 39.8(20~69) years. According to Danis-Weber classification, there were 20 cases of type B and 3 cases of type C. There were 13 cases of isolated lateral malleolus fractures, 1 case of bimalleolar fracture, 6 cases of trimalleolar fractures and 3 cases of distal tibia fractures with proximal fibula fracture. Intraoperatively, we assessed whether preshaped LCP fit lateral margin of distal fibula or not and evaluated quality of reduction and postoperative complications. The cases were analyzed by radiological bone union time and clinical results according to the criteria of Meyer Results: Of all cases, complete bone union was achieved and average radiological bone union time was 7.3(6~12) weeks. The clinical results were excellent in 18 cases(78%), good in 5 cases(22%). There were 5 cases of plate with 3 holes, 13 cases of plate with 4 holes, 2 cases of plate with 5 holes, 1 case of plate with 6 holes and 2 cases of plate with 7 holes. The average number of screws at proximal fragement was 2.5 and at distal fragment was 3.5. In 14 cases (60.8 %), we needed re-bending of plate because the distance between plate and lateral cortical margin of distal fibula was more than 5 mm at anteroposterior X-ray after reduction. All cases have anatomical reduction and there were no complications of wound infections. There were no complaint about hardware irritation. Conclusion: At fractures of distal fibula,preshaped LCP had a excellent stability although far cortex was not fixed with screw and bending of plate. And there are less complications of hardware irritation and wound problems. But, Some complement would be needed because there were no complete fitting between precontour of LCP and lateral cortical margin of distal fibula.

Reconstruction of Tibia Defect with Free Flap Followed by Ipsilateral Fibular Transposition (유리 피판술과 동측 비골 전위술을 이용한 경골 결손의 재건)

  • Chung, Duke-Whan;Park, Jun-Young;Han, Chung-Soo
    • Archives of Reconstructive Microsurgery
    • /
    • v.14 no.1
    • /
    • pp.42-49
    • /
    • 2005
  • Between June 1989 and may 2004 Ipsilateral vascularized fibular transposition was performed on nine patients with segmental tibial defects combined with infection following trauma. Ipsilateral vascularized fibular graft was performed on two or three stage according to the degree of infection. Initially free vascular pedicled graft was done followed by ipsilateral vascularized fibular graft. Type of free flap used is scapular free flap 3 cases, latissimus dorsi free flap 5 cases and dorsalis pedis flap 1 cases. The patients were followed for an average of 3.4 years. the average time to union was 6.7 months, and in all patients the graft healed in spite of complication. Complication was free flap venous thrombosis in 1 cases, persistent infection in 1 cases, delayed bony union at the distal end of fibular graft in 2 cases. The results showed that more faster bony union was seen in which cases firmly internally fixated and more faster hypertrophy of graft in which cases was permitted to ambulate on early weight bearing and more faster healing in which cases debrided more meticulously. Reconstruction of tibia defect with free flap followed by Ipsilateral fibular transposition is a useful and safe method to avoid the potential risk of infection for patients with tibial large bone defect and soft tissue defect associated with infection.

  • PDF

Investigation into the Development of Technology for Orthopeadic Surgery Utilizing Reverse Engineering and Rapid Prototyping Technology (역공학과 쾌속조형공정을 이용한 정형외과수술기법 개발에 관한 연구)

  • 안동규;이준영;양동열;한길영
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.6
    • /
    • pp.188-196
    • /
    • 2004
  • The objective of this paper is to propose a new technology of the orthopaedic surgery using the combination of reverse engineering (RE) based on CT data and rapid prototyping (RP). The proposed technology utilizes symmetrical characteristics of the human body and capability of the combination of RE and RP, which rapidly manufactures three-dimensional parts from CT data. The original .stl data of injured extents are generated from the mirror transformation of .stl file fur uninjured extents. The physical shape before injuring is manufactured from RP using the original .stl data. Subsequently, pre-operative planning, such as a selection of proper implants, preforming of the implant, a decision of fixation locations and an insert position for the implant, an estimation of the invasive size, and pre-education of operators are performed using the physical shape. In order to examine the applicability and the efficiency of the proposed surgical technology, various case studies, such as a distal tibia commented fracture, a proximal tibia plateau fracture and an iliac wing fracture of pelvis, are carried out. From the results of case studies, it has been shown that the proposed technology is an effective surgical tool of the orthopaedic surgery reducing the operational time, the operational cost, the radiation exposure of the patient and operators, and morbidity. In addition, the proposed technology could improve the accuracy of operation and the speed of rehabilitation.

