• 제목/요약/키워드: Discharges

검색결과 1,134건 처리시간 0.022초

정상흐름하 천해역 수로에서의 저밀도수 표층방출 모델링 (Modeling buoyant surface discharges in a shallow channel with steady flow)

  • Jung, Kyung-Tae;Jin, Jae-Youll;Park, Jin-Soon;Yum, Ki-Dai;Park, Chang-Wook;Kim, Sung-Dae;Suk Yoon
    • 한국해안해양공학회:학술대회논문집
    • /
    • 한국해안해양공학회 2002년도 한국해안해양공학발표논문집 Proceedings of Coastal and Ocean Engineering in Korea
    • /
    • pp.191-197
    • /
    • 2002
  • The prediction of the dynamic behaviors of buoyant water discharges into a large volume of water bodies, the flows of water accompanying the density differences due to temperature differences and sometimes also to salinity differences, have attracted great concern over several decades. Heated water surface discharges from power plants and freshwater discharges in estuaries are typical examples of the buoyant flows. (omitted)

  • PDF

공기중 코로나방전의 초음파신호 특성 (Ultrasonic Signal Characteristics of Corona Discharges in Air)

  • 이상우;김인식;이광식;이동인;이동헌;배상준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 E
    • /
    • pp.1702-1704
    • /
    • 1998
  • In order to establish the usefulness of ultrasonic techniques for detecting corona discharges in high-voltage power apparatus, it is first necessary to determine the relationship between electrical and ultrasonic signals of corona discharges in air. In this paper, various characteristics of ultrasonic signal detection for point-to-plane corona discharges using a 200[kHz] ultrasonic sensor are examined. In regard to the attenuation and directivity of ultrasonic signals, the signals were inversely proportional to the distance between corona sources and ultrasonic receiving sensors, and half attenuation angles were approximately 7.0 degree. Ultrasonic signals of positive polarities were first obserbed at corona inception voltages. and the signals were increased with increasing the applied voltages.

  • PDF

유량측정 방법의 정확도 분석 -괴산댐 하류 달천 적용 사례를 중심으로- (Inter-comparison of Accuracy of Discharge Measurement Methods - A Case Study Performed in the Dalcheon River Downstream of the Goesan Dam-)

  • 이찬주;김동구;권성일;김원
    • 한국수자원학회논문집
    • /
    • 제43권12호
    • /
    • pp.1039-1050
    • /
    • 2010
  • 본 연구에서는 괴산댐 하류 달천에서 6가지 직접 유량 측정 방법-유속면적법, 봉부자법, ADCP이동측정법, ADCP정지 측정법, 전자파표면유속계, LSPIV-을 적용하고, 이를 댐 방류량 및 유속면적법과 비교함으로써 정확도를 상호 평가하였다. 이를 위해 2005년부터 2010년까지 실시된 총 39회의 유량측정결과가 분석되었다. 댐 방류량과의 비교 결과, 봉부자법을 제외한 나머지5가지 방법은 평균 6.2% 이내의 절대값오차를 나타냈다. 유속면적법과 다른 4가지방법을 비교할 경우, 전자파표면유속계는 7.35%, 나머지 3가지 방법은 6% 이내의 절대값오차를 나타냈다. 봉부자법은 댐 방류량 및 유속면적법과 비교하여도 오차의 범위가 크게 나타났는데, 이에 대해서는 추가적인 검증이 필요하다.

뇌방전에 의해 방사되는 전계와 자계파형의 특성 (Characteristics of the Electric and Magnetic Field Waveforms Radiated by Lightning Discharges)

