• 제목/요약/키워드: Discharged water

검색결과 763건 처리시간 0.02초

팔당호 상류수계에 위치한 공공 하수종말처리시설의 총인 배출 최적관리 (Optimal Management Scheme for Phosphorus Discharged from Public Sewage Treatment Plant Located in Upstream Basin of Paldang Lake)

  • 우영국;박은영;전양근;정명숙;임재명
    • 한국물환경학회지
    • /
    • 제27권2호
    • /
    • pp.200-209
    • /
    • 2011
  • The purpose of the study is to optimally manage sewage treatment plant with analysis of phosphorus contribution and improvement of water quality contributing rate in the effect of inflowing point of effluent and Pal-Dang lake after reducing T-P discharge from large scale public sewage treatment plant at upstream of Pal-Dang lake. Also, this study, for enforcement of T-P in effluent, plans optimal management of effluent T-P through examining propriety of environmental, technological, and economical aspect such as water quality standard of domestic and foreign T-P and related policy. In regarding optimal management of T-P discharged from public sewage treatment plant located in upstream of Pal-Dang lake, the study drew following conclusions. With the optimal management of public sewage treatment plant, it showed that a pollution level became higher in the order of Sumgang E in South-Han river, C in Dalcheon, B1 B2, A in North-Han river, and J in Kyungancheon, and it is required reduction of T-P first. The highest value in analysis of benefit-costs from sewage treatment plant in the selected research area was Kyungan B, and the others are with the order of Jojong A, Bokha A, Kyungan A, and Yanghwa A. With result of this study, all 14 areas are required more enforced phosphorus treatment. The study resulted that the most top priority areas were Hangang F, Sumgang B, and Gyungan A, top priority areas were Bokha A, Dalcheon B, and Cheongmi A, priority areas were Hangang E, Heukcheon A, Gyungan B, and Jojong A, and potential areas were Sumgang A, Yanghwa A, Dalcheon A, and Hangang D. It seems to be appropriate to apply 0.2 mg/L of T-P treatment for water supply source reservation, 0.5 mg/L for the other areas by locally, and 0.2~0.5 mg/L for biological nitrogen phosphorus treatment method and 0.5~1 mg/L for Conventional Activated Sludge by technologically. Also, it may be appropriate to apply 0.2 mg/L for the most top priority area(I), 0.3 mg/L for the top priority area(II), 0.4 mg/L for priority area(III), and 0.5 mg/L for potential area(IV) by the separation of priority area.

하수처리장 분산방류에 의한 방류수역의 수질개선효과 (Improvement Effect of Water Quality along the Water Discharged Area by Water Dispersion from the Sewage Disposal Plant)

  • 김동수;박종태;김용구;박성천
    • 한국환경과학회지
    • /
    • 제17권1호
    • /
    • pp.113-118
    • /
    • 2008
  • [ $6{\sim}13mg/L$ ] base water concentration on monthly BOD has been kept at the Geukrak bridge point for this research target and it indicates the water quality under the existed rank. Due to this present condition of water quality, the demage of ecology from the upper stream to the lower one of the bridge could be conjectured. Moreover, nonstructural extinction of the ecology seems to have gotten worse between both the streams of Yeoungsan River. On this research, eco-corridor between the upper stream and the lower stream of the river should be ensured, the ecological demage needs to be cut off, a dispersed discharge method which the existed method of the 1st sewage plant in Gwangju was enhanced to should be inducted for the procuring of various water ecosystem, and the conditions by the scenario suggested from this research could be applied to a water quality model. then, analysis the improvement effect of the water quality adjacent the river. From the test result, Case3-Type1 scenario is thought to be the best one. From the test result with Case3-Type1 when the concentrated discharge was never done, 0.07 mg/L of BOD concentration was increased at the lower stream where Yeoungbon B point (Haksan Bridge) is but the water improvement effect of $0.24{\sim}2.87mg/L$ is thought to have been done at the area of water deterioration.

유역형상과 오염부하배출 특성을 고려한 유달계수 산정 (Estimating the Pollution Delivery Coefficient with Consideration of Characteristics Watershed Form and Pollution Load Washoff)

  • 하성룡;박정하;배명순
    • 환경영향평가
    • /
    • 제16권1호
    • /
    • pp.79-87
    • /
    • 2007
  • The performance of a stream water quality analysis model depends upon many factors attributed to the geological characteristics of a watershed as well as the distribution behaviors of pollutant itself on a surface of watershed. Because the model run has to import the pollution load from the watershed as a boundary condition along an interface between a stream water body and a watershed, it has been used to introduce a pollution delivery coefficient to behalf of the boundary condition of load importation. Although a nonlinear regression model (NRM) was developed to cope with the limitation of a conventional empirical way, this an up-to-date study has also a limitation that it can't be applied where the pollution load washed off (assumed at a source) is less than that delivered (observed) in a stream. The objective of this study is to identify what causes the limitation of NRM and to suggest how we can purify the process to evaluate a pollution delivery coefficient using many field observed cases. As a major result, it was found what causes the pollution load delivered to becomes bigger than that assumed at the source. In addition, the pollution load discharged to a stream water body from a specific watershed was calculated more accurately.

