• Title/Summary/Keyword: Dissolved oxygen (DO)

Search Result 483, Processing Time 0.026 seconds

Design and Fabrication of Portable Dissolved Oxygen Measurement System (휴대용 용존산소 측정 시스템의 설계 및 제작)

  • Chang, Choong-Won;Lee, Sung-Pil
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.9 no.3
    • /
    • pp.219-223
    • /
    • 2008
  • The dissolved oxygen (DO) sensors were fabricated by screen printing method, and potable dissolved oxygen measurement system was fabricated for low cost products. The fabricated sensors had high current change and fast response according to dissolved oxygen concentrations in the applied voltage of 0.7 V. The DO measurement system was consisted of MCV, amplifier, filter, power supply and display. DO concentrations were programed to display as digital percentages by converting the analog value. It is expected that the fabricated DO measurement system can replace the expensive commercial DO meter, because it reveals the high accuracy of ${\pm}0.5%$ to the standard solution and the response time of about 100 sec like the commercial DO meter.

  • PDF

Early Summer Dissolved Oxygen Characteristics in Restored Streams in Seoul (서울시 복원하천들의 초여름 용존 산소량 특성 분석)

  • Thoenen, Casey;Choi, Woonsup;Choi, Jinmu
    • Journal of the Korean Geographical Society
    • /
    • v.48 no.3
    • /
    • pp.336-347
    • /
    • 2013
  • This paper presents an evaluation of stream restoration projects in Seoul with a focus on dissolved oxygen. Five test sites across four streams were measured for dissolved oxygen (DO) in late May to early June in 2012 and compared against a set of minimum and maximum thresholds. Only one test site, Hwarang-cheon, showed measurements below 6 mg/l DO. Towards the upper limit, the Hwarangcheon site was the only tested stream which was not at risk of DO supersaturation. The Danghyeon-cheon site had the highest probability of supersaturation, with DO saturation exceeding 130% expected 86.5% of the time. When measured every hour during daytime, DO levels showed diurnal variations, peaking in the afternoon. However, they showed inconsistent results along transects of the streams. Overall, the streams are rich in DO. To maintain the streams in good standing, nutrient loading should be addressed to prevent potential algal bloom induced hypoxic events down the line.

  • PDF

Removal of Dissolved Oxygen from the Make-up Water of NPP Using Membrane-based Oxygen Removal System

  • Chung, Kun-Ho;Kang, Duck-Won;Hong, Sung-Yull
    • Nuclear Engineering and Technology
    • /
    • v.31 no.6
    • /
    • pp.541-547
    • /
    • 1999
  • Corrosion control, in the end-shield cooling system of Wolsung Nuclear Power Plant, is directly related to the control of dissolved oxygen (DO). The current method, being used to deoxygenate the end-shield cooling water, is a chemical treatment by addition of reducing agent, hydrazine, to react with DO. This method has several limitations including high reaction temperature of hydrazine , unwanted explosive hydrogen gas production, and its intrinsic harmful property. A new approach to remove DO using a membrane-based oxygen removal system (MORS) was tried to overcome limitations of the hydrazine treatment. The DO removal efficiency of the MORS was found to be in the range 87% to 98%: The higher vacuum, the lower water flow rate and the higher water temperature tend to increase the DO removal efficiency.

  • PDF

Extent and persistence of dissolved oxygen enhancement using nanobubbles

  • Tekile, Andinet;Kim, Ilho;Lee, Jai-Yeop
    • Environmental Engineering Research
    • /
    • v.21 no.4
    • /
    • pp.427-435
    • /
    • 2016
  • In this study, change in water-dissolved oxygen (DO) was analyzed under various synthetic water qualities and nanobubbles (NBs) application conditions, such as gas type, initial DO as well as water dissolved, suspended and organic matters contents. When oxygen, rather than air, was introduced into nitrogen-desorbed ultra-pure water, the stagnation time was significantly increased. It took ten days for DO concentration to drop back to saturation. The higher the initial DO concentration, the longer particles were observed above saturation due to particle stability improvement. The oxygen mass transfer rate of 0.0482 mg/L/min was found to reach a maximum at an electrolytic concentration of 0.75 g/L, beyond which the transfer rate decreased due to adsorption of negative ions of the electrolyte at the interface. High levels of turbidity caused by suspended solids have become a barrier to dissolution of NBs oxygen into the water solution, and thus affected the transfer performance. On the other hand, by applying NBs for just an hour, up to 7.2% degradation of glucose as representative organic matter was achieved. Thus, NBs technology would maintain a high DO extent for an extended duration, and thus can improve water quality provided that water chemistry is closely monitored during its application.

