• Title/Summary/Keyword: Disinfection by Product

Search Result 44, Processing Time 0.027 seconds

Removal of Nitrosomethylamine at Extremely Low Concentration by Powdered Activated Carbon (분말활성탄을 이용한 극미량 농도 Nitrosomethylamine의 흡착 제거)

  • Lee, Sung-Bum;Yoon, Yeo-Min;Choi, Chang-Kyoo;Kim, Moon-Il
    • 한국방재학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.413-416
    • /
    • 2008
  • Recently, the results of vital tissue test showed that nitrosodimethylamine (NDMA) as a disinfection by-product (DBP), could be regarded as a carcinogen because a tumor was observed in organs. U.S.EPA indicated 0.7 ng/L as exposure concentration of NDMA based on a risk assessment target with a lifetime cancer risk of $10^{-6}$. Several recent studies have shown that UV oxidation could remove NDMA. However, UV oxidation is uneconomical and can reform NDMA after treating. In addition, the treatment mechanism of adsorption has not been founddue to the uncertainty of NDMA pathway. In addtion, NDMA has a radioisotope $^{14}C$-labeled which can be analyzed at low concentration of NDMA by Liquid Scintillation Counter (LSC). This study has investigated NDMA determination using LSC at an extremely low range from 1 to 100 ng/L and NDMA removal by powdered activated carbon (PAC) adsorption. For $^{14}C$-NDMA by LSC, the highest correlation over 99% between count number and NDMA concentrationwas obtained with possibility of $^{14}C$-NDMA concentration up to 1 ng/L. In the presence of PAC ranging from 50 to 10,000 mg/L, $^{14}C$-NDMA was removed from 18% to 97% for Sigma-Aldrich corporation (S-A co.) and from 9% to 93% by PAC for Daejung corporation (Dj co.). Hence it was found that the removal efficiency by PAC adsorption could vary depending on PAC types from different companies. For PAC adsorption capacity of $^{14}C$-NDMA using the Freundlich isotherm, $K_f$ and 1/n of PAC from S-A co. were $2.67\times10^{-3}$ ng/mg and 1.009, while those of PAC from Dj co. were $1.30\times10^{-3}$ ng/mg and 0.994, respectively. Thus, PAC from S-A co. showed twice higher adsorption capacity than Dj co.

  • PDF

Detection of Extremely Low Concentration Compound and Adsorption by Activated Carbon (극미량 농도 물질의 측정 및 활성탄 흡착 처리)

  • Lee, Sung-Bum;Yoon, Yeo-Min;Choi, Chang-Kyoo;Jung, Jin-Wook;Lee, Yong-Woo;Park, Se-Yong;Kim, Moon-Il
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.9
    • /
    • pp.913-917
    • /
    • 2008
  • Since the difficulty of analysis at low concentration and the uncertainty of the removal mechanism for Nitrosodimethylamine (NDMA) have been reported, this study has detected extremely low concentration $^{14}$C-NDMA using the LSC(Liquid Scintillation Counter) and tested NDMA removal by Powdered Activated Carbon(PAC). The results showed the highest correlation over 99% when samples were measured with the mixture ratio of sample to scintillation liquid of 10 : 10 and at the detection time of 10 min. For $^{14}$C-NDMA removal by the PACs(S-A(Sigma-Aldrich co.) and Dj(Daejung co.)) raging from 50$\sim$10,000 mg/L, $^{14}$C-NDMA was removed over 90% by adsorption treatment. In addition, S-A showed twice greater adsorption capacity than that of Dj. However, the required PAC amount for $^{14}$C-NDMA removal was higher than that of other amine compounds.

Photometric Determination of Chlorite ion by Flow Injection Analysis (흐름주입 분석에 의한 아염소산 이온의 분광광도법 정량)

  • Choi, Yong Wook;Lee, Su Young;Kim, Mi Kyung;Park, Sung Ho
    • Journal of the Korean Chemical Society
    • /
    • v.44 no.6
    • /
    • pp.556-562
    • /
    • 2000
  • The determination of chlorite ion by flow injection analysis(FIA) with iodometric UV detection were investigated. Under rather acidic condition, chlorite ion react with iodide ion to form iodine and itself is reduced to chloride ion. The chlorite ion was determined indirectly by measuring absorbance of yellow colored iodine at 370 nm. The lengths of the mixing coil and the reaction coil, the pH of the acid stream, the concentration of the iodide ion, the injection loop volume, temperature, and flowrate were optimized as parameters for selectively determining a sort of inorganic disinfection by-product, chlorite ion by using FIA-UV detection setup. Masking agents for removing oxidants or interferences from the prepared water were tested. Independent calibration curve presented linear range of 0.002-0.2 mg/L for chlorite ion with a correlation coefficient of 0.999 or better. The limit of detection(LOD) was 0.18 ${\mu}g/L$ for chlorite ion.

