• 제목/요약/키워드: Discrete noise

검색결과 508건 처리시간 0.028초

Sparsification of Digital Images Using Discrete Rajan Transform

  • Mallikarjuna, Kethepalli;Prasad, Kodati Satya;Subramanyam, M.V.
    • Journal of Information Processing Systems
    • /
    • 제12권4호
    • /
    • pp.754-764
    • /
    • 2016
  • The exhaustive list of sparsification methods for a digital image suffers from achieving an adequate number of zero and near-zero coefficients. The method proposed in this paper, which is known as the Discrete Rajan Transform Sparsification, overcomes this inadequacy. An attempt has been made to compare the simulation results for benchmark images by various popular, existing techniques and analyzing from different aspects. With the help of Discrete Rajan Transform algorithm, both lossless and lossy sparse representations are obtained. We divided an image into $8{\times}8-sized$ blocks and applied the Discrete Rajan Transform algorithm to it to get a more sparsified spectrum. The image was reconstructed from the transformed output of the Discrete Rajan Transform algorithm with an acceptable peak signal-to-noise ratio. The performance of the Discrete Rajan Transform in providing sparsity was compared with the results provided by the Discrete Fourier Transform, Discrete Cosine Transform, and the Discrete Wavelet Transform by means of the Degree of Sparsity. The simulation results proved that the Discrete Rajan Transform provides better sparsification when compared to other methods.

철로를 따라 전파되는 파동 해석을 위한 고주파수 대역 철로 모델링 (Modelling of Railway Tracks for Wave Propagation along Railway Tracks at High Frequencies)

  • 유정수
    • 한국소음진동공학회논문집
    • /
    • 제21권3호
    • /
    • pp.248-257
    • /
    • 2011
  • It was reported recently that railpads can be included as a continuous elastic support of the rail and the model was justified from experiments. In general, however, railpads are installed discretely on sleepers with a regular span. The effect of the discrete railpad was not clearly examined so far in such a high frequency range. In this paper, the effect of the railpads in track modelling for high frequencies is investigated by means of the finite element analysis. To do that, the railpads are regarded as 'a continuous elastic support' and 'a discrete elastic support' in this paper. The dispersion relations and decaying features are predicted and compared between the two models up to 80 kHz.

Robustness of 2nd-order Iterative Learning Control for a Class of Discrete-Time Dynamic Systems

  • 김용태
    • 한국지능시스템학회논문지
    • /
    • 제14권3호
    • /
    • pp.363-368
    • /
    • 2004
  • In this paper, the robustness property of 2nd-order iterative learning control(ILC) method for a class of linear and nonlinear discrete-time dynamic systems is studied. 2nd-order ILC method has the PD-type learning algorithm based on both time-domain performance and iteration-domain performance. It is proved that the 2nd-order ILC method has robustness in the presence of state disturbances, measurement noise and initial state error. In the absence of state disturbances, measurement noise and initialization error, the convergence of the 2nd-order ILC algorithm is guaranteed. A numerical example is given to show the robustness and convergence property according to the learning parameters.

대량생산용 음향방출제품의 돌출음 평가장비 개발 (Development of the evaluation equipment for the prominent discrete tone radiated by acoustic emission products in mass production)

  • 이용관;김선
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2012년도 춘계학술대회 논문집
    • /
    • pp.76-81
    • /
    • 2012
  • In-process evaluation equipment for the prominent discrete tone (PDT) emitted by small motors or actuators such as HDD(Hard Disk Driver), ODD(Optical Disk Driver) or linear motors has been developed and estimated on the basis of Prominence Ratio (PR) method in ECMA 74. Correlation of the evaluation equipment was performed in comparison with the method by ECMA 74 in anechoic chamber. Coherent function between two systems was applied in order to compensate traceability of ECMA 74 in anechoic chamber. Usability of the developed system with estimated Gage R&R shall be approved with real samples in the mass production line.

