• 제목/요약/키워드: Distal tibia

검색결과 135건 처리시간 0.021초

Osteocutaneous Turn-Up Fillet Flaps: A Spare-Parts Orthoplastic Surgery Option for a Functional Posttraumatic Below-Knee Amputation

  • Harry Burton;Alexios Dimitrios Iliadis;Neil Jones;Aaron Saini;Nicola Bystrzonowski;Alexandros Vris;Georgios Pafitanis
    • Archives of Plastic Surgery
    • /
    • 제50권5호
    • /
    • pp.501-506
    • /
    • 2023
  • This article portrays the authors' experience with a complex lower limb bone and soft tissue defect, following chronic osteomyelitis and pathological fracture, which was managed by the multidisciplinary orthoplastic team. The decision for functional amputation versus limb salvage was deemed necessary, enhanced by the principles of "spare parts" in reconstructive microsurgery. This case describes the successful use of the osteocutaneous distal tibia turn-up fillet flap that allowed "lowering the level of the amputation" from a through knee to a below-knee amputation (BKA) to preserve the knee joint function. We comprehensibly review reports of turn-up flaps which effectively lower the level of amputation, also applying "spare-parts" surgery principles and explore how these concepts refine complex orthoplastic approaches when limb salvage is not possible to enhance function. The osteocutaneous distal tibia turn-up fillet flap is a robust technique for modified BKA reconstructions that provides sufficient bone length to achieve a tough, sensate stump and functional knee joint.

경골 원위부 골절 치료에서 최소 침습적 접근법을 통한 잠금 나사 금속판 고정술과 교합성 골수강 내 금속정 고정술의 비교 연구 (A Comparative Study of Interlocking IM Nailing and LCP Fixation through MIPPO Technique in the Treatment of Distal Metaphyseal Tibial Fracture)

  • 이창수;서진수;김지훈
    • 대한족부족관절학회지
    • /
    • 제12권1호
    • /
    • pp.80-85
    • /
    • 2008
  • Purpose: To evaluate and compare the outcome between interlocking IM nailing and LCP fixation in the treatment of distal metaphyseal tibial fracture. Materials and Methods: From January 2000 to December 2007, 17 patient were treated by interlocking IM nail and 13 patient were treated by LCP fixation for distal metaphyseal tibial fracture. Results: According to AO classification, there were 2 type A1 fracture (12%), 6 type A2 fracture (36%), 3 type A3 fracture (18%), 4 type B1 fracture (24%), 1 type B3 fracture (6%), 1 type C1 fracture (6%) in interlocking IM nailing group and 1 type A2 fracture (7.7%), 2 type A3 fracture (15.4%), 3 type B1 fracture (23%), 3 type B2 fracture (23%), 3 type C1 fracture (23%), 1 type C2 fracture (7.7%) in LCP fixation group. The clinical functional outcome (according to AOFAS score) is 75.6 point in IM nailing group and 81.5 point in LCP fixation group. In IM nailing group, 65% of patient showed satisfactory result and In LCP fixation group, 77% of patient showed satisfactory result. Conclusion: There is no difference on clinical results between IM nailing and MIPPO (minimal invasive percutaneous plate osteosynthesis) group in the treatment of distal tibia fracture. But MIPPO group have higher subjective satisfactory score and less complication rate. The weakness of our study is a small case number and limited follow-up and we believe a better designed prospective study will be needed.

  • PDF

혈관부착 생비골 중첩 이식술 (Free Vascularized Fibular Transfer with Double Barrel Fashion)

