• Title/Summary/Keyword: Dispersion Error

Search Result 164, Processing Time 0.023 seconds

A Study on the Design of Dual­Band Equilateral­Triangular Microstrip Antennas (듀얼­밴드 정삼각형 마이크로스트립 안테나 설계에 관한 연구)

  • 문정군;이종철;황호순;이문수
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.7 no.8
    • /
    • pp.1604-1611
    • /
    • 2003
  • For dual­band operation, it can be done by loading two pair of slits in the equilateral­triangular patch, one embeded close to the side edges of the patch and the other inserted at the bottom edge of the patch. The frequency ratio of the two operating frequencies can be tuned by varing the positions and lengths of the inserted slots at the bottom edge of the patch. While the calculated frequency ratio of the antenna by Ensemble 5.0 is $1.66 ({f_10}=1.928GHz, {f_20}=3.2GHz)$, the measured one is 2.04 $({f_10}=1.6806 GHz, {f_20}=3.435 GHz)$. The error in the frequency ratio is due on the fabrication dimension and feeding position error as well as on the permittivity dispersion effect.

Analysis of Statistical Methods Currently used in Toxicology Journals

  • Na, Jihye;Yang, Hyeri;Bae, SeungJin;Lim, Kyung-Min
    • Toxicological Research
    • /
    • v.30 no.3
    • /
    • pp.185-191
    • /
    • 2014
  • Statistical methods are frequently used in toxicology, yet it is not clear whether the methods employed by the studies are used consistently and conducted based on sound statistical grounds. The purpose of this paper is to describe statistical methods used in top toxicology journals. More specifically, we sampled 30 papers published in 2014 from Toxicology and Applied Pharmacology, Archives of Toxicology, and Toxicological Science and described methodologies used to provide descriptive and inferential statistics. One hundred thirteen endpoints were observed in those 30 papers, and most studies had sample size less than 10, with the median and the mode being 6 and 3 & 6, respectively. Mean (105/113, 93%) was dominantly used to measure central tendency, and standard error of the mean (64/113, 57%) and standard deviation (39/113, 34%) were used to measure dispersion, while few studies provide justifications regarding why the methods being selected. Inferential statistics were frequently conducted (93/113, 82%), with one-way ANOVA being most popular (52/93, 56%), yet few studies conducted either normality or equal variance test. These results suggest that more consistent and appropriate use of statistical method is necessary which may enhance the role of toxicology in public health.

Estimation of Mass Error in the Simulation of Mixing of Instantaneously Released Pollutants (순간 유입된 오염물질의 혼합 모의 시 질량 오차 산정)

  • Lee, Myung Eun;Seo, Il Won
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.5B
    • /
    • pp.475-483
    • /
    • 2008
  • 2D finite element model for analysis of transport of accidentally released pollutants in the flow was developed by SUPG method, and the mass balance of this model was checked though two example problems: line source and point source problem in the straight channel and unidirectional 2D flow field, respectively. All the test cases were simulated with both SUPG and conventional Galerkin method to compare the accuraccy of the numerical mass balance. Test results show that the model with SUPG can adequately conserve the released mass though simulation than the model using Galerkin method, so the developed model verified to be appropriate to solve this accidental mass release problem.

Site Characterization using Shear-Wave Velocities Inverted from Rayleigh-Wave Dispersion in Wonju, Korea (레일리파 분산을 역산하여 구한 횡파속도를 이용한 원주시의 부지특성)