  • 이복희;이경옥
    • 한국전자파학회논문지
    • /
    • 제7권4호
    • /
    • pp.300-309
    • /
    • 1996
  • 뇌방전에 의해 방사되는 전계와 자계의 세기는 시변성으로 세기도 대단히 크게 변화하며, 최신의 전자기기에 관련한 전자계 양립성에 대한 과제 중의 하나가 직격뢰뿐만 아니라 근접뢰에 의해 발생하는 과도전압에 대한 효율적이고 경제적인 보호에 관한 것이다. 본 논문에서는 뇌전자계 임펼스파형에 관한 상세한 정보를 얻기 위해서 1995년의 여름에 발생한 뇌방전에 의해 방사된 전계와 자계를 고속전계센서와 루프형 자계센서로 측정한 파형과 이들의 특성을 분석한 결과를 기술 하였다. 전계와 자계의 신호는 12비트의 분해능과 5000포인트의 기억용량을 가지는 기록장치를 이용하여 200 ns 의 시간간격으로 생플링되어 연속적으로 기록하였다. 귀환뇌격시에 방사된 전계와 자계의 파형은 운내방전의 전계와 자계파형과는 매우 달랐다. SOkm이상의 거리 에서 발생한 운내뇌방전에 의해 방사된 자계파형은 전계파형과 거의 일치하였다. 또한 뇌방전에 의해 방사되는 전계와 자계의 주요 주파수 성분은 수 kHz에서 수백 kHz의 범위를 갖는 것으로 나타났다.

  • PDF

화원 수위관측소 지점의 고리모양 수위-유량 관계곡선 작성 (Development of Looped Rating Curve at Hwawon Station)

  • 강신욱;이상호;황만하
    • 한국수자원학회논문집
    • /
    • 제39권6호
    • /
    • pp.487-494
    • /
    • 2006
  • 화원 지점의 홍수시 유량은 수위가 상승할 때와 하강할 때 동일한 수위에 대해 많은 차이를 나타내고, 이와 같이 이력효과의 크기가 클 경우에는 많은 오차가 발생할 수 있다. 유량 환산 오차를 줄이기 위해 낙동강 본류 화원 수위관측소 지점에 대한 고리모양 수위-유량 관계곡선을 작성하였다. 하천유량과 단순 환산된 유량의 편차를 계산하기 위해 부정류 모의 사례로부터 (수위, 유량) 자료쌍을 획득하여 단순 수위-유량 관계곡선식을 작성하였다. 이 관계에서 이탈하는 유량편차 ${\Delta}Q$와 수위변화 따른 하천폭과 시간변화율의 곱인 $B{\Delta}h/{\Delta}t$와의 관계로부터 고리모양 수위-유량 관계의 유량을 구하였다. ${\Delta}Q$$B{\Delta}h/{\Delta}t$는 높은 상관관계를 나타내었다. 이로부터 계산된 유량은 1997년의 수위 7m이상 관측유량 11개 중 7개가 고리모양 수위-유량 환산관계의 유량과 10% 이내의 차이를 보였고, 수위 9m이상의 1998년 관측유량은 고리모양에 근접하였다. 화원 지점과 같이 고리폭이 큰 지점은 단순 수위-유량 관계보다 고리모양 수위-유량 관계를 적용하는 것이 유량 환산의 오차를 줄 일 수 있을 것으로 기대된다.

DBD(Dielectric Barrier Discharges)에서 전공 플라즈마 발생에 대한 해석적 연구 (An Analysis of Vacuum Plasma Phenomena in DBD(Dielectric Barrier Discharges))

  • 선명수;차성훈;김종봉;김종호;김성영;이혜진
    • 한국정밀공학회지
    • /
    • 제26권3호
    • /
    • pp.122-128
    • /
    • 2009
  • DBD(Dielectric Barrier Discharges) plasma is often used to clean the surface of semiconductor. The cleaning performance is affected mainly by plasma density and duration time. In this study, the plasma density is predicted by coupled simulation of flow, chemistry mixing and reaction, plasma, and electric field. 13.56 MHz of RF source is used to generate plasma. The effect of dielectric thickness, gap distance, and flow velocity on plasma density is investigated. It is shown that the plasma density increases as the dielectric thickness decreases and the gap distance increases.