  • 정덕환
    • Archives of Reconstructive Microsurgery
    • /
    • 제7권1호
    • /
    • pp.54-61
    • /
    • 1998
  • Free vascularized fibular is the most usuful bony donor of the long bone reconstruction in reconstructive microsurgical field. It has many benifits such as very strong strut tubular bone, very reliable vascular anatomy with large vascular diameter with long pedicle, minimal donor site morbity too. In that situations of the huge long bone defects in distal femur or proximal tibia, the defective bony shape and strength of the transplanted fibular bone is not enough if only one strut of the fibula is transfered. The bony circulation of the fibula has two ways, one from nutrient artery via peroneal artery through nutrient foramen which makes endosteal arterial network inside of the fibula, another way is periosteal network through outside encircling vascular network of the bone which distributed in muscle sleeves of the fibular diaphysis. Authors modified free vascularized fibular bone graft with transverse osteotomy is made from the anterolateral aspect of the fibular shaft just distal to entry of the nutrient artery. This produces two vascularized bone struts that may be folded pararell to each other but that remain connected by the periosteum and muscle cuff surrounding the peroneal artery and veins. The proximal strut is vascularized by both a periosteal and endosteal blood supply, whereas the distal strut is vascularized by a periosteal blood supply alone. This procedure can call "doule barrel" free vascularized fibular graft. We performed 7 cases of doule barrel fashined fibular transplantation on distal femur and proximal tibial large defects. Average bone union time takes 7 months from that procedure. There were no significant bone union time differences between both proximal and distal struts. After solid union of the transfered double barrel fibular graft, there were no stress fracture in our series. We can propose double barrel free vascualized fibular graft is usuful method in that cases with very large bone defect on large long bones especially metaphyseal defects.

  • PDF

생체골의 열전도성 및 열처리된 골의 염전력 변화에 대한 실험적 연구 (Experimental Studies on Heat Conductivity of Human Bone and Torsional Strength of Pasteurized Porcine Tibia)

  • 박일형;김신근;신동규;인주철
    • 대한골관절종양학회지
    • /
    • 제1권1호
    • /
    • pp.7-16
    • /
    • 1995
  • 인체골 4 시편(specimen)과 돼지 경골 25쌍을 이용하여, 생체골의 열전도성 측정과 열처리후 열처리온도와 시간에 따른 골의 염전력을 실험한 결과를 요약하면 다음과 같다. 인체골에 있어서 골수강을 제거하지 않고 $60^{\circ}C$의 항온식염수에서 열처리하면, 골심부의 온도가 $20^{\circ}C$에서 $58^{\circ}C$에 도달하는데 소요된 시간은 경골근위부가 32분 50초, 대퇴골 원위부가 30.분, $80^{\circ}C$ 항온조에서는 경골근위부가 12분 50초, 대퇴골 원위부가 11분 10초 소요되었다. 돼지 경골간부의 피질골내부(endosteum)에 열전대를 부착하고 뼈 양끝을 밀봉하여 같은 실험을 행한 결과 $50^{\circ}C$까지는 시간에 비례해서 일정한 비율로 온도상승이 이루어 졌으며, $20^{\circ}C$에서 $58^{\circ}C$에 이르는 시간이 $60^{\circ}C$ 항온조에서는 7분, $70^{\circ}C$에서는 3분 30초, $80^{\circ}C$에서는 2분이었다. 따라서 임상에서 골수강을 제거 후 장골의 간부(shaft) 만을 항온조에 달굴때는 골구강내에도 데워진 심염수로 가득차게 되므로 상기 시간의 절반이 못되는 짧은 시간내에 피질골의 내부가 $58^{\circ}C$에 이르리라고 판단되었다. 골수강을 소파하지 않은 돼지 경골을 각각 4쌍씩 우측만을 $60^{\circ}C$ 35분, $80^{\circ}C$ 15분 열처리한 후 실험군의 최대염전력은 대조군과 비교할 때 +7.0%, -5.1%, -3.2%, -4.2%의 변화가 있었고, $80^{\circ}C$ 15분 열처리후는 -4.3%, -3.8%, -1.4%(1예는 실험 오류로 제외됨)의 변화가 있었다. 골수강을 완전 제거한 되재 경골을 각각 4쌍씩 우측만을 $60^{\circ}C$, $70^{\circ}C$, $80^{\circ}C$에서 15분 열처리 후 실험군의 최대염전력은 대조군과 비교할 때 -3.4%, -4.2%, -0.7%, +2.7%의 변화가 있었고, $70^{\circ}C$ 15분 열처리후는 -2.8%, -3.9%, -2.1%(1예는 실험 오류로 제외됨)의 변화가 있었으며, $80^{\circ}C$ 15분 열처리후는 +5.2%, -4.4%, -2.9%, -0.3%의 염전력 변화가 있었다. 그러므로 골수강을 제거하지 않고 $80^{\circ}C$ 35분, $60^{\circ}C$ 15분 열처리 하거나, 골수강을 완전소파 후 $60^{\circ}C$ 15분, $70^{\circ}C$ 15분, $80^{\circ}C$ 15분 열처리해서는 각군사이에 염전력의 유의한 차이는없었다. 이상의 결과로 돼지 경골의 경우 $60^{\circ}C$ 항온에서는 35분까지, $80^{\circ}C$이하의 항온에서는 15분까지 열처리하여도 골강도에는 거의 영향이 없는 것으로 나타났다.

