• Title/Summary/Keyword: Disinfectant efficiency

Search Result 28, Processing Time 0.026 seconds

Analysis of Removal Efficiency of Pesticide Residue on Dishwashing Detergent and Alcoholic Disinfectant by Gas Chromatography (가스 크로마토그래피에 의한 주방용 합성세제와 알콜소독제의 잔류농약 제거효과 분석)

  • Lee, Jae-Duk;Cho, Yun-Jin;Lee, Man-Ho;Jeung, Woo-Won
    • Applied Chemistry for Engineering
    • /
    • v.9 no.7
    • /
    • pp.985-989
    • /
    • 1998
  • In this study, removal efficiencies of pesticides on apples and peppers with water, dishwashing detergent, and alcoholic disinfectant were investigated by Gas Chromatography. Different conditions of pretreatment for increase of pesticide recovery were investigated for optimum condition. In our experiment, the supelco-STB-608 column and electron capture detector(ECD) were used to analyze pesticides residue. Removal efficiency of pesticide was in the order of alcoholic disinfectant>dishwashing detergent>water.

  • PDF

Effects of ozone, ultraviolet and an organic acid-based disinfectant against porcine reproductive and respiratory syndrome virus

  • Yoon, Yong-Dae;Kim, Won-Il
    • Korean Journal of Veterinary Service
    • /
    • v.36 no.3
    • /
    • pp.157-162
    • /
    • 2013
  • A good level of biosecurity practice is important for efficient porcine reproductive and respiratory syndrome (PRRS) control. In the current study, disinfecting ability of ozone against PRRS virus (PRRSV) was evaluated in comparison with ultraviolet (UV) and an organic acid-based disinfectant to assess the possible use of ozone for disinfecting farm vehicles, equipments, and materials to reduce the risk of new virus introduction. For in vitro evaluation, the levels of infectious virus and viral RNA were determined on the swabs collected from the floor surface of each room treated with either ozone, UV or the disinfectant up to 30 min after contamination with 100 mL of VR2332 ($10^5\;TCID_{50}/mL$). For in vivo evaluation, 3, 4-week old, PRRS-free pigs were housed into those rooms right after the last swab collection. Then the pigs in each room were injected intramuscularly with the corresponding swab samples collected at the last time point and pooled per each room. Although ozone, UV, and the disinfectant significantly reduced the levels of PRRSV RNA contamination, ozone was most effective in removing the viral RNA. In addition, the virus collected after at least 10 min exposure to ozone failed to replicate in pigs while the virus collected after treatment with UV and the disinfectant for 30 min still replicated in pigs. Based on the results, it was concluded that ozone is more effective in inactivating PRRSV as compared with UV and the organic acid-based disinfectant.

Comparative Study on Disinfection Efficiency of Chlorine and Chloramine in the Distribution Systems (배·급수계통에서 유리염소와 클로라민의 소독효과에 관한 비교연구)

  • Choi, Yong-Il;Nam, Sang-Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.13 no.2
    • /
    • pp.82-88
    • /
    • 1999
  • This study was to evaluate disinfection efficiency of chlorine and chloramine as secondary disinfectants in the distribution systems. Indicator organism, HPC in the suspended and attached were measured for copper, galvanized steel, PVC, and carbon steel pipes. For suspended microorganism, the PVC pipe was markedly dense among the assessed pipe materials. The attached microorganism was markedly equivalent roughness of pipe materials. In copper and galvanized pipes, chloramine was more effective that free chlorine to disinfect suspended microorganism in the contact time of 2 hours. The contact time for the 99% inactivation of suspended microorganism by chloramine was longer than that of free chlorine. Regardless of pipe materials, chloramine was effective on both disinfection efficiency and 99% inactivation time for attached microorganism. In conclusion, chloramine which is good disinfectant for long contact time was recommended as secondary disinfectant in distribution system.

  • PDF

Tracer Experiment and Computational Fluid Dynamics Analysis for the Drainage Efficiency of a Reservoir (배수지의 배수효율분석을 위한 추적자실험 및 전산유체해석)

  • Cho, Jung-Yeon;Go, Sun-Ho;Kwac, Lee-Ku
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.16 no.2
    • /
    • pp.22-27
    • /
    • 2017
  • During the water treatment process for household water supply, a reservoir is the last place the water is stored before being supplied to users, and the duration of the water's stay is an important factor that affects its safety. This may cause the concentration of the residual chlorine disinfectant to increase and thus lower the water's quality. The concentration and discharge efficiency of residual chlorine must be verified and managed, because these are key factors that affect the reservoir's performance. Because the actual verification test for analyzing the efficiency of a reservoir and the disinfectant's dilution capacity is difficult, simulations are generally conducted using the computational fluid analysis method. However, the simulation results require validation with experiments. The error and drainage efficiency were analyzed in this study by comparing and analyzing the actual tracer test and simulation so that the actual test for a hexagonal drainage can be replaced by the computational fluid analysis method. Based on the results of the efficiency analysis, the hexagonal reservoir was found to be appropriate, and the simulation's reliability was verified with a tracer test.

