• 제목/요약/키워드: Discontinuous conduction mode boost converter

검색결과 58건 처리시간 0.025초

Improved Power Quality IHQRR-BIFRED Converter Fed BLDC Motor Drive

  • Singh, Bhim;Bist, Vashist
    • Journal of Power Electronics
    • /
    • 제13권2호
    • /
    • pp.256-263
    • /
    • 2013
  • This paper presents an IHQRR (Integrated High Quality Rectifier Regulator) BIFRED (Boost Integrated Flyback Rectifier Energy Storage DC-DC) converter fed BLDC (Brushless DC) motor drive. A reduced sensor topology is derived by utilizing a BIFRED converter to operate in a dual DCM (Discontinuous Conduction Mode) thus utilizing a voltage follower approach for the PFC (Power Factor Correction) and voltage control. A new approach for speed control is proposed using a single voltage sensor. The speed of the BLDC motor drive is controlled by varying the DC link voltage of the front end converter. Moreover, fundamental frequency switching of the VSI's (Voltage Source Inverter) switches is used for the electronic commutation of the BLDC motor which reduces the switching losses in the VSI. The proposed drive is designed for a wide range of speed control with an improved power quality at the AC mains which falls within the recommended limits imposed by international power quality standards such as IEC 61000-3-2.

영전압, 영전류 스위칭 1단 방식 역률 보상 AC/DC 컨버터 (ZVZCS Single-Stage Power Factor Corrected Converter)

  • 강필순;박성준;권순재;김철우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.1348-1350
    • /
    • 2000
  • Zero-voltage and zero-current switched single-stage approach with high power factor is presented to reduce the switching losses and to achieve sinusoidal, unity power factor input currents. This single-stage approach, which combines a boost converter used as PFC with a half-bridge converter used as do to do conversion into one power stage, has a simple structure and low cost. At the same time, since the switches of the proposed converter are designed to be turned on at zero-voltage and off at zero-current, the switching losses could be reduced considerably. Detailed analysis and experimental results are presented on the proposed converter, which is operated at constant switching frequency and in discontinuous conduction mode.

  • PDF

Random PWM 기법을 이용한 3상 승압형 컨버터 전도노이즈 저감에 관한 연구 (A study on the Conducted Noise Reduction in Three-Phase Boost Converter using Random Pulse Width Modulation)

  • 정동효
    • 전기학회논문지P
    • /
    • 제51권3호
    • /
    • pp.120-125
    • /
    • 2002
  • The switching-mode power converter has been widely used because of its features of high efficiency and small weight and size. These features are brought by the ON-OFF operation of semiconductor switching devices. However, this switching operation causes the surge and EMI(Electromagnetic Interference) which deteriorate the reliability of the converter themselves and entire electronic systems. This problem on the surge and noise is one of the most serious difficulties in AC-to-DC converter. In the switching-mode power converter, the output voltage is generally controlled by varying the duty ratio of main switch. When a converter operates in steady state, duty ratio of the converter is kept constant. So the power of switching noise is concentrated in specific frequencies. Generally, to reduce the EMI and improve the immunity of converter system, the switching frequency of converter needs to be properly modulated during a rectified line period instead of being kept constant. Random Pulse Width Modulation (RPWM) is performed by adding a random perturbation to switching instant while output-voltage regulation of converter is performed. RPWM method for reducing conducted EMI in single switch three phase discontinuous conduction mode boost converter is presented. The more white noise is injected, the more conducted EMI is reduced. But output-voltage is not sufficiently regulated. This is the reason why carrier frequency selection topology is proposed. In the case of carrier frequency selection, output-voltage of steady state and transient state is fully regulated. A RPWM control method was proposed in order to smooth the switching noise spectrum and reduce it's level. Experimental results are verified by converter operating at 300V/1kW with 5%~30% white noise input. Spectrum analysis is performed on the Phase current and the CM noise voltage. The former is measured with Current Probe and the latter is achieved with LISN, which are connected to the spectrum analyzer respectively.

단일 전력단 단상 공진형 영전류 스위칭 역률 개선 회로 (Single-Stage Single-Phase Integrated ZCS Quasi-Resonant Power Factor Preregulator Based on Forward Topology)

  • 구관본;이준영;윤명중
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.639-642
    • /
    • 1999
  • An integrated zero current switching(ZCS) quasi-resonant converter(QRC) for power factor correction and high efficiency with single switch is proposed in this thesis. Boost integrated circuit operating discontinuous conduction mode(DCM) and QRC are used for power factor correction and reducing switching loss, respectively. A prototype converter has been designed and experimented. At rated condition, the THD in the input current waveform of this prototype has approximately 18%. The efficiency is obtained about 70%, the power factor is about 0.985 as well. Therefore, the proposed converter is suitable for a low power level converter with operating switching frequency above several hundred KHz.

  • PDF

입력전류 파형 개선효과를 갖는 전자식 안정기에 관한 연구 (A Study on Electronic Ballast with Improved Input Current Waveform)

  • 허태원;손영대;우정인
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.1239-1241
    • /
    • 2004
  • In this paper, electronic ballast with Interleaved Boost Cell is presented. The proposed topology is based on a single-stage ballast which combines a boost converter and a half-bridge series resonant inverter High power factor and low THD(reduction of current ripple) are achieved by using the boost semi-stage operating in discontinuous conduction mode, and inverter semi-stage operated above resonant frequency to provide zero voltage switching is employed to ballast the fluorescent lamp. The experimental results from the ballast system with fluorescent lamps have demonstrated the feasibility of the proposed electronic ballast.