  • PDF

해부학적 잠김 압박 금속판을 이용한 원위 비골 골절의 치료 (Operative Treatment with Anatomically Preshaped Locking Compression Plate in Distal Fibular Fracture)

  • 정형진
    • 대한족부족관절학회지
    • /
    • 제17권2호
    • /
    • pp.130-135
    • /
    • 2013
  • Purpose: Preshaped Locking compression plate(LCP) has holes with fixed angle between screw and plate and have advantage firm fixation because it has stability of angular and axial deformity. We evaluated usefulness of LCP after open reduction and internal fixation in distal fibular fracture. Materials and Methods: Between December 2011 and May 2012, 23 patients with fracture of distal fibula were followed up at least 12 months underwent open reduction and internal fixation with LCP. There were 15 males and 8 females with a mean age 39.8(20~69) years. According to Danis-Weber classification, there were 20 cases of type B and 3 cases of type C. There were 13 cases of isolated lateral malleolus fractures, 1 case of bimalleolar fracture, 6 cases of trimalleolar fractures and 3 cases of distal tibia fractures with proximal fibula fracture. Intraoperatively, we assessed whether preshaped LCP fit lateral margin of distal fibula or not and evaluated quality of reduction and postoperative complications. The cases were analyzed by radiological bone union time and clinical results according to the criteria of Meyer Results: Of all cases, complete bone union was achieved and average radiological bone union time was 7.3(6~12) weeks. The clinical results were excellent in 18 cases(78%), good in 5 cases(22%). There were 5 cases of plate with 3 holes, 13 cases of plate with 4 holes, 2 cases of plate with 5 holes, 1 case of plate with 6 holes and 2 cases of plate with 7 holes. The average number of screws at proximal fragement was 2.5 and at distal fragment was 3.5. In 14 cases (60.8 %), we needed re-bending of plate because the distance between plate and lateral cortical margin of distal fibula was more than 5 mm at anteroposterior X-ray after reduction. All cases have anatomical reduction and there were no complications of wound infections. There were no complaint about hardware irritation. Conclusion: At fractures of distal fibula,preshaped LCP had a excellent stability although far cortex was not fixed with screw and bending of plate. And there are less complications of hardware irritation and wound problems. But, Some complement would be needed because there were no complete fitting between precontour of LCP and lateral cortical margin of distal fibula.

유리 피판술과 동측 비골 전위술을 이용한 경골 결손의 재건 (Reconstruction of Tibia Defect with Free Flap Followed by Ipsilateral Fibular Transposition)

  • 정덕환;박준영;한정수
    • Archives of Reconstructive Microsurgery
    • /
    • 제14권1호
    • /
    • pp.42-49
    • /
    • 2005
  • Between June 1989 and may 2004 Ipsilateral vascularized fibular transposition was performed on nine patients with segmental tibial defects combined with infection following trauma. Ipsilateral vascularized fibular graft was performed on two or three stage according to the degree of infection. Initially free vascular pedicled graft was done followed by ipsilateral vascularized fibular graft. Type of free flap used is scapular free flap 3 cases, latissimus dorsi free flap 5 cases and dorsalis pedis flap 1 cases. The patients were followed for an average of 3.4 years. the average time to union was 6.7 months, and in all patients the graft healed in spite of complication. Complication was free flap venous thrombosis in 1 cases, persistent infection in 1 cases, delayed bony union at the distal end of fibular graft in 2 cases. The results showed that more faster bony union was seen in which cases firmly internally fixated and more faster hypertrophy of graft in which cases was permitted to ambulate on early weight bearing and more faster healing in which cases debrided more meticulously. Reconstruction of tibia defect with free flap followed by Ipsilateral fibular transposition is a useful and safe method to avoid the potential risk of infection for patients with tibial large bone defect and soft tissue defect associated with infection.