  • PDF

이산 카오스 함수와 Permutation Algorithm을 결합한 고신뢰도 광영상 암호시스템 (A high reliable optical image encryption system which combined discrete chaos function with permutation algorithm)

  • 박종호
    • 정보보호학회논문지
    • /
    • 제9권4호
    • /
    • pp.37-48
    • /
    • 1999
  • 현대암호방식은 종래의 선형 대수와 수리이론을 적용한 암호통신을 벗어난 유사 잡음성을 띠는 카오스 신호를 이용한 암호통신을 적용해 오고 있다,[1-2] 본 논문은 1차 permutation 알고 리즘을 이용 하여 변환된 정보를 2차 이산 카오스 변환 함수를 이용해 암호화하는 광영상 암호시스템을 제안하여UT 다. 제안된 시스템은 키수열 발생기의 출력을 통해 영상정보를 permutation 하는 알고리즘 을 설계하였고 이에 대한 검정을 수행하였다. 또한 본 논문에서는 permutation 알고리즘을 통해 제한적인 카오스 함수 의 적용시 발생하는 문제점을 해결하고 비도를 증가시킴으로써 광영상 암호시스템에 적용 시 그 타당성 을 검정하였다. Current encryption methods have been applied to secure communication using discrete chaotic system whose output is a noise-like signal which differs from the conventional encryption methods that employ algebra and number theory[1-2] We propose an optical encryption method that transforms the primary pattern into the image pattern of discrete chaotic function first a primary pattern is encoded using permutation algorithm, In the proposed system we suggest the permutation algorithm using the output of key steam generator and its security level is analyzed. In this paper we worked out problem of the application about few discrete chaos function through a permutation algorithm and enhanced the security level. Experimental results with image signal demonstrate the proper of the implemented optical encryption system.

연료전지 자동차의 공기 공급계용 흡기 소음기의 최적 설계 (Design Optimization of Intake Muffler for Fuel Cell Electric Vehicle APU)

  • 김의열;이영준;이상권
    • 한국자동차공학회논문집
    • /
    • 제20권5호
    • /
    • pp.44-52
    • /
    • 2012
  • Fuel cell electric vehicles have some noise problems due to its air processing unit which is required to feed the ambient air into the fuel cell stack. Discrete-frequency noises are radiated from a centrifugal blower due to rotor-stator interaction. Their fundamental frequency is the blade passing frequency, which is determined by the number of rotor blades and their rotating speed. To reduce such noises, multi-chamber perforated muffler has been designed. In this paper, in order to improve the transmission loss of a perforated muffler, the relationship between the impedance model of a perforated hole and its noise reduction performance is studied, and the applicability of a short-length perforated muffler to air processing unit of fuel cell system is described using acoustic simulation results and experimental data. The acoustic velocity vector across the neck of a perforated hole is very important design factor to optimize the transmission of an intake muffler. The suggested short-length perforated muffler is effective on discrete-frequency noises while keeping the volume of intake muffler minimized.

ECG Denoising by Modeling Wavelet Sub-Band Coefficients using Kernel Density Estimation

  • Ardhapurkar, Shubhada;Manthalkar, Ramchandra;Gajre, Suhas
    • Journal of Information Processing Systems
    • /
    • 제8권4호
    • /
    • pp.669-684
    • /
    • 2012
  • Discrete wavelet transforms are extensively preferred in biomedical signal processing for denoising, feature extraction, and compression. This paper presents a new denoising method based on the modeling of discrete wavelet coefficients of ECG in selected sub-bands with Kernel density estimation. The modeling provides a statistical distribution of information and noise. A Gaussian kernel with bounded support is used for modeling sub-band coefficients and thresholds and is estimated by placing a sliding window on a normalized cumulative density function. We evaluated this approach on offline noisy ECG records from the Cardiovascular Research Centre of the University of Glasgow and on records from the MIT-BIH Arrythmia database. Results show that our proposed technique has a more reliable physical basis and provides improvement in the Signal-to-Noise Ratio (SNR) and Percentage RMS Difference (PRD). The morphological information of ECG signals is found to be unaffected after employing denoising. This is quantified by calculating the mean square error between the feature vectors of original and denoised signal. MSE values are less than 0.05 for most of the cases.

