• Title/Summary/Keyword: Disinfection Process

Search Result 205, Processing Time 0.025 seconds

The Study of Characteristics of Electrolytic Water (전해수의 특성에 관한 연구)

  • Lee, Chan-Woo;Bae, Kie-Seo
    • Textile Coloration and Finishing
    • /
    • v.18 no.6 s.91
    • /
    • pp.43-48
    • /
    • 2006
  • Electrolytic water(EW), studied in recent decades in the Japan, Russia and United State of America, have shown promise as a method of disinfection whereby low levels of free chlorine, sodium hypochlorite, or hypochlorous acid may be produced in situ in Nacl-containing solution. These methods have shown promise in destruction of microorganisms in medical, dental environment, and in the agriculture and food industry. A recently EW treatment system was evaluated for reducing scouring agent and other surfactants in the washing and scouring process of textile industry Unfortunately, there is, to my knowledge, no serious studies of the properties of EW for textile industry In order to study the characteristics of EW and confirm the possibility of applications in textile industry processes, the pH, surface activity, penetration force, surface tension, and contact angle of EW was measured under various conditions. In general terms, What all this shows is that there is fundamental difference between the properties of EW and that of distilled water.

Study on CFD Methodology for a Open Channel Type UV Reactor (전산유체역학을 활용한 개수로형 UV소독장비의 해석기법 연구)

  • Hwang, Woochul;Bak, Jeong-Gyu;Kim, Hyunsoo;Lee, Kunghyuk;Cho, Jinsoo
    • The KSFM Journal of Fluid Machinery
    • /
    • v.18 no.2
    • /
    • pp.54-59
    • /
    • 2015
  • The performance of UV reactor which is used in water treatment is strongly affected by UV fluence rate and water flow in the UV reactor. Therefore, CFD tools are widely used in designing process of UV reactors. This paper describes the development of a computational fluid dynamics (CFD) methodology that can be used to calculate the performance of open channel type UV reactor used in wastewater treatment plant. All computations were performed using commercial CFD code, CFX, by considering three dimensional, steady, incompressible flow. The Eulerian-Eulerian multi-phase method were used to capture the water-air interface. The MSSS model, provided by UVCalc3D, was used to calculate the UV intensity field. The numerical predictions and calculated UV Dose were compared with experimental dataset to validate the CFD methodology. The reactor performance based on MS2 log reduction was well matched with measurements within 6%.

Influence of Different Mixing Types on the Removal of Natural Organic Matter in Water Treatment (정수처리시 천연유기물질의 제거에 대한 급속혼화유형의 영향)

  • Kim, Hyun-Chul;Yu, Myong-Jin;Lee, Seock-Heon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.3
    • /
    • pp.370-377
    • /
    • 2005
  • Dispersion of coagulant should be completed in a fraction of a second before the metal hydroxide precipitate has form. For the reason so-called pump diffusion flash mixing (PDFM) have been proposed, and PDFM is one of reasonable methods to quickly disperse the hydrolyzing metal salts. In this study, therefore, we attempt to understand the difference of removal characteristics of natural organic matter (NOM) between pump diffusion flash mixing (PDFM) and conventional rapid mixing (CRM) for coagulation in a water treatment system, and to enhance the removal of NOM through the improved mixing process. DOC and turbidity removal by PDFM higher than those by CRM, while SUVA value of water treated by PDFM was high as compared with that by CRM. Hydrophilic NOM was more effectively removed by PDFM than CRM, since charge neutralization effect increased by quick dispersion of coagulant. The DBP formation potentials due to NOM was effectively reduced by the improved mixing (i.e., PDFM) for coagulation and could be controlled through decrease in concentration of precursor rather than reduction of activity with disinfectant.

The effects of algal-derived organic matters (AOMs) and chlorinated AOMs on the survival and behavior of zebrafish

  • Se-Hyun Oh;Jing Wang;Jung Rae Kim;Yunchul Cho
    • Membrane and Water Treatment
    • /
    • v.14 no.3
    • /
    • pp.141-146
    • /
    • 2023
  • Algal organic matters (AOMs) are challenging to remove using traditional water treatment methods. Additionally, they are recognized as disinfection by product (DBP) precursors during the chlorination process. These compounds have the potential to seriously harm aquatic creatures. Despite the fact that AOMs and DBPs formed from algae can harm aquatic species by impairing their cognitive function and causing behavioral problems, only a few studies on the effects of AOMs and associated DBPs have been conducted. To assess the impact of extracellular organic materials (EOMs) produced by three different hazardous algal species and the chlorinated EOMs on zebrafish, this study used fish acute embryo toxicity (FET) and cognitive function tests. With rising EOM concentrations, the embryo's survival rate and mental capacity both declined. Of the three algal species, the embryo exposed to Microcystis aeruginosa EOM exhibited the lowest survival rate. On the other hand, the embryo exposed to EOMs following chlorination demonstrated a drop in CT values in both the survival rate and cognitive ability. These findings imply that EOMs and EOMs treated with chlorine may have detrimental effects on aquatic life. Therefore, an effective EOM management is needed in aquatic environment.

