• Title/Summary/Keyword: Dispersion variation

Search Result 275, Processing Time 0.027 seconds

ULTRAVIOLET FLUX VARIATION OF EPSILON AURIGAE

  • Kang, Young-Woon
    • Journal of Astronomy and Space Sciences
    • /
    • v.7 no.1
    • /
    • pp.57-69
    • /
    • 1990
  • The eighteen ultraviolet light curves of Epsilon Aurigae have been plotted using the integrated fluxes reduced from the 233 IUE low dispersion spectra taken between 1978 and 1986. The times of contacts and depth of eclipse have been determined from the light curves at the wavelength from 2550 $AA$ to 3050 $AA$. The UV light curves show two brightenings during the totality, the downward slope of the variation from the second to the third contacts, and asymmetry of the eclipse light curve. The two selected spectra note that the energy density distribution is not changed between the totality of the eclipse and out-of-eclipse.

  • PDF

Fabrication of Oxygen Sensitive Particles and Characteristic Analysis (산소감응성 입자 제조 및 특성 분석 연구)

  • Jeong, Won-Taek;Yi, Seung-Jae;Kim, Hyun-Dong;Kim, Kyung-Chun
    • Journal of the Korean Society of Visualization
    • /
    • v.9 no.4
    • /
    • pp.41-46
    • /
    • 2011
  • Oxygen sensitive functional particles(OSParticle) were fabricated by three different methods for using the particles as oxygen sensors and PIV tracers. The used methods were a physical coating method, an ion-exchange method and a dispersion polymerization method. The physical coating method is dipping $SiO_2$ hollow particles into dye solution then drying. This method is very simple, but particles are not uniform in diameter and luminescence. The particles fabricated by the ion-exchange method have very uniform diameter and well doped. However, it can not be used in water since the particles are hydrophobic. In case of the dispersion polymerization method, the diameter of OSParticles is quite uniform. The diameter of OSParticles can be changed by controlling the quantity of AIBN (2,2'-azobis isobutyronitrile). For the purpose of dissolved oxygen concentration measurement in micro scale water flows, the dispersion polymerized OSParticles turn out to be the most superior functional particles. The luminescent intensity of OSParticles was tested with the variation of dissolved oxygen concentration in water samples. As a result, the luminescent intensity of OSParticles is monotonically decreased with increasing DO (Dissolved oxygen) concentration of water.

Heat Energy Diffusion Analysis in the Gas Sensor Body with the Variation of Drain-Source Electrode Distance (드레인-소스 전극 간극의 변화에 따른 Gas Sensor의 열에너지 확산 해석)

  • Jang, Kyung-Uk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.30 no.9
    • /
    • pp.589-595
    • /
    • 2017
  • MOS-FET structured gas sensors were manufactured using MWCNTs for application as NOx gas sensors. As the gas sensors need to be heated to facilitate desorption of the gas molecules, heat dispersion plays a key role in boosting the degree of uniformity of molecular desorption. We report the desorption of gas molecules from the sensor at $150^{\circ}C$ for different sensor electrode gaps (30, 60, and $90{\mu}m$). The COMSOL analysis program was used to verify the process of heat dispersion. For heat analysis, structure of FET gas sensor modeling was proceeded. In addition, a property value of the material was used for two-dimensional modeling. To ascertain the degree of heat dispersion by FEM, the governing equations were presented as partial differential equations. The heat analysis revealed that although a large electrode gap is advantageous for effective gas adsorption, consideration of the heat dispersion gradient indicated that the optimal electrode gap for the sensor is $60{\mu}m$.

Comparison of Model Results for Variation and Resolution of Meteorological Field Using HY-SPLIT (기상장의 종류와 해상도에 따른 HY-SPLIT 모델의 결과 비교)