한강의 부영양화에 대한 조사연구 (The Investigation of the Han River Eutrophication)

  • 신정식;정종흡;나규환
    • 환경위생공학
    • /
    • 제14권4호
    • /
    • pp.77-84
    • /
    • 1999
  • Most river quality problems are generated by pollutants which are discharged into the river as a consequence of human activities. And eutrophication occurs when water is over enriched with nutrients, principally nitrate and phosphate. Both these nutrients are found in many waste products, especially sewage even when the waste is treated. Eutrophication is concerned in lakes, but it also causes problems in river. Wide growth of Phytoplankton in rivers, leads to blockage of channels, but the main concern is deoxygenation because of the increase in plant life's demand for oxygen in revers. Fish, plant and animals die due to lack of oxygen. The increase of algae floating on the tops of water looks ugly and has attracted public attention and concern in recent years. One way of controlling eutrophication is to restrict the amount of waste carrying nitrate or phosphate from entering the water in the first place. another way is to remove it from the water after it has been entered. This study was carried out to investigate on the trophic state, nutrients and Chlorophyll-a concentration in the Han River. The results were as follows:1. Concentrations of total nitrogen were 2.208~9.221(5.133)mg/$\ell$2. Concentrations of total phosphate were 0.045~0.614(0.195)mg/$\ell$3. Chlorophyll-a concentration were $0.0-25.3(9.6)mg/m^3$.4. The correlation coefficient between T-P and Chlorophyll-a concentration was r=-0.856 at Sungsan sampling site.5. The correlation coefficient was r=-0.578~-0.767, between Paldang Dam outflow and Chlorophyll-a concentration at all sampling sites.

  • PDF

섬유여과기와 전기분해조를 병합한 물 재이용 시스템 설계 (Design of a Water Reuse System Combined with a Fiber Filtration and Electrolysis)

  • 신춘환
    • 한국환경과학회지
    • /
    • 제24권11호
    • /
    • pp.1385-1391
    • /
    • 2015
  • A water reuse system was designed for a demonstration plant by combining fiber filtration and electrolysis. A discharged dye wastewater after treated with biomedia was used in this study. It was found that an additional removal of suspended solids (SS) was feasible with 2-stage filtration while electrolysis was not effective. Also, $COD_{cr}$ and $COD_{Mn}$ were not removed with 2 -stage filtration but electrolysis resulted in about 26.9% additional removal. This indicates that electrolysis play an important role in organic removal. Removal of T-N and T-P was negligible with 1 and 2-stage fiber filtration and low-level electrolyte. However, with 2000 ppm of electrolyte, their removal efficiencies were about 83.1 and 60%, respectively, suggesting that the removal rates are well associated with the electrolyte concentrations. With high-level electrolyte, colority was removed about 82% while chlorine ions were removed only about 10%. Therefore, to treat underground water containing high-level salinity in the follow-up study, based on the results in this paper, a combined system with selection of additional unit process and reverse osmosis will be designed.

열회수에 따른 고온 태양열 열화학 싸이클의 수소 생산에 관한 연구 (A Study on Hydrogen Production with High Temperature Solar Heat Thermochemical Cycle by Heat Recovery)

  • 조지현;서태범
    • 한국태양에너지학회 논문집
    • /
    • 제37권2호
    • /
    • pp.13-22
    • /
    • 2017
  • Two-step water splitting thermochemical cycle with $CeO_2/ZrO_2$ foam device was investigated by using a solar simulator composed of 2.5 kW Xe-Arc lamp and mirror reflector. The hydrogen production of $CeO_2/ZrO_2$ foam device depending on heat recovery of Thermal-Reduction step and Water-Decomposition step was analyzed, and the hydrogen production of $CeO_2/ZrO_2$ and $NiFe_2O_4/ZrO_2$ foam devices was compared. Resultantly, the quantity of hydrogen generation increased by 52.02% when the carrier gas of Thermal-Reduction step is preheated to $200^{\circ}C$ and, when the $N_2/steam$ is preheated to $200^{\circ}C$ in the Water-Decomposition step, the quantity of hydrogen generation increased by 35.85%. Therefore, it is important to retrieve the heat from the highly heated gases discharged from each of the reaction spaces in order to increase the reaction temperature of each of the stages and thereby increasing the quantity of hydrogen generated through this.