운방전에 의해 발생한 전자장 펄스의 통계적 특성 (Statistical Characteristics of the Electromagnetic Pulses Radiated from Intracloud Discharges)

  • 이복희;정동철;이동문;안창환
    • 조명전기설비학회논문지
    • /
    • 제18권5호
    • /
    • pp.112-117
    • /
    • 2004
  • 본 연구에서는 뇌전자장 펄스에 관한 상세한 정보를 얻기 위한 목적으로 운방전에 의해서 방사되는 전자파 펄스를 측정하고, 이의 특성과 파라미터를 통계적으로 분석하였다. 운방전에 의해서 방사된 전자파 펄스는 낙뢰에 의한 것과는 확연하게 달랐으며, 후속 스토로크로 갈수록 주 방전에 의한 양방성 전자파 펄스의 영점교차시간과 펄스폭은 짧게 나타났다. 또한 주 방전에 의한 양방성 전자파 펄스의 파두부분에는 좁고 빠른 리더펄스가 중첩되어 나타났으며, 이 중첩된 리더펄스의 평균 개수는 정극성에서 61$\pm$0.74, 부극성에서 1.75$\pm$0.73이었다.

유역특성인자를 이용한 설계홍수량 추정에 관한 연구 (Study of Design Flood Estimation by Watershed Characteristics)

  • 박기범
    • 한국환경과학회지
    • /
    • 제15권9호
    • /
    • pp.887-895
    • /
    • 2006
  • Through this research of the analysis on the frequency flood discharges regarding basin property factors, a linear regression system was introduced, and as a result, the item with the highest correlation with the frequency flood discharges from Nakdong river basin is the basin area, and the second highest is the average width of basin and the river length. The following results were obtained after looking at the multi correlation between the flood discharge and the collected basin property factors using the data from the established river maintenance master plan of the one hundred twenty-five rivers in the Nakdong river basin. The result of analysis on multivariate correlation between the flood discharges and the most basic data in determining the flood discharges as basin area, river length, basin slope, river slope, average width of basin, shape factor and probability precipitation showed more than 0.9 of correlation in terms of the multi correlation coefficient and more than 0.85 for the determination coefficient. The model which induced a regression system through multi correlation analysis using basin property factors is concluded to be a good reference in estimating the design flood discharge of unmeasured basin.

수위관측과 수리학적 하도추적에 의한 하천유량 간접추정 (Stream Discharge Estimation by Hydraulic Channel Routing and Stage Measurement)

  • 이상호;강신욱
    • 한국수자원학회논문집
    • /
    • 제34권5호
    • /
    • pp.543-549
    • /
    • 2001
  • 수리학적 하도추적으로부터 하천유량을 간접추정하였다. 짧은 하천구간의 세 지점 연속수위자료와 하천 단면 자료만을 사용하여 조도계수 추정b과 하천유량 계산이 가능하였다. 유량의 간접추정 과정에서, 상류-하류 경계조건을 수위-수위 조건으로 사용하였다. 미국 미시시피 강의 상류 구간 자료가 사용되었고 수리학적 하도추적에는 DWO-PER (operational dynamic wave model)를 이용하였다. DWOPER 모형에서 수정 Newton-Raphson법에 의한 조도계수 추정과정을 개선하기 위하여 SCE-UA 전역최적화 기법을 적용하였으며, SCE-UA 기법의 결과가 적은 오차를 보였다. 특정 홍수에 대하여 유량을 추정한 결과, 몇 개를 제외한 대부분의 계산유량이 10% 이내의 오차를 보였다.

  • PDF

Characteristics of Sustain Discharges in AC PDP with various Coplanar-Gaps and Auxiliary Electrode

  • Lee, Kyo-Sung;Shin, Nam-Hoon;Shin, Bhum-Jae;Choi, Kyung-Cheol;Jang, Sang-Hun;Park, Hyoung-Bin;Lee, Seong-Eui
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2005년도 International Meeting on Information Displayvol.I
    • /
    • pp.175-178
    • /
    • 2005
  • The spatio-temporal behaviors of Infra Red(IR) emission images of the sustain discharges were observed in AC PDP with various coplanar-gaps and auxiliary electrode. When the height of barrier rib was fixed, IR intensity of the sustain discharges in AC PDP did not increase with increase of coplanar-gap. The IR efficiency of sustain discharges showed the similar behavior with the IR intensity. The IR intensity had its maixmum value when the coplanar-gap was $200\;{\mu}m$ and the height of barrier rib was $150\;{\mu}m$. It was also found that the auxiliary electrode in the front plate enhanced IR emission during sustain discharge when the pulse was applied to the auxiliary electrode.

  • PDF