• Title/Summary/Keyword: Displacement analysis

Search Result 5,905, Processing Time 0.031 seconds

Coupled Thermal-Hydrological-Mechanical Behavior of Rock Mass Surrounding Cavern Thermal Energy Storage (암반공동 열에너지저장소 주변 암반의 열-수리-역학적 연계거동 분석)

  • Park, Jung-Wook;Rutqvist, Jonny;Ryu, Dongwoo;Synn, Joong-Ho;Park, Eui-Seob
    • Tunnel and Underground Space
    • /
    • v.25 no.2
    • /
    • pp.155-167
    • /
    • 2015
  • The thermal-hydrological-mechanical (T-H-M) behavior of rock mass surrounding a high-temperature cavern thermal energy storage (CTES) operated for a period of 30 years has been investigated by TOUGH2-FLAC3D simulator. As a fundamental study for the development of prediction and control technologies for the environmental change and rock mass behavior associated with CTES, the key concerns were focused on the hydrological-thermal multiphase flow and the consequential mechanical behavior of the surrounding rock mass, where the insulator performance was not taken into account. In the present study, we considered a large-scale cylindrical cavern at shallow depth storing thermal energy of $350^{\circ}C$. The numerical results showed that the dominant heat transfer mechanism was the conduction in rock mass, and the mechanical behavior of rock mass was influenced by thermal factor (heat) more than hydrological factor (pressure). The effective stress redistribution, displacement and surface uplift caused by heating of rock and boiling of ground-water were discussed, and the potential of shear failure was quantitatively examined. Thermal expansion of rock mass led to the ground-surface uplift on the order of a few centimeters and the development of tensile stress above the storage cavern, increasing the potential of shear failure.

A Biomechanical Analysis of Four Different Taekwondo Body Punch Types in Horseback-Riding Stance (태권도 주춤 서 몸통지르기 유형별 생체역학적 변인 비교 분석)

  • Kang, Sung-Chul;Kim, Eui-Hwan;Shin, Hyun-Moo;Kim, Sung-Sup;Kim, Tae-Whan
    • Korean Journal of Applied Biomechanics
    • /
    • v.17 no.4
    • /
    • pp.201-208
    • /
    • 2007
  • The purpose of this study is to compare 4 different body punch types(type 1: a punch using a shoulder, type 2: a punch using a waist, type 3: a punch using lower extremities, and type 4: a punch with elbows by your side at chest level) in horseback-riding stance and establish suitable teaching theory and method, which would be a useful reference to Taekwondo instructors on the spot(in Taekwondo dojangs all around Korea). Five exhibition players from Korean national Taekwondo exhibition team participated in this study. Each participant was asked to perform the four different types of punches and their kinematic and kinetic data were recorded with 7 vicon cameras(125Hz) and two force plates(AMTI, 1200Hz). We analyzed displacement, time, resultant center of body mass trajectory, velocity, trunk angular velocity, and ground reaction force(GRF) from each body segment in body punch and the result. I performed 1-way ANOVA(RM) for average values of each player after standardization and statistical significance was set as p<.05. was as the following ; First, they showed a tendency to take the body punch posture with the biggest motion at a shoulder and on descending order a waist and a knee. Second, a mean time for each body punch on ascending order 0.46sec. for type 2, 0.49sec for type 3, 0.50sec. for type 4, and 0.56sec. for type 1. Third, a mean resultant center of body mass trajectory for each body punch the longest 4.07cm for type 3 and the shortest 2.458cm for type 1. Fourth, a mean of maximal velocity of a fist strike was the fastest 5.99m/s for type 3, 5.93m/s for type 4, 5.67m/s for type 2, and 5.01m/s for type 1 on the descending order. Fifth, a mean of maximal trunk angular velocity of the fastest 495.6deg./sec. for type 4 and 337.7deg./sec. for type 1 on the descending order. Sixth, strongest value was type 3, 2 for anterior-posterior ground reaction force(left -54.89N, right 60.58N), type 4 for medial-lateral GRF(left 83.59N, right -80.12N), and type 3 for vertical GRF(left 341.79N, right 426.11N).