Monitoring bridge scour using dissolved oxygen probes

  • Azhari, Faezeh;Scheel, Peter J.;Loh, Kenneth J.
    • Structural Monitoring and Maintenance
    • /
    • v.2 no.2
    • /
    • pp.145-164
    • /
    • 2015
  • Bridge scour is the predominant cause of overwater bridge failures in North America and around the world. Several sensing systems have been developed over the years to detect the extent of scour so that preventative actions can be performed in a timely manner. These sensing systems have drawbacks, such as signal inaccuracy and discontinuity, installation difficulty, and high cost. Therefore, attempts to develop more efficient monitoring schemes continue. In this study, the viability of using optical dissolved oxygen (DO) probes for monitoring scour depths was explored. DO levels are very low in streambed sediments, as compared to the standard level of oxygen in flowing water. Therefore, scour depths can be determined by installing sensors to monitor DO levels at various depths along the buried length of a bridge pier or abutment. The measured DO is negligible when a sensor is buried but would increase significantly once scour occurs and exposes the sensor to flowing water. A set of experiments was conducted in which four dissolved oxygen probes were embedded at different soil depths in the vicinity of a mock bridge pier inside a laboratory flume simulating scour conditions. The results confirmed that DO levels jumped drastically when sensors became exposed during scour hole evolution, thereby providing discrete measurements of the maximum scour depth. Moreover, the DO probes could detect any subsequent refilling of the scour hole through the deposition of sediments. The effect of soil permeability on the sensing response time was also investigated.

Dissolved Oxygen Trend in Sapgyo Stream Watershed (삽교천유역의 용존산소 추세)

  • Rim, Chang-Soo
    • Journal of Korea Water Resources Association
    • /
    • v.46 no.6
    • /
    • pp.667-681
    • /
    • 2013
  • In this study, monthly and seasonal dissolved oxygen trends of 19 water quality measurement stations in Sapgyo stream watershed were analyzed using monthly dissolved oxygen (DO) data measured for 16 years (1995~2010). Mann-Kendall trend test and Sen's slope estimator were carried out for trend analysis. Furthermore, Sapgyo stream watershed was divided into four different sections (Sapgyo stream, Muhan stream, Gykgyo stream, and Sapgyo lake) and chi-square test of homogeneity for DO trend was carried out for four different sections. The study results indicated that most of water quality measurement stations showed increasing or non-significant trend of DO on a monthly and seasonal basis. The chi-square test of homogeneity for each water quality measurement station showed the statistical homogeneity in seasonal DO trend; however, the test results showed the statistical non-homogeneity in monthly DO trend for the stations located in the reservoir. Overall, the dissolved oxygen trend in each water quality measurement station showed different patterns depending on the location of each station and season.

The Effect of Dissolved Oxygen and Salinity on Oxygen Consumption and Ammonia Excretion in the Mysid, Neomysis awatschensis (곤쟁이 (Neomysis awatschensis)의 산소소비와 질소배설에 미치는 염분 및 용존산소의 영향)

  • SHIN Yun Kyung;LEE Jung Ah;CHIN Pyung
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.33 no.2
    • /
    • pp.110-114
    • /
    • 2000
  • Effects of the combinations of six oxygen concentrations ($control, 0.6, 1.0, 2.0, 3.4 and 7.4 mg DO/l$) and two salinity levels ($20{\%_{\circ}} and 32{\%_{\circ}}$) on the rates of oxygen consumption, ammonia excretion and mortality of the mysid, Neomysis awatschensis were tested at $20{\circ}C$. The lethal level ($96 hr-LC-(50)$) of dissolved oxygen for mysid at $20{\%_{\circ}} and 32{\%_{\circ}} were 2,20 mg DO/l and 1.60 mg DO/l$ respectively, and all mysids died within $24hr at 0.6 mg DO/l$. Oxygen consumption rate of mysid was increased with dissolved oxygen increase at $20{\%_{\circ}} and 32{\%_{\circ}}$, but ammonia excretion rate was high af $1.0 mg DO/l$ during 96h exposure to DO concentration, and significantly greater in $20{\%_{\circ}} than 32{\%_{\circ}}$. $O:N$ ratio of mysid exposed during 96hr with salinity anil dissolved oxygen was below $10 at 20{\%_{\circ}} and 1,0{\~}2.0 mg DO/l, and was 4.4 at 32{\%_{\circ}} and 1.0 mg DO/l$. These results indicated that mysids were capable of changing their energy substrate in response to salinity and DO changes, and obtaining energy from proteins.

