• 제목/요약/키워드: Dislocations

검색결과 411건 처리시간 0.027초

$L1_2$${\gamma}^{\prime}-Ni_3(Al,Ti)$ 규칙상 중에 불규칙 ${\gamma}$상의 석출거동에 관한 연구 (A Study on the Precipitation Behavior of Disordered ${\gamma}$ Phase in an $L1_2$ Ordered ${\gamma}^{\prime}-Ni_3(Al,Ti)$ Phase)

  • 한창석
    • 열처리공학회지
    • /
    • 제19권5호
    • /
    • pp.249-256
    • /
    • 2006
  • Structural studies have been performed on precipitation hardening found in $L1_2$ ordered ${\gamma}^{\prime}-Ni_3(Al,Ti)$ alloys using transmission electron microscopy. A uniform solid solution of ${\gamma}^{\prime}-L1_2$ ordered phase supersaturated with Ni can be obtained by solution annealing in a suitable temperature range. The ${\gamma}^{\prime}$ phase hardens appreciably by the fine precipitation of disordered ${\gamma}$. The shape of ${\gamma}$ precipitates formed during aging is initially spherical or round-cubic and grow into platelets as aging proceeds. High resolution electron microscopy revealed that the ${\gamma}$ precipitates are perfectly coherent with the matrix ${\gamma}^{\prime}$ as long as the ${\gamma}$-precipitates are plates. The loss of coherency initiates by the introduction of dislocations at the ${\gamma}/{\gamma}^{\prime}$ interface followed by the step formation at the dislocations. The ${\gamma}$ precipitates become globular after the loss of coherency. The strength of ${\gamma}^{\prime}-Ni_3(Al,Ti)$ increases over the temperature range of experiment by the precipitation of fine ${\gamma}$ particles. The peak temperature where a maximum strength was obtained shifted to higher temperature.

고에너지 P이온 주입한 실리콘에 형성된 격자 결함에 관한 고분해능 투과전자현미경 연구 (A High-Resolution Transmission Electron Microscopy Study on the Lattice Defects Formed in the High Energy P Ion Implanted Silicon)

  • 장기완;이정용;조남훈;노재상
    • 한국세라믹학회지
    • /
    • 제32권12호
    • /
    • pp.1377-1382
    • /
    • 1995
  • A high-resolution transmission electron microscopy study on the lattice defects formed in the high energy P ion implanted silicon was carried out on an atomic level. Results show that Lomer dislocations, 60$^{\circ}$perfect dislocations, 60$^{\circ}$ dislocation dipole and extrinsic stacking fault formed in the near Rp of as-implanted specimen. In the annelaed specimens, interstitial Frank loops, 60$^{\circ}$perfect disolations, 60$^{\circ}$dislocation dipoles, stacking faults, precipitates, perfect dislocation loops and <112> rodlike defects existed exclusively near in the Rp with various annealing temperature and time. From these results, it is concluded that extended secondary defects as well as the point defect clusters could be formed without annealing. Even at low temperature annealing such as 55$0^{\circ}C$, small interstitial Frank loops could be formed and precipitates were also formed by $700^{\circ}C$ annealing. The defect band annealed at 100$0^{\circ}C$ for 1 hr could be divided into two regions depending on the distribution of the secondary defects.

  • PDF

손상된 후경골건 감입에 의한 족관절 골절 및 탈구의 정복 실패: 증례 보고 (A Irreducible Ankle Fracture and Dislocation Due to Injured Tibialis Posterior Tendon Interposition: A Case Report)

  • 이준영;박이규;장현웅
    • 대한족부족관절학회지
    • /
    • 제21권2호
    • /
    • pp.70-74
    • /
    • 2017
  • Fractures and fracture-dislocations of the ankle are caused by a variety of mechanisms. In addition to fractures, injuries of soft tissue, such as ligaments, tendons, nerves, and muscles may also occur. Among these, a tibialis posterior tendon injury is difficult to be identified due to swelling and pain at the fracture site. It is difficult to observe tibialis posterior tendon injury on a simple radiograph; it is usually found during surgery by accident. There are some studies regarding irreducible ankle fracture-dislocations due to interposition of the tibialis posterior tendon; however, to the best of our knowledge, there has not been any report about interposition of injured tibialis posterior tendon. Herein, we report a case of an irreducible fracture-dislocation of the ankle due to injured tibialis posterior tendon interposition that was observed intraoperatively, interrupting the reduction of ankle fracture-dislocation. We obtained satisfactory clinical result after reduction of the trapped tendon, fracture reduction, and internal fixation; therefore, we are willing to report this case with the consent of the patient. This study was conducted with an approval from the local Institutional Ethics Review Board.

