• Title/Summary/Keyword: Dispenser

Search Result 133, Processing Time 0.025 seconds

A Temperature Compensating System for LPG Dispenser (LPG 충전기용 온도 보정 시스템 개발)

  • Lee, Sang-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 1999.07g
    • /
    • pp.3162-3164
    • /
    • 1999
  • In this paper, a temperature compensating system(TCS) for LPG dispenser has been developed. A TCS includes a processor(80C196) with an AID converter. I/O port(82C55) and 6-digit vacuum fluorescent display. Based on encoding signals from the gas flow meter, different calibration values from each apparatus and temperature compensating values from the temperature sensor, the TCS controls the LPG dispensing quantity with switching on or off the solenoid valves. The temperature compensation is performed with analog-to-digital conversion of the temperature sensor. The resolution of temperature compensation is nearly $0.5^{\circ}C$ using 10-bit ADC. The field test of the TCS shows the exact temperature compensation.

  • PDF

Stablilization of Field Emission Current (Field Emission 전류의 안정화)

  • Yamamoto, Shigehiko
    • Journal of the Korean Vacuum Society
    • /
    • v.2 no.3
    • /
    • pp.335-338
    • /
    • 1993
  • 텅스텐으로 만들어진 field emitter와 탄소로 만들어진 field emitter에서 생기는 step이나 spike 형태의 잡음에 대하여 비교 연구하였다. 그리고 dispenser 형태의 field emiter와 array 형태의 field emitter와 같은 새로운 형태의 field emitter를 설명하였다.

  • PDF

Advanced Password Input Method in Automated Teller Machines/Cash Dispenser (현금자동입출금기/현금지급기에서 개선된 비밀번호 입력 방법)

  • Kim, Tae-Hee;Park, Seung-Bae;Kang, Moon-Seol
    • The KIPS Transactions:PartC
    • /
    • v.18C no.2
    • /
    • pp.71-78
    • /
    • 2011
  • Financial accidents such as password exposure of credit cards or bankbooks occur often when a password is inputted to ATM/CD(Automated Teller Machines and Cash Dispenser), so particular attention is required when inputting a password. This study suggested a method to input a password safely to prevent stealing a glance at a password in case of the use of ATM/CD. The method is that users input a password when numbers are randomly displayed and disappear not to notice the password even though someone is next to or behind the users. As methods to input a password safely, the study verified safety by dividing the methods into a test of shoulder surfing, an intuitive perspective, and a theoretical analysis. In addition, the result of implementation to apply the method to ATM/CD shows that a percentage of acquiring a password from the attack of shoulder surfing is found to be lower than an existing method, so password exposure can be prevented.

Wear Characteristics for Rod and Nozzle of Jetting Dispenser Driven by Dual Piezoelectric Actuators Under High Frequency with Phosphor-containing Liquid (형광체 함유 용액 고속 토출 조건에서의 듀얼 압전 디스펜서 공이와 노즐의 마모 특성 평가)

  • Ha, Myeong-Woo;Lee, Kwang-Hee;An, Jun-Wook;Lee, Chul-Hee
    • Tribology and Lubricants
    • /
    • v.33 no.2
    • /
    • pp.52-58
    • /
    • 2017
  • An ultra-high precise ejection process is essential in a dispensing system for fabricating various precision parts such as a semiconductor, LED, and camera module. The size of such parts has been decreasing, which implies that a precise ejecting technique is required. A phosphor-containing liquid is ejected via a dispenser using dual piezoelectric actuators that are used for generating a high-speed dispensing mechanism. The rod and nozzle continuously contact in high speed to eject the liquid. However, the high-strength filler or phosphor in the liquid causes wear on the surfaces of the rod and nozzle during the dispensing process. As a result, the ejection reliability decreases as the wear on the surfaces increases. Therefore, it is necessary to estimate the wear characteristics of the rod and nozzle via an experiment and FE analysis. Reliability rests up to 1,000 cycles are conducted under relatively severe conditions. The flow rate and surfaces roughness of the rod and nozzle are measured in each ejection cycle. The surface images and wear volume are obtained before and after the tests and the ejection reliability is confirmed by measuring the flow rate of the liquid. The experimental results show that the ejection reliability is maintained up to 1,000k cycles; these results are validated by the simulation results.

Automatic Pill Dispenser Based on Arduino (아두이노 기반의 자동 알약 배급기)

  • Kim, Ji-Min;Kim, Min-Ji;Lee, Su-Jin;Kim, Sung-Chan
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.854-856
    • /
    • 2016
  • Nowadays, the interests about medical service and health concerting, in other words "Healthcare",are increasing. For healthcare, one of the most convenient and populated methods is taking nutritional supplements like vitamin everyday. According to social currency, we realize ' Automatic Pill Dispenser (APD)' in order to make the storage of pills easy and to help people take pills steadily periodically. First, the APD alerts at the time when the user sets. To prevent polluting pills, if the ultrasonic sensor recognizes user hands, and then after the APD distributes pills through activating the motor. If there are more the APDs, for example, hospitals can manage manpower more efficiently. Furthermore, If it is recorded which and how much pills are distributed automatically, It can be expected that people can take the pills more efficiently and healthfully.

