• 제목/요약/키워드: Disinfection rate

검색결과 164건 처리시간 0.024초

소규모 오수처리를 위한 전기화학적 방법에 의한 대장균 소독에 관한 연구 (A Study on Escherichia Coli Disinfection by the Electrochemical Method for Small Sewerage System)

  • 박영식;정노성;김동석
    • 한국환경과학회지
    • /
    • 제16권4호
    • /
    • pp.441-447
    • /
    • 2007
  • This study was carried out to investigate the effect of electrochemical (EC) disinfection of artificial wastewater contaminated by Escherichia coli culture. Circulated batch type electrochemical disinfection system using three plates electrodes was used. Also, the several factors (pH, ORP, DO, temperature, current, conductivity) were measured in order to investigate the fundamental design factor in the EC disinfection system. It was demonstrated that the EC process was highly effective for wastewater disinfection. At the constant voltage, the disinfection efficiency was increased according to time. The disinfection efficiency and current increased as the increase of voltage. The variation of conductivity was a little related to the variation of CFU (colony forming units). The differences in disinfection efficiency according to the ice pack and the variation of electrodes were not occurred. The EC disinfection efficiency and current increased according to the increase of circulating flow rate.

Disinfection Characteristics of Waterborne Pathogenic Protozoa Giardia lamblia

  • Kim, Kyongjoo;Wooksun Hong;Lee, Kisay
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • 제6권2호
    • /
    • pp.95-99
    • /
    • 2001
  • Giardia lamblia is a parasitic protozoa which is transmitted in the form of a cyst through untreated water and also treated drinking water. Since its presence in water has led to frequent outbreaks of giardiasis and death in many countries, the removal and disinfection of this protozoan cyst from the water supply are of great concern for public health. This study examined the disinfection characteristics of G. lamblia cysts isolated from a Korean patient with giardiasis. When using sodium hypochlorite including 5 or 10 ppm chlorine, the killing rate was initially rapid, however, the disinfection slowed down and a 3log reduction could not be achieved even after 2h. The disinfection effectiveness was also reduced at a lower temperature, thereby implying that the risk o a giardiasis outbreak will be higher in the winter season. A CT (concentration$.$time) curve was constructed based on the results with sodium hypochlorite for use in designing and predicting disinfection performance. The organic chlorination disinfectant SDIS (sodium dichloroisocyanurate) produced a lower pH and a much higher residual effect than sodium hypochlorite. The disinfection of cysts by SDIC continued steadily throughout 2h of contact, although the initial killing rate was lower than that with sodium hypochlorite.

  • PDF

초음파와 자외선(UV) 동시 적용이 가정용 가습기 내 살균에 미치는 시너지 효과에 대한 반응속도론적 연구 (Kinetic examination on synergistic effect of co-use of ultrasonic wave and ultraviolet radiation on bacterial disinfection in a household humidifier)

  • 김성아;김지현;이민주;김자연;정우식;박준홍
    • 상하수도학회지
    • /
    • 제35권3호
    • /
    • pp.227-235
    • /
    • 2021
  • This study examined the effect of ultraviolet (UV) application on bacterial disinfection in a commercialized humidifier using ultrasonic wave (UW). To accurately examine disinfection kinetics in tap-water condition, tap-water was sterilized using a filter, and then inoculated with pure cultures of E. coli and P. putida with known viable counts. The disinfection kinetic characteristics were experimentally compared when UV alone, UW alone, and UW+UV together were applied in disinfecting the added bacteria in the commercialized humidifier. When UV alone was applied, bacterial disinfection kinetics followed a first-order decay reaction, and showed an approximately 10-time weaker disinfection compared to the typical UV disinfection in water treatment or wastewater treatment. When UW alone was applied, bacterial disinfection kinetics followed a second-order decay reaction with a low disinfection rate constant of 0.0002 min-1(CFU/mL)-1. When UV and UW were applied together, however and interestingly, the disinfection rate constant (0.0211 min-1(CFU/mL)-1) was approximately 100 times increased than that for the UW alone case. These results revealed that the co-use of UV and UW can provide synergistic effect on bacterial disinfection in a tap-water condition in household humidifiers.

