• Title/Summary/Keyword: Dissipation test

Search Result 750, Processing Time 0.029 seconds

Cyclic tests and numerical study of composite steel plate deep beam

  • Hu, Yi;Jiang, Liqiang;Zheng, Hong
    • Earthquakes and Structures
    • /
    • 제12권1호
    • /
    • pp.23-34
    • /
    • 2017
  • Composite steel plate deep beam (CDB) is proposed as a lateral resisting member, which is constructed by steel plate and reinforced concrete (RC) panel, and it is connected with building frame through high-strength bolts. To investigate the seismic performance of the CDB, tests of two 1/3 scaled specimens with different length-to-height ratio were carried out under cyclic loads. The failure modes, load-carrying capacity, hysteretic behavior, ductility and energy dissipation were obtained and analyzed. In addition, the nonlinear finite element (FE) models of the specimens were established and verified by the test results. Besides, parametric analyses were performed to study the effect of length-to-height ratio, height-to-thickness ratio, material type and arrangement of RC panel. The experimental and numerical results showed that: the CDBs lost their load-carrying capacity because of the large out-of plane deformation and yield of the tension field formed on the steel plate. By increasing the length-to-height ratio of steel plate, the load-carrying capacity, elastic stiffness, ductility and energy dissipation capacity of the specimens were significantly enhanced. The ultimate loading capacity increased with increasing the length-to-height ratio of steel plate and yield strength of steel plate; and such capacity increased with decreasing of height-to-thickness ratio of steel plate and gap. Finally, a unified formula is proposed to calculate their ultimate loading capacity, and fitting formula on such indexes are provided for designation of the CDB.

Steel-Plate 매입형 합성 연결보의 접합부 상세에 따른 내진거동 (Seismic Behavior by Beams-Wall Connections depending upon Joint Details of Embedded Steel-Plate Composite Coupling Beams)

  • 주재형;채승윤;김선규;김우재;전호민;박효선
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.130-133
    • /
    • 2006
  • Owing to Higher story tendency and ceiling hight restriction of recent times, even though the depth of Coupling Beam decreases the demand efficiency is coming to be high rather so it is the difficult to satisfy a demand efficiency with the actual existing RC/Steel condition. It has been researched a lot of methods as an alternative plan about these but designer cannot apply them for the reason ; the structure standard and theory background are not taking a triangular position. As accomplishing the test research about the beams-wall connections department of steel-plate composite coupling beams from the research in the study it examines closely the beams-wall connections conduct quality and tries to provide the fundamental data for reasonable and optimum connection department designs. It knows that connection fixation degree and composite conduct degree of member part together become the important variable showing an energy dissipation ability in Test result.

  • PDF

6.6 kV 전동기 고정자 권선의 절연진단과 절연파괴 특성 (Characteristics of Insulation Diagnosis and Failure in 6.6 kV Motor Stator Windings)

  • 김희동;공태식
    • 한국전기전자재료학회논문지
    • /
    • 제25권4호
    • /
    • pp.309-314
    • /
    • 2012
  • To assess the condition of stator insulation, nondestructive and overpotential tests were performed on four high voltage motors. The stator windings under these tests have nominal ratings of 6.6 kV. After completing nondestructive tests, the AC overvoltage applied to the stator windings was gradually increasing until insulation failure in order to obtain the breakdown voltage. No. 1, No. 2, No. 3 and No. 4 of 6.6 kV motors failed near rated voltage of 18.4 kV, 19.8 kV, 19.7 kV and 21.7 kV, respectively. The breakdown voltage of four motors was higher that expected for good quality coils(14.2 kV) in 6.6 kV motors. Almost all of failures were located in a line-end coil at the exit from the core slot. The breakdown voltages and the types of defects showed strong relation to the stator insulation tests such as in the case of AC current, dissipation factor($tan{\delta}$) and partial discharge magnitude.