A Biomechanical Comparative Analysis between Single-Radius and Multi-Radius Total Knee Arthroplasty for Sit-to-Stand Movement (앉았다 일어나는 동작동안 단축회전반경 무릎인공관절 수술자와 다축회전반경 무릎인공관절 수술자의 운동역학적 비교분석)

  • Jin, Young-Wan
    • Journal of Life Science
    • /
    • v.16 no.5
    • /
    • pp.773-779
    • /
    • 2006
  • Eight of the individuals had a unilateral S-RAD TKA and Multi-Radius TKA ($Scorpio^{TM}$ PS, Howmedica-Osteonics, Inc.). The instrument were used Peak Motion Measurement $System^{TM}$, $MYOPAC^{TM}$EMG System, KIN-COM $III^{TM}$ System. The Figure 3 shows that the average time for the S-RAD group to accomplish the sit-to-stand movement was 1.59 s, which was 0.19 s less than the M-RAD group (p= 0.033). In Figure 5, the S-RAD TKA group tended to have $7^{\Omega}{\cdot}S^{-1}$ less trunk flexion velocity than that of the M-RAD group (p= 0.058). The Figure 6 shows that the S-RAD TKA limb tended to have less ADD displacement (p = 0.071) than that of the M-RAD TKA limb. We failed to find significant differences for ABD and ADD displacements between the S-RAD and M-RAD N-TKA limbs (p= 0.128 and 0.457, respectively). The VM of the S-RAD TKA limb demonstrated significant less RMS EMG than that of the M-RAD TKA limb from $60^{\Omega}$ to $15^{\Omega}$ of knee flexion (p 0.05). The VL of the S-RAD TKA limb also demonstrated significant less RMS EMG than that of the M-RAD TKA limb from $60^{\Omega}$ to $45^{\Omega}$ of knee flexion (p 0.05). Similar to the VM and VL, the RF of the S-RAD TKA limb showed less RMS EMG than that of the M-RAD TKA limb from $60^{\Omega}$ to $30^{\Omega}$ of knee flexion (p 0.05).

Clinical Experiences of Facial Asymmetries in Zygomaticomaxillary Complex Bone Fracture Patients (관골상악골 복합체 골절 환자에서의 안면 비대칭에 대한 임상경험)

  • Kang, Nak-Heon;Choi, Sang-Mun;Kim, Joo-Hak;Song, Seung-Han;Oh, Sang-Ha
    • Archives of Plastic Surgery
    • /
    • v.38 no.2
    • /
    • pp.161-165
    • /
    • 2011
  • Purpose: Zygomaticomaxillary complex (ZMC) fracture is one of the most common facial injuries after facial trauma. As ZMC composes major facial buttress, it is a key element of the facial contour. So, when we treat these fractures, the operator should have a concern with the symmetry to restore normal appearance and function. But sometimes, unfavorable results may occur. The aim of this study is to analyze the unsatisfied midfacial contour after ZMC fractures reduction retrospectively and to point out the notandum. Methods: 369 patients, treated for fractures of the ZMC were included in the study. After the operation, such as open reduction and internal fixation (ORIF with titanium or absorbable materials), open reduction, and closed reduction, midfacial contour was evaluated with plain films and 3-dimensional computed tomography. And unfavorable asymmetric midfacial contours were correcterd by secondary correction and re-evaluated. Gross photographs were obtained at outpatient clinic. Results: Total of 38 patients had got a facial asymmetry and among of them 24 patients were treated secondary revisional ORIF operations for correction of unfavorable result of after primary reduction. Two of them had received tertiary operations, three patients had got osteotomy more than after one year and six patients had got minor procedures. The etiology of asymmetry were lateral displaced simple fracture of arch (n=2), lateral displaced comminuted fracture of arch (n=6), comminuted arch fracture combined posterior root fracture (n=9), and communited arch and body fracture (n=12), severely contused soft tissue (n=9). After the manipulations outcomes were acceptable. Conclusion: To prevent the asymmetry in ZMC fracture reduction, complete analysis of fracture, choice of appropriate operation technique, consider soft tissue, and secure of zygoma position are important. Especially, we should be more careful about communited fracture of zygomatic body and lateral displacement, root fracture of zygomatic arch. Because they are commom causes that make facial asymmetry. To get optimal result, ensure the definite bony reduction.

