• 제목/요약/키워드: Distal clavicle fracture

검색결과 38건 처리시간 0.023초

원위 쇄골 골절에 대한 금속판 고정술 이후 발생된 견봉하 충돌 증후군 - 증례보고 - (Subacromial Impingement Syndrome following Hook Plate Fixation for Distal Clavicle Fracture -A Case Report-)

  • 문규필;강민수;최성종
    • 대한관절경학회지
    • /
    • 제15권1호
    • /
    • pp.19-21
    • /
    • 2011
  • 갈고리형 금속판(Clavicle Hook Plate)은 원위 쇄골 골절 및 견봉 쇄골 관절 손상 등 쇄골 주변부 손상에 대해 현재 널리 사용되고 있는 내고정물이다. 저자들은 원위 쇄골 골절에서 갈고리형 금속판을 이용한 내 고정술 후 발생된 견관절 충돌증후군 1 예를 경험하여 문헌 고찰과 함께 보고하는 바이다.

  • PDF

견봉 쇄골 탈구와 쇄골 외측단 골절에서 일시적 오구 쇄골간 나사못 고정술 (Coracoclavicular Screw Fixation for AC Dislocation and Unstable Distal Clavicle Fracture)

  • 김진섭;전진호;정영기
    • Clinics in Shoulder and Elbow
    • /
    • 제2권2호
    • /
    • pp.133-137
    • /
    • 1999
  • Purpose: There are so many different methods with the their own advantages and disadvantages for acute AC dislocation and distal unstable clavicle fracture. We evaluated the usefulness of temporary Bosworth's coracoclavicular fixations using the cannulated screw and reviewed our clinical results. Materials and Methods: We evaluated 34 cases of temporary coracoclavicular fixations with cannulated screw and washer for acute AC dislocation(25cases in the Type V, Ⅲ) and distal unstable clavicle fracture(9cases in the Type ⅡB, Ⅱ+Ⅲ). All cases were fixed by the same techniques, guided cannulated screw under C-arm after the repair of the CC ligament within 1 week. Bases on the regular check, screws were removed at the 6-12 weeks under local anesthesia. The final clinical and radiological results(average 14 months follow-up) were rated with the UCLA scale. Results : All shoulders were gained nearly full ROM passively at the 3-4 weeks. The overall satisfactory resuIts(excellent or good) were achieved 88%(22/25) in the acute AC dislocation and all in the distal unstable clavicle fracture. There were no definite complications except three initial fixations loosening. Conclusion: Temporary Bosworth's coracoclavicular fixation using the cannulated screw with guided pin was simple precedure and provided enough initial stability for acute AC dislocation and distal unstable clavicle fracture.

  • PDF

소아 쇄골 원위부 전위골절의치료- 2례보고- (Treatment of Displaced Fracture of the Distal Clavicle in Children- Report of 2 Cases)

  • 박태수;김종헌
    • 대한정형외과스포츠의학회지
    • /
    • 제1권2호
    • /
    • pp.159-162
    • /
    • 2002
  • 쇄골의원위부가상방전위되고오구쇄골간격이이완된소아의불안정한쇄골원위부골절2예에대하여보존적치료후오구쇄골간격이정상적으로회복되고완전한골유합을얻을수있었다. 소아의경우비록쇄골원위부의전위된불안정한골절이라도먼저보존적치료를반드시고려하여야할것으로사료된다.

  • PDF

Acromion Fracture after Hook Plate Fixation for Distal Clavicle Injury: A Report of 2 Cases

  • Kang, Suk;Lee, Ho Min;Back, In Hwa
    • Clinics in Shoulder and Elbow
    • /
    • 제19권3호
    • /
    • pp.168-171
    • /
    • 2016
  • Fractures at the lateral end of the clavicle inevitably require surgical treatment as there is high potential for delayed union or nonunion. Acromioclavicular dislocation also requires stable and solid fixation for healing, and surgical treatment is recommended for the maintenance of joint function. The hook plate maintains the biomechanics of the acromioclavicular joint, enabling early range of motion. Therefore, for the past 10 years, the hook plate has been widely used in distal clavicle fractures and acromioclavicular joint injuries. However, the hook plate is associated with several complications, such as proximal clavicle fractures, widening of the hook hole, rotator cuff tear, subacromial impingement, and often acromial fractures. We report on two unusual cases of acromion fracture after hook plate fixation in patients with distal clavicle fracture and acromioclavicular dislocation alongside a literature review.

