• Title/Summary/Keyword: Discrete Power System

Search Result 335, Processing Time 0.029 seconds

Arc Detection Performance and Processing Speed Improvement of Discrete Wavelet Transform Algorithm for Photovoltaic Series Arc Fault Detector (태양광 직렬 아크 검출기의 검출 성능 및 DWT 알고리즘 연산 속도 개선)

  • Cho, Chan-Gi;Ahn, Jae-Beom;Lee, Jin-Han;Lee, Ki-Duk;Lee, Jin;Ryoo, Hong-Jae
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.26 no.1
    • /
    • pp.32-37
    • /
    • 2021
  • This study proposes a DC series arc fault detector using a frequency analysis method called the discrete wavelet transform (DWT), in which the processing speed of the DWT algorithm is improved effectively. The processing time can be shortened because of the time characteristic of the DWT result. The performance of the developed DC series arc fault detector for a large photovoltaic system is verified with various DC series arc generation conditions. Successful DC series arc detection and improved calculation time were both demonstrated through the measured actual arc experimental result.

Design of Pulse Tranceiver for Antipodal Ultra Wideband System (Antipodal 초광대역 통신 시스템의 변·복조기 설계)

  • Lee, Jung Suk;Kim, Yoo Chang;Kim, Won Hoo
    • Journal of Advanced Navigation Technology
    • /
    • v.5 no.2
    • /
    • pp.134-140
    • /
    • 2001
  • Ultra Wideband(UWB) system uses wide band signal, which power spectral density likes as a noise floor, so UWB system can be used high speed communication without interfering with other communication system. As this system doesn't use carrier, its structure would be very simple and consume very low power. But conventional UWB system uses Pulse Positioning Modulation(PPM) Method. Therefore it could be to produce discrete power spectrum which decreases system efficiency unintentionally. For eliminating discrete power spectrum and further Euclidean distance, we propose UWB system using Antipodal signal. And we design and simulate antipodal tranceiver using Advanced Design System(ADS).

  • PDF

Development of Test Equipment for KSLV-I Upper Stage (KSLV-I 상단부 시험장비(UTE) 설계 및 개발)

  • Kim, Kwang-Soo;Lee, Soo-Jin;Chung, Eui-Seung;Park, Jeong-Joo
    • Aerospace Engineering and Technology
    • /
    • v.6 no.2
    • /
    • pp.171-179
    • /
    • 2007
  • The Test Equipment for the upper stage of KSLV-I has following functions via umbilical cable interface; external power supply, command output such as discrete and analog, data acquisition, CS-I interface simulation for first stage of KSLV-I and RS-422 serial communication for PDU. The main purpose of UTE is the experiment or function verification of system-level upper stage. To realize this system, we used PXI control system. The UTE is consisted of the PXI control system, power supply, terminal block, internal harness, connector panel and so on. The software functions of UTE are classified by four blocks. These are Discrete/Analog I/O control, PDU RS-422 serial communication control, power supply GPIB control and UTE remote control. In this paper, we will describe the design on the hardware and software of UTE.

  • PDF

New Discrete-Time Modeling and Simulation Techniques for PWM converters (PWM 컨버터에 대한 새로운 이산시간 모델링 및 시뮬레이션 기법)

  • 김만호
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.7 no.3
    • /
    • pp.289-296
    • /
    • 2002
  • New discrete-time modeling and simulation techniques are proposed which take advantages of the special features of PWM converter power stages and their compensation circuits. These techniques provide reduction of system order, and allow for the faster simulation without any numerical convergence problem. A buck converter with two-stage output filter Is employed to confirm the usefulness of the proposed techniques. The simulation results show these techniques can simulate the responoes of PWM converter system up to high frequencies.

A Comparative Study on Fault Detection Algorithm of AC Generator (교류 발전기의 고장 검출 알고리즘에 관한 비교 연구)

  • Park, Chul-Won;Shin, Kwang-Chul;Shin, Myong-Chul
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.2
    • /
    • pp.102-108
    • /
    • 2008
  • AC generator plays an important role of power system. The large AC generator fault may lead to large impacts or perturbations in power system. And then the protection of a generator has very important role in maintaining stability in a power system. In present, the DFT(discrete Fourier transform) based RDR(ratio differential relay) had been widely applied to a internal fault of a generator stator winding. But DFT has a serious drawback. In the course of transforming a target signal to frequency domain, time information is lost. DWT uses a time-scale region. This paper proposes an advanced fault detection algorithm using DWT(discrete Wavelet transform) to enhance the drawback of conventional DFT based relaying. To evaluate the performance of the proposed relaying, we used the test data which were sampled with 720 [Hz] per cycle and obtained from ATP(alternative transient program) simulation. And we made a comparative study of conventional DFT based RDR and the proposed relaying.