Disinfection by Ozone Microbubbles Can Cause Morphological Change of Fusarium oxysporum f. sp. melonis Spores

  • Tamaki, Masahiko;Kobayashi, Fumiyuki;Ikeura, Hiromi;Sato, Michio
    • The Plant Pathology Journal
    • /
    • v.34 no.4
    • /
    • pp.335-340
    • /
    • 2018
  • To investigate the difference in the disinfectant efficiency of ozone microbubbles ($O_3MB$) and ozone millibubbles ($O_3MMB$), the morphological change of the treated Fusarium oxysporum f. sp. melonis spores was observed with scanning and transmission electron microscopies (SEM and TEM). The disinfectant efficiency of $O_3MB$ on F. oxysporum f. sp. melonis spores was greater than that of $O_3MMB$. On observation with SEM, it was revealed that morphological change of F. oxysporum f. sp. melonis spores was caused by $O_3MB$ and $O_3MMB$, and damage to the spore surfaces by $O_3MB$ occurred sooner than that by $O_3MMB$. On observation with TEM, it was furthermore confirmed that F. oxysporum f. sp. melonis spores treated with $O_3MB$ induced wavy deformation of cell membrane and the intracellular change different from that with $O_3MMB$. Therefore, the greater disinfection efficiency of $O_3MB$ was suggested to be caused due to the function of the MB in addition to the oxidative power of $O_3$.

Comparison of Bacterial Removal Effectiveness by Different Hand Washing Methods (손세정 방법에 따른 세균 제거 효과 비교에 대한 융복합 연구)

  • Chong, Moo-Sang;Lee, Jang-Jin;Kim, Jiro
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.9
    • /
    • pp.69-74
    • /
    • 2019
  • The purpose of this study is to compare the efficiency of bacteria removal of three different types of hand washing methods. This study performed a convenient sampling of 30 volunteers in cross-over design. The study divided the 30 volunteers into three random groups. The three groups were asked to use antiseptic soap, alcohol-based hand disinfectant, and disposable wet wipes respectively. The result of the study showed that mean log reduction values after each had washing method were $-0.45({\pm}0.69)$ with antiseptic soap and water, $-1.19({\pm}0.52)$ with alcohol-based hand disinfectant and $-0.75({\pm}0.58)$ with disposable wet wipes. The difference was statistically significant when using alcohol-based hand disinfectant compared to the other two methods (p=0.000). According to this study, alcohol-based hand disinfectant was the most effective product based on bacteria removal for hand washing. Advantages of using alcohol-based hand disinfectant are that it is cost-effective and easy to buy, also eco-friendly. Therefore, to prevent infectious disease, providing alcohol-based hand disinfectant to every corner of the community will be very helpful.

Evaluation of Efficiency of Livestock Vehicle Disinfection Systems Using Water-Sensitive Paper (감수 시험지를 활용한 축산시설 차량소독시스템의 소독액 분사 효율성 평가)

  • Park, Jinseon;Hong, Se-Woon;Lee, In-bok
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.62 no.4
    • /
    • pp.87-97
    • /
    • 2020
  • The livestock infections had been happened seasonally, but they have gradually changed to be irrelevant to seasons and have an aspect to rapidly spread after outbreak. Especially in Korea, proactive disinfection measures are very important because the livestock farms are located densely so high as to accelerate the spread of disease between farms. livestock disease outbreaks like HPAI and FMD occurred with high probability due to vehicles visiting the farms, this study is to evaluate the efficiency of livestock vehicle disinfection systems by investigating the disinfectant coverage according to the type of vehicle disinfection system and the type of vehicle quantitatively. In field experiments, water-sensitive papers (WSPs) were attached to 21 locations on the surface of four vehicles (sedan, SUV, truck, and feed transport), respectively, and exposed to disinfectants while the vehicle was sprayed in two vehicle disinfection systems (tunnel type and simplified type). The WSPs were scanned and image-processed to calculate the disinfectant coverage. The results showed that the tunnel-type vehicle disinfection system had a better disinfection performance with an average coverage of 90.27% for all vehicles compared to 32.62% of the simplified type system. The problem of the simplified system was a wide coefficient of variation (1.05-1.31) of the disinfectant coverage between 21 locations indicating a need for further improvement of nozzle location and arrangement.