  • PDF

A Study on Analysis and Design Improvement of Opening Angle of Duct Cap of Ice Dispenser for Refrigerator (냉장고 얼음 디스펜서 덕트 캡의 개방각도 해석 및 설계개선에 관한 연구)

  • Lee, Boo-Youn
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.5
    • /
    • pp.672-680
    • /
    • 2018
  • The opening angle of the duct cap assembly during the operation of a refrigerator ice dispenser was evaluated by transient structural analysis, and an improved design to maximize the opening angle was obtained. The opening angle of the existing design was found to be 78% of the upper limit. Several design modifications were proposed and analyzed to examine the effects of the design factors on the opening angle. As a result of the design modifications, the opening angle was improved by changing the lever material to a material with a high elastic modulus, moving the position of the support to the motor side, or increasing the lever shaft diameter. Considering the manufacturing cost of the new design, the design modification changing only the lever material was found to be the best because it does not require a change in the structure of the ice dispenser case. In conclusion, the opening angle can be improved by up to 95% of the upper limit value if the lever material is changed to an aluminum alloy. The methods and results presented in this study were found to be of great help in designing the duct cap assembly structure to facilitate the discharge of ice.

Operation Case of Mechanical Engineering Subject Applying Systematic Engineering Design Approach: Design of Golf Ball Dispenser (체계적 공학설계 방법론을 적용한 기계공학 교과목 운영 사례: 골프공디스펜서 설계)

  • Ryu, Sun-Joong
    • Journal of Practical Engineering Education
    • /
    • v.14 no.2
    • /
    • pp.235-244
    • /
    • 2022
  • In this study, a class operation case of an engineering design project targeting a golf ball dispenser, a commercial product, was presented. The project was carried out according to the systematic engineering design approach suggested by Kim Jong-won and W. Beitz. This method broadly divides engineering design into four stages: 'product planning → conceptual design → basic design → detailed design'. In particular, the conceptual design stage is divided into 'functional structure diagram → detailed working principle exploration → various design alternatives creation → optimal design selection'. In the conceptual design, the input/output of the golf ball dispenser was defined and a functional structure diagram was prepared for it. Through this process, it was possible to subdivide the functions of the product and to easily explore the working principle for each. The searched working principles are devised as various design alternatives by various combinations, and for each proposal, the advantages and disadvantages were compared with each other to derive the optimal design alternative. In the basic design, the prototype layout was completed through failure mode analysis and the actual prototype was manufactured using it. Through the entire process, students participating in the class will be able to design commercial products in a systematic way and experience manufacturing prototypes within the department of mechanical engineering curriculum.

Risk Assessment of Stationary Hydrogen Refueling Station by Section in Dispenser Module (고정식 수소충전소에서의 Dispenser Module 내 구역별 위험성 평가)

  • SangJin Lim;MinGi Kim;Su Kim;YoonHo Lee
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.29 no.1
    • /
    • pp.76-85
    • /
    • 2023
  • Demand for hydrogen as a renewable energy resource is increasing. However, unlike conventional fossil fuels, hydrogen requires a dedicated refueling station for fuel supply. A risk assessment of hydrogen refueling stations must be undertaken to secure the infrastructure. Therefore, in this study, a risk assessment for hydrogen refueling stations was conducted through both qualitative and quantitative risk assessments. For the qualitative evaluation, the hydrogen dispenser module was evaluated as two nodes using the hazard and operability (HAZOP) analysis. The risk due to filter clogging and high-pressure accidents was evaluated to be high according to the criticality estimation matrix. For the quantitative risk assessment, the Hydrogen Korea Risk Assessment Module (Hy-KoRAM) was used to indicate the shape of the fire and the range of damage impact, and to evaluate the individual and social risks. The individual risk level was determined of to be as low as reasonably practicable (ALARP). Additional safety measures proposed include placing the hydrogen refueling station about 100m away from public facilities. The social risk level was derived as 1E-04/year, with a frequency of approximately 10 deaths, falling within the ALARP range. As a result of the qualitative and quantitative risk assessments, additional safety measures for the process and a safety improvement plan are proposed through the establishment of a restricted area near the hydrogen refueling station.

A Study on the Variation of Unit Price of Hydrogen Fuel by Difference of Fuel Measuring Method (수소 충전소 연료계량방법의 차이에서 발생하는 연료단가의 상이점에 대한 고찰)

  • LEE, TAECK HONG;KANG, BYOUNG WOO;LEE, EUN WOUNG;BAE, CHUNG JIN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.28 no.3
    • /
    • pp.279-286
    • /
    • 2017
  • Korea government decides to build one hundred hydrogen refueling stations (HRS) until 2020 and tries to disseminate HRS and boosts HRS market in korea. Naepo HRS in chungnam province has been operated for last one full year of 2016 and recorded 2,520 times full charge for the hydrogen fuel cell powered vehicles and total 6,016 kg hydrogen fueling for the 25 units of hydrogen fuel cell powered vehicles. Raw fuel of hydrogen from tube trailer measured by pressure, converting into weight of hydrogen and shows 19.6% surplus with final charged weight by dispenser. This result is caused measuring errors. Measured charged errors between dispenser and Mass flow meter was determined 13.13%.