  • PDF

Lyapunov Based Adaptive-Robust Control of the Non-Minimum phase DC-DC Converters Using Input-Output Linearization

  • Salimi, Mahdi;Zakipour, Adel
    • Journal of Power Electronics
    • /
    • 제15권6호
    • /
    • pp.1577-1583
    • /
    • 2015
  • In this research, a combined adaptive-robust current controller is developed for non-minimum-phase DC-DC converters in a wide range of operations. In the proposed nonlinear controller, load resistance, input voltage and zero interval of the inductor current are estimated using developed adaptation rules and knowing the operating mode of the converter for the closed-loop control is not required; hence, a single controller can be employed for a wide load and line changes in discontinuous and continuous conduction operations. Using the TMS320F2810 digital signal processor, the experimental response of the proposed controller is presented in different operating points of the buck/boost converter. During transition between different modes of the converter, the developed controller has a better dynamic response compared with previously reported adaptive nonlinear approach. Moreover, output voltage steady-state error is zero in different conditions.

$PRS^2$를 사용한 3상 AC/DC 컨버터의 부하특성 (Load Characteristic of Three-phase AC/DC Boost Converter Using a $PRS^2$.)

  • 강욱중;이현우;서기영;백수현;한경희;전중함
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 추계학술대회 논문집 학회본부
    • /
    • pp.438-440
    • /
    • 1997
  • This paper proposed a partial resonant switching three-phase high power factor converter using a $PRS^2$(Partial Resonant Soft Switch). The proposed converter has a merit of simple controlled circuit because the input current control DCM(Discontinuous Conduction Mode). And it is improve to input power factor that the snubber capacitor's energy regenerate to the AC source side. This topology is reduced a current/voltage stresses of resonant devices in addition to a partial resonant strategy. The result of simulations with the proposed topology included in this paper.

  • PDF

Random PWM 기법을 이용한 전도노이즈 저감 (A study on the Conducted Noise Reduction in Random PWM)

  • 정동효
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.154-158
    • /
    • 2006
  • The switching-mode power converter has been widely used because of its features of high efficiency and small weight and size. These features are brought by the ON-OFF operation of semiconductor switching devices. However, this switching operation causes the surge and EMI(Electromagnetic Interference) which deteriorate the reliability of the converter themselves and entire electronic systems. This problem on the surge and noise is one of the most serious difficulties in AC-to-DC converter. Random Pulse Width Modulation (RPWM) is peformed by adding a random perturbation to switching instant while output-voltage regulation of converter is performed. RPWM method for reducing conducted EMI in single switch three phase discontinuous conduction mode boost converter is presented. The more white noise is injected, the more conducted EMI is reduced. But output-voltage is not sufficiently regulated. This is the reason why carrier frequency selection topology is proposed. In the case of carrier frequency selection, output-voltage of steady state and transient state is fully regulated. A RPWM control method was proposed in order to smooth the switching noise spectrum and reduce it's level. Experimental results are verified by converter operating at 300v/1kW with $5%{\sim}30%$ white noise input. Spectrum analysis is performed on the Phase current and the CM noise voltage. The former is measured with Current Probe and the latter is achieved with LISN, which are connected to the spectrum analyzer respectively.

  • PDF

고역률 초퍼-인버터 일체형 고주파 발생회로의 특성해석에 관한 연구 (A Study on Characteristic Analysis of High Frequency Generating Circuit Integrated Chopper-Inverter with High Power-Factor)

  • 원재선;박재욱;남승식;이봉섭;석줄기;김동희
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제53권10호
    • /
    • pp.610-617
    • /
    • 2004
  • This paper presents a novel high frequency generating circuit integrated chopper-inverter using ZVS with high power-factor. The proposed topology is integrated half-bridge boost rectifier as power factor corrector(PFC) and half-bridge high frequency resonant inverter into a single-stage. The input stage of the half-bridge boost rectifier works in discontinuous conduction mode(DCM) with constant duty cycle and variable switching frequency. So that a boost converter makes the line current follow naturally the sinusoidal line voltage waveform. Simulation results have demonstrated the feasibility of the proposed high frequency resonant inverter. Characteristics values based on characteristics analysis through circuit analysis is given as basis data in design procedure. Also, experimental results are presented to verify theoretical discussion. This proposed inverter will be able to be practically used as a power supply in various fields as induction heating applications. fluorescent lamp and DC-DC converter etc.

전류원 인버터의 병렬운전에 의한 축전지 없는 태양광 시스템의 구성 (Stand-Alone PV System by Parallel Operation Control of Current-Source Inverter without Battery)

  • 박성준;김종달
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제52권6호
    • /
    • pp.291-297
    • /
    • 2003
  • This paper presents a current-source-inverter based on a buck-boost configuration and its application for residential photovoltaic system. The proposed circuit has five switches. Among them, only one switch acts as chopping, and the other determine the polarity of output; therefore, it can reduce the switching loss. Because the input inductor current is operated on the discontinuous conduction mode, high power factor can be achieved without additional input current controller. So the overall system shows a simple structure. The operational modes are analysed in depth, and then it was verified through the experimental results using a 150 [W] prototype equipped with digital signal processor TMS320F241.