  • Kim, Chungho;Ali, Abid;Kim, Ki Young
    • Geophysics and Geophysical Exploration
    • /
    • v.17 no.1
    • /
    • pp.11-20
    • /
    • 2014
  • To reveal shear-wave velocities ($v_s$) and site characterization of Wonju, Korea, Rayleigh waves were recorded at 78 sites of lower altitude using 12 to 24 4.5-Hz vertical geophones for 20 days during the period of February to September 2013. Dispersion curves of the Rayleigh waves obtained by the extended spatial autocorrelation method were inverted using the damped least-squares method to derive $v_s$ models. From these 1-D models, the average $v_s$ to a depth of 30 m ($v_s30$), $v_s$ of weathered rocks, depths to these basement rocks, and average $v_s$ of the overburden layer were derived to be $16.3{\pm}0.7m$, $576{\pm}8m/s$, $290{\pm}7m/s$, and $418{\pm}13m/s$, respectively, in the 95% confidence range. To determine adequate proxies for $v_s30$, we computed correlation coefficients of $v_s30$ with topographic slope (r = 0.46) and elevation (r = 0.43). An empirical linear relationship is presented as a combination of individually estimated $v_s30$ with weighting factors of 0.45, 0.45, and 0.1 for topographic slope, elevation, and mapped lithology, respectively. Due to a weak correlation between $v_s30$ obtained from inversion of dispersion curves and the proxy-based estimation (r = 0.50), however, the relatively large error range should be considered for applications of this relationship.

A Study on the Flow and Dispersion in the Coastal Unconfined Aquifer (Development and Application of a Numerical Model) (해안지역 비피압 충적 대수층에서의 흐름 및 분산(수치모형의 개발 및 적용))

  • Kim, Sang Jun
    • Journal of Korea Water Resources Association
    • /
    • v.49 no.1
    • /
    • pp.61-72
    • /
    • 2016
  • In Korea, the aquifers at the coastal areas are mostly shallow alluvial unconfined aquifers. To simulate the flow and dispersion in unconfined aquifer, a FDM model has been developed to solve the nonlinear Boussinesq equation. Related analysis and verification have been executed. The iteration method is used to solve the nonlinearity, and the model shows 3-D shape because it is a 2-D y model that consider the undulation of water table and bottom. For the verification of the model, the output of flow module is compared to the 1-D analytic solution of Lee (1989) which have the drawdown or uplift boundary condition, and the two results show almost the same value. and the mass balance of dispersion module shows about 10% error. The developed model can be used for the analysis and design of the flow and dispersion in the unconfined aquifers. The model has been applied to the estuary area of Ssangcheon watershed, and the parameters have been deduced as a result : hydraulic conductivity is 90 m/day, and longitudinal dispersivity is 15 m. And the analysis with these parameters shows that the wells are situated in the influence circle of each others except for No. 7 well. Groundwater discharge to sea is $3700m^3/day$. And the chlorine ion ($cl^-$) concentration at the pumping wells increase at least 1000 mg/L if groundwater dam is not exist, so the groundwater dam plays an important role for the prevention of sea water intrusion.

Identification of Motor Parameters and Improvement of Voltage Error for Improvement of Back-emf Estimation in Sensorless Control of Low Speed Operation (저속 센서리스 제어의 역기전력 추정 성능 향상을 위한 모터 파라미터 추정과 전압 오차의 개선)

  • Kim, Kyung-Hoon;Yun, Chul;Cho, Nae-Soo;Jang, Min-Ho;Kwon, Woo-Hyen
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.5
    • /
    • pp.635-643
    • /
    • 2018
  • This paper propose a method to identify the motor parameters and improve input voltage error which affect the low speed position error of the back-emf(back electromotive force) based sensorless algorithm and to secure the operation reliability and stability even in the case where the load fluctuation is severe and the start and low speed operation frequently occurs. In the model-based observer used in this paper, stator resistance, inductance, and input voltage are particularly influential factors on low speed performance. Stator resistance can cause resistance value fluctuation which may occur in mass production process, and fluctuation of resistance value due to heat generated during operation. The inductance is influenced by the fluctuation due to the manufacturing dispersion and at a low speed where the change of the current is severe. In order to find stator resistance and inductance which have different initial values and fluctuate during operation and have a large influence on sensorless performance at low speed, they are commonly measured through 2-point calculation method by 2-step align current injection. The effect of voltage error is minimized by offsetting the voltage error. In addition, when the command voltage is used, it is difficult to estimate the back-emf due to the relatively large distortion voltage due to the dead time and the voltage drop of the power device. In this paper, we propose a simple circuit and method to detect the voltage by measuring the PWM(Pulse Width Modulation) pulse width and compensate the voltage drop of the power device with the table, thereby minimizing the position error due to the exact estimation of the back-emf at low speed. The suitability of the proposed algorithm is verified through experiment.