  • PDF

A Study on the Releasing Characteristics of Organic Matter and Heavy Metals and Changes of Dissolved Oxygen Concentration during Sediment Resuspension (퇴적물 재부유에 따른 유기물과 중금속 용출 및 용존산소량 변화 특성에 대한 연구)

  • Kang, Seon Gyeong;Lee, Han Saem;Lim, Byung Ran;Rhee, Dong Seok;Shin, Hyun Sang
    • Journal of Korean Society on Water Environment
    • /
    • v.37 no.1
    • /
    • pp.1-9
    • /
    • 2021
  • The depletion of dissolved oxygen (DO) in urban streams has a profound effect on the aquatic ecosystem; however, the change in DO by resuspension of sediments and the cause have not been sufficiently investigated. In this study, the physicochemical properties (particle size, and the content of organic and heavy metals) of the sediments of an urban stream (Anyang Stream) and the characteristics of water quality changes (DO, dissolved organic carbon (DOC), dissolved nitrogen (DN), sediment oxygen demand (SOD), and adenosine triphosphate (ATP)) by sediment resuspension were investigated. The sediment content of fine particles (< 0.2 mm) increased from 36.7% to 52.7% from the upstream to the downstream, and the contents of heavy metals and organic matter of the sediment were also higher towards the downstream. The depletion of DO by resuspension was observed in the sediment at the downstream sites (P8, P9), where the fine particle content was high, and biological SOD (BSOD) was more than 88% compared to the total SOD. The increase in BSOD coincided with the increase in ATP. It was also confirmed that the depletion of DO could increase the amount of heavy metals (such as Fe, Mn, and Pb) released from the sediment. Based on the above results, it can be concluded that resuspension of sediments induces rapid water quality changes and may cause accidents, such as fish mortality, during rainfall, and such a water quality effect can be more pronounced in sediments with a high content of fine particles and organic matter and high biological activity.

Development and Applications of an Optic Oxygen Sensor Datalogger for in situ Dissolved Oxygen Monitoring in Coastal Water (연안 용존산소 현장 모니터링용 산소광센서 데이터로거 개발 및 적용)

  • Jae Seong, Lee;Hyunmin Baek
    • Ocean and Polar Research
    • /
    • v.45 no.2
    • /
    • pp.33-42
    • /
    • 2023
  • Dissolved oxygen (DO) is a crucial parameter for assessing environmental conditions in aquatic ecosystems. However, commercial in situ dataloggers for oxygen optodes can be relatively expensive and limited in their specifications. In this paper, we present a novel design for a DO datalogger system based on the control boards family with RP2040 MCU chipset. Our design includes two types of dataloggers: a simple logging system and a programmable system for sampling rates via magnetic switches underwater for divers. We provide detailed descriptions of the system, including the MicroPython source code and drawings to aid in construction. We also discuss the various applications of our DO datalogger system in monitoring dissolved oxygen concentration in coastal waters and assessing the benthic metabolism of aquatic ecosystems. Our DO datalogger system provides an affordable and flexible option for researchers to accurately monitor DO concentrations in aquatic environments, and thereby improve our understanding of these complex ecosystems.

Feedback Control of Dissolved Oxygen with Hardware Modification of Fermenter (발효기 하드웨어 변환을 이용한 용존산소 제어)

  • 이중헌;이인영;박영훈
    • KSBB Journal
    • /
    • v.15 no.3
    • /
    • pp.280-284
    • /
    • 2000
  • The simple imcroprocessor device was provided for the control of dissolved oxygen(DO) level. The DO analog signal output from fementer was used as a measurement variable and the agitation speed of fermenter was used as a manipulatio variable. Agitation speed was manipulated to maintain DO level above 10% of saturation condition during cell growth period with microprocessor. Since the experimental resultsshowed that the DO level was maintained above 10% and agitation speed was inverse proportional to DO level ithis simple control device can be used for the DO control of fermenter.

  • PDF