• Title/Summary/Keyword: Discriminative measurement

Search Result 19, Processing Time 0.023 seconds

Study on sampling methods for mold from indoor air in domestic environment (국내 환경에서 실내 부유진균 포집 방법 연구)

  • Ahn, Geum Ran;Kim, Bo Young;Kim, Ji Eun;Son, Bu Sun;Park, Moo-Kyun;Kim, Sung-Yeon;Kwon, Myung-Hee;Kim, Seong Hwan
    • Journal of odor and indoor environment
    • /
    • v.16 no.1
    • /
    • pp.47-53
    • /
    • 2017
  • Mold is one of the important bio-aerosols affecting human health in the indoor environment. To manage mold contamination, it is necessary to use an appropriate method for its detection and enumeration. Recently, the impaction method of ISO 16000-18 has been established as one of methods to detect and enumerate molds in air. To investigate the general use of the impaction method for mold detection in domestic indoor environments, the suitability of the method was assessed using different antibiotics, media and air samplers. All of the three antibiotics tested - ampicillin, chloramphenicol and streptomycin - showed inhibitory effects on bacterial colony formation on MEA and DG-18 media, without inhibiting mold growth. Of these three antibiotics, ampicillin was the most effective. There was no statistical difference between MEA and DG-18 media in the measurement of mold concentration. The formation of discriminative colony morphology was more apparent in DG-18 media. No significant difference in the measurement of mold concentration was found between Andersen samplers and MAS-100NT samplers, which are two major samplers introduced in Korea.

Development of weight prediction 2D image technology using the surface shape characteristics of strawberry cultivars

  • Yoo, Hyeonchae;Lim, Jongguk;Kim, Giyoung;Kim, Moon Sung;Kang, Jungsook;Seo, Youngwook;Lee, Ah-yeong;Cho, Byoung-Kwan;Hong, Soon-Jung;Mo, Changyeun
    • Korean Journal of Agricultural Science
    • /
    • v.47 no.4
    • /
    • pp.753-767
    • /
    • 2020
  • The commercial value of strawberries is affected by various factors such as their shape, size and color. Among them, size determined by weight is one of the main factors determining the quality grade of strawberries. In this study, image technology was developed to predict the weight of strawberries using the shape characteristics of strawberry cultivars. For realtime weight measurements of strawberries in transport, an image measurement system was developed for weight prediction with a charge coupled device (CCD) color camera and a conveyor belt. A strawberry weight prediction algorithm was developed for three cultivars, Maehyang, Sulhyang, and Ssanta, using the number of pixels in the pulp portion that measured the strawberry weight. The discrimination accuracy (R2) of the weight prediction models of the Maeyang, Sulhyang and Santa cultivars was 0.9531, 0.951 and 0.9432, respectively. The discriminative accuracy (R2) and measurement error (RMSE) of the integrated weight prediction model of the three cultivars were 0.958 and 1.454 g, respectively. These results show that the 2D imaging technology considering the shape characteristics of strawberries has the potential to predict the weight of strawberries.

Korean Translation and Validation of the Paediatric Allergic Disease Quality of Life Questionnaire (PADQLQ) (Paediatric Allergic Disease Quality of Life Questionnaire (PADQLQ)의 한국어판 개발과 신뢰도, 타당도에 대한 연구)