  • Lee, Chong-Bum;Park, Sang-Jin;Kim, Jea-Chul;Jang, Yun-Jung
    • Journal of Environmental Impact Assessment
    • /
    • v.19 no.3
    • /
    • pp.223-230
    • /
    • 2010
  • Trajectory dispersion models are used for the dispersion calculations in air quality assessments, Yellow-sand modeling, environmental planning and the emergency response. Meso-scale forcing and coastal circulations are calculated by trajectory model in the East Asia region. In this study the meteorological fields (GDAS and MM5) coupled to the trajectory model (HY-SPLIT) are applied to simulate the transport and the dispersion. Seoul is selected as a starting point of the HY-SPLIT. The sensitivity studies are performed by conducting an ensemble of simulations using the GDAS and the MM5 model for the same dispersion cases. The results in this study show a significant difference depending on the resolution of meteorological models. Additionally, in most cases of the compared tionally,results from MM5 and GDAS, the absolute and relative distance, shows significant difference and the difference increased with the increasing distance of HY-SPLIT. Therefore, for the case of small domai for twi d field distefbution over complex terrai, should be used only high model temporal or spatial resolution to improve the HY-SPLIT model results.

The Characteristic of PU/MWNT Foaming Film (PU/MWNT 발포필름의 발포 특성연구)

  • Park, Jun-Hyeong;Park, Mi-Ra;Choi, La-Hee;Kim, Seung-Jin
    • Textile Coloration and Finishing
    • /
    • v.24 no.1
    • /
    • pp.79-90
    • /
    • 2012
  • This study surveys the characteristics of the PU/MWNT foaming film according to foaming conditions. For this purpose, firstly, 16 kinds of PU/MWNT forming films were prepared with 4 kinds of dispersion solutions (IPA/MWNT, DMF/MWNT, MEK/MWNT, and Toluene/MWNT) and 4 kinds of blowing agents (organic I, organic II, capsule, and inorganic). The electrical resistivity of these PU/MWNT foaming films according to the dispersion solutions and blowing agents were analysed and discussed with surface profile and cell morphology of measured by SEM. And secondly, 24 kinds of PU/MWNT foaming films were also prepared with 2 kinds of IPA dispersion solution contents and 3 kinds of blowing agents with variation of the blowing temperatures and film thickness. The physical properties of the PU/MWNT foaming films such as electrical resistivity (surface and volume) and triboelectricity with cell morphology were measured and discused through the quantities of IPA, blowing agent added and also physical conditions(temperature, thickness so on) for establishing optimum foaming conditions with good electrostatic dissipation.

Development of Empirical Formula for Transverse Dispersion Coefficient Based on Theoretical Equation in River Bends (만곡부에서 이론식에 기반한 횡분산계수 경험공식 개발)

  • Baek, Kyong Oh
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.6B
    • /
    • pp.373-378
    • /
    • 2012
  • In this study, a new empirical equation for the transverse dispersion coefficient has been developed based on the theoretical background in river bends. The nonlinear least-square method was applied to determine regression coefficients of the equation. The estimated dispersion coefficients derived by the new equation were compared with observed transverse dispersion coefficients acquired from natural rivers and coefficients calculated by the other existing empirical equations. From a comparison of the existing transverse dispersion equations and the new proposed equation, it appears that the behavior of the existing formula in a relative sense is very much dependent on the friction factor and the river geometry. However, the new proposed equation does not vary widely according to variation of friction factor. Also, it was revealed that the equation proposed in this study becomes an asymptotic curve as the curvature effect increases.

Large Eddy Simulation for the Prediction of Unsteady Dispersion Behavior of Hydrogen Fluoride (불산의 비정상 확산거동 예측을 위한 대와동모사)

  • Ko, M.W.;Oh, Chang Bo;Han, Y.S.;Choi, B.I.;Do, K.H.;Kim, M.B.;Kim, T.H.
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.1
    • /
    • pp.14-20
    • /
    • 2015
  • A Large Eddy Simulation(LES) was performed for the prediction of unsteady dispersion behavior of hydrogen fluoride (HF). The HF leakage accident occurred at the Gumi fourth industrial complex was numerically investigated using the Fire Dynamics Simulator (FDS) based on the LES. The accident area was modeled three-dimensionally and time-varying boundary conditions for wind were adopted in the simulation for considering the realistic accident conditions. The Message Passing Interface (MPI) parallel computation technique was used to reduce the computational time. As a result, it was found that the present LES simulation could predict the unsteady dispersion features of HF near the accident area effectively. The dispersion behaviors of the leaked HF was much affected by the unsteady wind direction. The LES could predict the time variation of the HF concentration reasonably and give an useful information for the risk analysis while the prediction with the time-averaging concept of HF concentration had a limitation for the amount of HF concentration at specific location point. It was identified that the LES is very useful to predict the dispersion characteristics of hazardous chemicals.