  • PDF

역공학과 쾌속조형공정을 이용한 정형외과수술기법 개발에 관한 연구 (Investigation into the Development of Technology for Orthopeadic Surgery Utilizing Reverse Engineering and Rapid Prototyping Technology)

  • 안동규;이준영;양동열;한길영
    • 한국정밀공학회지
    • /
    • 제21권6호
    • /
    • pp.188-196
    • /
    • 2004
  • The objective of this paper is to propose a new technology of the orthopaedic surgery using the combination of reverse engineering (RE) based on CT data and rapid prototyping (RP). The proposed technology utilizes symmetrical characteristics of the human body and capability of the combination of RE and RP, which rapidly manufactures three-dimensional parts from CT data. The original .stl data of injured extents are generated from the mirror transformation of .stl file fur uninjured extents. The physical shape before injuring is manufactured from RP using the original .stl data. Subsequently, pre-operative planning, such as a selection of proper implants, preforming of the implant, a decision of fixation locations and an insert position for the implant, an estimation of the invasive size, and pre-education of operators are performed using the physical shape. In order to examine the applicability and the efficiency of the proposed surgical technology, various case studies, such as a distal tibia commented fracture, a proximal tibia plateau fracture and an iliac wing fracture of pelvis, are carried out. From the results of case studies, it has been shown that the proposed technology is an effective surgical tool of the orthopaedic surgery reducing the operational time, the operational cost, the radiation exposure of the patient and operators, and morbidity. In addition, the proposed technology could improve the accuracy of operation and the speed of rehabilitation.

경골 천정(pilon) 골절의 최신 치료 (Current Treatment of Tibial Pilon Fractures)

  • 이준영
    • 대한족부족관절학회지
    • /
    • 제15권2호
    • /
    • pp.51-57
    • /
    • 2011
  • Pilon fractures involving distal tibia remain one of the most difficult therapeutic challenges that confront the orthopedic surgeons because of associated soft tissue injury is common. To introduce and describe the diagnosis, current treatment, results and complications of the pilon fractures. In initial assessment, the correct evaluation of the fracture type through radiographic checkup and examination of the soft tissue envelope is needed to decide appropriate treatment planning of pilon fractures. Even though Ruedi and Allgower reported 74% good and excellent results with primary open reduction and internal fixation, recently the second staged treatment of pilon fractures is preferred to orthopedic traumatologist because of the soft tissue problem is common after primary open reduction and internal fixation. The components of the first stage are focused primarily on stabilization of the soft tissue envelope. If fibula is fractured, fibular open reduction and internal fixation is integral part of initial management for reducing the majority of tibial deformities. Ankle-spanning temporary external fixator is used to restore limb alignment and displaced intraarticular fragments through ligamentotaxis and distraction. And the second stage, definitive open reduction and internal fixation of the tibial component, is undertaken when the soft tissue injury has resolved and no infection sign is seen on pin site of external fixator. The goals of definitive internal fixation should include absolute stability and interfragmentary compression of reduced articular segments, stable fixation of the articular segment to the tibial diaphysis, and restoration of coronal, transverse, and sagittal plane alignments. The location, rigidity, and kinds of the implants are based on each individual fractures. The conventional plate fixation has more advantages in anatomical reduction of intraarticular fractures than locking compression plate. But it has more complications as infection, delayed union and nonunion. The locking compression plate fixation provides greater stability and lesser wound problem than conventional implants. But the locking compression plate remains poorly defined for intraarticular fractures of the distal tibia. Active, active assisted, passive range of motion of the ankle is recommended when postoperative rehabilitation is started. Splinting with the foot in neutral is continued until suture is removed at the 2~3 weeks and weight bearing is delayed for approximately 12 weeks. The recognition of the soft tissue injury has evolved as a critical component of the management of pilon fractures. At this point, the second staged treatment of pilon fractures is good treatment option because of it is designed to promote recovery of the soft tissue envelope in first stage operation and get a good result in definitive reduction and stabilization of the articular surface and axial alignment in second stage operation.