Kinematic Analysis of the Badminton Drive Motion (배드민턴 드라이브 동작의 운동학적 분석)

  • Wei, Lin-Lin;Oh, Cheong-Hwan;Jeong, Ik-Su;Park, Chan-Ho;Lee, Jeong-Tae
    • Korean Journal of Applied Biomechanics
    • /
    • v.19 no.1
    • /
    • pp.77-85
    • /
    • 2009
  • This study is aimed at providing information on injury prevention and skill improvement by inducing the accurate movements in exercise as well as understanding the principles of badminton drive movements. Movement displacement of racket head showed the similar patterns among those surveyed but, it seemed that slight differences resulted from external factors such as height, length of brachial and forearm and individual trend of swing locus. Regarding upper joint angle per phase, the angles of shoulder joint, elbow joint and wrist joint were closely associated in taking drive movements and they supported the segment order theory that power was conveyed from proximal into distal. It was shown that angular velocity of upper joint became larger in follow through movement after impact among all those surveyed, which meant the importance of follow through in racket sports such as badminton. In conclusion, this follow through movement acts as an important factor in racket sports in terms of pose stability maintenance, pose correction of movements and injury prevention of joints. In summary, when swings are made according to segment order theory, efficient movements can be taken.

The Comparative Kinematic Analysis of a Volleyball Spike Serve (배구 스파이크 서브 동작의 운동학적 비교 분석)

  • Park, Jong-Chul;Back, Jin-Ho;Lee, Jin-Taek
    • Korean Journal of Applied Biomechanics
    • /
    • v.19 no.4
    • /
    • pp.671-680
    • /
    • 2009
  • We performed a study to obtain kinematic data on the characteristics of spike serving techniques used by volleyball players, including other basic data that will be useful for in-field applications. We used three-dimensional videography to compare good tough serves and serve errors. The subjects were 3 left attackers whose spike serves were videographed (60 fileds/s). The three-dimensional coordinates were calculated using the direct linear transformation method and then analyzed using the Kwon 3D software program version 3.1. There was no difference in time elapsed. However, the vertical displacement of the center of body mass(CM) differed between the 2 types of serves: in successful serves, the CM tended to be lower, as did the maximum ball height at the time of hitting. Further, the higher the level of the hitting hand was at the moment of impact, the higher was the likelihood of scoring points. In good serves, the players tended to accelerate their CM movement just before jumping to hit the ball and descend rapidly at the moment of hitting. The hand speed along with ball velocity during the impact was proven to be higher in successful serves. Moreover, in successful serves, the shoulder angles increased to a greater extent while the elbow angles were maintained constant. This possibly resulted in faster and more precise serves. An important observation was that the angle of trunk inclination during the jump did not increase with the swing of the shoulders, muscle tendon complex.

The Objective Measurement of the Lung Parenchyma Motion for Planning Target Volume Delineation (폐 부위 Planning Target Volume(PTV)설정시 폐 움직임의 객관적 측정)

  • Chung, Weon-Kyu;Cho, Jeong-Gill
    • Radiation Oncology Journal
    • /
    • v.15 no.4
    • /
    • pp.387-392
    • /
    • 1997
  • Purpose : To quantify the movement of lung Parenchyma for ICRU 50 Planning Target Volume (PTV) delineation of the lung region. Materials and Method : Fluoroscopic observations and measurements are Performed on 10 patients with chest region cancer who have normal putmonary functions We have divided the lung region into 12 parts for the right lung, 10 parts for the left lung and four to five Points of lung parenchyma were selected for anatomical analysis Points, Fluoroscopic images are sent to a computer and then movements are measured. Results : Both lowe lobes showed the longest longitudinal movements because of breathing (average 14.1mm, maximum 22.1mm), while anteroposterior displacement showed the smallest value. Lateral movements of the lung parenchyma averaged 6.6mm, and the maximum value was 9.1mm, (both hilar regions showed maximum values because of cardiac motion) Conclusion : We could quantify the lung movements by measuring parenchyma displacements. The movements of both upper lobes were less than those of the middle and upper lobes in longitudinal and transverse movements. Optimal margins can be selected for PTV delineation using these results.

  • PDF

Behavior of Wide Beam-Column Interior Joint with Slab (횡력을 받는 넓은 보-기둥 내부 접합부의 거동 평가)