벨트형 손소독제 활용의 효과 평가: 임상간호사의 손소독 수행 정도와 만족도를 중심으로 (The Evaluation of Effectiveness of Belt-type Hand Sanitizers in Clinical Nurses: Focusing on the performance of hand disinfection and the satisfaction)

  • 조윤주;이인숙
    • 디지털융복합연구
    • /
    • 제18권3호
    • /
    • pp.275-285
    • /
    • 2020
  • 본 연구는 임상간호사들의 벨트형 손소독제 활용에 대한 손소독 수행정도와 수행률, 손소독제 사용 만족도에 대한 효과를 파악하고자 수행된 연구이다. 연구수행을 위해 단일군 전후 유사실험 설계를 이용하였으며, 벨트형 손소독제 활용에 대한 효과평가는 손소독 수행 정도, 손소독 수행률, 손소독제 사용에 대한 만족도로 자가보고형 설문지를 이용하여 측정하였다. 연구 대상자는 일 지역의 종합병원 병동의 임상간호사 50명을 대상으로 하였으며, 수집된 자료는 SPSS 23.0 프로그램을 이용하여 분석하였다. 연구결과, 벨트형 손소독제 사용 후의 손소독 수행 정도, 손소독 수행률, 손소독제 사용 만족도가 유의하게 높은 것으로 나타났다. 본 연구를 통해 벨트형 손소독제는 손소독 수행정도와 손소독 수행률을 향상시킬 수 있는 효과적인 방법임을 확인하였다. 따라서 임상실무에서 벨트형 손소독제를 활용한다면, 손소독 수행 정도와 수행률 향상에 기여할 수 있을 것이다.

유입수의 기계적 여과 후 자외선 살균에 의한 넙치 치어의 질병 저감 사례 연구 (Effect of UV disinfection following mechanical filtration for influent seawater on decrease in disease outbreak of juvenile olive flounder (Paralichthys olivaceus))

  • 강봉조;장영환;전봉근;박범희;신동혁
    • 한국어병학회지
    • /
    • 제28권3호
    • /
    • pp.125-131
    • /
    • 2015
  • 본 연구는 기계적 여과 후 자외선 살균처리한 양식장 유입수의 살균효율과 넙치 치어의 질병저감 효과를 평가하였다. 유입해수의 살균효율은 99.27%로 조사되었고, 기계적 여과 및 UV 살균처리 해수로 4개월 동안 사육한 넙치 치어는 대조구에 비하여 20~30%의 폐사율 저감효과가 관찰되었다.

LED 광원 UV에 의한 대장균(E. coli) 소독의 속도론 해석 (Kinetic analysis of E. coli disinfection using UV-LED)

  • 김경래;장인성
    • 상하수도학회지
    • /
    • 제35권6호
    • /
    • pp.489-496
    • /
    • 2021
  • Water disinfection using UV-LED(Light emitting diode) has many advantages, such as smaller footprint and power consumption as well as relatively longer lifespan than those of conventional mercury-UV lamps. Moreover, UV-LED disinfection is considered an environmentally benign process due to its mercury-free nature. In this study, disinfection using an LED module emitting 275nm UV was carried out. 384 UV-LEDs were put into a cylinder tube with a capacity of 1.7 liters. The UV intensity of the UV-LED module was controlled from 1.7 to 8.4 mW/cm2. The disinfection efficiency for the model microorganism solutions(E. coli ) was monitored. As the UV intensity(I) and contact time(t) varied, inactivation of the microorganisms from 2 to 4-log-removals(i.e., 99 to 99.99% of disinfection efficiency) was achieved. Disinfection using UV-LED was followed to 1st order reaction and the reaction rate constant, k was determined. In addition, the relationship between UV intensity(I) and contact time(t) in order to obtain 99.99% of disinfection efficiency was modeled: I1.2·t= 460, which indicates that the product of UV intensity and contact time requiring 4-log-removals is always constant.

멀티 플라즈마 반응기를 이용한 E. coli 소독 (E. coli Disinfection Using a Multi Plasma Reactor)

  • 김동석;박영식
    • 한국환경보건학회지
    • /
    • 제39권2호
    • /
    • pp.187-195
    • /
    • 2013
  • Objectives: For the practical application of the dielectric barrier discharge plasma reactor, a plasma reactor able to manage large volumes of water is needed. This study investigated the possibility of the practical application of a multi-plasma reactor which is a scaled-up version of a single plasma reactor. Methods: The multi-plasma reactor consists of several high-voltage transformers and plasma modules (discharge, ground electrodes and quartz dielectric tubes). The effects of water characteristics such as voltage (30-120 V), air flow rate (1-5 l/min), number of high-voltage transformers and plasma modules, and water quality on Escherichia coli (E. coli) disinfection and decrease of COD and $UV_{254}$ absorbance were investigated. Results: The experimental results showed that at a voltage of over 80 V, most of the E. coli were disinfected within 90 seconds. E. coli inactivation was not affected by the air flow rate. E. coli disinfection in the multiplasma process showed the traditional log-linear form of the disinfection curve. E. coli inactivation performance by transformer 3-Reactor 5 and transformer 3-Reactor 3 were similar. The disinfection performance of the UV process was affected by artificial sewage water. However, the plasma process was less affected by the artificial sewage within the standards for effluent water quality. Conclusions: Disinfection performance with several low voltages and plasma modules of three to five in number applied to the plasma process was higher than that concentrating a small amount of high voltage through a single plasma reactor. Removal of COD, $UV_{254}$ absorbance, and E. coli disinfection with the plasma process were better than with the UV process.