Current Treatment of Tibial Pilon Fractures (경골 천정(pilon) 골절의 최신 치료)

  • Lee, Jun-Young
    • Journal of Korean Foot and Ankle Society
    • /
    • v.15 no.2
    • /
    • pp.51-57
    • /
    • 2011
  • Pilon fractures involving distal tibia remain one of the most difficult therapeutic challenges that confront the orthopedic surgeons because of associated soft tissue injury is common. To introduce and describe the diagnosis, current treatment, results and complications of the pilon fractures. In initial assessment, the correct evaluation of the fracture type through radiographic checkup and examination of the soft tissue envelope is needed to decide appropriate treatment planning of pilon fractures. Even though Ruedi and Allgower reported 74% good and excellent results with primary open reduction and internal fixation, recently the second staged treatment of pilon fractures is preferred to orthopedic traumatologist because of the soft tissue problem is common after primary open reduction and internal fixation. The components of the first stage are focused primarily on stabilization of the soft tissue envelope. If fibula is fractured, fibular open reduction and internal fixation is integral part of initial management for reducing the majority of tibial deformities. Ankle-spanning temporary external fixator is used to restore limb alignment and displaced intraarticular fragments through ligamentotaxis and distraction. And the second stage, definitive open reduction and internal fixation of the tibial component, is undertaken when the soft tissue injury has resolved and no infection sign is seen on pin site of external fixator. The goals of definitive internal fixation should include absolute stability and interfragmentary compression of reduced articular segments, stable fixation of the articular segment to the tibial diaphysis, and restoration of coronal, transverse, and sagittal plane alignments. The location, rigidity, and kinds of the implants are based on each individual fractures. The conventional plate fixation has more advantages in anatomical reduction of intraarticular fractures than locking compression plate. But it has more complications as infection, delayed union and nonunion. The locking compression plate fixation provides greater stability and lesser wound problem than conventional implants. But the locking compression plate remains poorly defined for intraarticular fractures of the distal tibia. Active, active assisted, passive range of motion of the ankle is recommended when postoperative rehabilitation is started. Splinting with the foot in neutral is continued until suture is removed at the 2~3 weeks and weight bearing is delayed for approximately 12 weeks. The recognition of the soft tissue injury has evolved as a critical component of the management of pilon fractures. At this point, the second staged treatment of pilon fractures is good treatment option because of it is designed to promote recovery of the soft tissue envelope in first stage operation and get a good result in definitive reduction and stabilization of the articular surface and axial alignment in second stage operation.

A Newly Designed Miniplate Staple for High Tibial Osteotomy (근위골절술을 위한 Staple 설계)

  • Mun, Mu-Seong;Bae, Dae-Kyung
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1995 no.05
    • /
    • pp.19-22
    • /
    • 1995
  • A biomechanical study was made to demonstrate the superior mechanical performance of the newly designed Miniplate staple to the conventional Coventry staple in high tibial osteotomy(HTO). Using twenty fresh porcine tibiae, the fixational strengh of the two different types of staple in HTO was compared. To minimize the error due to the specimen-to-specimen individuality, the bone mineral density of the tibiae was measured with a bone densitometry (Dual photon absorptionometer, Luner, USA) and those with $0.8\;{\sim}\;1.2\;gm/cm^2$ at the proximal tibia was used in the biomechanical test. Testing was performed on a material testing system (Autogram ET-5, Shimatzu, Japan) with aid of a commercial data processor (IBM 80386/ ASYST). Using two differant loading modes, 'pull-out' and 'push-out', the maximum resistant force required to release the staple from the substrate bone was recorded. In the pull-out test, ten non-osteotomized specimens were used and the staple was pullout by subjecting an axial tension on the head of the staple inserted. While in the pull-out test where ten tibiae osteotomized in the usual way of HTO were used, the staple was not directly loaded. In this testing, as a mimic condition of the natural knee, the distal part of the specimen tibia was pushed horizontally in order for the staple to be pulled out while the proximal tibia was fixed. The pull-out strength of Coventry staple and miniplate staple were found to be $27.88\;{\pm}\;5.12\;kgf$ and $182.47\;{\pm}\;32.75\;kgf$, respectively. The push-out strength of Coventry staple and miniplate staple were $18.40\;{\pm}\;4.47\;kgf$ and $119.95\;{\pm}\;19.06\;kgf$, respectively. The result revealed that miniplate staple had the pull-out/ push-out strength at least fivetimes higher than Coventry staple. Based on the measured data, it was believed that the newly designed miniplate staple could provide much better postoperative fixation in HTO. The postoerative application of long leg casting may not be needed after HTO surgery.

