• Title/Summary/Keyword: Dissolved Oxygen (DO) Control

Search Result 98, Processing Time 0.031 seconds

Feedback Control of Dissolved Oxygen with Hardware Modification of Fermenter (발효기 하드웨어 변환을 이용한 용존산소 제어)

  • 이중헌;이인영;박영훈
    • KSBB Journal
    • /
    • v.15 no.3
    • /
    • pp.280-284
    • /
    • 2000
  • The simple imcroprocessor device was provided for the control of dissolved oxygen(DO) level. The DO analog signal output from fementer was used as a measurement variable and the agitation speed of fermenter was used as a manipulatio variable. Agitation speed was manipulated to maintain DO level above 10% of saturation condition during cell growth period with microprocessor. Since the experimental resultsshowed that the DO level was maintained above 10% and agitation speed was inverse proportional to DO level ithis simple control device can be used for the DO control of fermenter.

  • PDF

Removal of Dissolved Oxygen from the Make-up Water of NPP Using Membrane-based Oxygen Removal System

  • Chung, Kun-Ho;Kang, Duck-Won;Hong, Sung-Yull
    • Nuclear Engineering and Technology
    • /
    • v.31 no.6
    • /
    • pp.541-547
    • /
    • 1999
  • Corrosion control, in the end-shield cooling system of Wolsung Nuclear Power Plant, is directly related to the control of dissolved oxygen (DO). The current method, being used to deoxygenate the end-shield cooling water, is a chemical treatment by addition of reducing agent, hydrazine, to react with DO. This method has several limitations including high reaction temperature of hydrazine , unwanted explosive hydrogen gas production, and its intrinsic harmful property. A new approach to remove DO using a membrane-based oxygen removal system (MORS) was tried to overcome limitations of the hydrazine treatment. The DO removal efficiency of the MORS was found to be in the range 87% to 98%: The higher vacuum, the lower water flow rate and the higher water temperature tend to increase the DO removal efficiency.

  • PDF

Fuzzy algorithm of Automatic control for dissolved oxygen in Activated sludge aeration tank (활성슬러지 폐수처리장 폭기조 DO제어를 위한 퍼지 제어 알고리즘 연구)

  • 손건태;김성덕;고주형
    • Journal of Environmental Science International
    • /
    • v.8 no.4
    • /
    • pp.533-538
    • /
    • 1999
  • Fuzzy algorithm of automatic control for dissolved oxygen(DO) concentration in the aeration tank of an activated sludge process is proposed. Among variables repirometry and air flowrate are selected as significant input factors and the relationship with DO is estimated using a multiple regression model. The DO concentration and the amount of repirometry are fuzzified and the fuzzy rule base are determined. Using the fuzzy algorithm, the change of amount of air flowrate are determined and the change of amount of DO is derived.

  • PDF

Effect and Development of Automatic Control of Dissolved Oxygen on Growth of Phellinus linteus WI-001 (Phellinus linteus WI-001 균사체의 성장에 미치는 용존산소농도의 영향 및 자동 조절방법 개발)

  • 김종래;권호균;전계택;이계관
    • Microbiology and Biotechnology Letters
    • /
    • v.28 no.5
    • /
    • pp.285-290
    • /
    • 2000
  • The effects of dissolved oxy-gen(DO) concentration and DO control modes on cell growth in a 4L computer-controlled bioreactor system were investigated using Phellinus linteus WI-001, a producer of protein-polysaccharides having potent anticancer activi-ties. When DO was controlled at about 20%, maximum cell concentration and specific growth rate of the strain were observed to increase 36% and 64%, respectively, as compared to the experiment performed without DO control. By adopting cascade automatic control of DO ar 20% in a mixed automatic control mode using computer-con-trolled program, 19.5g/L of maximum cell concentration was obtained. These results showed that the mixed auto-matic control mode was the effective method for enhancing cell growth of the shear sensitive Phellinus linteus.

  • PDF

The Effect of Dissolved Oxygen on Microbial Transglutaminase production by Streptoverticillium morbaraense (용존산소 농도 조절이 미생물유래 Transglutaminase 생산에 미치는 영향)

  • 유재수;전계택;정용섭
    • KSBB Journal
    • /
    • v.18 no.2
    • /
    • pp.155-160
    • /
    • 2003
  • The effect of dissolved oxygen(DO) on microbial transglutaminase(mTG) production by Streptoverticillium morbaraense was studied in on-line computer controlled fermentation system. In order to control dissolved oxygen during fermentation, the agitation speed and aeration rate of 2.5 L fermenter ranged from 260 to 360 rpm and 0.3 to 3.9 L/min, respectively. The maximum microbial transglutaminase production was obtained at controlled 20% of dissolved oxygen among the various dissolved oxygen controlled batch cultures tested. The production of microbial transglutaminase at controlled 20% of dissolved oxygen was about 2.12 U/mL which was 1.1 times higher than that obtained in batch culture without control of dissolved oxygen. Also, the highest microbial transglutaminase production was obtained in fed-batch cultures in which dissolved oxygen was controlled at 20%, and it was improved almost 1.3 times in comparison with that without control of dissolved oxygen. Maximal dry cell weight and microbial transglutaminase production were 13.2 g/L and 2.6 U/mL, respectively. Finally, it was also found that fed-batch fermentation at controlled 20% of dissolved oxygen showed a good performance for the microbial transglutaminase production by on-line computer controlled fermentation system which may be generally applicable to other microbial cultures.