The Radiologic Comparison of Operative Treatment Using a Hook Plate versus a Distal Clavicle Locking Plate of Distal Clavicle Fracture

  • Yoon, Byungil;Kim, Jae Yoon;Lee, Jae-Sung;Jung, Hyoung Seok
    • Clinics in Shoulder and Elbow
    • /
    • 제21권4호
    • /
    • pp.227-233
    • /
    • 2018
  • Background: The purpose of this study was to compare the radiologic results of patients who underwent surgery with a hook plate and a locking plate in distal clavicle fractures. Methods: Sixty patients underwent surgical treatment for Neer type IIa, IIb, III, and V distal clavicle fracture. Twenty-eight patients underwent fracture fixation with a hook plate and 32 with a locking plate. Coracoclavicular distance was measured on standard anteroposterior radiographs before and after the surgery, and union was confirmed by radiograph or computed tomography taken at 6 months postoperatively. Other radiologic complications like osteolysis was also checked. Results: Bony union was confirmed in 59 patients out of 60 patients, and 1 patient in the hook plate group showed delayed union. Coracoclavicular distance was decreased more in the hook plate group after surgery (p<0.01). After 6 weeks of the hook plate removal, the coracoclavicular distance was increased a little compared to before metal removal, but there was no difference compared to the contralateral shoulder. Eleven out of 28 patients (39.3%) showed osteolysis on the acromial undersurface in the hook plate group. Conclusions: Both the hook plate group and the locking plate group showed satisfactory radiologic results in distal clavicle fractures. Both hook plate and locking plate could be a good treatment option if it is used in proper indication in distal clavicle fracture with acromioclavicular subluxation or dislocation.

불안정한 Neer II형 원위쇄골 골절의 치료에서 Hook 금속판의 이용 (The Use of Hook Plate on the Management of Unstable Neer II Lateral End Fracture of The Clavicle)

  • 고상훈;조성도;박문수;류석우
    • Clinics in Shoulder and Elbow
    • /
    • 제6권2호
    • /
    • pp.131-137
    • /
    • 2003
  • Purpose: Unstable Neer type II lateral end fracture of clavicle may be required operation. The purpose of this study is the effectiveness of the use of Hook plate in the management of unstable Neer type II fractures. We preliminary reported the results of Unstable Neer type II lateral end fracture of clavicle using by Hook plate. Material and Methods: From May 1998 to May 2002, we operated 6 cases unstable Neer type II lateral end fracture of clavicle with Hook plate by one surgeon. We checked radiologic evaluation and disappearance of pain per 1 week, and evaluated improvement of range of motion per 2 week. And we followed up at each interval 3 months,6 months, 12 months and after that per 6months interval, at that each time we checked stress radiogram of shoulder and functional evaluation. The shoulder function was evaluated using Modified Shoulder Rating Scale (MSRC) for Distal Clavicle Fracture and UCLA score. Average follow up was on 37.2 (12∼57) months. Results: All 6 patients were regained satisfactory function. Average MSRC for distal clavicle fracture was 17.3 (15∼20) and average UCLA score was 33.2 (31∼35) at last follow up. Conclusion: There are many advantage of the use of Hook plate on management of unstable Neer II distal clavicle fracture in spite of several disadvantage. There have not yet been reported in our country. So we obtained good to excellent clinical result in surgical treatment of 6 cases on type II displaced lateral end fracture of the clavicle. But we think that more cases will be review and longer follow up will be needed in the future.

Unusual and nondescript type of distal clavicular fracture

  • Fernandez, Alberto Izquierdo;Minarro, Jose Carlos
    • Clinics in Shoulder and Elbow
    • /
    • 제24권2호
    • /
    • pp.106-109
    • /
    • 2021
  • Displaced fracture of the distal third of the clavicle usually occurs after direct trauma to the shoulder and typically results in superior displacement of the proximal fragment. We report a previously undescribed case of downward displacement of the clavicle caused by a fall on an outstretched hand, and we suggest the mechanism of injury.

