• Title/Summary/Keyword: Dissolved oxygen control

Search Result 191, Processing Time 0.025 seconds

Control of Both Foam and Dissolved Oxygen in the Presence of a Surfactant for Production of $\beta$-Carotene in Blakeslea trispora

  • Kim, Seon-Won;Lee, In-Young;Jeong, Jae-Cheol;Lee, Jung-Heon;Park, Young-Hoon
    • Journal of Microbiology and Biotechnology
    • /
    • v.9 no.5
    • /
    • pp.548-553
    • /
    • 1999
  • A production of $\beta-Carotene$was attempted in a fed-batch culture of Blakeslea trispora by controlling both foam and dissolved oxygen in the presence of surfactant, Span 20. Results obtained from the shake flask cultures indicated that a high concentration of dissolved oxygen was needed for both cell growth and $\beta-Carotene$ synthesis, and the optimal concentration of glucose was found to be in the range of 50-100 g/l. In order to maintain the dissolved oxygen concentration level at higher than 50% of air saturation, pure oxygen was automatically sparged into the medium with air. Foam was controlled by bypassing air from the submerged aeration to the headspace in response to the foam that was caused by Span 20. High agitation speed was found to be detrimental to the cell growth due to shear damage, even though it provided sufficient dissolved oxygen. On the other hand, a low aeration speed caused stagnant regions in the fermentor because of improper mixing. Thus, for the fed-batch operation, agitation speed was increased gradually from 300 to 700 rpm to prevent cell damage at the initial stage of fermentation and to give efficient mixing for a viscous culture broth as the culture proceeded. By controlling dissolved oxygen and foam, a high concentration of $\beta-Carotene$otene (1,190 mg/l) was obtained in 6 days of the fed-batch culture of B. trispora with 2.5% of the dry cell weight, which was approximately 5 times higher than that of the batch cultures.

  • PDF

Fuzzy algorithm of Automatic control for dissolved oxygen in Activated sludge aeration tank (활성슬러지 폐수처리장 폭기조 DO제어를 위한 퍼지 제어 알고리즘 연구)

  • 손건태;김성덕;고주형
    • Journal of Environmental Science International
    • /
    • v.8 no.4
    • /
    • pp.533-538
    • /
    • 1999
  • Fuzzy algorithm of automatic control for dissolved oxygen(DO) concentration in the aeration tank of an activated sludge process is proposed. Among variables repirometry and air flowrate are selected as significant input factors and the relationship with DO is estimated using a multiple regression model. The DO concentration and the amount of repirometry are fuzzified and the fuzzy rule base are determined. Using the fuzzy algorithm, the change of amount of air flowrate are determined and the change of amount of DO is derived.

  • PDF

Effect and Development of Automatic Control of Dissolved Oxygen on Growth of Phellinus linteus WI-001 (Phellinus linteus WI-001 균사체의 성장에 미치는 용존산소농도의 영향 및 자동 조절방법 개발)

  • 김종래;권호균;전계택;이계관
    • Microbiology and Biotechnology Letters
    • /
    • v.28 no.5
    • /
    • pp.285-290
    • /
    • 2000
  • The effects of dissolved oxy-gen(DO) concentration and DO control modes on cell growth in a 4L computer-controlled bioreactor system were investigated using Phellinus linteus WI-001, a producer of protein-polysaccharides having potent anticancer activi-ties. When DO was controlled at about 20%, maximum cell concentration and specific growth rate of the strain were observed to increase 36% and 64%, respectively, as compared to the experiment performed without DO control. By adopting cascade automatic control of DO ar 20% in a mixed automatic control mode using computer-con-trolled program, 19.5g/L of maximum cell concentration was obtained. These results showed that the mixed auto-matic control mode was the effective method for enhancing cell growth of the shear sensitive Phellinus linteus.

  • PDF

Urban Streams' Water Quality and Odor Control Using Pure Oxygen and Vortex Aerator (순산소와 Vortex Aerator를 이용한 도심하천의 수질 및 악취 관리)

  • Yoon, Dain;Choi, Mijeong;Park, Sunghyuk
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.41 no.5
    • /
    • pp.493-504
    • /
    • 2021
  • The target site, Goejeongcheon flows through downtown of Saha-gu, Busan and it connects to the Nakdong-gang estuary. But non-point pollutants and sewage sludge are partially flowing into the stream and deposited. As a result, dissolved oxygen concentrations of the stream were observed close to the anaerobic condition. Multistage Vortex Aerator was applied for restoring this urban stream. It dissolves oxygen by repeatedly causing collisions between water and oxygen by vortex flow. The changes in water quality and odor were monitored for 2 months while circulating 1 m3/min of water with 22 ppm dissolved oxygen. As a result of the operation, the dissolved oxygen was improved from slightly Bad (4)~Bad (5) to Good (1b)~Normal (3) grade, and the total phosphorus concentration was decreased by 76 % on average. In the case of complex odor, a maximum reduction of 84.5 % was observed on the day the entire river was anaerobic. Through this study, we evaluated the feasibility of applying pure oxygen and Vortex Aerator for the the stream restoration. It is expected that the results of this study can be used for full-scale design.

용존산소농도 조절에 의한 미생물 유래 Transglutaminasc 생산

  • Yu, Jae-Su;Jeon, Gye-Taek;Sin, Won-Seon;Jeong, Yong-Seop
    • 한국생물공학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.343-346
    • /
    • 2001
  • The effect of agitation speed and aeration rate on mTG production and cell growth by Streptoverticillum morbarense was investigated. Dissolved oxygen was controlled by on-line computer-controlled fermentation system. The agitation speed and aeration rate of 2.5 L fermentor ranged from 330 to 360 게m and 1 vvm to 4 vvm, respectively. The highest mTG production was 2.1 U/mL when dissolved oxygen level was 20%, and it was improved almost 1.1 times in comparison with that without dissolved uxygen control.