  • Park, Seul Ki;Kim, Sehyun;Lee, Sun Haeng;Chang, Gyu Tae
    • The Journal of Pediatrics of Korean Medicine
    • /
    • v.27 no.3
    • /
    • pp.41-52
    • /
    • 2013
  • Objectives In pediatrics of Korean Medicine, it is crucial to evaluate the overall symptoms of children, especially in the children who have serious troubles in their life. In the era when diagnosis in Korean Medicine is quite suitable to evaluate multiple allergic diseases, and when growing numbers are in needs, development of an objective measurement scale for diagnosis of allergic disease in Korean Medicine became essential. Therefore, in the study, pediatric Allergic Disease Quality of Life Questionnaire (PADQLQ) was translated into Korean version with validations on some aspects. Methods In this study, we translated and validated the PADQLQ and established psychometric evidence on its utility in Korean children with similar problems. 71 children, age of 6 ~ 18 with allergic disease has participated. Results The internal consistency reliability of the PADQLQ by Cronbach's ${\alpha}$ was 0.94. In three domains (Practical, Physical, Emotional), the Cronbach's ${\alpha}$ was 0.77, 0.90 and 0.69. The Spearman's rank correlation coefficient between PADQLQ total score and VAS was 0.75 (p<0.001). And, Structural validity was evaluated by the ANOVA test. QoL differences of the four groups in the three domains (practical, physical, emotional) were significant. The item discriminative indices were ranged from 0.1651 to 0.8188. Conclusions Korean version PADQLQ is highly reliable and valid for children with allergic diseases. This is significant to assess the relative seriousness of the allergic diseases and to evaluate the efficacy of different treatments in Korean Medicine.

Three-dimensional kinematic motion analysis of door handling task in people with mild and moderate stroke

  • Lee, Jung Ah;Kim, Eun Joo;Hwang, Pil Woo;Park, Han Ram;Bae, Jae Hyuk;Kim, Jae Nam
    • Physical Therapy Rehabilitation Science
    • /
    • v.5 no.3
    • /
    • pp.143-148
    • /
    • 2016
  • Objective: This study aimed to quantify one of the useful upper extremity movements to evaluate motor control abilities between the groups of people with mild and moderate arm impairments performing a door handling task. Design: Cross-sectional study. Methods: Twenty-one healthy participants and twenty-one persons with chronic stroke (9 mild stroke and 12 moderate stroke) were recruited for this study. Stroke participants were divided into 2 groups based on Fugle-Meyer Assessment scores of 58-65 (mild arm) and 38-57 (moderate arm). All they performed door handling task including the pronation and supination phases 3 times. We measured some movement factors which were reaction time, movement time, hand of peak velocity, hand of movement units to perform door handling task using the three-dimensional motion analysis. Results: The majority of kinematic variables showed significant differences among study groups (p<0.05). The reaction time, total and phase of movement time, hand of peak velocity, the number of movement units discriminated between healthy participants and persons with moderate upper limb stroke (p<0.05). In addition, reaction time, total and phase of movement time, the number of movement units discriminated between those with moderate and mild upper limbs of stroke patients (p<0.05). Conclusions: Three-dimensional kinematic motion analysis in this study was a useful tool for assessing the upper extremity function in different subgroups of people with stroke during the door handling task. These kinematic variables may help clinicians understand the arm movements in door handling task and consist of discriminative therapeutic interventions for stroke patients on upper extremity rehabilitation.

Preoperative Korean Shoulder Scoring System Correlates with Preoperative Factors of Rotator Cuff Tears

  • Kim, Eun-Yeol;Park, Byung-Yoon;Kim, In-Bo
    • Clinics in Shoulder and Elbow
    • /
    • v.21 no.1
    • /
    • pp.30-36
    • /
    • 2018
  • Background: The Korean Shoulder Scoring System (KSS) is a reliable and valid procedure for discriminative assessment of the clinical status of patients with rotator cuff tears. This study evaluates the correlation between the preoperative KSS and factors in patients with rotator cuff tears. Methods: From November 2009 to June 2016, 970 patients who underwent arthroscopic rotator cuff repair were retrospectively evaluated. A total of 490 patients met the study criteria. Preoperative factors included age, sex, symptom duration, mediolateral (ML) and anteroposterior (AP) tear size, acromiohumeral distance (AHD), tangent sign, tendon involvement (type I, supraspinatus; type II, supraspinatus and subscapularis; type III, supraspinatus and infraspinatus; type IV, all 3 tendons), fatty infiltration of rotator cuff muscles (group I, Goutallier stages 0 and 1; group II, Goutallier stages 2, 3, and 4), and KSS. Results: Old age, ML tear size, and AP tear size negatively correlated with the preoperative KSS (p<0.001). AHD showed a positive correlation with the preoperative KSS (p<0.001). A significantly inferior preoperative KSS was found in females and type III tendon involvement (p<0.001). For supraspinatus and infraspinatus, the preoperative KSS of group II fatty infiltration showed a significantly lower score than group I fatty infiltration (p<0.05). Conclusions: A relatively lower preoperative KSS was associated with old age, large tear size, narrow AHD, female, type III tendon involvement, and group II fatty infiltration of the supraspinatus and infraspinatus. Our study indicates that preoperative KSS can be a good measurement for the preoperative status of patients with rotator cuff tears.