A Using Study for Fault Locator Algorithm of Distribution System (배전계통 고장점 표정 알고리즘 적용 연구)

  • Lee, Sung-Woo;Ha, Bok-Nam
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.74_76
    • /
    • 2009
  • This paper presents a discrete wavelet analysis based algorithm to address the fault impedance calculation under transient state in radial power distribution networks. The fault impedances have been derived under different fault conditions. Furthermore, a recursive fault distance estimation method is proposed utilizing the measured fault impedance and power line parameters. The proposed scheme can resolve the errors caused by the non-homogeneous power lines, the presence of lateral loads since, the fault impedance will always be updated with the recursive form. For the verification of the proposed scheme, a filed test has been peformed with varying fault resistances in the 22.9(kV) radial system. Power meters and fault locators were installed at the substation. It was figured out that the performance of the discrete wavelet and the recursive scheme are very good even for high fault resistance condition.

  • PDF

Digital Control of Phase-Shifted Full-Bridge PWM Converter

  • Lim, Jeong-Gyu;Chung, Se-Kyo
    • Journal of Power Electronics
    • /
    • v.8 no.3
    • /
    • pp.201-209
    • /
    • 2008
  • This paper presents the modeling and design of a digital controller for a phase-shifted full-bridge converter (PSFBC) in a discrete-time domain. The discretized PSFBC model is first derived and then analyzed considering the sampling effect and the system parameters. Based on this model, the digital controller is directly designed in a discrete-time domain. The simulation and experimental results are provided to show the validity of the proposed modeling and controller design.

A Study on Automatic Multi-Power Synchronous Transfer Switch using New DFT Comparator (새로운 DFT 비교기를 이용한 자동 다전원 동기절체 스위치에 관한 연구)

  • Kwak, A-Rim;Park, Seong-Mi;Son, Gyung-Jong;Park, Sung-Jun;Kim, Jong-Cheol
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.3
    • /
    • pp.423-431
    • /
    • 2022
  • The UPS(Uninterruptible Power Supply) system operates in the battery charging mode when the grid is normal, and in the UPS mode, which is the battery discharge mode when a grid error occurs. Since the UPS must supply the same voltage as the grid to the load within 4 [ms] in case of a grid error, the switching time and power recovery time should be short when controlling the output voltage and current of the UPS, and the power failure detection time is also important. The power outage detection algorithm using DFT(Discrete Fourier Transform) proposed in this paper compares the grid voltage waveform with the voltage waveform including the 9th harmonic generated through DFT using Schmitt trigger to detect power outage faster than the existing power outage monitoring algorithm. There are advantages. Therefore, it is possible to supply instant and stable power when switching modes in the UPS system. The multi-power-applied UPS system proposed in this paper uses DFT, which is faster than the conventional blackout monitoring algorithm in detecting power failure, to provide stable power to the load in a shorter time than the existing power outage monitoring algorithm when a system error occurs. The detection method was applied. The changeover time of mode switching was set to less than 4 [ms], which is 1/4 of the system cycle, in accordance with KSC 4310 regulation, which was established by the Industrial Standards Council on the regulation of uninterruptible power supply. A 10 [kW] UPS system in which commercial voltage, vehicle generator, and auxiliary diesel generator can be connected to each of the proposed transfer devices was constructed and the feasibility was verified by conducting an experiment.

Design and implementation of low-power VLSI system using software control of supply voltages (소프트웨어 전압 제어를 사용한 저전력 VLSI 시스템의 설계 및 구현)

  • Lee, Seong-Su
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.39 no.4
    • /
    • pp.72-83
    • /
    • 2002
  • In this paper, a novel low-power VLSI system architecture was proposed. By exploiting software control of supply voltages, it simplifies hardware implementation, reduces power consumption efficiently, and avoids complicated interface circuits. The proposed architecture models clock frequency-supply voltage relationship by software modelling, enables individual control of supply voltages for all chips in the system, and restricts clock frequency to discrete levels of $f_{CLK}$, $f_{CLK}$2, $f_{CLK}$3... where $f_{CLK}$ is the master clock frequency A prototype system was implemented by modifying off-the-shelf microprocessor evaluation board and adding simple discrete devices such as level shifters and voltage switches. It was measured that the power consumption was reduced from 0.58W to 0.12W in the Prototype system. system.

Study on a Probabilistic Load Forecasting Formula and Its Algorithm (전력부하의 확률가정적 최적예상식의 유도 및 전산프로그래밍에 관한 연구)

  • Myoung Sam Ko
    • 전기의세계
    • /
    • v.22 no.2
    • /
    • pp.28-32
    • /
    • 1973
  • System modeling is applied in developing a probabilistic linear estimator for the load of an electric power system for the purpose of short term load forecasting. The model assumer that the load in given by the suns of a periodic discrete time serier with a period of 24 hour and a residual term such that the output of a discrete time dynamical linear system driven by a white random process and a deterministic input. And also we have established the main forecasting algorithms, which are essemtally the Kalman filter-predictor equations.

  • PDF