Experimental study on mechanical performances of lattice steel reinforced concrete inner frame with irregular section columns

  • Xue, Jianyang;Gao, Liang;Liu, Zuqiang;Zhao, Hongtie;Chen, Zongping
    • Steel and Composite Structures
    • /
    • 제16권3호
    • /
    • pp.253-267
    • /
    • 2014
  • Based on the test on a 1/2.5-scaled model of a two-bay and three-story inner frame composed of reinforced concrete beams and lattice steel reinforced concrete (SRC) irregular section columns under low cyclic reversed loading, the failure process and the features of the frame were observed. The subsequence of plastic hinges of the structure, the load-displacement hysteresis loops and the skeleton curve, load bearing capacity, inter-story drift ratio, ductility, energy dissipation and stiffness degradation were analyzed. The results show that the lattice SRC inner frame is a typical strong column-weak beam structure. The hysteresis loops are spindle-shaped, and the stiffness degradation is insignificant. The elastic-plastic inter-story deformation capacity is high. Compared with the reinforced concrete frame with irregular section columns, the ductility and energy dissipation of the structure are better. The conclusions can be referred to for seismic design of this new kind of structure.

강섬유 보강 기둥의 강도 및 변형 특성 (Strength and Deformation Characteristics of Steel Fiber Reinforced Columns)

  • 장극관;이현호;양승호
    • 콘크리트학회논문집
    • /
    • 제14권1호
    • /
    • pp.49-57
    • /
    • 2002
  • 합성재료중 강섬유(Steel fiber)로 보강된 콘크리트는 보강되지 않은 콘크리트에 비하여 전단, 휨, 피로강도 증진 및 균열제어 효과가 우수한 것으로 평가되고 있다. 특히 전단에 대한 강섬유 보강효과는 취성적인 전단파괴에서의 안정적인 휨 파괴로의 파괴 양상 변화를 보이는 것으로 보고되고 있다. 따라서, 본 연구에서는 기존연구결과 및 총 10개의 실험체를 대상으로 철근콘크리트 기둥에 대한 강섬유의 전단보강 효과를 평가하였다. 실험결과, 강섬유 혼입율 1.5 %에서 전단강도 증진효과가 가장 우수한 것으로 평가되었으며, 연성능력의 증진도 우수한 것으로 평가되었다. 그러나, 강도 및 연성능력 증진에 비하여 강성 및 에너지 소산 능력에 대한 강섬유 보강효과는 다소 미흡한 것으로 평가되었다.

철근콘크리트 프레임면내 조적벽체의 골조 구속에 따른 내진성능 평가 및 개선 (Improvement and Evaluation of Seismic Resistant Performance of Reinforced Concrete Infilled Masonry Frame with Restraining Factor of Frame)

  • 신종학;하기주;이희종
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제5권3호
    • /
    • pp.131-139
    • /
    • 2001
  • Experimental programs were accomplished to improve and evaluate the structural performance of RC frame structures with masonry infilled wall, such as the hysteretic behavior, the maximum horizontal strength, crack propagation, and ductility etc. Test variables are restraining factors of frame, with or without masonry infilled wall, and masonry method. Six reinforced concrete rigid frame and masonry infilled wall were tested and constructed in one-third scale size under vertical and cyclic loads simultaneously. Based on the test results, the following conclusions can be made. For masonry infilled wall with restraining factors of frame(IFWB-1~3), cumulated energy dissipation capacities were increased by 1.35~1.60 times in comparision with that of masonry infilled wall(IFB-1) at final stage of testing. For masonry infilled wall with restraining factors of frame, maximum horizontal capacities were increased by 1.91~2.24 times in comparision with that of rigid frame.

  • PDF

Dynamic behaviors of viscous damper on concrete archaized building with lintel-column joint

  • Xue, Jianyang;Dong, Jinshuang;Sui, Yan
    • Earthquakes and Structures
    • /
    • 제13권4호
    • /
    • pp.409-419
    • /
    • 2017
  • In order to analyze the vibration control effect of viscous damper in the concrete archaized buildings with lintel-column joints under seismic action, 3 specimens were tested under dynamic excitation. Two specimens with viscous damper were defined as the controlled component and one specimen without viscous damper was specified as the non-controlled component. The loading process and failure patterns were obtained from the test results. The failure characteristics, skeleton curves and mechanical behavior such as the load-displacement hysteretic loops, load carrying capacity, degradation of strength and rigidity, ductility and energy dissipation of the joints were analyzed. The results indicate that the load-bearing capacity of the controlled component is significantly higher than that of the non-controlled component. The former component has an average increase of 27.4% in yield load and 22.4% in ultimate load, respectively. Meanwhile, the performance of displacement ductility and the ability of energy dissipation for the controlled component are superior to those of the non-controlled component as well. Compared with non-controlled component, equivalent viscous damping coefficients are improved by 27.3%-30.8%, the average increase is 29.0% at ultimate load for controlled component. All these results reflect that the seismic performance of the controlled component is significantly better than that of the non-controlled component. These researches are helpful for practical application of viscous damper in the concrete archaizing buildings with lintel-column joints.