근위골절술을 위한 Staple 설계 (A Newly Designed Miniplate Staple for High Tibial Osteotomy)

  • 문무성;배대경
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1995년도 춘계학술대회
    • /
    • pp.19-22
    • /
    • 1995
  • A biomechanical study was made to demonstrate the superior mechanical performance of the newly designed Miniplate staple to the conventional Coventry staple in high tibial osteotomy(HTO). Using twenty fresh porcine tibiae, the fixational strengh of the two different types of staple in HTO was compared. To minimize the error due to the specimen-to-specimen individuality, the bone mineral density of the tibiae was measured with a bone densitometry (Dual photon absorptionometer, Luner, USA) and those with $0.8\;{\sim}\;1.2\;gm/cm^2$ at the proximal tibia was used in the biomechanical test. Testing was performed on a material testing system (Autogram ET-5, Shimatzu, Japan) with aid of a commercial data processor (IBM 80386/ ASYST). Using two differant loading modes, 'pull-out' and 'push-out', the maximum resistant force required to release the staple from the substrate bone was recorded. In the pull-out test, ten non-osteotomized specimens were used and the staple was pullout by subjecting an axial tension on the head of the staple inserted. While in the pull-out test where ten tibiae osteotomized in the usual way of HTO were used, the staple was not directly loaded. In this testing, as a mimic condition of the natural knee, the distal part of the specimen tibia was pushed horizontally in order for the staple to be pulled out while the proximal tibia was fixed. The pull-out strength of Coventry staple and miniplate staple were found to be $27.88\;{\pm}\;5.12\;kgf$ and $182.47\;{\pm}\;32.75\;kgf$, respectively. The push-out strength of Coventry staple and miniplate staple were $18.40\;{\pm}\;4.47\;kgf$ and $119.95\;{\pm}\;19.06\;kgf$, respectively. The result revealed that miniplate staple had the pull-out/ push-out strength at least fivetimes higher than Coventry staple. Based on the measured data, it was believed that the newly designed miniplate staple could provide much better postoperative fixation in HTO. The postoerative application of long leg casting may not be needed after HTO surgery.

  • PDF

Pathological fracture induced by Halicephalobus gingivalis (Nematoda: Rhabditida) in a horse limb

  • Ticiana Meireles Sousa;Hugo Shisei Toma;Antonio de Padua Lima;Antonio Carlos Cunha Lacreta Junior;Maira Meira Nunes;Ana Paula Cassiano da Silva;Daniel Wouters;Adriana Silva Albuquerque;Mary Suzan Varaschin;Djeison Lutier Raymundo;Claudia Dias Monteiro Toma;Fernando Arevalo Batista
    • Parasites, Hosts and Diseases
    • /
    • 제62권1호
    • /
    • pp.131-138
    • /
    • 2024
  • Halicephalobus gingivalis is a free-living nematode that occasionally causes infections in horses. We report a rare case of limb fracture of horse caused by infection with H. gingivalis. An 8-year-old mare was referred to the Veterinary Hospital of the Federal University of Lavras with claudication grade 5 of the right hind limb, that had been started 3 months ago. The patient had aseptic arthritis in the tarsal joint and edema that extended to the quartile. The radiographic examination showed punctate osteolysis with exacerbation of bone trabeculation along the calcaneus, talus, proximal epiphysis of the third metatarsal and distal epiphysis of the tibia. Treatment for arthritis was initiated, and the animal showed a slight improvement in limb function. However, 21 days after hospitalization, due to a comminuted fracture of the tibia, it was euthanized. At necropsy, yellowish masses were found from the metatarsal to the tibia, and around the tarsal bones and joint. Similar masses were also found in the left kidney. Numerous nematodes compatible with H. gingivalis were identified. This is the first description of a pathological fracture caused by H. gingivalis infection in an equine limb.