Audio Fingerprint Extraction Method Using Multi-Level Quantization Scheme (다중 레벨 양자화 기법을 적용한 오디오 핑거프린트 추출 방법)

  • Song Won-Sik;Park Man-Soo;Kim Hoi-Rin
    • The Journal of the Acoustical Society of Korea
    • /
    • v.25 no.4
    • /
    • pp.151-158
    • /
    • 2006
  • In this paper, we proposed a new audio fingerprint extraction method, based on Philips' music retrieval algorithm, which uses the energy difference of neighboring filter-bank and probabilistic characteristics of music. Since Philips method uses too many filter-banks in limited frequency band, it may cause audio fingerprints to be highly sensitive to additive noises and to have too high correlation between neighboring bands. The proposed method improves robustness to noises by reducing the number of filter-banks while it maintains the discriminative power by representing the energy difference of bands with 2 bits where the quantization levels are determined by probabilistic characteristics. The correlation which exists among 4 different levels in 2 bits is not only utilized in similarity measurement. but also in efficient reduction of searching area. Experiments show that the proposed method is not only more robust to various environmental noises (street, department, car, office, and restaurant), but also takes less time for database search than Philips in the case where music is highly degraded.

The application of Fourier transform near infrared (FT-NIR) spectroscopy in the wine industry of South Africa

  • Van Zyl, Anina;Manley, Marena;Wolf, Erhard E.H.
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1257-1257
    • /
    • 2001
  • Fourier transform near infrared (FT-NIR) spectroscopy was used as a rapid method to measure the $^{o}Brix$ content and to discriminate between different must samples in terms of their fee amino nitrogen (FAN) values. FT-NIR spectroscopy was also used as a rapid method to discriminate between Chardonnay wine samples in terms of the status of the male-lactic fermentation (MLF). This was done by monitoring the conversion of malic to lactic acid and thereby determining whether MLF has started, is underway or has been completed followed by classification of the samples. Furthermore, FT-NIR spectroscopy was applied as a rapid method to discriminate between table wine samples in terms of the ethyl carbamate (EC) content. EC in wine can pose a health threat and need to be monitored by determining the EC content in relation to the regulatory limits set by the authorities. For each of the above mentioned parameters, $QUANT+^{TM}$ methods were built and calibrations derived and it was found that a very strong correlation existed in the sample set for the FT-NIR spectroscopic predictions of $^{o}Brix$ (r = 0.99, SECV = 0.306), but the correlations for the FAN (r = 0.61, SECV = 272.1), malic acid (r = 0.58, SECV = 1.06), lactic acid (r = 0.51, SECV = 1.14) and EC predictions (r = 0.47, SECV = 3.67) were not as good. Soft Independent Modeling by Class Analogy (SIMCA) diagnostics and validation was applied as a sophisticated discrimination method. The must samples could be classified in terms of their FAN values when SIMCA was applied, obtaining results with recognition rates exceeding 80%. When SIMCA diagnostics and validation were applied to determine the progress of conversion of malic to lactic acid and the EC content, again results with recognition rates exceeding 80% were obtained. The evaluation of the applicability of FT-NIR spectroscopy measurement of FAN, $^{o}Brix$ values, malic acid, lactic acid and EC content in must and wine shows considerable promise. FT-NIR spectroscopy has the potential to reduce the analytical times considerably in a range of measurements commonly used during the wine making process. Where conventional FT-NIR calibrations are not effective, SIMCA methods can be used as a discriminative method for rapid classification of samples. SIMCA can replace expensive, time-consuming, quantitative analytical methods, if not completely, at least to some extent, because in many processes it is only needed to know whether a specific cut off point has been reach or not or whether a sample belongs to a certain class or not.