Development and Applications of an Optic Oxygen Sensor Datalogger for in situ Dissolved Oxygen Monitoring in Coastal Water (연안 용존산소 현장 모니터링용 산소광센서 데이터로거 개발 및 적용)

  • Jae Seong, Lee;Hyunmin Baek
    • Ocean and Polar Research
    • /
    • v.45 no.2
    • /
    • pp.33-42
    • /
    • 2023
  • Dissolved oxygen (DO) is a crucial parameter for assessing environmental conditions in aquatic ecosystems. However, commercial in situ dataloggers for oxygen optodes can be relatively expensive and limited in their specifications. In this paper, we present a novel design for a DO datalogger system based on the control boards family with RP2040 MCU chipset. Our design includes two types of dataloggers: a simple logging system and a programmable system for sampling rates via magnetic switches underwater for divers. We provide detailed descriptions of the system, including the MicroPython source code and drawings to aid in construction. We also discuss the various applications of our DO datalogger system in monitoring dissolved oxygen concentration in coastal waters and assessing the benthic metabolism of aquatic ecosystems. Our DO datalogger system provides an affordable and flexible option for researchers to accurately monitor DO concentrations in aquatic environments, and thereby improve our understanding of these complex ecosystems.

Effect of Salinity on Dissolved Oxygen Characteristics in an Ejector-Aerator (이젝터-폭기 시스템의 용존산소특성에 미치는 염도의 영향)

  • Yang, Hei-Cheon;Park, Sang-Kyoo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.5
    • /
    • pp.640-646
    • /
    • 2011
  • Dissolved oxygen (DO) refers to the volume of oxygen that is contained in water, and is a major indicator of water quality. The objective of this paper was to investigate the effect of salinity on the dissolved oxygen characteristics in an ejector-aerator. An experimental aeration system composed of a motor-pump, an ejector, a motor-blower, a set of aeration and recirculation tank and a control panel. The dissolved oxygen concentrations decreased with the water salinity. The volumetric mass transfer coefficient increased with increasing the water salinity.

Comparison of Proportional, Integral, and P-I Control Systems in Biological Wastewater Treatment Plants (생물학적 하수처리시스템에 적용된 Proportional, Integral 및 P-I 조절 시스템에 대한 비교)

  • Kim, Sungpyo
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.4
    • /
    • pp.410-415
    • /
    • 2005
  • The main purpose of this study is to evaluate the characteristics of three sets of traditional control methods (proportional, integral, and proportional - integral controls) through lab-scale biological reactor experiments. An increase in proportional gain ($K_c$) resulted in reduced dissolved oxygen (DO) offset under proportional control. An increase in integral time ($T_i$) resulted in a slower response in DO concentration with less oscillation, but took longer to get to the set point. P-I control showed more stable and efficient control of DO and airflow rates compared to either proportional control or integral control. Developed P-I control system was successfully applied to lab-scale Sequencing Batch Reactor (SBR) for treating industrial wastewater with high organic strength.

The Effect of Dissolved Oxygen and Salinity on Oxygen Consumption and Ammonia Excretion in the Mysid, Neomysis awatschensis (곤쟁이 (Neomysis awatschensis)의 산소소비와 질소배설에 미치는 염분 및 용존산소의 영향)

  • SHIN Yun Kyung;LEE Jung Ah;CHIN Pyung
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.33 no.2
    • /
    • pp.110-114
    • /
    • 2000
  • Effects of the combinations of six oxygen concentrations ($control, 0.6, 1.0, 2.0, 3.4 and 7.4 mg DO/l$) and two salinity levels ($20{\%_{\circ}} and 32{\%_{\circ}}$) on the rates of oxygen consumption, ammonia excretion and mortality of the mysid, Neomysis awatschensis were tested at $20{\circ}C$. The lethal level ($96 hr-LC-(50)$) of dissolved oxygen for mysid at $20{\%_{\circ}} and 32{\%_{\circ}} were 2,20 mg DO/l and 1.60 mg DO/l$ respectively, and all mysids died within $24hr at 0.6 mg DO/l$. Oxygen consumption rate of mysid was increased with dissolved oxygen increase at $20{\%_{\circ}} and 32{\%_{\circ}}$, but ammonia excretion rate was high af $1.0 mg DO/l$ during 96h exposure to DO concentration, and significantly greater in $20{\%_{\circ}} than 32{\%_{\circ}}$. $O:N$ ratio of mysid exposed during 96hr with salinity anil dissolved oxygen was below $10 at 20{\%_{\circ}} and 1,0{\~}2.0 mg DO/l, and was 4.4 at 32{\%_{\circ}} and 1.0 mg DO/l$. These results indicated that mysids were capable of changing their energy substrate in response to salinity and DO changes, and obtaining energy from proteins.

  • PDF

Control of the Dissolved Oxygen Concentration in the Aeration Using Genetic Algorithms (유전 알고리즘을 이용한 폭기조내 용존산소농도 제어)

  • Kim, Chang-Hyun;Hur, Dong-Ryol;Kim, Sang-Hyo;Chung, Hyeng-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2000.07d
    • /
    • pp.2479-2481
    • /
    • 2000
  • It is the time-varying dissolved oxygen(DO) dynamics that requires controlling for maintaining the DO concentration in the aeration tank. Many linear controllers have thus been applied. Because of the nonlinearity of the oxygen transfer function together with the time-varying respiration rate, however, the linear controllers are found to poorly perform in many cases. To overcome this limitation, a number of advanced controlling techniques have been developed and applied. In this study, designed GA-PI Controller using genetic algorithm(GA). Genetic algorithms(GAs) are search algorithms based on the mechanics of natural selection and natural genetics. As result of computer simulation, GA-PI controller shows the better control performance especially under the condition of the continuously changing DO set-point. This result represents that GA-PI controller can be a good measure to control the DO concentration in the SBR process which requires the sequential DO set-point change to accomplish the nitrification and denitrification in a single reactor.

  • PDF