  • PDF

An Implementation of System for Control of Dissolved Oxygen and Temperature in the pools of Smart Fish Farm (스마트 양식장 수조 내 용존 산소 및 온도 제어를 위한 시스템 구현)

  • Jeon, Joo-Hyeon;Lee, Yoon-Ho;Lee, Na-Eun;Joo, Moon G.
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.16 no.6
    • /
    • pp.299-305
    • /
    • 2021
  • Dissolved oxygen, pH, and temperature are the most important factors for fish farming because they affect fish growth and mass mortality of the fish. Therefore, fish farm workers must always check all pools on the farm, but this is very difficult in reality. That's why we developed a control system for smart fish farms. This system includes a gateway, sensor gatherers, and a PC program using LabVIEW. One sensor gatherer can cover up to four pools. The sensor gatherers are connected to the gateway in the form of a bus. For the gateway, the ATmega2560 is used as the main processor for communication and the STM32F429 is used as a sub-processor for displaying LCD. For the sensor gatherer, ATmega2560 is used as the main processor for communication. MQTT (Message Queuing Telemetry Transport), RS-485, and Zigbee are used as the communication protocols in the control system. The users can control the temperature and the dissolved oxygen using the PC program. The commands are transferred from the PC program to the gateway through the MQTT protocol. When the gateway gets the commands, it transfers the commands to the appropriate sensor gatherer through RS-485 and Zigbee.

Comparison of Proportional, Integral, and P-I Control Systems in Biological Wastewater Treatment Plants (생물학적 하수처리시스템에 적용된 Proportional, Integral 및 P-I 조절 시스템에 대한 비교)

  • Kim, Sungpyo
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.4
    • /
    • pp.410-415
    • /
    • 2005
  • The main purpose of this study is to evaluate the characteristics of three sets of traditional control methods (proportional, integral, and proportional - integral controls) through lab-scale biological reactor experiments. An increase in proportional gain ($K_c$) resulted in reduced dissolved oxygen (DO) offset under proportional control. An increase in integral time ($T_i$) resulted in a slower response in DO concentration with less oscillation, but took longer to get to the set point. P-I control showed more stable and efficient control of DO and airflow rates compared to either proportional control or integral control. Developed P-I control system was successfully applied to lab-scale Sequencing Batch Reactor (SBR) for treating industrial wastewater with high organic strength.

The Characteristics of Water Quality in Mokpo Harbour(I) - Centering on organic pollution and dissolved oxygen in summer- (목포항의 수질 특성(I) - 하계의 유기물 오염과 용존산소를 중심으로 -)

  • 김광수
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.3 no.1
    • /
    • pp.99-109
    • /
    • 1997
  • The in situ observations and the seawater analyses were conducted in July and August, 1996 for the purpose of describing the characteristics of organic pollution, dissolved oxygen distributions, and the evaluation of water quality in Mokpo harbour. The vertical density distribution of water column was found to be in stable structure with higher water temperature and lower salinity on surface layer at ebb tide in summer. In July, dissolved oxygen was shown to be oversaturated on surface and bottom layers, while in August, which was shown to be oversaturated on surface layer, and to be unsaturated on bottom layer as 68∼93% of saturation percentage. Dissolved oxygen of bottom layer in August was evaluated to be under the regular grades, based on Korean standards of seawater quality. In view of COD, the seawater quality of Mokpo harbour in summer was evaluated to be deteriorated due to organic wastes and graded to be the third class, and TSS of Mokpo harbour in summer was graded to be the second class, based on Korean standards of seawater quality. In particular, COD of surface layer in August was found to be under the regular grades. It is, therefore, necessary to take measures for the control of pollution loads and the proper management of seawater quality in Mokpo harbour. The distribution patterns of DO, COD, VSS and Chlorophyll-a on surface layer along the downstream center line from inner harbour to harbour entrance were similar to one another at ebb tide in August.

  • PDF

Adaptive Control of Denitrification by the Extended Kalman Filter in a Sequencing Batch Reactor (확장형칼만필터에 의한 연속회분식반응조의 탈질 적응제어)

  • Kim, Dong Han
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.6
    • /
    • pp.829-836
    • /
    • 2006
  • The reaction rate of denitrification is primarily affected by the utilization of organics that are usually limited in the anoxic period in a sequencing batch reactor. It is necessary to add an extemal carbon source for sufficient denitrification. An adaptive model of state-space based on the extended Kalman filter is applied to manipulate the dosage rate of extemal carbon automatically. Control strategies for denitrification have been studied to improve control performance through simulations. The normal control strategy of the constant set-point results in the overdosage of external carbon and deterioration of water quality. To prevent the overdosage of external carbon, improved control strategies such as the constrained control action, variable set-point, and variable set-point after dissolved oxygen depletion are required. More stable control is obtained through the application of the variable set-point after dissolved oxygen depletion. The converging value of the estimated denitrification coefficient reflects conditions in the reactor.

3 Types of Set Point Controllers for Biological Wastewater Treatment Process

  • Kim, D.;Lee, I.B.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.97.1-97
    • /
    • 2001
  • One of the main problems to constitute control method on biologically oriented wastewater purification processes, e.g. activated sludge process, sequential batch reactor, rotating bio-disk contactor, etc. is that it is hard to control the target component directly. For instance, while biochemical oxygen demand, suspended solids, and chemical oxygen demand are the key components to check the process performance, one may not control them directly since they are the results of microbial activities related to numerous physiochemical factors. Therefore controllers for bioprocess should be designed to make favorable condition for microorganisms´ living, e.g. dissolved oxygen level favorable, mixed liquor suspended solids concentration suitable ...

  • PDF