  • PDF

Validity of Long Form Assessment in Interactive Metronome® as a Measure of Children's Praxis (아동의 운동기능평가에 대한 Interactive Metronome® LFA의 타당도 연구)

  • Kim, Kyeong-Mi;Heo, Seo-Yoon;Kim, Mi-Su;Lee, Soo-Min
    • The Journal of Korean Academy of Sensory Integration
    • /
    • v.13 no.1
    • /
    • pp.13-22
    • /
    • 2015
  • Objective : The aim of this study is to verify validity of Long Form Assessment, which is an Interactive Metronome $measure^{(R)}$(LFA-IM), as a measurement of praxis of children. Methods : The study was implemented from March 2015 to July 2015. Twenty-five children with Attention Deficit Hyperactivity Disorder (ADHD) and those without ADHD (age of 6~11) were selected from a local university hospital and community in Gyeoung-Nam province and Busan for this study. In order to examine discriminative validity of LFA-IM, Bruininks-Oseretsky Test of Motor Proficiency, second edition (BOT-2) was used to compare the difference of results with LFA-IM for both children with- and without ADHD. For concurrent validity, correlation between LFA-IM and BOT-2 was investigated using spearman correlation coefficients. Results : For the comparison between children with ADHD and children without ADHD, there were significant differences in the total scores of LFA-IM (p<.05). Regarding the concurrent validity, there was a strong negative correlation between the total scores of LFA-IM and BOT-2 (p<.05). In addition, there was high correlation between LFA-IM and BOT-2 for the area of hand control (rs=-.532), and high negative correlation for the area of fine-motor accuracy (rs=-.447), hand dexterity (rs=-.532), and balance control (rs=-.623) (p<.05). Conclusion : This study identified validities of LFA-IM as an assessment of praxis of children. The results showed that it is appropriate to evaluate praxis of children with the total score of LFA-IM and, thus, it is believed that LFA-IM has a potential clinical utility. However, there should be more researches with large number of subjects.

A comparison between impulse oscillometry system and spirometry for spirometry for detecting airway obstruction in children (소아의 기도 폐쇄 평가에서 impulse oscillometry system과 폐활량 측정법의 비교)

  • Hur, Hae Young;Kwak, Ji Hee;Kim, Hyoung Yun;Jung, Da Wun;Shin, Yoon Ho;Han, Man Yong
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.8
    • /
    • pp.842-847
    • /
    • 2008
  • Purpose : Measurement of forced expiratory volume in 1 second ($FEV_1$) is usually difficult to obtain in children under six years of age because it requires active cooperation. This study evaluates the sensitivity of impulse oscillometry system (IOS) parameters for detecting airway obstruction in comparison with $FEV_1$. Methods : We studied 174 children who performed the lung function and methacholine challenge tests to diagnose asthma by IOS and spirometry. Children were divided into two subgroups according to their $PC_{20}$, which is a parameter for bronchial sensitivity. We compared IOS parameters with $FEV_1$ at the baseline, post-methacholine challenge, and evaluated their correlation. Results : At the baseline, reactance at 5 Hz (X5) and resistance at 5 Hz (R5) significantly differed between the $PC_{20}$ positive ($PC_{20}{\leq}16mg/mL$) group and $PC_{20}$ negative ($PC_{20}$ >16 mg/mL) group; however, $FEV_1$, $FEV_1$ % predicted, $FEV_1_-Zs$ (Z score) did not differ. $FEV_1$ is correlated with X5 (r=0.45, P<0.01) and R5 (r=-0.69, P<0.01). $FEV_1_-Zs$ is also correlated with X5_Zs (r=-0.26, P<0.01) and R5_Zs (r=-0.31, P<0.01). After the methacholine challenge test, dose-response slopes in $FEV_1$ and X5 significantly differed between the two subgroups (P<0.05). Conclusion : IOS parameters were more discriminative than $FEV_1$ for detecting decreased baseline lung function between two subgroups and have a good correlation with $FEV_1$.