Enhanced Photocatalytic Disinfection Efficiency through TiO2/WO3 Composite Synthesis and Heat Treatment Optimization

  • Sang-Hee Kim;Seo-Hee Kim;Jun Kang;Myeong-Hoon Lee;Yong-Sup Yun
    • Journal of Surface Science and Engineering
    • /
    • v.57 no.3
    • /
    • pp.179-191
    • /
    • 2024
  • This study focuses on improving the photocatalytic degradation efficiency by synthesizing a TiO2/WO3 composite. Given the environmental significance of photocatalysis and the limitations posed by TiO2's large bandgap and high electron recombination rate, we explored doping, surface modification, and synthesis strategies. The composite was created using a ball mill process and heat treatment, analyzed with field emission scanning electron microscope, high resolution X-ray diffraction, Raman microscope, and UV-Vis/NIR spectrometer to examine its morphology, composition and absorbance. We found that incorporating WO3 into the TiO2 lattice forms a Wx-Ti1-x-O2 solution, with optimal WO3 content reducing the band gap and enhancing sterilization efficiency by inhibiting the anatasese to rutile transition. This contributes to the field by offering a way to overcome TiO2's limitations and improve photocatalytic performance.

Improvement and Application of Assessment Criteria on Disease Control Level in Olive Flounder Aquaculture Farms (넙치 양식장의 질병관리등급 평가기준 개선 및 적용)

  • CHO, Miyoung;HA, Heon-Ju;MIN, Jin-Gi;KIM, Tae-Jin;JEE, Bo-Young;PARK, Shin-Hoo;HWANG, Seong-Don;KIM, Kwang-il;JANG, Yeounghwan;PARK, Myoung-Ae
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.27 no.6
    • /
    • pp.1646-1655
    • /
    • 2015
  • Korean government has issued the ratings standard for disease control of aquaculture farms according to the Aquatic Life Disease Control Act in 2008. There are five rating criteria within the enforcement regulations; period of disease free, performance of disinfection, environmental and hygienic management, keeping record of trade and sales, completion of education for disease control. There are no application has been applied on the basis of the rating criteria so far because detailed subcriteria and scoring indicators has not established for assessment process. In order to apply the ratings standard for disease control, we set up the subcriteria and new scoring for rating disease control level based on legal criteria in this study. This study was conducted on 90 targeted olive flounder farms in Jeju. The result of disease control level assessment on olive flounder aquaculture farms show the overall average of Jeju-do was 72.9 points and differed depending on the district; 74.7 in Jeju-si and 71.1 in Seogwipo-si, respectively. The Spearman correlation of each evaluation index show the disease control level score was correlated highly with the performance of disinfection(R=0.715, p<0.01), and environmental and hygienic management(R=0.661, p<0.01). The result of correlation analysis show that there is the highest correlation between the aquaculture farm status and the total mortality(R= -0.618, p<0.01). The reliability of the results are considered to be accurate in the Cronbach's alpha value of 0.727.

Infection control of dental implant hand drivers using ethanol solution (에탄올을 이용한 치과 임플란트 핸드 드라이버의 감염 관리에 대한 연구)

  • Yu, Song-Yi;Lee, Jin-Han
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.3
    • /
    • pp.158-167
    • /
    • 2020
  • Purpose: The purpose of this study was to study the effects of the utilization of ethanol solution in infection control of dental implant hand drivers, a common practice in dental prosthodontic clinics. Materials and Methods: Infection control methods were divided into two groups. One swabbed with 83% ethanol gauze and the other immersed in 83% ethanol solution for 30, 60, 90, 120, 150, 180 and 300 second intervals after inoculation of the dental implant hand drivers with Staphylococcus aureus. After measuring the number of colony forming units and analyzing the optical density, the effects of infection control in the experimental group were compared with the positive control group without infection control after inoculation with bacteria and the negative control group without inoculation with bacteria after sterilization. Results: The number of colony forming units and optical density analysis showed a statistically significant difference compared to the positive control. On the other hand, there was no statistically significant difference between the negative control and the group immersed in the 83% ethanol solution for more than 150 seconds. Conclusion: It is recommended to use the ethanol solution as a pre-cleaning process before sterilization, since the intermediate-level disinfection method using ethanol solution alone for the infection control of the dental implant hand driver cannot clinically secure the sterility.