물리·화학적 공정을 이용한 해수 동물성 플랑크톤 Aretemia sp.의 소독 (Inactivation of Seawater Zooplankton Aretemia sp. using Physical and Chemical Processes)

  • 정창;김동석;박영식
    • 한국환경과학회지
    • /
    • 제24권9호
    • /
    • pp.1181-1188
    • /
    • 2015
  • In this study, we discussed about the application of the single physical and chemical treatment processes and the physical-chemical complex treatment processes on the inactivation of Artemia sp. in order to satisfy the USCG Phase II (United States Coast Guard). The results showed that initial disinfection rate of ultrasonic process in single batch process is higher than that of electrolysis. However, the inactivation rate showed slower than electrolysis. The inactivation rate of Artemia sp. on the single continuous treatment process ranked in the following order: homogenizer > electrolysis > ultrasonic process. Inactivation rate of Artemia sp. in continuous homogenizer-electrolysis complex process was reached at 100% immediately. A synergistic effect of ultrasonic-electrolytic complex process was found to be a small. The order of processes in a complex process did not affect the disinfection performance.

초음파 검사에 의한 수중의 살균처리 (Disinfection of Water by Ultrasonic Irradiation)

  • 손종렬;유병성
    • 환경위생공학
    • /
    • 제14권1호
    • /
    • pp.54-61
    • /
    • 1999
  • The industrial techniques of ultrasound have been used in the various fields, such as cleaning, medical surgery, emulsification, cell disruption etc. Especially the application of cell disruption was interested in the field of disinfection process in water by ultrasonic irradiation. It has been recognized that the ultrasounds are irradiated in aqueous solution, cavitation bubbles are generated and shock waves of high temperature and pressure are emitted as the bubbles are developed and finally broken, which function as a energy source to promote reaction efficiencies of various kinds of chemical reactions such as disinfection reaction in water. Therefore, this study was performed to apply the ultrasound for the disinfection method of infected drinking raw water and to discuss the limiting factors such as pH, sample volume and reaction temperature influenced on the removal efficiency of E. coli from experimental analysis of the results obtained in bench-scale plant. For the experiments to measure the influence of reaction parameters in the ultrasonic disinfection process, escalated reactivity of aqueous solutions was excellent when pH in aqueous solution was low, and sample volume was small. On the contrary, the reactivity of disinfection became elevated when reaction temperature was high. It was found that the rate constant of disinfection reaction was applied by Chick's law, reaction kinetics of Chick's law was irreversible and pseudo-first order at all the tested conditions.As a conclusion it appeared that the technology using ultrasonic irradiation can be applied to the treatment of disinfection in infected water which are difficult to be treated by conventional methods.

  • PDF

E. coli 불활성화를 위한 단일 소독 공정의 비교 (A Comparison of Single Disinfection Process for Inactivation of E. coli)

  • 김동석;송승구;박영식
    • KSBB Journal
    • /
    • 제25권1호
    • /
    • pp.25-32
    • /
    • 2010
  • This study was carried out to evaluate the performance of three kinds of single process (electrolysis, UV and ultrasonic process) for the purpose of disinfection of Escherichia coli in water. Among the five kinds of electrode material, disinfection performance of Ir electrode was higher than that of the other electrodes. The order of disinfection performance for E. coli in single process lies in: electrolysis > UV $\gg$ ultrasonic process. Performance of the three single processes was increased with the increase of the electric power. Disinfection efficiency of the three processes was increased with the decrease of the pH. Disinfection of the UV process were decreased by the increase of NaCl dosage and air flow rate. However, ultrasonic process was not affected above two parameters. OH radical was not produced in UV and ultrasonic process. E. coli disinfection of the electrolysis process was well agreed with RNO degradation tendency, except pH.