An Experimental Study on the Variation of Vertical Dispersion within Boundary Layer with Surface Roughness (대기 경계층 연직방향 확산의 지면 거칠기에 따른 변화에 관한 실험적 연구)

  • 박옥현;윤창옥
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.16 no.3
    • /
    • pp.237-246
    • /
    • 2000
  • An experimental study has been carried out using a rotating water channel in order to investigate the effect of surface roughness on the vertical dispersion of plume within boundary layer. Dispersion measurements of tracers released from two sources with different height at neutral conditions over various rough terrain ranging from rural to urban have been performed. Various values of roughness length were simulated by combining of 4 stream velocities and 3 roughness element conditions. Dispersion measurements have also been made for rough terrain where high buildings are locally concentrated. Values of $\sigma$z increase with roughness and this tendency appears to apply both cases of with and without locally concentrated high buildings. The comparisons of the Bowne's nomogram on $\sigma$2 vs x relationship and the measurements of $\sigma$2 with roughness show good accordance in $\sigma$2 distribution at stability D class over rural, suburban and urban terrain. For constant roughness length the $\sigma$2 values of plumes from lower source height are smaller than those of plumes from higher source at short downwind distance, but this relationship becomes reverse as distance increases. Crossing appears to be made before about 2km. The value of constant I in McMullen's equation $\sigma$2=exp [I+J(In x) + K(In x)2] appears to increase with roughness length, however, the relationships between other constants and roughness have been confirmed. The values of $\sigma$2 for various downwind distances, estimated by using an equation which is employed in ISC (Industrial Source Complex) dispersion model for areas where high buildings are locally assembled, are in accordance with measurements from water channel experiments.

  • PDF

A Study on the Diffusion of Atmospheric Pollutants over Taegu (대구상공에서의 대기 오염 물질 확산에 관한 연구)

  • Yun, Il-Hui;Min, Gyeong-Deok;Park, Dong-Jae
    • Journal of Environmental Science International
    • /
    • v.3 no.3
    • /
    • pp.241-252
    • /
    • 1994
  • Meteorological parameters In the atmospheric boundary layer and the vertical and horizontal dispersion parameters were determined by analyzing the data obtained by the special upper-air observations of one clear day for each season from October 1991 to August 1992. The concentration of the aklospheric pollutants over Taegu was analyzed by using the application of the Gaussian diffusion model. In the diurnal variation of diffusion of atmospheric pollutants, vertical diffusion due to turbulence is active in daytime while horizontal diffusion due to wind is active in nighttime. The mean concentration of pollutants in the side of downwind is higher during the daytime than the nighttime. Thus, the height of the mixed-layer at the nighttime considered as the most important parameter of the mean concentration of pollutants. In the seasonal variation of diffusion of atmospheric pollutants, vertical diffusion due to strong solar radiation is active in summer case day, and horizontal diffusion due to strong wind is active in winter case day. In winter case day, the mean concentration of pollutants in the side of downwind is maximum in the daytime. However, in summer case day, that is maximum in the nighttime.

  • PDF

Behavior of an Impinging Droplet on a Solid Surface with a Variation of Liquid Temperature (액체 온도 변화에 따른 평판 충돌 액적의 거동에 관한 연구)

  • Lee Dong Jo;Park Byung Sung;Chung Jin Taek;Kim Ho Young
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.3 s.234
    • /
    • pp.330-339
    • /
    • 2005
  • An experimental study on the behavior of droplets impinging on a solid flat surface was carried out in the present study. Breakup of a liquid droplet impinging on a solid surface has been investigated experimentally for various liquids with different properties. The liquid droplet temperature and incident angle were chosen as major parameters. Liquid droplet temperature and incident angle varied in the range from $-20{\circ}C\;to\;30{\circ}C\;and\;from\;30{\circ}\;to\;60{\circ},$ respectively. It was found that the variation of droplet temperature influences upon the mean diameter and uniformity of droplets which were bounced out from the solid surface. With increase of incident angle the dispersion mass fraction increases, causing the decrease of liquid film flow rate. As the liquid temperature increases, dispersion mass fraction increases since the surface tension decreases.