  • PDF

Development of a Hospital Foodservice Facility Plan and Model based on General Sanitation Standards and RACCP Guidelines (병원급식에 일반위생관리기준과 HACCP 제도 적용을 위한 시설모델 개발)

  • 이정숙;곽동경;강영재
    • Korean journal of food and cookery science
    • /
    • v.19 no.4
    • /
    • pp.477-492
    • /
    • 2003
  • The purposes of the study were to establish HACCP-based standards and guidelines for conducting a plan review to build, or renovate, hospital food service establishments, and ensure the safety of foodservice and reduce the risk of food borne illness. The scope of the study included suggestion for the planning of hospital foodservice facilities: layout, design, equipment and modeling. The results of this study can be summarized as follows: 1) The development of a foodservice facility plan based on the results of a survey, literature reviews and the results of interviews with foodservice managers from 9 general hospitals. This was composed of operational policies in foodservices, layout characteristics, space allocation, selection, design, specification standards for equipment and the construction principles of foodservice facilities. 2) Two foodservice facility models were developed, one for general hospitals with 900 beds (2,000 patients and 2,500 employee meals per day) and the other for general hospitals with 300 beds (600 patients and 650 employees meals per day). 3) The suggested kitchen space requirements for the foodservice facility models were 341.2 ㎡ (W 17,100mm x L 23,700mm) and 998.8㎡ (W 35,600mm x L 32,800mm) for the 300 and 900 beds hospitals, respectively, with both designs being rectangular. The space requirements for the equipment, in relation to the total operational area, in terms of ratios were 1:3.5 and 1:3.8 for the 300 and 900 beds hospitals, respectively. The recommended space allowances per bed for the developed foodservice facility models were 1.15 ㎡ and 1.11 ㎡ for the 300 and 900 beds hospitals, respectively, which were increased by more than 30% compared to those suggested in the precedent study, and considered appropriate for the implementation of the HACCP system. 4) The hospital foodservice facilities plans and models were developed based on the general sanitation standards, guidelines and the HACCP system, and included foodservice facility layout, product flow, physical separation between contaminated and sanitary areas, foodservice facility specifications with a 1/300 scale for a 300 bed, and a 1/400 scale for a 900 beds blueprint. 5) The main features of the developed foodservice facility plans and models were; physical separation between contaminated and sanitary areas to prevent cross contamination, product flow in one direction from the arrival of the raw material to the finished product, and separation of different work areas and the process of receiving & preparation of products, refrigeration & storage, cooking, assembly, cleaning & disinfection, employee areas and janitorial facilities. The proposed models from this study were presented as examples for those wanting to build, or renovate, their facility for the production of foods.

The Removal Characteristics of THM Formation Potential According to the Changes of Bromide Concentration of Influent Water in BAC Process (생물활성탄 공정에서 계절별 유입수의 $Br^-$ 농도변화에 따른 THM 생성능 구성종별 제거 특성)

  • Son, Hee-Jong;Yoo, Pyung-Jong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.5
    • /
    • pp.378-381
    • /
    • 2009
  • The purpose of this research is the evaluation of removal efficiency of THMFP in BAC. The changes of four types of THMFP and total THMFP were examined in the influent and effluent of BAC filter from March to December in 2008. It turned out that the amounts of brominated THMFP were obviously higher in winter and autumn compared to the spring and summer, which also resulted in an increase of the total-THMFP levels during winter and autumn. In addition, long-term running of BAC filter shows the good removal function of chloroform formation potential, but not brominated THMFP; with further bromination, this function was declined, as it shows the formation of bromoform in BAC filter during October and December. These results were caused by changing of the proportion of $Br^-$/DOC.