Experimental study on seismic behavior of frame structures composed of concrete encased columns with L-shaped steel section and steel beams

  • Zeng, Lei;Ren, Wenting;Zou, Zhengtao;Chen, Yiguang;Xie, Wei;Li, Xianjie
    • Earthquakes and Structures
    • /
    • 제16권1호
    • /
    • pp.97-107
    • /
    • 2019
  • The frame structures investigated in this paper is composed of Concrete encased columns with L-shaped steel section and steel beams. The seismic behavior of this structural system is studied through experimental and numerical studies. A 2-bay, 3-story and 1/3 scaled frame specimen is tested under constant axial loading and cyclic lateral loading applied on the column top. The load-displacement hysteretic loops, ductility, energy dissipation, stiffness and strength degradation are investigated. A typical failure mode is observed in the test, and the experimental results show that this type of framed structure exhibit a high strength with good ductility and energy dissipation capacity. Furthermore, finite element analysis software Perform-3D was conducted to simulate the behavior of the frame. The calculating results agreed with the test ones well. Further analysis is conducted to investigate the effects of parameters including concrete strength, column axial compressive force and steel ratio on the seismic performance indexes, such as the elastic stiffness, the maximum strength, the ductility coefficient, the strength and stiffness degradation, and the equivalent viscous damping ratio. It can be concluded that with the axial compression ratio increasing, the load carrying capacity and ductility decreased. The load carrying capacity and ductility increased when increasing the steel ratio. Increasing the concrete grade can improve the ultimate bearing capacity of the structure, but the ductility of structure decreases slightly.

An experimental study on a steel multi-slit damper for seismic retrofit of soft-first story structures

  • Mohammad Mahdi Javidan;Jinkoo Kim
    • Steel and Composite Structures
    • /
    • 제50권6호
    • /
    • pp.721-734
    • /
    • 2024
  • In this research, the efficiency of a metallic energy dissipation device for seismic retrofit of an existing structure is evaluated by cyclic loading test. The proposed device, which is called multi-slit damper, is made of weak and strong slit dampers connected in series. Its energy dissipation mechanism consists of two stages: (i) yielding of the weak-slit damper under minor earthquakes; (ii) restraint of further deformations of the weak slit damper and activation of the strong slit damper under major earthquakes using a gap mechanism. A reinforced concrete (RC) frame with characteristics similar to soft-first-story structures is tested under cyclic loading before and after retrofit using the proposed device. The details of the experimental study are described and the test is simulated in an available commercial software to validate the analytical model of the damper. To further verify the applicability of the damper, it is applied to an analysis model of a 4-story structure with soft first story and its seismic performance is evaluated before and after retrofit. The experimental and analysis results show that the multi-slit damper is effective in controlling seismic response of structures.

A Low Distortion and Low Dissipation Power Amplifier with Gate Bias Control Circuit for Digital/Analog Dual-Mode Cellular Phones

  • Maeng, Sung-Jae;Lee, Chang-Seok;Youn, Kwang-Jun;Kim, Hae-Cheon;Mun, Jae-Kyung;Lee, Jae-Jin;Pyun, Kwang-Eui
    • ETRI Journal
    • /
    • 제19권2호
    • /
    • pp.35-47
    • /
    • 1997
  • A power amplifier operating at 3.3 V has been developed for CDMA/AMPS dual-mode cellular phones. It consists of linear GaAs power MESFET's, a new gate bias control circuit, and an output matching circuit which prevents the drain terminal of the second MESF from generating the harmonics. The relationship between the intermodulation distortion and the spectral regrowth of the power amplifier has been investigated with gate bias by using the two-tone test method and the adjacent channel leakage power ratio (ACPR) method of CDMA signals. The dissipation power of the power amplifier with a gate bias control circuit is minimized to below 1000 mW in the range of the low power levels while satisfying the ACPR of less than -26 dBc for CDMA mode. The ACPR of the power amplifier is measured to be -33 dBc at a high output power of 26 dBm.

  • PDF