  • PDF

Pathological fracture induced by Halicephalobus gingivalis (Nematoda: Rhabditida) in a horse limb

  • Ticiana Meireles Sousa;Hugo Shisei Toma;Antonio de Padua Lima;Antonio Carlos Cunha Lacreta Junior;Maira Meira Nunes;Ana Paula Cassiano da Silva;Daniel Wouters;Adriana Silva Albuquerque;Mary Suzan Varaschin;Djeison Lutier Raymundo;Claudia Dias Monteiro Toma;Fernando Arevalo Batista
    • Parasites, Hosts and Diseases
    • /
    • v.62 no.1
    • /
    • pp.131-138
    • /
    • 2024
  • Halicephalobus gingivalis is a free-living nematode that occasionally causes infections in horses. We report a rare case of limb fracture of horse caused by infection with H. gingivalis. An 8-year-old mare was referred to the Veterinary Hospital of the Federal University of Lavras with claudication grade 5 of the right hind limb, that had been started 3 months ago. The patient had aseptic arthritis in the tarsal joint and edema that extended to the quartile. The radiographic examination showed punctate osteolysis with exacerbation of bone trabeculation along the calcaneus, talus, proximal epiphysis of the third metatarsal and distal epiphysis of the tibia. Treatment for arthritis was initiated, and the animal showed a slight improvement in limb function. However, 21 days after hospitalization, due to a comminuted fracture of the tibia, it was euthanized. At necropsy, yellowish masses were found from the metatarsal to the tibia, and around the tarsal bones and joint. Similar masses were also found in the left kidney. Numerous nematodes compatible with H. gingivalis were identified. This is the first description of a pathological fracture caused by H. gingivalis infection in an equine limb.

Treatment of Tibial Fractures by Interlocking Intramedullary Nailing (Interlocking Intramedullary Nail을 이용한 경골 골절의 치료)

  • Jung, Kwang-Yeoung;Lee, Dong-Chul;Suh, Jae-Sung;Kim, Se-Dong
    • Journal of Yeungnam Medical Science
    • /
    • v.10 no.2
    • /
    • pp.388-399
    • /
    • 1993
  • The adequate treatment of tibia fracture is one of the most difficult due to severe commiuntion, open wound, delayed union, angulation deformity and infection. We treated 38 fractures of the tibia by Interlocking intramedullary nail from Feb. 1983 to Mar. 1993, 35 cases of the tibia fracture were fresh, 13 cases of fracture were open. The other 3 cases were delayed union and nonunion. The Mean follow-up was 14.0 months. The results were as followings. 1. Of the 38 fractures, 37 fractures united and the mean union time was 18.7 weeks. 2. Interlocking intramedullary nail could be used to the majority of fractures of the proximal & distal tibia shaft fractures. 3. The Interlocking nail had rigid rotational stability and was appropriate for the treatment in severe unstable fractures, commninution and open with bone loss. 4. Delayed union or nonunion was a good indication for intramedullary nailling. 5. The major complication were valgus deformity of 2 cases, varus deformity of 1 case, 1 case deep infection. 6. Interlocking intramedullary nailing provided rigid fixation of fracture and then made early joint motion exercise and ambulation.

  • PDF