Microbial Contamination Level and Disinfection Effect of Electrolyzed Water in the Production Process of Dried-Laver Pyropia sp. (마른김(Pyropia sp.) 가공 공정에서의 미생물 오염도 및 전기분해수의 처리 효과)

  • Cho, Jong-Lak;Hong, Do-Hee;Kim, Young-Mog;Kim, Hyun-Joong;Kim, Jeong-Mok
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.55 no.5
    • /
    • pp.662-669
    • /
    • 2022
  • The purpose of this study is to test the effects of electrolyzed water treatment on dried-laver Pyropia sp. processing facilities to control microbial contamination. Following the progression of the process to the next step, as well as during the lapse between process operating hours, the contamination level of total viable cell counts (TVC) and total coliform (TC) of laver increased. The TVC increased during the aging step, and after the molding-drying steps were completed, it increased by approximately 2.0 log CFU (colony forming unit)/g. Freshwater used for processing in April had a TVC of 4.31 log CFU/mL, which was more polluted than 2.61 log CFU/mL of seawater. Electrolyzed water was used to treat the sponge used in the laver-molding process, which resulted in a 2 log CFU/mL decrease.The TVC of dried-laver decreased by 1 to 2 log CFU/g when electrolyzed water was applied to the process. In conclusion, application of electrolyzed water in dried-laver processing was shown to be effective in reducing the microbiological contamination of the final product.

Removal of Dissolved Organic Matters in Drinking Water by GAC adsorption using RSSCT (RSSCT를 이용한 GAC의 상수원수 내 용존유기물질 제거)

  • Kim, Young Il;Bae, Byung Uk
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.5
    • /
    • pp.727-736
    • /
    • 2006
  • Granular activated carbon (GAC) has been identified as a best available technology (BAT) by the United States Environmental Protection Agency (USEPA) for removal disinfection by-product (DBP) precursors, such as dissolved organic carbon (DOC) and dissolved organic nitrogen (DON). Rapid small-scale column test (RSSCT) were used to investigate four types of carbon (F400, Norit1240, Norit40S, and Aquasorb1500) for their affinity to absorb natural organic matter (NOM). DOC, $UV_{254}$, and Total dissolved nitrogen (TON) concentrations were measured in the column effluent to track GAC breakthrough. DOC and $UV_{254}$ breakthrough occurred at around 3500 bed volumes (BVs) of operation for all GACs investigated. The $UV_{254}$ breakthrough curves showed 33% to 48% at 8000 BVs, when the DOC was 48% to 65%. All GACs showed greater removal in DOC than $UV_{254}$. The NORIT1240 GAC was determined to have the highest adsorption capacity for DOC and $UV_{254}$. The removal of nitrate (NOTN) had not broken through over BVs. The initial TON breakthrough curves were started around 50%, when the DOC breakthrough was only 10 % at 500 BVs. The curves were gradually increased after 3500 BVs and approximately 69% through 81% of TON breakthrough occurred at 8000 BVs. All of the GACs were able to remove TON, in the case of this investigation the majority of the TON was present as DON. Because nitrate nitrogen was seldom removed and ammonium nitrogen ($NH_3-N$) was not detected in the effluent from RSSCTs even though raw water. The carbon usage rate of DOC was from 2 to 6 times less than that of TON. The NORIT1240 GAC demonstrated the best performance in terms of DOC removal, while the F400 GAC was best in terms of TON removal. Excitation emission matrix(EEM) analysis was used to show that GAC adsorption successfully removed most of Humic-like DOC and Fulvic-like DOCs. However, soluble microbial product(SMP)-like DOC in the absence of raw water were detected in the NORIT40S and Aquasorb1500 GAC. The authors assumed that this results is due probably to the part of GAC in the RSSCT which was converted into biological activated carbon(BAC). To compare with organics removal by GAC according to preloading, the virgin GACs had readily accessible sites that were adsorbed DOC more rapidly than preloaded GACs, but the TDN removal had not showed differences between those GACs.

Formation and Removal of Trihalomethanes based on Characterization of Hydrophobic and Hydrophilic Precursors (전구물질의 소수성 및 친수성 특성에 따른 트리할로메탄의 생성과 제거에 관한 연구)