도심지 대심도 암반 굴착현장에서의 Face Mapping 적용사례 (A Case Study on the Field Monitoring of the Deep Rock Excavation Site in Urban Area)

  • 김태섭;김형민;조충식;강태승
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 세계 도시지반공학 심포지엄
    • /
    • pp.1307-1316
    • /
    • 2009
  • In this case, powerfulness quorum of destruction side which we have expected are supposed general limit value for rock floor when retaining of earth on the section of rock floor in the urban area. For digging in the urban area, there are a lot of dislocations to be disadvantage for safety of digging ants. The displacement of the pondside didn't converged with the phase of the excavation. Also, the speed of displacement got higher than the percentages of risk in the construction. So, we put into operation Face mapping for checking special quality of dislocations which appear on the digging ants. This results were used to decide a destruction in the case of the final excavation by analyzing with other results. It was possible to know the unstable distribution of a fault line in Face Mapping and to get powerful lens of a surface of discontinuity by tests indoors and outdoors. The results were also used to make a solution. Therefore, It's a successful example using the Partial TopDown for stable digging. And it is important that Face Mapping have to be practiced for solving the uncertainty of ground organization when digging design in the urban city.

  • PDF

High Temperature Creep Behavior in Al-Mg(Zn)-Fe Alloys

  • Bae, Chang-Hwan;Lee, Ju-Hee;Han, Chang-Suk
    • 한국재료학회지
    • /
    • 제20권1호
    • /
    • pp.37-41
    • /
    • 2010
  • Creep tests were conducted under a condition of constant stress on two aluminum-based alloys containing particles: Al-5% Mg-0.25% Fe and Al-5% Zn-0.22% Fe. The role of grain boundary sliding was examined in the plane of the surface using a square grid printed on the surface by carbon deposition and perpendicular to the surface using two-beam interferometry. Estimates of the contribution of grain boundary sliding to the total strain, $\varepsilon_{gbs}/\varepsilon_t$ reveal two trends; (i) the sliding contribution is consistently higher in the Al-Mg-Fe alloy, and (ii) the sliding contribution is essentially independent of strain in the Al-Mg-Fe alloy, but it shows a significant decrease with increasing strain in the Al-Zn-Fe alloy. Sliding is inhibited by the presence of particles and its contributions to the total strain are low. This inhibition is attributed to the interaction between the grain boundary dislocations responsible for sliding and particles in the boundaries.

외상 후 발생한 양측성의 견관절 잠긴 후방 탈구 - 증례 보고 - (Bilateral Traumatic Locked Posterior Dislocation of the Shoulder - A Case Report -)

  • 임종민;서정탁;안재민
    • Clinics in Shoulder and Elbow
    • /
    • 제12권2호
    • /
    • pp.226-231
    • /
    • 2009
  • 목적: 외상 후 발생한 양측성의 견관절 잠긴 후방탈구는 매우 드물며, 국내문헌에 이에 대한 수술적 치료에 대한 보고는 없다. 대사 및 방법: 외상 후 발생한 양측성의 견관절 잠긴 후방 탈구 1예에서 관혈적 정복술 후 우측에 대해 소전자 이전술, 좌측에 대해 견갑하건 이전술을 시행하였다. 결과 및 결론: 수술 후 24개월간 추시하여 만족스러운 임상적 및 방사선학적 결과를 얻어 문헌고찰과 함께 보고하는 바이다.

Irreducible Elbow Dislocation Associated with Hill-Sachs-like Lesion over the Capitellum

  • Weng, Hung-Kai;Chang, Wei-Lun;Yeh, Ming-Long;Su, Wei-Ren;Hsu, Kai-Lan
    • Clinics in Shoulder and Elbow
    • /
    • 제22권1호
    • /
    • pp.37-39
    • /
    • 2019
  • Irreducible dislocation of the elbow is an uncommon event. We present the case of a posterolateral elbow dislocation after a fall injury in a 67-year-old woman. A closed reduction performed in the emergency department was unsuccessful since the limited passive range of motion resulted in difficulty to perform longitudinal traction and flexion. Computed tomography images showed that the posterolateral aspect of the capitellum was impacted by the tip of the coronoid process, thus appearing similar to the Hill-Sachs lesion in the humeral head. Subsequent open reduction of the elbow revealed the dislocation to be irreducible since the tip of the coronoid process had wedged into a triangular Hill-Sachs-like lesion in the capitellum. The joint was reduced by providing distal traction on the forearm, and main fragments were disengaged using digital pressure. At the 3-month follow-up, the patient reported no dislocations, and had an acceptable range of motion. Thus, we propose that to avoid iatrogenic injury to the joint or other nearby structures, irreducible dislocations should not be subjected to repeated manipulation.