Pig slurry treatment by the pilot scale hybrid multi-stage unit system (HMUS) followed by sequencing batch reactor (SBR) (HMUS와 SBR 반응조를 이용한 축분처리에 관한 연구)

  • Lee, Young-Shin;Han, Gee-Bong
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.21 no.2
    • /
    • pp.63-70
    • /
    • 2013
  • Experiments in a pilot-scale hybrid multi-stage unit system (HMUS) combination of ATAD and EGSB followed by SBR process for pig slurry treatment were conducted to demonstrate the feasibility of using autothermal thermophilic aerobic digestion (ATAD) and expended granular sludge bed (EGSB) followed by sequencing batch reactor (SBR) system. Contaminants in pig slurry with high organic matter, nitrogen (N) and phosphorus (P) content were completely removed in the combined process. The highest removal rate for CODcr among contaminants in the feed pig slurry was attained by about 43.3% in ATAD unit process. Also TS removal rate of 96.5% was attained and the highest in the next coagulation unit process. The highest removal rate of CODcr under operating parameter conditions of OLR(organic loading rate), 3-6Kg $COD/m^3{\cdot}day$ and line velocity, 1.5-4m/h was earned at 3days of HRT. The disinfection of pathogens was effective at 50,000mg/L of TS in ATAD unit process. Biogas production per organic removal was $2.3{\sim}8.5m^3/kgTS{\cdot}d$ (average $5.2m^3/kgTS{\cdot}d$) in EGSB unit process. The average removal rates of CODcr 71.7%, TS 64.1%, TN 45.9%, and TP 50.4% were earned in the intermittent aeration SBR unit process.

Influence of Manufacturing Conditions on the Reflectance and Life Time of the Gold Protected IR Mirror (금 증착 적외선 반사판의 반사율 및 수명에 미치는 제조공정 변수의 영향)

  • Choi, Yong-Sun;Lee, Young-Ki;Lee, You-Kee
    • Korean Journal of Materials Research
    • /
    • v.28 no.4
    • /
    • pp.201-207
    • /
    • 2018
  • Infrared(IR) heating has many advantages, such as energy efficiency, reduced heating time, cleanliness, equipment compactness, high drying rate and easy automation. These features of IR heating provide widely industrial applications, such as surface heat treatment in semiconductor fabrication, thermoforming of polymers, drying and disinfection of food products, heating to metal forging, and drying of wet materials. In this study, the characteristics of a protected gold mirror were examined by spectrophotometer and the lifetime of the coating layers were evaluated by a cross-cutting method and salt spray test. The effects of manufacturing conditions on the protected gold mirror were seen and remedies for these effects were noted in order to improve the properties of the protected gold mirror in the drying process. The reflectance and lifetime of the protected gold mirror was influenced by manufacturing conditions, such as surface roughness and forming conditions of the anti-oxide layer, the adhesion layer, the reflecting layer and the protection layer. The results of this study showed that the protected gold mirror manufactured using a buffing method for pre-treatment resulted in the most effective reflectance. In addition, $Al_2O_3$ coating on an Al substrate as an anti-oxide layer was more effective than the anodizing process in the test of reflectance. Furthermore, the protected gold mirror manufactured by layers forming of various materials resulted in the most effective reflectance and lifetime when coated with $Al_2O_3$ as the anti-oxide layer, coated Cr as the adhesion layer, and coated $MgF_2$ as the protection layer.

Intelligent Controller for Constant Control of Residual Chlorine in Water Treatment Process (정수장 잔류염소 일정제어를 위한 지능형 제어기 개발)

  • Lee, Ho-Hyun;Jang, Sang-Bok;Hong, Sung-Taek;Chun, Myung-Geun
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.24 no.2
    • /
    • pp.147-154
    • /
    • 2014
  • In this study, chlorine modeling technique based on fuzzy system is proposed to reduce the carcinogenic substance and decide the optimal chlorine injection rate, which is affected by chlorine evaporation rate in sedimentation basin according to detention time, weather and water quality. The additional chlorine meter is installed in the inlet part of sedimentation to reduce the feedback time and implement cascade control, which leads to maintaining the residual chlorine concentration decided by fuzzy rule. It helps to take a preemptive action about long time delay, the characteristics of the disinfection process, and reduce the variation of residual chlorine rate by 7.3 times and the chlorine consumption by 40,000 dollars. It made a significant contribution to supply hygienically safe drinking water.