Partial Discharge Signal Denoising using Adaptive Translation Invariant Wavelet Transform-Online Measurement

  • Maheswari, R.V.;Subburaj, P.;Vigneshwaran, B.;Iruthayarajan, M. Willjuice
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권2호
    • /
    • pp.695-706
    • /
    • 2014
  • Partial discharge (PD) measurements have emerged as a dominant investigative tool for condition monitoring of insulation in high voltage equipment. But the major problem behind them the PD signal is severely polluted by several noises like White noise, Random noise, Discrete Spectral Interferences (DSI) and the challenge lies with removing these noise from the onsite PD data effectively which leads to preserving the signal for feature extraction. Accordingly the paper is mainly classified into two parts. In first part the PD signal is artificially simulated and mixed with white noise. In second part the PD is measured then it is subjected to the proposed denoising techniques namely Translation Invariant Wavelet Transform (TIWT). The proposed TIWT method remains the edge of the original signal efficiently. Additionally TIWT based denoising is used to suppress Pseudo Gibbs phenomenon. In this paper an attempt has been made to review the methodology of denoising the PD signals and shows that the proposed denoising method results are better when compared to other wavelet-based approaches like Fast Fourier Transform (FFT), Discrete Wavelet Transform (DWT), by evaluating five different parameters like, Signal to noise ratio, Cross-correlation coefficient, Pulse amplitude distortion, Mean square error, Reduction in noise level.

이산계와 탄성 지지보의 동응답 및 진동 인텐시티 저감을 위한 목적함수 해석 (Analyses of the Cost function for the Reductions of the Dynamic Response and the Vibrational Intensity of a Discrete System and Its Elastic Supporting Beam)

  • 김기만;최성대
    • 한국소음진동공학회논문집
    • /
    • 제20권1호
    • /
    • pp.83-91
    • /
    • 2010
  • In this paper, the feasibility of the cost function having two control factors were discussed in compared to two others which has one different control factor respectively. As of the control factors, the dynamic response of a discrete system and the vibrational intensity at the reference point which is the connecting point of a discrete system to a flexible beam were controlled actively by the control force obtained from the minimization of the cost function. The method of feedforward control was employed for the control strategy. The reduction levels of the dynamic response of a discrete system and the vibrational intensity at a reference point, and also the input power induced by the control force were evaluated numerically in cases of the three different cost functions. In comparison with the results obtained from the cost functions of one control factor, which is the dynamic response or the vibrational intensity, in most cases of the cost function of two control factors the better or similar results were obtained. As a conclusion, it is surely noted that both the dynamic response and the vibrational intensity of the vibrating system be controlled up to the expected level by using the single cost function having two control factors.

퍼지클러스터링 기반 의료 영상 워터마킹 (Fuzzy Clustering Based Medical Image Watermarking)

  • ;김종면
    • 정보처리학회논문지:소프트웨어 및 데이터공학
    • /
    • 제2권7호
    • /
    • pp.487-494
    • /
    • 2013
  • 의료 영상 워터마킹은 헬스케어 정보 시스템의 보안 서비스 분야에서 많은 주목을 받고 있다. 본 논문은 워터마킹을 삽입할 최적의 서버 블록 위치 선택을 위한 개선된 퍼지 클러스터링 기법, 이산 웨이블릿 변환 및 이산 코사인 변환을 분할된 회백질 의료 영상에 적용한 블라인드 의료 영상 워터마킹 기법을 제안한다. 모의실험결과, 제안한 워터마킹 기법은 기존의 기법들보다 PSNR과 M-SVD에서 우수한 성능을 보였다. 또한, 제안한 워터마킹 기법은 노이즈 첨가, 필터링, JPEG 압축, 블러링, 히스토그램 균일화, 크로핑과 같은 공격에서도 기존의 기법들보다 정규화된 연관성 값에서 보다 강인함을 보였다.