Improving Mechanical Properties of Wire Arc Additively Manufactured Ti-6Al-4V Alloy by Ultrasonic Needle Peening Treatment

  • Yi, Hui-Jun;Kim, Jin-Woo;Kim, Young-Lak;Shin, Sangyong
    • 한국재료학회지
    • /
    • 제31권5호
    • /
    • pp.245-254
    • /
    • 2021
  • Wire arc additive manufacturing (WAAM) is being considered as a technology to replace the conventional manufacturing process of titanium alloys. However, coarse β grains, which can extend through several deposited materials, result in strong textures and anisotropy. As a solution, we study the plastic deformation effects of ultrasonic needle peening (UNP) on the microstructure. UNP treated materials deform plastically and the dislocation density increases. Fine α+α' grains with low aspect ratio are observed in the UNP treated specimens. UNP treated WAAM Ti-6Al-4V alloys have higher strength and lower elongation than those characteristics of WAAM Ti-6Al-4V alloys. Due to UNP treatment, the z-axis directional specimens exhibit a greater effect of reducing elongation than do the x-axis directional specimens. The UNP treatment produces fine grains in proportion to the number of times UNP is performed, thereby increasing strength. UNP processes produce a large number of dislocations in the WAAM Ti-6Al-4V alloys, with the most dislocations being formed at the surface.

수지 골절-탈구 치료의 최신 지견 (The Current Concepts in Treatment of Fracture-Dislocations of the Finger)

  • 강호정;김지섭
    • 대한정형외과학회지
    • /
    • 제55권6호
    • /
    • pp.457-471
    • /
    • 2020
  • 수지는 복잡한 구조와 필수적인 기능을 가진 신체 부위로, 외상에 노출되기 가장 쉬운 부위이다. 수지 골절의 치료 원칙은 적절한 고정으로 골절부의 안정성을 획득하는 것과 안정성을 담보로 한 조기 관절 운동 간의 균형을 신중하게 결정하는 것이다. 치료에도 불구하고 합병증으로 강직이나 변형 등으로 인해 기능적, 미용적 문제가 되는 경우가 많다. 본 종설은 수지 골절 치료의 최신 지견을 소개하고, 치료가 어렵고 결과가 좋지 않은 것으로 알려진 관절면의 손상을 포함한 지절 관절 주위의 골절 및 탈구 위주로 정리하였으며, 치료 증례 소개와 합병증에 대한 접근 및 치료 순서로 기술하였다.

팔라디움전극에서 중수소의 전기분해와 수소와 격자결함의 반응에 관한 연구 (A Study on Electrolysis of Heavy Water and Interaction of Hydrogen with Lattice Defects in Palladium Electrodes)

  • Ko, Won-Il;Yoon, Young-Ku;Park, Yong-Ki
    • Nuclear Engineering and Technology
    • /
    • 제24권2호
    • /
    • pp.141-153
    • /
    • 1992
  • 상온핵융합의 실험적 검증을 위하여 가공조건 및 기하학적조건이 다른 7종류의 팔라디움전극을 사용하여 24~28시간, 전류밀도 83~600 mA/$\textrm{cm}^2$의 조건하에 전기분해를 실시하였다. 상기조건 하에서 삼중수소의 농축에 기인한 분리팩타(separation factor)를 측정하였고 핵융합의 부산물일수도 있는 삼중수소 증가량을 측정하였다. 또한 초과열 계 산과 관련된 K(net Faradic efficiency)를 측정하여 산소/중수소 가스의 재결합정도를 조사하였다. 양전자소멸측정장치 및 일정체적 가스주입장치를 이용하여 팔라디움전극에서 격자결함과 수소의 반응 및 거동에 대하여 조사하였다. 전기분해하는 동안 삼중수소 농축현상이 관찰되었으나 핵융합의 증거가 될만한 삼중수소양은 검출되지 않았다. 한편 산소/수소 가스의 재결합 정도는 32%로 나타났다. 이는 재결합과정이 발열반응이므로 전기분해과정에서 핵반응과 관계없이 초과엔탈피가 발생할 수 있음을 의미한다. 양전자소멸측정장치를 이용하여 양전자수명, 양전자소멸밀도, P/W 및 R 파라메터의 측정을 통하여 전극의 격자결함(전위 및 공공)에 수소가 집적 (trap)되며 수소집적은 공공에서 보다 전위에 약간 더 선호하는 것으로 나타났다. 전극의 수소화물형성에 수반하여 대부분 전위가 발생한 것으로 나타났다. 또한 팔라디움수소화물의 등시소둔실험을 통하여 소량의 미소공동 형태의 결함이 존재하는 것으로 추정하였고 그 결함의 크기는 수 $\AA$정도인 것으로 생각된다.

  • PDF