  • Jeon, Heekyung;Kim, Junsung;Choi, Yoonchan;Choi, Haeyeon;Chung, Yong
    • Journal of Korean Society on Water Environment
    • /
    • v.24 no.1
    • /
    • pp.123-128
    • /
    • 2008
  • The Dissolved Organic Carbon (DOC) existing in a water includes both hydrophobic and hydrophilic substances however, most of the discussion focuses on hydrophobic substances. The hydrophobic fraction was easily removed by absorption or coagulation more than hydrophilic fraction. Therefore, control of the hydrophilic fraction is very important in water treatment process. This study is to determine the variation of DOC, the removal efficiency of DOC, and Trihalomethane formation potential (THMFP) after each stage of water treatment process by fractionating Natural Organic Matters (NOM) into hydrophobic and hydrophilic substance. DOC from raw water was fractionated at acidic pH (pH<2) using XAD 8 resin column, into two fraction : hydrophobic substance (i.e. humic substance) adsorbed on XAD 8 and hydrophilic substance which represent the organics contained in the final effluent. THMFP was carried out according to the following set condition: Cl2/DOC=4 mg/mg, incubation at $25^{\circ}C$ in darkness, pH 7 adjust with HCl or NaOH as necessary, and 72hour-contact time. THMs analyzed in this study were chloroform, bromodichloromethane, dibromochloromethan, and bromoform. Sewage was almost evenly split between the hydrophobic (56%) and hydrophilic fraction (44%). But, Aldrich humic substance (AHS) was found to contain less hydrophilics (14%) than hydrophobics (86%). The formation of THMs may depend on the source which is characterized by the composition of organic matters such as AHS and sewage. The THMFP yield of sewage and AHS were assessed as follows. The value of the THMFP reaction yield, AHS $172.65{\mu}g/mg$, is much higher than that of sewage $41.68{\mu}g/mg$. This illustrates possible significant difference in THMFP according to the component type and the proportion of organic matter existing in water source. Apparently AHS react with chlorine to produce more THMFP than do the smaller molecules found in sewage. Water treatment process may reduce THMFP, nevertheless residual DOC (the more hydrophilic substance) has significant THMFP. Further reduction in organic halide precursors requires application of alternative treatment techniques.

Application of HACCP for Hygiene Control to Jabchae in Team Foodservice Facility (잡채를 중심으로 한 단체급식시설의 위생개선을 위한 HACCP 적용에 관한 연구)

  • 이선애;박경준;강성태
    • Culinary science and hospitality research
    • /
    • v.9 no.4
    • /
    • pp.81-97
    • /
    • 2003
  • The purpose of this study was to evaluate hazard factors in the steps of production, holding and assembly and service of jabchae that were served by contracted management in school meal foodservice. And method of control with the Hazard Analysis Critical Control Point (HACCP)program was suggested. The hazard factors in jabchae product had come from the temperature, time, growth of microbiological equipment and utensils. Almost of raw materials, prepreparation and storage, cooking, holding, serving established the critical control point. It has shown that the microbiological quality of raw materials for jabchae was a little inferior at the time of receiving based on the total plate count(10$^3$∼10 $^{5}$ ), coliform(0∼10$^3$). However microbiological quality become acceptable level by washing and a few disinfection method. Microbiological growth has increased in 3hr at room temperature up to 5.1${\times}$10$^2$ after preparation of jobchae. In conclusion, it is extremly important to reduce hoiding and serving time and to avoid treating food within the danger zone for food safeness. In addition, the prevention of cross-contamination during mixing the ingredients with improper equipment and with insanitary treatments by workers was also important to keep the food safe in this foodservice facility.

  • PDF

Microbiological Hazard Analysis for HACCP System Application to fermented milk (발효유류의 HACCP 시스템 적용을 위한 미생물학적 위해 분석)

  • Park, Seong-Bin;Kwon, Sang-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.1
    • /
    • pp.438-444
    • /
    • 2015
  • The aim of this research was to apply a HACCP system (Hazard Analysis Critical Control Point) to fermented milk. The main ingredients of fermented milk, work facilities and workers were obtained from a company named YD, which is located in Seobuk-gu, Cheonan-si between November 5 2013 to April 13, 2014. A manufacturing process chart was prepared by referring to the manufacturing process of fermented milk manufacturers in common. The manufacturing process chart was made with raw materials; Raw milk, High Fructose Corn Syrup, Oligosaccharides, Lactic Acid bacteria and Subsidiary ingredients, Warehousing of packaging materials, Storage, Input, Preheating, Mixing, Homogeneity, Sterilization, Precooling, Culture, Filtration, In packaging, Out packaging, Storage, and Consignment, as listed Table 1. The results of the microbiological hazard analysis on the raw materials was safe after sterilization($90^{\circ}C{\pm}5^{\circ}C$, $35{\pm}3min.$) On the other hand,a microorganism test of an environment and workers suggested that the microbiological hazard should be reduced through systematic cleaning and disinfection accompanied by improved personal hygiene based on hygienic education on workers and the management of microorganisms in air.