Reduction Effect of Air Cleaner on Particulate Matters and Biological Agents in a Swine Facility (공기정화기 적용에 따른 돈사 작업장내 입자상 물질 및 생물학상 물질 저감 효과에 관한 연구)

  • Kim, Ki Youn
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.27 no.1
    • /
    • pp.70-76
    • /
    • 2017
  • Objectives: This on-site study was performed to evaluate the reduction efficiency of an air cleaner on particulate matters and biological agents in a swine facility. Materials and Methods: Particulate matter was measured using a real-time monitoring recorder and biological agents were sampled with a one-stage impactor and then analyzed based on the microbial culture method. An experimental process for the reduction effect on airborne pollutants through air cleaner operation consisted of three conditions: no treatment, wet scrapper by water spray and wet scrapper by disinfectant spray. Results: Geometric mean levels of particulate matter(TSP, $PM_{10}$, $PM_{2.5}$ and $PM_1$) were presented at $1,608{\mu}g/m^3$, $1,373.8{\mu}g/m^3$, $401.8{\mu}g/m^3$ and $144.5{\mu}g/m^3$ for no treatment; $1,503{\mu}g/m^3$, $1,017{\mu}g/m^3$, $159.4{\mu}g/m^3$ and $69.8{\mu}g/m^3$ for wet scrapper by water spray; and $1,222.17{\mu}g/m^3$, $477.17{\mu}g/m^3$, $33.2{\mu}g/m^3$ and $11.1{\mu}g/m^3$ for wet scrapper by disinfectant spray, respectively. In the case of biological agents, the geometric averaged concentrations of total airborne bacteria and fungi were as follows: $45,371cfu/m^3$ and $13,474cfu/m^3$ for no treatment, $43,286cfu/m^3$ and $8,610cfu/m^3$ for wet scrapper by water spray, and $2,440cfu/m^3$ and 1,867 cfu/ for wet scrapper by disinfectant spray, respectively. Regardless of particulate matter and biological agent, the highest concentrations were found for no treatment, while the lowest concentrations were found with wet scrapper by disinfectant spray. Conclusions: Based on the results obtained from this on-site evaluation, there was a significant reduction effect on particulate matter and biological agents through the application of an air cleaner in this study.

Disinfection Efficiency of Silver Disinfectants for Biofilm (은 화합물을 이용한 생물막 제어)

  • Kim, Jae-Eun;Kim, Jee-Yeon;Yoon, Je-Yong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.1
    • /
    • pp.81-87
    • /
    • 2006
  • The industrial systems contain many sites and components susceptible to biofilms formation. Biofilms play an important role in microbial growth and industrial fouling. Thus, the control of the biofilms in industrial systems has been emphasized, however, the efficient controlling method was not provided yet. Since silver compounds have no residual and corrosion problem, the interest for silver compounds as a biofilm control disinfectant has been increased. In this study, we attempted to examine the disinfection ability of silver compounds. The disinfection efficiency of two silver compounds(silver ion and silver oxide) were evaluated for biofilms in comparison with suspended cells using well known indicator microorganisms(E. coli, P. aeruginosa) and compared with that of chlorine. Silver compounds were found to be effective in inactivating E. coli and P. aeruginosa biofilms. The reason for superiority of silver compounds as biofilm disinfectant was suggested by that silver can penetrate into the inner biofilm matrix faster than chlorine without consumption. This study reports that the disinfectant which is highly effective in inactivating the suspended cells in water becomes the less effective for controlling biofilm because of its high reactivity. This results imply that the effective strategy for biofilm control can be achieved by considering thoroughly the chemical nature of disinfects and biofilm structure and the reactivity between them.

A Study on the Static mixer and Microbubble of the Sidestream Ozone Contact System to Improve Water Treatment Efficiency (사이드스트림 오존 접촉조에서 수처리 효율 향상을 위한 정적혼합기와 미세기포에 관한 연구)

  • Kim, Jin-Hoon;Park, Jong-Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.6
    • /
    • pp.763-768
    • /
    • 2009
  • Ozone is a strong oxidant and a powerful disinfectant. In general, it has been used in drinking water treatment during last 100years. Ozone dissolution features are defined by the two categories of ozone contactors, bubble-diffuser and sidestream ozone contactor. Currently, sidestream-injection systems are gaining in popularity but operating cost might be slightly higher. Sidestream ozone system dissolve ozone into a sidestream flow via an injection setup or in the main process flow stream in some sidestream arrangements. The sidestream flow is subsequently mixed with the main process flow stream, which is directed to a reation tank or pipeline for oxidation and disinfection reactions. The purpose of this study is to suggest optimal operating pressure, to figure out the static-mixer effect and to understand the microbubble characteristics of ozone to improve dissolution efficiency.