  • Lee, Bum-Sik;Park, Seong-Sik;Park, Ji-Young
    • Land and Housing Review
    • /
    • v.3 no.4
    • /
    • pp.433-449
    • /
    • 2012
  • An experimental investigation was conducted to study the behavior of RC wide beam-column joints with slab subjected to reversed cyclic loads under constant axial load. Six half scale interior wide beam-column assemblies representing a portion of a frame subjected to simulated seismic loading were tested, including three specimens without slab and three specimens with slab. The primary variables were the ratio of column-to-beam flexural capacity ($M_r={\Sigma}M_c/{\Sigma}M_b$ ; 0.77~2.26), ratio of the column-to-beam width (b/H ; 1.54, 1.67). Test results are shown that (1) the current design code and practice for interior joints(type 2) are apply to the wide beam-high strength concrete column. (2) the presence of a slab have an effect on the performance of the wide beam-high strength concrete column interior joints(type 2). therefore in the design of the wide beam-high strength concrete column interior joints(type 2), the width of slab effective as a T beam flange should be considered. It was show that the case of the ratio of column-to-beam flexural capacity is more than 2.0, the effective width of slab are 2 times of an effective depth of wide beam, however if the ratio of column-to-beam flexural capacity is 1.4~2.0, the effective width of slab are not able to be considered.

Flexural Behavior of Large-Diameter Composite PHC pile Using In-Filled Concrete and Reinforcement (속채움 콘크리트와 철근으로 보강된 대구경 합성 PHC말뚝의 휨성능 평가)

  • Bang, Jin-Wook;Park, Chan-Kyu;Yang, Seong-Yeong;Kim, Yun-Yong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.5
    • /
    • pp.109-115
    • /
    • 2016
  • A demand of high bearing capacity of piles to resist heavy static loads has been increased. For this reason, the utilization of large diameter PHC piles including a range from 700 mm to 1,200 mm have been increased and applied to the construction sites in Korea recently. In this study, in order to increase the flexural strength capacity of the PHC pile, the large diameter composite PHC pile reinforced by in-filled concrete and reinforcement was developed and manufactured. All the specimens were tested under four-point bending setup and displacement control. From the strain behavior of transverse bar, it was found that the presence of transverse bar was effective against crack propagation and controlling crack width as well as prevented the web shear cracks. The flexural strength and mid-span deflection of LICPT specimens were increased by a maximum of 1.08 times and 1.19 times compared to the LICP specimens. This results indicated that the installed transverse bar is in an advantageous ductility performance of the PHC piles. A conventional layered sectional analysis for the pile specimens was performed to investigate the flexural strength according to the each used material. The calculated bending moment of conventional PHC pile and composite PHC pile, which was determined by P-M interaction curve, showed a safety factor 1.13 and 1.16 compared to the test results.

A STUDY ON TOOTH FRACTURE WITH THREE DIMENSIONAL FINITE ELEMENT METHOD (치아파절에 관한 3차원유한요소법적 연구)

  • Cho, Byeong-Hoon;Um, Chung-Moon
    • Restorative Dentistry and Endodontics
    • /
    • v.18 no.2
    • /
    • pp.291-316
    • /
    • 1993
  • Restorative procedures can lead to tooth fracture due to the relatively small amount of the remaining tooth structure. It is essential to prevent fractures by having a clear concept of the designs for cavity preparations. Among the several parameters in cavity designs, profound understanding of isthmus width factor would facilitate selection of the appropriate cavity preparation for a specific clinical situation. In this study, MO amalgam cavity were prepared on maxillary first premolar and filled with amalgam. Three dimensional, model with 1365 8-node brick elements was made by serial photographic method. In this model, isthmus was varied in width at 1/4, 1/3, 1/2 and 2/3 of intercuspal width and material properties were given for three element groups, i.e., enamel, dentin and amalgam. A load of 500 N was applied vertically on amalgam and enamel. In case of enamel loading, 2 model (with and without amalgam) was compared to consider the possibility of play at the interface between tooth material and amalgam. These models were analyzed with three dimensional finite element method. The results were as follows: 1. The stress was concentrated on the facio-pulpal line angle and distal marginal ridge of the cavity. 2. With the increase of the isthmus width, the stress spread around the facio-pulpal line angle and the area of stress concentration moved toward the proximal box. 3. In case of narrow isthmus width, the initiation point of crack would be in the area of isthmus corner of the cavity, and with the increase of the isthmus width, it would move toward the proximal box and at the same time the possibility of crack increase at the distal marginal ridge. 4. The direction of crack progressed outward and downward from the facio-pulpal line angle, and with the increase of the isthmus width, it approximated vertical direction. At the marginal ridge, it occurred in vertical direction. 5. It would be favorable to make the isthmus width narrower than a third of the intercuspal width, and to cover the cusp if isthmus width were wider than half of the intercuspal width. 6. It is necessary to apply the possibility of play to the finite element analysis.

  • PDF