후방으로 전위된 소아 쇄골 원위부 골절의 수술적 치료 - 1예 보고 - (Operative Treatment of Posteriorly Displaced Fracture of the Distal Clavicle in Child - A Case Report -)

  • 박현수;정태원;라종득;장영수;이병훈
    • Clinics in Shoulder and Elbow
    • /
    • 제9권2호
    • /
    • pp.207-210
    • /
    • 2006
  • We presented a case of posteriorly displaced fracture of the distal clavicle in Child. The closed reduction was failed due to posteriorly displaced proximal fragment and interpositon of trapezius muscle and periosteum. We found that periosteal sleeve and coracoclaviclar ligament and acromioclavicular ligament was intact. The open reduction should be considered for the treatment of the irreducible posteriorly displaced fracture of the distal clavicle in child.

Coracoclavicular Ligament Suture Augmentation with Anatomical Locking Plate Fixation for Distal Clavicle Fracture

  • Lim, Tae Kang;Shon, Min Soo;Ryu, Hyung Gon;Seo, Jae Sung;Park, Jae Hyun;Ko, Young;Koh, Kyoung-Hwan
    • Clinics in Shoulder and Elbow
    • /
    • 제17권4호
    • /
    • pp.175-180
    • /
    • 2014
  • Background: For Neer type IIB fracture of distal clavicle with coracoclavicular ligament injury, various surgical treatments have been used in literatures. However, there was no consensus on the optimal treatment. The aim of this study is to report the clinical and radiological results of open reduction and internal fixation of unstable distal clavicle fracture and suture augmentation of disrupted coracoclavicular ligament. Methods: A prospective study was performed in 23 patients with Neer type IIB distal clavicle fracture in Seoul Medical Center, Eulji Hospital, and National Medical Center. Firstly, suture anchors are inserted in the base of coracoid process and preliminary reduction was achieved by tie-off of three suture limbs around the clavicle. Then, the final fixation was completed with anatomical locking plate. Bony union and the distance between coracoclavicular ligaments were evaluated. Clinical results and complications including stiffness and secondary procedures were evaluated. Results: Bony union was achieved in all cases except one (22 of 23). At mean 14.9 months, no significant difference in the mean coracoclavicular distance was observed compared to uninjured shoulder ($8.2{\pm}7.9mm$ versus $7.3{\pm}3.4mm$, p=0.14). Pain visual analogue scale, American Shoulder and Elbow Surgeons score, Constant score, and Disabilities of the Arm, Shoulder and Hand score were 0.5, 83.4, 78.5, and 6.2, respectively. Revision surgery was performed in one case of nonunion. Four patients who complained of skin irritation underwent implant removal. Conclusions: In cases of an unstable distal clavicle fracture with coracoclavicular ligament disruption, satisfactory clinical results were obtained by locking plate fixation and coracoclavicular ligament suture augmentation concurrently.

Arthroscopic Stabilization for Displaced Lateral Clavicular Fractures: Can It Restore Anatomy?

  • Khan, Prince Shanavas;Yoo, Yon-Sik;Kim, Byung-Su;Lee, Seong-Jin;Ha, Jong Mun
    • Clinics in Shoulder and Elbow
    • /
    • 제19권3호
    • /
    • pp.143-148
    • /
    • 2016
  • Background: The purpose of our study was to evaluate the accuracy of reduction based on postoperative computed tomography (CT) images after arthroscopic stabilization using tightrope system for unstable distal clavicle fracture. Methods: Twelve patients with distal clavicle fracture combined with coracoclavicular (CC) ligament injury (type II, V) who received arthroscopically assisted fixation using a flip button device were evaluated for accuracy of reduction using 3-dimensional postoperative CT scan by measuring the degree of distal clavicular angulation and clavicular shortening. Results: Immediate postoperative plain radiograph confirmed restoration of the CC distance (CCD) in 10 patients. At final follow-up, the CCD remained reduced anatomically on plain radiographs in these patients. All patients showed excessive posterior angulation and shortening compared to the opposite side. The average Constant score recovered to 94.8 at final follow-up. Conclusions: Indirect reduction and arthroscopic subacromial approach with flip button fixation of unstable distal clavicle fractures demonstrated favorable clinical results despite unavoidable posterior angulation of distal clavicle and shortening the total length of clavicle.