호소의 난분해 물질 축적 영향요인의 평가 (Evaluation of Affecting Factors for Refractory Organics Accumulated in the Lakes)

  • 김성원;김건하;최의소
    • 한국물환경학회지
    • /
    • 제22권4호
    • /
    • pp.720-726
    • /
    • 2006
  • Long-term monitoring results of water qualities at major lakes in Korea showed COD (chemical oxygen demand) concentrations have been increasing while BOD (biochemical oxygen demand) concentrations have been decreasing during last decades. This was mainly due to refractory organic matters have been accumulated in the water body. In this study, the possible causes of COD concentration increase were evaluated. From the statistics, it can be understood that potent pollutant sources including fertilizer consumption, population, livestock, and carbon uptake have increased. Leaching tests were carried out with soils and biomasses sampled at agricultural-forestry area. From the leaching experiments, leachate qualities as a ratio of $COD_{Cr}/BOD$ were in the range of 2.5-5.0, implying that NOM (natural organic matters) discharged from the forestry area was mainly responsible for the COD accumulation. It can be understood from this research that diffuse pollutants from forestry areas should be controlled properly to reduce COD accumulation in the lakes.

전기화학적 처리에 의한 배추 절임염수 재이용 가능성 평가 (Evaluation of brine reuse on salting of chinese cabbage using electrochemical process)

  • 정희숙;이은실;한성국;한응수
    • 상하수도학회지
    • /
    • 제28권5호
    • /
    • pp.541-548
    • /
    • 2014
  • The pickling brine generated from the salting process of kimchi production is difficult to treat biologically due to very high content of salt. When pickling brine is treated and discharged, it cannot satisfy the criteria for effluent water quality in clean areas, while resources such as the salt to be recycled and the industrial water are wasted. However, sterilization by ozone, UV and photocatalyst is expensive installation costs and operating costs when considering the small kimchi manufacturers. Therefore there is a need to develop economical process. The study was conducted on the sterilization efficiency of the pickling brine using electrochemical processing. The electrochemical treatment of organic matters has advantages over conventional methods such as active carbon absorption process, chemical oxidation, and biological treatment because the response speed is faster and it does not require expensive, harmful oxidizing agents. This study were performed to examine the possibility of electrochemical treatment for the efficient processing of pickling brine and evaluated the performance of residual chlorine for the microbial sterilization.

표층밀도분류의 3차원 수치해석 (Three-Dimensional Numerical Analysis of Surface Buoyant Jets)

  • 허재영
    • 한국해안해양공학회지
    • /
    • 제3권3호
    • /
    • pp.152-162
    • /
    • 1991
  • 하구유출유의 유동특성을 조사하기 위한 목적으로 3차원 표층밀도 분류에 관한 자유수표면을 갖는 수치 모델을 개발하였다. 난류전단응력 및 난류부력 유속은 과동점성 및 과동확산의 항으로 표현되었다. 방류수와 주위수와의 밀도차에 기인하는 성층안정효과는 경험공식에 의해 고려되었다. 기발표되어 있는 많은 실험결과와 본 모델에 의한 계산결과와의 비교로부터 본 모델의 타당성을 확인하고 최적한 성층화 함수를 확정하였다. 표층밀도분류의 3차원적인 거동특성을 조사하고, 밀도 Froude수, 방류구의 형상비 및 수표면의 변동이 유동에 미치는 영향에 대하여 토의하였다.

  • PDF

도시 하수의 해양방류 및 근역혼합특성 분석 (Analysis of Ocean Discharges of Municipal Water and its Near-Field Mixing Characteristics)

  • 김강민;김지연;이중우
    • 한국항만학회지
    • /
    • 제14권2호
    • /
    • pp.241-249
    • /
    • 2000
  • The amount of municipal water has been increased rapidly up to now and it is necessary to treat and dispose the wastewater effectively. The recent trend of the effluent disposal system, after treatment, show a nearshore discharge which has an outfall with length somewhere between the shoreline discharge and an extended deepwater outfall. There is no universal solution to municipal water treatment and disposal and each case must be examined on its merits and on economic, technical and environmental bases. In this study we focused mostly on the scientific and engineering aspects of ocean disposal through the outfall. For this purpose, we made an investigation to the near-field characteristics of discharged water and made some comparison with the existing experimental results. We also applied it to the Pusan Jungang Effluent Outfall System, which is planned to build in the Gamchun harbour and will be completed in 2011. The model output showed the trajectoral variation of dilution and mixing behavior for three cases of outfall system. Dilution differences have been simulated and found the highest dilution condition under the different displacement of outfall system. On the basis of these outputs it will be proposed the optimum outfall system type and location.

  • PDF