A Performance Evaluation of VSS-MMA Adaptive Equalization Algorithm using the Non-Linear Fuction of Error Signal for QAM System (QAM 시스템에서 오차 신호의 비선형 함수를 이용한 VSS-MMA 적응 등화 알고리즘의 성능 평가)

  • Lim, Seung-Gag
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.1
    • /
    • pp.131-137
    • /
    • 2015
  • This paper relates with the VSS-MMA (Variable Step Size-Multiple Modulus Algorithm) adaptive equalization algorithm which is possible to improving the equalization performance by use the nonlinear fuction of error signal in the MMA adaptive equalization algorithm that are used for the minimization of the intersymbol interference due to the distortion which occurs in the time dispersive channel for the transmission of QAM signal in the system.. In the conventional MMA, we obtains the tap coefficient of adaptive equalizer using the fixed step size, but in the VSS-MMA, we obtains the tap coefficient of adaptive equalizer using the variable step size based on a nonlinear function of error signal. By adapting the variable step size, it was confirmed that the improved equalization performance were obtained by computer simulation. For this, the equalizer output signal constellation, residual isi, maximum distortion, MSE and SER were used in the performace index.

Comparative analysis of methods for digital simulation (디지털 전산모사를 위한 방법론 비교분석)

  • Yi, Dokkyun;Park, Jieun
    • Journal of Digital Convergence
    • /
    • v.13 no.9
    • /
    • pp.209-218
    • /
    • 2015
  • Computer simulation plays an important role for a theoretical foundation in convergence technology and the interpolation is to know the unknown values from known values on grid points. Therefore it is an important problem to select an interpolation method for digital simulation. The aim of this paper is to compare analysis of interpolation methods for digital simulation. we test six different interpolation methods namely: Quartic-Lagrangian, Cubic Spline, Fourier, Hermit, PWENO and SL-WENO. Through digital simulation of a linear advection equation, we analyse pros and cons for each method. In order to compare performance, we introduce accuracy computing and Error functions. The accuracy computing is used well-known $L^1-norm$ and the Error functions are dispersion function, dissipation function and total error function. High-order methods well apply to computer simulation, unfortunately, side-effects (Oscillation) happen.

Study of Optical Transmission Performance in IP-over-WDM Networks Based on FSK/ASK Combined Modulation Format

  • Xiangjun, Xin;Andre, Paulo Sergio de Brito;Teixeira, Antonio Luis Jesus;Monteiro, Paulo P.;Rocha, Jose R. F. da
    • ETRI Journal
    • /
    • v.27 no.3
    • /
    • pp.267-272
    • /
    • 2005
  • The transmission performance of optical labeling based on a combined frequency shift keying/amplitude shift keying (FSK/ASK) format is studied by numerical simulation. The simulation demonstrates that the bit-error ratio (BER) characteristic of an ASK signal is limited by the extinction ratio, received optical power, and dispersion, simultaneously. However, an FSK signal is mainly limited by the extinction ratio (ER) and received optical power when the peak spectrum, which is used to detect the FSK signal, is relatively narrow.

  • PDF

An Improved Configuration for Radio over Fiber Transmission

  • Parvez, M.F.;Zhou, M.T.;Sharma, A.B.;Zhang, J.G.
    • Proceedings of the IEEK Conference
    • /
    • 2002.07a
    • /
    • pp.14-17
    • /
    • 2002
  • A configuration for radio-over-fiber transmission, with remote LO delivery from the central office, and a simple, cost-effective, base station solution is proposed. It is shown that using practically available components, and even with a fiber dispersion of 17 ㎰/nm/km, it is possible to transmit, without repeaters, bit rates of up to 622 Mbit/s for about 20 km at a bit-error rate of 10$\^$-9/, with 0㏈m laser power and a modest optical gain of 6㏈. By increasing the optical gain to 25 ㏈, the link length can be increased to ∼80 km.

  • PDF